These instructions should be read carefully and left with the user of the product for future reference.



Similar documents
Fixture One Power Cord One User Manual One Omega Bracket One DMX Cable - One

ORLAND FOLLOW PR-1211

PRELIMINARY MANUAL STAGE COLOR 48. Preliminary User Guide. Official version will follow soon on: TABLE OF CONTENTS

INFRARED QUARTZ WALL HEATER

Light Source User Guide

K E E P E TH T I H S I MA M N A U N A U L A FO F R

ComPar KIT 1 & 2 DMX LED light set

ORDER DIRECTLY TODAY AT: or CALL TOLL FREE Foglio di Istruzioni Owner s manual IMPERIAL. GR 0035 Xenon 4000

5W LED Energy Saver PIR Bulkhead

Acrobat. user manual

TABLE OF CONTENTS. 6. Technical Specifications Page 2 of 20 COLORband PiX User Manual (Rev. 02)

Contact Details. Please note that some of the contact details on this PDF document may not be current.

Snapshot. LEDrain 38 USER MANUAL. Ok on Dimmer. Outdoor OK. Sound Activated. DMX/Master/Slave. 115V/230V Switch. Replaceable Fuse.

1. BEFORE YOU BEGIN INTRODUCTION SETUP AC POWER... 7 Power Linking... 7 MOUNTING... 8 Orientation... 8 Rigging...

V94 BULK TAPE DEGAUSSER

Ref. Nr LCP-288 LED COLOR PANEL 288X LED 5MM MANUAL

Mania SCX500. user manual

LEDPAR64 USER MANUAL

DP-DMX20L 4 CHANNEL DMX DIMMER PACK MODE MENU DISPLAY. OUTPUT: 10A/CH, TOTAL 20A Max. DMX CHANNEL RECEIVE TOTAL DMX CHANNEL DIMMER / SWITCH

Operating Instructions Bedienungsanleitung Mode d emploi

NSI DIGITAL DIMMING SYSTEM DDS 9800 DIMMER PACKS

TABLE OF CONTENTS. Returns Contact Us... 20

K E E P E TH T I H S I MA M N A U N A U L A FO F R

REB 1 REB 3 REB 5 REB 6 REB 8 REB 10 REB 12 REB 16

Snapshot. User Manual. Use on Dimmer. Outdoor Use. Sound Activated DMX. Master/Slave Autoswitching Power Supply Replaceable Fuse.

FLUORESCENT UV- RING LIGHT OPERATING INSTRUCTION

LED Cube Direct Control 30 ORDERCODE 41131

Trade of Electrician. Three-phase Distribution Boards And Socket Circuits

19 LED Tube Controller ORDERCODE 41003

Floodlight Range Installation Guide

LUCCI AIRFUSION QUEST II CEILING FAN

HID H4 BI-XENON FITTING GUIDE. Carefully read the following notes before starting work.

1. Dispacking. 2. Safety Instructions

Rapide Inline Ceiling Extractor Fan, White Fascia Rapide Inline Ceiling Extractor Fan, Chrome Fascia

Wolflite Safety Handlamp H-251E

ITA3D 710. RGB DMX laser with 3D effect. User manual

VX 2400 Dimmer User's Manual

50W/100W LED Zoom User Manual

Mureva Assembly surface mounted wiring devices

USER MANUAL PLEASE KEEP THIS FOR FUTURE USE

AN500T, AN1000, AN1000T, AN1500, AN1500T AN2000, AN2000T

EtherNet-RS232/485. London Electronics Limited. Ethernet to RS232 or RS485 data converter. Connection details and general information

Moving Head - One Signal Cable - One Omega Clamp One Power Cable - One Safety

Operating Instructions

TMS TANK MANAGEMENT SYSTEM

Four Way 220 LED DMX Moonflower

OPERATING INSTRUCTIONS

American DJ. User Instructions. American DJ

60W PIR BULKHEAD LIGHT SLB88-Black/SLW89-White INSTALLATION & OPERATING INSTRUCTIONS

EPM3. Phase Sequence and Motor Rotation Tester. Users Manual

EVC40 EMERGENCY VOICE COMMUNICATION SYSTEM

IS200-MH. User Manual. 10. Specifications. Input Voltage: AC90-260V 50/60Hz. LED Quantities: 1*150W High brightness white LED unit

Please also see 10 golden rules for correct Saniflo installation on

2XWSXWFKDQQHOV 3KDVH &+ CH 2 &+ CH 4 &+ CH 6 L1 X X L2 X X L3 X X

Bubble King. User Manual

Operating instructions Diffuse reflection sensor. OJ50xx / / 2004

USER INSTRUCTIONS FOR 10 LITRE PORTABLE DEHUMIDIFIER MODEL NO. DHMD102

Operating instructions Capacitive sensors

American DJ. User Instructions

BSE Geluid en Licht Pagina 1 van 5. Description

2400W PIR LIGHT C O N T R O L L E R Cat No. SLW2400

1. BEFORE YOU BEGIN INTRODUCTION SETUP... 6

CR Band Auto Set Dual Alarm Clock Radio ROBERTS. Sound for Generations. Please read this manual before use

TIG INVERTER INSTRUCTION MANUAL

ComPar KIT 1 & 2 DMX LED light set with power outputs

PART 1 PRODUCT (GENERAL)...1.

