Precast concrete structures are used worldwide because

Similar documents
SEISMIC DESIGN. Various building codes consider the following categories for the analysis and design for earthquake loading:

Draft Table of Contents. Building Code Requirements for Structural Concrete and Commentary ACI

Requirements for the Use of PRESSS Moment-Resisting Frame Systems

EXPERIMENTAL INVESTIGATION INTO THE SEISMIC PERFORMANCE OF HALF- SCALE FULLY PRECAST BRIDGE BENT INCORPORATING EMULATIVE SOLUTION

Detailing of Reinforcment in Concrete Structures

4B The stiffness of the floor and roof diaphragms. 3. The relative flexural and shear stiffness of the shear walls and of connections.

Technical Notes 3B - Brick Masonry Section Properties May 1993

SEISMIC DESIGN PROVISIONS FOR PRECAST CONCRETE STRUCTURES. S.K. Ghosh, Ph. D. President S.K. Ghosh Associates Inc. Northbrook, IL BACKGROUND

ANALYSIS FOR BEHAVIOR AND ULTIMATE STRENGTH OF CONCRETE CORBELS WITH HYBRID REINFORCEMENT

SEISMIC RETROFITTING TECHNIQUE USING CARBON FIBERS FOR REINFORCED CONCRETE BUILDINGS

REHABILITATION OF THE FIGUEIRA DA FOZ BRIDGE

Seismic performance evaluation of an existing school building in Turkey

Analysis and Repair of an Earthquake-Damaged High-rise Building in Santiago, Chile

USE OF CFRP LAMINATES FOR STRENGTHENING OF REINFORCED CONCRETE CORBELS

WI LEY Blackwell. Multi-storey Precast Concrete Framed Structures. Colin K. Jolly MSc, PhD, CEng, MICE, FIStructE

ASSESSMENT AND PROPOSED STRUCTURAL REPAIR STRATEGIES FOR BRIDGE PIERS IN TAIWAN DAMAGED BY THE JI-JI EARTHQUAKE ABSTRACT

Chapter 5 Bridge Deck Slabs. Bridge Engineering 1

In-situ Load Testing to Evaluate New Repair Techniques

SMIP05 Seminar Proceedings VISUALIZATION OF NONLINEAR SEISMIC BEHAVIOR OF THE INTERSTATE 5/14 NORTH CONNECTOR BRIDGE. Robert K.

bi directional loading). Prototype ten story

Cover. When to Specify Intermediate Precast Concrete Shear Walls Rev 4. White Paper WP004

Objectives. Experimentally determine the yield strength, tensile strength, and modules of elasticity and ductility of given materials.

Miss S. S. Nibhorkar 1 1 M. E (Structure) Scholar,

Incorporating Innovative Materials for Seismic Resilient Bridge Columns

Numerical modelling of shear connection between concrete slab and sheeting deck

Design of reinforced concrete columns. Type of columns. Failure of reinforced concrete columns. Short column. Long column

DESIGN OF BLAST RESISTANT BUILDINGS IN AN LNG PROCESSING PLANT

SEISMIC UPGRADE OF OAK STREET BRIDGE WITH GFRP

Page 1 of Sven Alexander Last revised SB-Produksjon STATICAL CALCULATIONS FOR BCC 250

Design and Construction of Cantilevered Reinforced Concrete Structures

Performance of Existing Reinforced Concrete Columns under Bidirectional Shear & Axial Loading

Hybrid simulation evaluation of the suspended zipper braced frame

SECTION 7 Engineered Buildings Field Investigation

TECHNICAL NOTE. Design of Diagonal Strap Bracing Lateral Force Resisting Systems for the 2006 IBC. On Cold-Formed Steel Construction INTRODUCTION

EVALUATION OF SEISMIC RESPONSE - FACULTY OF LAND RECLAMATION AND ENVIRONMENTAL ENGINEERING -BUCHAREST

Optimum proportions for the design of suspension bridge

PRESTRESSED CONCRETE. Introduction REINFORCED CONCRETE CHAPTER SPRING Reinforced Concrete Design. Fifth Edition. By Dr. Ibrahim.