Product and Applications Description. Application Programs. Example of Operation. GAMMA instabus Technical Product-Information.

M A R C O. CP-670 AUTOMATIC CHART PROJECTOR Instruction Manual

Current valve. for AC 24 V pulse/pause control of electrical loads up to 30 kw

CB-100 LED Color Beam LED spotlight. user manual

CX Zoner Installation & User Guide

Meaco 30L and Meaco 40L dehumidifier instruction manual

Solar Home System. User Manual. AEH-SHS01-10W2L Solar Home System 2 Lamps

FT-100 Fire Training Fog Machine User Manual English

Bathroom Cabinet. Installation & User Guide. Illuminated Mirrors.

MAC Viper Quadray Module Installation and Control Guide

Warning! To prevent or reduce the risk of electrical shock or fire, do. Caution! There are no user serviceable parts inside this unit.

PS 155 WIRELESS INTERCOM USER MANUAL

User s Manual Before using the inverter, you need to read and save the safety instructions.

Table of Contents. What to Expect with. Preparation. Tools Needed. Wiring. Hanging the Fan. Blades. Motor Housing.

Sunstrip Active DMX ORDERCODE 30710

RE-3 : SOLID TOP RANGE RANGE TOP ONLY

ADM1TE 5/30A DIN rail single phase two wire energy meter

3 IN 1 BATHROOM HEATER

LED PAR 64 SHORT FLOOR 20X3W PWM RGB

MADRIX NEO Quick Start Guide & User Manual

Product and functional description

Hot Water Urns. all models. Helpline. v3.0

Medical Lighting. XL4 Patient Light

13 Watt PORTABLE SOLAR POWER KIT

- Designed to meet with the environmental stresses of ships and heavy industry. SESOBS

This unit is a pump that will clear the waste from a domestic shower and washbasin, bath, washing machine, glass washer and a sink.

PG_IM_A.indd 1 23/06/ :22

LED Par 56 Short DMX ORDERCODE 42421

SUB Universal water baths SBB Boiling baths JB, PB Unstirred water baths

LASER SHOW SYSTEM LUNA. User's Manual

Handheld portable appliance testers

SYSTEM 45. C R H Electronics Design

Gemini II. Subwoofer System OWNERS MANUAL

Transcription:

IMPORTANT Installer and Users please note: These instructions should be read carefully and left with the user of the product for future reference. Installation Fix the DMX50 with the hanging bracket provided. To conform to Health & Safety Regulations, a safety wire must also be employed. The DMX50 must be installed by a competent electrician in accordance with the current IEE wiring regulations. Connect the DMX50 to the mains supply with the lead provided. The wires are colour-coded as follows: Brown = Live (phase) Blue = Neutral Green/Yellow = Earth The DMX50 must be earthed for safe and reliable operation. The supply must be fitted with an isolating switch, or plug and socket, and protected by fuse or circuit breaker rated at between 6A and A. If the DMX50 circuit is connected via an MCB then it is recommended that a time-delay MCB is used (Type 3 or Type C to BS371). This will reduce the possibility of "nuisance tripping" due to the large inrush current of the halogen lamp. This symbol means that in order to reduce the risk 0.m of fire, the DMX50 should be installed more than 0. metres from any object that it is illuminating. It is also possible to connect the DMX50 to a switching pack such as the NJD SP10000 but this is not recommended. If connecting via a power pack, the outputs of the power pack should be de-rated by 50% from its resistive load capacity to allow for the large inrush current of the halogen lamp. The DMX50 should not be connected to a dimming pack or light dimmer. The DMX50 is an inductive load. N.J.D. Electronics 005 -Page -

Adjust the hanging bracket until the light beams are in the best position. The DMX50 may be moved whilst it is operating provided that it is done carefully, the lamp is most vulnerable mechanical damage immediately after it has been switched off, before it has fully cooled. It is recommended that the DMX50 is allowed to cool for 5 minutes after switching off before moving. Changing the lamp. Disconnect from the mains supply. Unscrew the fixing knob from the lamp cover on the front of the product and withdraw the lamp assembly. Remove the lamp from the fixing clip and remove the connector from the lamp. Replace with a new lamp, type A1/ 59, being careful not to touch the glass envelope of the lamp. Connect the lamp connector to the lamp and replace in the fixing clip. Replace the lamp cover and tighten the fixing knob. Changing the fuse. Occasionally, when the lamp fails the fuse may also blow. If this occurs, replace with a new fuse type 0mm 5mm 3.15 Amp antisurge, high breaking capacity. This type of fuse has a ceramic case. Do not replace with any other type or value of fuse. If the new fuse blows consult a dealer. The fuse is located next to the incoming mains cable. Focusing. To focus slacken the focusing control on the front of the unit, move forwards or backwards as required, and re-tighten the screw when the best image is obtained. Cleaning. The DMX50 should be cleaned periodically as the light output will become less intense as smoke fluid residues build up on the mirror and lenses. Disconnect from the mains supply and remove the cover. Clean the lens and the mirror using a soft lintfree cloth and methylated spirit, isopropyl alcohol or hi-fi cleaning fluid. Also, make sure that the fan is not becoming obstructed - use a brush to remove any build-up of dust. N.J.D. Electronics 005 -Page 3-

Connection. Connect the DMXcon1 to the DMX50 using the RJ11 to 5- pin XLR lead provided. Connect the two DMX50s together using the 5-pin XLR male to female lead provided. Setting up Note: all diagrams show switches up as OFF and down as ON. 1. To make all scanners operate identically. Set all address switches OFF. Set the "Master/slave" switch ON. Set the "Terminator" switch OFF on DMX ADDRESS all scanners except the last on in the chain. On the last scanner in the chain, set the "Terminator" switch ON. This correctly terminates the DMX line, DMX ADDRESS preventing interference and data errors. On earlier scanners fitted with ¼" jacks, there are no switches labelled Master/Slave and Terminator. This is set automatically by the scanner. If the scanners are facing each other, then it is possible to reverse the direction of beam movement of one unit, so that the movement of beams in the air is the same. To do this, set the switch labelled X-reverse ON. If all the scanners are operating identically then the full range of functions of the DMXcon1 will not be available.. To obtain sequenced movement and colour changing patterns on two scanners. On the first scanner: Set all address switches OFF. Set the "Master/slave" switch ON. DMX ADDRESS Set the "Terminator" switch OFF 3 3 3 6 6 6 1 1 1 N.J.D. Electronics 005 -Page -

On the second scanner: Set all address switches OFF except for "" DMX ADDRESS Set the "Master/slave" switch ON. Set the "Terminator" switch ON. If the scanners are facing each other, then it is possible to reverse the direction of beam movement of one unit, so that the movement of beams in the air is the same. To do this, set the switch labelled X-reverse ON. If adding more scanners at a later date. To obtain sequenced movement and colour changing patterns on four or more scanners. If using more than four scanners, then for each scanner, choose whether it will be channel 1,, 3 or. On all scanners allocated to channel 1 Set all address switches OFF. Set the "Master/slave" switch ON. DMX ADDRESS Set the "Terminator" switch OFF unless it is the last scanner in the chain, in which case, set it ON. On all scanners allocated to channel Set the address switches as shown. Set the "Master/slave" switch ON. DMX ADDRESS Set the "Terminator" switch OFF unless it is the last scanner in the chain, in which case, set it ON. On all scanners allocated to channel 3 Set the address switches as shown. Set the "Master/slave" switch ON. DMX ADDRESS Set the "Terminator" switch OFF unless it is the last scanner in the chain, in which case, set it ON. 3 3 3 3 6 6 6 6 1 1 1 1 N.J.D. Electronics 005 -Page 5-

On all scanners allocated to channel Set the address switches as shown. Set the "Master/slave" switch ON. DMX ADDRESS Set the "Terminator" switch OFF unless it is the last scanner in the chain, i- n which case, set it ON. Sound activation. The DMXcon1 has a built-in microphone and needs no connection to the sound source, 3 6 1 N.J.D. Electronics 005 -Page 6-

Operation SIZE Size. 50% Off. The lamps are switched off, but motors are kept in position, to avoid the 5% need for the startup procedure next time Off 100% the DMX50 is required. 5sec sec 5%/50%/100%. This control adjusts 10sec 1sec the maximum angle over which the 15sec Sound 0.5sec beams scan, so that the effect can be COLOUR Red Blue kept with the bounds of a stage or dance Green White Pink Sync floor. Cyan Random Yellow Fill Colour control. Magenta Shift This sets the colour. Sync, Random, Fill PATTERN 6 7 5 and Shift are colour changing patterns. 9 To display these patterns, two or more 3 10 11 scanners are required. If set so that "all 1 1 scanners operate identically" this SPEED 3 patterns will not be displayed. The colour speed control (above the 5 1 colour control) sets the time interval Sound 6 between changes of colour. If set to "sound", colours change to the beat of the music. DMXcon1 Sync. A new colour is chosen at DMX Scanner Controller random, all four scanners are set to this NJ11D N.J.D. ELECTRONICS. colour. MADE IN CHINA. Random. All four scanners are different random colours. Fill. A new colour is chosen at random, this colour is displayed on the first scanner, followed by the second after the set time interval, followed by the third and the fourth. At that point all scanners will be displaying the same colour. After the next time interval, a new colour is chosen and the sequence repeats. Shift. A new colour is chosen at random, this colour is displayed on the first scanner. After the set time interval, the colour from the first scanner is transferred to the second, the N.J.D. Electronics 005 -Page 7-