Seismic Retrofit of Reinforced Concrete Beam- Column T-Joints in Bridge Piers with FRP Composite Jackets

Hardened Concrete. Lecture No. 14

FUTURE SLAB. PENETRATIONS and. DEMOLITION of POST-TENSIONED FLOORS

INTRODUCTION TO BEAMS

DESIGN OF SLABS. 3) Based on support or boundary condition: Simply supported, Cantilever slab,

DEVELOPMENT OF A NEW TEST FOR DETERMINATION OF TENSILE STRENGTH OF CONCRETE BLOCKS

SPECIFICATIONS, LOADS, AND METHODS OF DESIGN

THE EFFECT OF STIRRUPS AND HOOKED STEEL FIBERS INSTEAD ON MOMENT-ROTATION CAPACITY OF BEAM-COLUMN CONNECTIONS

METHOD OF STATEMENT FOR STATIC LOADING TEST

Prepared For San Francisco Community College District 33 Gough Street San Francisco, California Prepared By

Chapter 3 DESIGN AND CONSTRUCTION FEATURES IMPORTANT TO SEISMIC PERFORMANCE

INSTRUCTIONS FOR USE

Precast Concrete Parking Structures

BEHAVIOR OF WELDED T-STUBS SUBJECTED TO TENSILE LOADS

Comparison of Seismic Performance of D-region of Existing RC Structures Designed with Different Recommendations

1.2 Advantages and Types of Prestressing

CYCLIC LOAD TESTING OF PRECAST HYBRID FRAME CONNECTIONS

9.3 Two-way Slabs (Part I)

Seismic Risk Prioritization of RC Public Buildings

Modern Codes for Design of Concrete Concrete Structures Presentation Outline

P4 Stress and Strain Dr. A.B. Zavatsky MT07 Lecture 3 Statically Indeterminate Structures

Nonlinear numerical analysis of SRC-RC transfer columns based on OpenSEES

Guidelines for the Design of Post-Tensioned Floors

SEISMIC RETROFIT DESIGN CRITERIA

National Council of Examiners for Engineering and Surveying. Principles and Practice of Engineering Structural Examination

Tension Development and Lap Splice Lengths of Reinforcing Bars under ACI

SEISMIC REHABILITATION OF COLUMN TO PIER CAP ACCELERATED BRIDGE CONSTRUCTION CONNECTIONS AND ACOUSTIC EMISSION MONITORING ASSESSM ENT

Seismic design of beam-column joints in RC moment resisting frames Review of codes

REINFORCED CONCRETE. Reinforced Concrete Design. A Fundamental Approach - Fifth Edition. Walls are generally used to provide lateral support for:

SEISMIC RETROFITTING OF EARTHQUAKE-DAMAGED CONCRETE COLUMNS BY LATERAL PRE-TENSIONING OF FRP BELTS. K. Nasrollahzadeh Nesheli 1 and K.

Reinforced Concrete Design

SECTION 5 ANALYSIS OF CONTINUOUS SPANS DEVELOPED BY THE PTI EDC-130 EDUCATION COMMITTEE LEAD AUTHOR: BRYAN ALLRED

A transverse strip of the deck is assumed to support the truck axle loads. Shear and fatigue of the reinforcement need not be investigated.

Methods for Seismic Retrofitting of Structures

DESIGN OF PRESTRESSED BARRIER CABLE SYSTEMS

Seismic Risk Evaluation of a Building Stock and Retrofit Prioritization

Retrofitting By Means Of Post Tensioning. Khaled Nahlawi 1

APE T CFRP Aslan 500

TECHNICAL SPECIFICATION SERIES 8000 PRECAST CONCRETE

SECTION 3 DESIGN OF POST- TENSIONED COMPONENTS FOR FLEXURE

Design of Steel Structures Prof. S.R.Satish Kumar and Prof. A.R.Santha Kumar. Fig some of the trusses that are used in steel bridges

Untopped Precast Concrete Diaphragms in High-Seismic Applications. Ned M. Cleland, Ph.D., P.E. President Blue Ridge Design, Inc. Winchester, Virginia