colour from the second scanner is transferred to the third etc, and a new colour is chosen for the first scanner. Pattern Control. The DMXcon1 can display twelve different scanning patterns, including horizontal and vertical lines, triangles, circles, squares, stars and figures of. Speed control This sets the speed at which the scanner draws the pattern. If set to sound, the light beam will move a small distance on each bass beat and then remain still until the next bass beat. N.J.D. Electronics 005 -Page -

Fault Finding No operation: Plugs not fully pushed into sockets DIL switches set to wrong address, must be 1, 5, 9 or 13. Size control set to OFF. Sync, Random, Fill and Shift do not operate: Scanners all set the same DMX channel Repairs and spare parts. If you require spare parts or to return the unit for repair, please contact. technical@njd.co.uk Part numbers for replacement leads or leads of different lengths are as follows: RJ11 to XLR: NJ310 3m XLR to XLR: G03VH 6m XLR to XLR: G03VJ 10m XLR to XLR: G03VK Standards The DMX50 complies with the following British and European Standards: BS EN55015 - Electromagnetic Compatibility. BS EN6059 - Electrical Safety Standard for Luminaires. The DMXcon1 is a CLASS III product (Protection by Safety Extra Low Voltage) and is exempt from electrical safety standards, and complies with Electromagnetic Compatibility Standard EN55103. N.J.D. Electronics 005 -Page 9-

DMX50 Power supply: Fuse: Technical Specification. 30V nominal @ 50Hz 300VA (1.5A) 10V minimum 55V maximum. T3.15A (3.15 Amp anti-surge) 5 0mm HBC to BS65/IEC17 A HBC fuse has a ceramic case. Switch-on surge:.1a (90VA) Duration: 60ms (3 mains cycles) Lamp: A1/59 (ELC) V 50W dichroic reflector Colours: 7 dichroic plus white Gobos: 7 Beam intensity: 0,000 candela Lamp life: 100 hours nominal @ 30V AC Note: Although Britain has had a 30V mains supply since January 1st 1995, the voltage is usually 0V. 60 hours nominal @ 0V AC Beam width: 60mm diameter at 1 metre (3" diameter at 1 foot) Beam Angle: 15 Motors: Unipolar Hybrid stepper: microstepping Microstep size: 6'5" (1.95mrad) DMX input/output: complies with DMX51 (1990) µsec and EIA RS-5 Connectors: 5-pin XLR Data+: Pin 3 Data-: Pin Earth: Pin 1 +1V output: Pin 5 A +1V output is provided on Pin 5 to run controllers. N.J.D. Electronics 005 -Page 10-

DMXcon1 Dimensions: Weight: Power Supply: Output: Connections: 1mm x 65mm x 37mm 0.3kg 1V DC @ 15mA DMX51 (conforms to electrical and data specifications) RJ11 N.J.D. Electronics 005 -Page 11-

Guarantee This product is guaranteed for a period of 1 months against faulty components or manufacture from the date of purchase. Upon proof of purchase, NJD shall, at its own option, repair or replace the defective item at no cost to the purchaser. This guarantee is contingent upon the proper use of the product in the application for which it is intended and does not cover products that have been modified, subjected to unusual physical conditions, or electrical conditions outside its specification, or damaged in any way. This guarantee is limited to the product only and does not cover carriage costs, installation costs or travel expenses. Your statutory rights are not affected. In the event of any problems with this product contact the retailer from which it was purchased for technical assistance, or e-mail technical@njd.co.uk NJD Products are distributed by: Electrovision Ltd., Lancots Lane, Sutton Oak, St. Helens, Merseyside, England. WA9 3EX Telephone: + 17 75000 Fax: + 17 7500 E-mail: sales@electrovision.co.uk Web sites: www.njd.co.uk www.electrovision.co.uk Copyright N.J.D. Electronics. Neither the whole nor any part of the information contained in, nor the product described in this User Guide may be adapted, copied or reproduced in any form except with the prior written approval of N.J.D. Electronics. N.J.D. Electronics 005 -Page 1-