Control of Seismic Drift Demand for Reinforced Concrete Buildings with Weak First Stories

Design Parameters for Steel Special Moment Frame Connections

LARGE SCALE TENSILE TESTS OF HIGH PERFORMANCE FIBER REINFORCED CEMENT COMPOSITES

ABSTRACT 1. INTRODUCTION 2. DESCRIPTION OF THE SEGMENTAL BEAM

Seismic Assessment and Retrofitting of Structures: Eurocode8 Part3 and the Greek Code on Seismic Structural Interventions

CONCRETE CHAPTER 19. Italics are used for text within Sections 1903 through 1908 of this code to indicate provisions that differ from ACI 318.

! # # % % & () +, & +,,. / 0 % % ) () 3

PERFORMANCE OF SLABS REINFORCED BY PEIKKO PSB STUDS

Concrete Design Manual

CH 6: Fatigue Failure Resulting from Variable Loading

Deflections. Question: What are Structural Deflections?

BRIDGE DESIGN SPECIFICATIONS APRIL 2000 SECTION 9 - PRESTRESSED CONCRETE

4 SENSORS. Example. A force of 1 N is exerted on a PZT5A disc of diameter 10 mm and thickness 1 mm. The resulting mechanical stress is:

EXPERIMENTAL AND NUMERICAL ANALYSIS OF THE COLLAR PRODUCTION ON THE PIERCED FLAT SHEET METAL USING LASER FORMING PROCESS

Statics of Structural Supports

SECTION 3 DESIGN OF POST TENSIONED COMPONENTS FOR FLEXURE

Design of Fibre Reinforced Concrete Beams and Slabs

BEHAVIOR OF SHORT CONCRETE COLUMNS REINFORCED BY CFRP BARS AND SUBJECTED TO ECCENTRIC LOAD

SLAB DESIGN. Introduction ACI318 Code provides two design procedures for slab systems:

Performance-based Evaluation of the Seismic Response of Bridges with Foundations Designed to Uplift

Transcription:

Seismic performance and retrofit of precast concrete grouted sleeve connections Andrea Belleri and Paolo Riva Precast concrete structures are used worldwide because of their shorter construction time, cost effectiveness, and better plant control of structural elements and materials compared with cast-in-place concrete structures. In Italy, the most common applications of precast concrete buildings are industrial warehouses and commercial malls. The typical structural layout of these buildings consists of cantilever columns connected by simply supported precast, prestressed concrete beams that support prestressed concrete roof elements. The columns are inserted and grouted in place in isolated precast concrete socket foundations. Experimental tests on the cyclic behavior of column-to-foundation subassemblies were conducted to compare the response of grouted sleeve connections with those of cast-in-place and pocket-foundation connections. Confinement by the grouted sleeves inhibited buckling of the longitudinal reinforcement and increased the compressive strength of the grout. The damage was localized to the column base, allowing easier postseismic column repair compared with traditional connections. This structural layout reduces construction time and is cost effective. However, this effectiveness could be compromised for construction in seismic regions, especially if the design follows the capacity design rule. The design of column footings is based on the assumption that a plastic hinge may develop at the column base in an earthquake event, while capacity design is used to prevent the formation of an inelastic mechanism in the footing. The latter goal is achieved by considering the bending moment associated with the column base flexural capacity acting on the foundation amplified by an overstrength factor. Following this design approach, the foundation base becomes large, PCI Journal Winter 212 97

even for medium-sized columns. This could limit the cost effectiveness of industrial and commercial precast concrete structures. In fact, because of the foundation s dimension, the footings must be cast-in-place concrete, making the use of isolated socket foundations less attractive. Hence, mat foundations are more convenient than isolated footings. When using mat foundations, the following column-to-foundation connections are typically used: 1 3 bolted base plates embedded in the foundation foundation pockets in which the columns are placed and grouted grouted sleeves mechanical splices This paper investigates the behavior and performance of grouted corrugated steel sleeve connections under cyclic loading. While the behavior of precast concrete socket base connections is well documented, 4 6 no published experimental results concerning the cyclic response of grouted sleeve column-to-foundation connections have been found. Although temporary bracing is needed for erection stability, grouted steel sleeves are an inexpensive type of connection, especially if the retrofit after a seismic event is considered. The confinement provided by grouted steel sleeves inhibits buckling of the longitudinal reinforcement and increases the strength of the grout. As a result, the damage associated with this kind of connection is localized to the column base, allowing easier postseismic column repair compared with traditional connections. Another advantage of grouted steel sleeve connections compared with modern mechanical splice devices is the ability to include an unbonded portion in the reinforcing bar inside the sleeves. This distributes the reinforcing bar deformation over the unbonded length, increasing the ultimate rotation capacity of the subassembly and reducing the reinforcement strain demand for a given column drift (defined as the interstory displacement divided by the interstory height). This advantage is not typical of mechanical splice devices. The unbonded length of the reinforcement can be taken into account in the design process by considering an appropriate plastic hinge length. The responses of five columns subjected to a cyclic top horizontal displacement history were investigated considering different connection details. The cyclic behavior of a grouted corrugated steel sleeve connection with partly unbonded bars in the sleeves was investigated and compared with the cyclic behavior of the same specimen after retrofitting. Experimental program Test setup This experimental program included six tests: one on each of five specimens with different column-to-foundation connections and approximately the same maximum bending moment capacity and a test on one of the original specimens after retrofitting. The columns had cross sections of 4 mm 4 mm (16 in. 16 in.) and heights of 32 mm (126 in.). Two hollow-core plunger jacks applied a constant axial force of 6 kn (14 kip) to all columns. The axial force represents a gravity load compatible with the structural framing system. An electromechanical screw jack with a 5 mm (2 in.) maximum stroke and 1 kn (225 kip) capacity applied a cyclic horizontal displacement at the top of the column, imposing an increasing column drift from.25% to 5%. Figure 1 shows the test setup. The horizontal loads and displacements were recorded by a load cell and a string pot transducer, respectively, while three pairs of linear displacement transducers evaluated the average column curvature recorded at three consecutive levels of the column base (Fig. 2). The lower pair of displacement transducers was connected directly to the foundation. Therefore, the average curvature evaluated comprises the strain penetration of the reinforcing bars into the foundation block. Figure 3 shows the geometry of the tested specimens. Specimen CP represented a typical cast-in-place concrete column-to-foundation connection, and specimen PF represented a typical grouted pocket foundation with no extra roughening of the surfaces at the column and foundation interface. Specimens GS4 and GS4B both had four grouted sleeves, but each specimen had a different anchorage length of the reinforcing bars in the foundation. The specimen GS4 had 9 hooks at the reinforcing bar ends, whereas GS4B had straight reinforcing bars, which represented a connection sometimes adopted to increase construction speed. Specimen GS4U was equal to specimen GS4B with an additional 3 mm (12 in.) unbonded length on the spliced reinforcing bars. Adhesive tape provided the unbonding for these bars. GS4UR was specimen GS4U after retrofitting. The retrofitting sequence consisted of clearing the grout crushed during the previous tests at the column base, placing collar formwork, and filling it with high-strength shrinkage-compensating grout. Material properties All reinforcing steel had a specified yield stress greater than 45 MPa (65 ksi), but an average yield stress of 53 MPa (77 ksi) was recorded. The concrete type was C35/45 (that is, with a specified 28-day cylindrical and cubic compressive strength greater than 35 MPa [5.1 ksi] and 45 MPa [6.6 ksi], respectively). All of the grout that was 98 Winter 212 PCI Journal

Hollow-core plunger jacks for column axial load Electromechanical screw jack (1 kn capacity) Self-equilibrated reaction frame Column-tofoundation subassembly Figure 1. Test setup. Note: 1 kn =.225 kip. used inside the sleeves, retrofitted connection for GS4UR, and pocket foundation PF was a shrinkage-compensating cement-based grout with a maximum aggregate size of 2.5 mm (.1 in.) and a specified 28-day strength greater than 75 MPa (11 ksi). The ducts used for the grouted sleeve connections were typical post-tensioning ducts made with corrugated galvanized strip steel with an 8 mm (3 in.) internal diameter, an 84 mm (3.3 in.) external diameter, and a.6 mm (24-gauge) thickness. Test results Figure 4 shows the experimental horizontal load versus drift curves for the tested specimens. The lateral load was reported as measured by the load cell with no correction for the 2nd order load-displacement effects, indicated by the dashed lines. Any gain or loss of strength is obtained when the experimental curve in absolute terms lies above or below the lines, respectively. Figure 5 shows the horizontal load versus drift comparison between the unbonded grouted sleeve connection before and after retrofitting. Figure 6 shows pictures of the damaged region at the base column corresponding to 5% drift for all tests except GS4UR, which failed at approximately 3.5% drift. The three pairs of linear displacement transducers at the column base side computed the column average curvature at three consecutive levels (low, intermediate, and high) at PCI Journal Winter 212 99

Typical geometry and reinforcing layout 4 mm Typical section AA - grouted sleeves 32 mm Precast concrete column Corrugated steel sleeves Grout A A 25 mm 9 mm 178 mm 22 mm Stirrups 8 mm diameter at 5 mm center to center Stirrups 8 mm diameter at 2 mm center to center Stirrups 8 mm diameter at 1 mm center to center Stirrups 8 mm diameter at 5 mm center to center 5 mm 7 mm 8 mm 16 mm C L 24 mm Displacement transducers at column base 215 mm 215 mm 215 mm 7 mm 5 mm C L 6 mm 8 mm 18 mm diameter 26 mm diameter High Intermediate Low 125 mm 15 mm 125 mm 2 mm Figure 2. Reinforcement layout and instrumentation details. Note: 1 mm =.394 in. 215 mm (8.46 in.) spacing. For each level, the average curvature was computed by dividing the difference between the measurements of the two displacement transducers by the level spacing (215 mm) and by the distance between the transducers (15 mm [5.9 in.]). The curvature computed at the lowest level comprises the strain penetration of the reinforcing bars into the foundation block because the displacement transducers were connected directly to the foundation. The moment-curvature curves (Fig. 7) are the envelope curves for each test, computed as the average of both directions of excitation. The abscissa is made dimensionless by multiplying the curvature by the column cross-section height B (4 mm [16 in.]). Figure 8 shows the dimensionless energy for each test in the drift range from 1% to 5%. The dimensionless energy is defined as the ratio between the hysteretic energy (area inside each complete force-displacement cycle) and the corresponding elastic energy in a semicycle (defined as one half of the maximum displacement times the corresponding lateral force), which accounts for the equivalent horizontal load due to the effect. Analysis of results As expected, all of the columns had almost the same maximum lateral force capacity, though some differences arose due to misalignment of the reinforcing bars during construction. The cast-in-place concrete column specimen CP failed at 5% drift due to the tensile failure of one of the reinforcing bars. This is likely due to low-cycle fatigue of the bar and localized strain at the column base where a major crack opened (Fig. 6). The column cyclic behavior was stable up to 2.5% drift, and no damage other than base concrete spalling was observed. Significant pinching was present in the cycles after 2.5% drift. The grouted pocket foundation specimen PF showed a stable response though a small amount of strength degradation was registered in one loading direction after 3% drift. 1 Winter 212 PCI Journal

Specimen CP Section A-A Specimen PF Section A-A 4 mm A A A A 4 mm 8 mm 8 mm 24 mm 8 mm 8 mm 24 mm Grout Specimen GS4 Section A-A Specimen GS4B Section A-A 4 mm A A A A 4 mm 8 mm 8 mm 24 mm Grout 8 mm 8 mm 24 mm Grout Specimen GS4U Specimen GS4UR 4 mm Section A-A A A A A 3 mm Repair collar unbonded 4 mm Section A-A 8 mm 8 mm 24 mm Grout 8 mm 8 mm 24 mm Grout Figure 3. Details of column-to-foundation connections. Note: 1 mm =.394 in. In the same loading direction fatter hysteresis half loops were observed compared with the other loading direction. This asymmetry was probably due to imperfect centering of the column in the pocket foundation. Compared with others, specimen PF showed a more pronounced extension of flexural cracks at the column base (Fig. 6), spreading along a length approximately equal to the column base dimension. Specimens GS4 and GS4B showed a stable hysteretic response, though specimen GS4 showed some strength degradation starting at 2% drift. This was likely due to longitudinal reinforcement slippage in the foundation block. Specimen GS4 resembled a connection sometimes PCI Journal Winter 212 11

1 Specimen CP 1 Specimen PF 5-5 Bar failure 5-5 -1-6 -3 3 6-1 -6-3 3 6 1 Specimen GS4 1 Specimen GS4B 5-5 5-5 -1-6 -3 3 6-1 -6-3 3 6 1 Specimen GS4U 1 Specimen GS4UR 5-5 5-5 Bar failure -1-6 -3 3 6-1 -6-3 3 6 Figure 4. Lateral load versus column drift for the different connection types. Note: P- = 2nd order load-displacement effects. adopted in practice to increase construction speed even if full anchorage strength of the splice reinforcement is not provided. As expected, the limited anchorage length resulted in strength degradation in the cyclic response. This degradation is negligible for drift values smaller than 2.5%, a value over which considerable damage is expected in nonstructural members, such as cladding panels. The use of grouted steel sleeves on the column induced a major crack opening at the grout layer beneath the sleeves. The compressive strain concentration at the column base led to progressive damage at the unconfined grout next to 12 Winter 212 PCI Journal

the steel sleeves. After crushing, the damaged grout was expelled from the column base, leaving the role of resisting compressive forces associated with cyclic bending to only the confined grout in the steel sleeves and the vertical reinforcing bars. On the other end, grouted steel sleeve specimens showed no other noticeable sign of damage. Compared with traditional connections (specimens CP and PF), a slightly more pronounced pinching was observed in the cycles of GS4 and GS4B. This was due to the progressive damage of the base grout layer, which led to a larger strain localization at the column base. For these specimens, the test was extended to 6.5% drift with no reinforcing bar failure. The higher displacement capacity recorded was due to the confinement induced by the steel sleeves on the grout. Although the localized strain at the base of specimens GS4 and GS4B could lead to a failure of the columns, the existence of confined grout regions within the sleeves effectively prevented an early failure of the connections. Furthermore, the grouted sleeves prevented buckling of the vertical bars anchored in the foundation. Because the damage was limited to the grout layer existing at the base and the remaining part of the column was mostly undamaged, it is concluded that the grouted steel sleeve connections are easier to repair after a seismic event than the traditional connections (specimens CP and PF). The same observations and considerations made for specimens GS4 and GS4B apply to specimen GS4U. The addition of an unbonded length in the reinforcement inside the grouted steel sleeves further reduced the column damage. The constant strain distribution in the unbonded region led to a rigid rotation at the column base, which reduced the reinforcing bar strain required to reach the same column top displacement compared with specimens GS4 and GS4B. After reaching 5% drift, specimen GS4U was retrofitted and became specimen GS4UR. Figure 5 compares specimen GS4U with its retrofitted connection specimen GS4UR. The cyclic response of the two specimens is similar up to 3% drift. At 3.5% drift, a bar failed in specimen GS4UR. This failure was likely due to low cycle fatigue of the reinforcing bar, considering the number of cycles experienced by the specimen during both tests. From the moment-curvature envelope curves for each test (Fig. 7), the following observations were made: In the high level (Fig. 2), all of the specimens behaved as linear elastic. 1 5-5 GS4UR -1-6 -3 3 6 GS4U Figure 5. Comparison of lateral load column drift between unbonded and retrofitted grouted sleeve solution. Note: = 2nd order load displacement. For all of the tests, the majority of the curvature demand was concentrated at the column base as expected. The average curvature computed in the low level comprises the strain penetration of the reinforcing bars into the foundation. In fact, the displacement transducers were connected directly to the foundation block. The curvature of specimen CP showed a greater localization with respect to that of specimen PF; this led to the early bar failure observed in specimen CP. The curvature values were consistently higher for all of the grouted sleeve specimens than for the cast-inplace and pocket foundation connections. This effect once more demonstrates that a larger localized strain occurred in the grouted sleeve specimens than in the cast-in-place and pocket foundation specimens. Among grouted steel sleeve connections, specimen GS4 had higher curvature values than GS4B because of bar slippage. The unbonded connection of specimen GS4U showed the highest curvature values due to the elongation associated with the constant strain distribution in the unbonded region. Regarding the energy dissipation for each test in the drift range of 1% to 5% (Fig. 8), no significant differences were recorded among specimens CP, PF, GS4, and GS4B, while specimens GS4U and GS4UR showed less energy dissipation because of the rotation at the column base associated with the constant strain in the unbonded region. In the intermediate level, specimen PF was the only specimen to behave inelastically; this is in accordance with the crack pattern in Fig. 6. PCI Journal Winter 212 13

CP PF GS4 GS4B GS4U GS4UR 3.5% Figure 6. Damage at 5% lateral drift. Specimen GS4U was repaired and renamed GS4UR; the latter experienced the failure of one reinforcing bar at a drift of 3.5%. 14 Winter 212 PCI Journal

Considerations on the unbonded length As shown by the experimental results, providing an unbonded length in the longitudinal reinforcement inside the grouted steel sleeves led to a better seismic performance of the column-to-foundation connection compared with traditional connections. The longitudinal reinforcement buckling is inhibited by the confinement provided by the grouted steel sleeves, and the use of an unbonded length of reinforcement leads to an increase in the column displacement capacity. Furthermore, the damage caused by the superimposed cyclic displacement history is limited to the grout layer existing at the base, allowing easier connection repair after a seismic event compared with the other connections analyzed. Having proved the effectiveness of the unbonded length, the next step is to determine how to take it into account in the design process and how to evaluate the column curvature φ and the curvature ductility μ φ for different degrees of lateral displacement. The value of μ φ can be directly implemented in some design procedures based on displacement control. 7 9 To take the unbonded length into account, it is sufficient to add its value to the plastic hinge length L p, that is, the length over which strain and plastic curvature are considered constant and equal to the maximum values at the column base, according to a bilinear idealization of the curvature distribution (Fig. 9). The new plastic hinge length, which accounts for debonding, is calculated by adding the unbonded length L unb to a plastic hinge formulation provided by Priestley et al., 9 leading to Eq. (1). fu L p =.2f - 1 L L L 2L L f p + + $ + (1) c sp unb sp unb where f u = steel ultimate stress f y = steel yield stress y L c = column contraflexure length, corresponding in this case to the column height H L sp = strain penetration length, which takes into account the splice reinforcement tension strain distribution into the foundation 9 where =.15 f y d b if f y is in ksi =.22 f y d b if f y is in MPa d b = reinforcing bar diameter Figure 7. Experimental moment and average curvature response for three displacement transducer positions: low, intermediate, and high. Note: B = column cross-section height. The approximations of the yield Δ y and ultimate Δ u column displacements are obtained by double integration of the idealized curvature distribution. In Δ y evaluation, the rotation associated with the constant strain distribution in the unbonded region needs to be added. In the case of Δ u, this rotation is taken into account directly by the plastic hinge length calculation proposed in Eq. (1). PCI Journal Winter 212 15

E hysteretic / E elastic 3 2.5 2 1.5 1 CP PF GS4 GS4B GS4U GS4UR.5 1. 1. 1. 1.5 2. 2.5 2.5 2.5 3. 3.5 4. 4.5 5. Figure 8. Dimensionless energy of the column-to-foundation connections. Note: E elastic = elastic energy; E hysteretic = hysteretic energy. Beam Roof element Column H Mat foundation Ф y Ф p L SP L P Figure 9. Column-curvature idealization. Note: H = column height; L p = plastic hinge length; L sp = strain penetration length; ø p = column plastic curvature; ø y = column yield curvature. 16 Winter 212 PCI Journal

where Δ y = z H φ y = column yield curvature y 3 2 + z L H (2) y unb Δ u = Δ y + Δ p (3) 1 75 5 25 GS4U GS4B Drift yield (GS4U) Drift yield (GS4B) Drift ultimate (GS4U) Drift ultimate (GS4B) where Δ p = column displacement associated with plastic hinge rotation 2 4 6 8 where = (φ u φ y ) L p H (4) Figure 1. Yield and ultimate drift for the grouted sleeve solution with and without debonding. φ u = column ultimate curvature Equations (2) to (4) were applied to find the yield and ultimate drift associated with specimens GS4B and GS4U, that is, the grouted steel sleeve connection with and without the unbonded region. Figure 1 shows the performance enhancement in terms of displacement capacity increase. The adoption of an unbonded length of reinforcement leads to a reduction of the curvature demand at a given imposed lateral displacement and therefore to a reduction of the column damage that is directly related to the curvature demand. In the case of debonding, the ultimate reinforcing bar capacity is ensured, providing an appropriate development length in addition to the unbonded length. The use of grouted steel sleeves contributes to reducing the development length due to the sleeves ability to restrain the splitting cracks in the grout rather than providing passive confinement. Although the aim of the research is not the determination of the bond strength associated with grouted steel sleeves, the use of the sleeves, especially with debonding, resulted in significant column lateral displacement without reinforcement bar failure. Conclusion The experimental program showed that grouted steel sleeves are suitable as column-to-foundation connections in seismic regions. The high ductility of the grouted steel sleeve connections is related to the confining effect of the corrugated steel sleeves on the grout. Furthermore, the presence of a highly confined grout prevents buckling of the longitudinal reinforcement. In such connections, the damage was localized to the 2 mm (.8 in.) grout layer between the precast concrete column and the foundation. As a result, little damage occurs in the column outside the base section. Due to the damage localization observed, the postseismic column repair for the grouted sleeve connection is simpler than that for cast-in-place concrete or pocket foundation connections and can be effectively done by replacing the base layer of crushed grout with new high-strength grout. To further reduce the column damage and increase the column lateral displacement capacity, an unbonded length of steel reinforcement can be used within the grouted sleeves. The proposed equations make it possible to take into account the unbonded length of reinforcement in the design process and to evaluate the column yield and ultimate displacement when unbonded reinforcing bars are used. Acknowledgments The experimental program reported in this paper was part of a research program on precast concrete column-to-foundation connections financed by Moretti SpA in Erbusco, Italy. The cooperation of Cristian Ratti, Andrea Zini, and Nicola Barzi in setting up the reaction frame and conducting the experimental tests is acknowledged. References 1. fib (International Federation for Structural Concrete) Commission 7. 23. Seismic Design of Precast Concrete Building Structures, International Federation for Structural Concrete. Bulletin 27. Lausanne, Switzerland: fib. 2. PCI Connection Details Committee. 28. PCI Connections Manual for Precast and Prestressed Concrete Construction. 1st ed. Chicago, IL: PCI. PCI Journal Winter 212 17

3. Elliott, K. S. 25. Precast Concrete Structures. Oxford, Great Britain: Elsevier Butterworth-Heinemann. 4. Blandón, J. J., and M. E. Rodríguez. 25. Behavior of Connections and Floor Diaphragms in Seismic- Resisting Precast Concrete Buildings. PCI Journal, V. 5, No. 2 (March April): pp. 56 75. 5. Martins, R., F. Canha, M. K. El Debs, K. de Borja Jaguaribe Jr., and A. L. Homce de Cresce El Debs. 29. Behavior of Socket Base Connections Emphasizing Pedestal Walls. ACI Structural Journal, V. 16, No. 3 (May June): pp. 268 278. 6. Osanai, Y., F. Watanabe, and S. Okamoto. 1996. Stress Transfer Mechanism of Socket Base Connections with Precast Concrete Columns. ACI Structural Journal, V. 93, No. 3 (May June): pp. 1 11. 7. Priestley, M. J. N. 22. Direct Displacement-Based Design of Precast/Prestressed Concrete Buildings. PCI Journal, V. 47, No. 6 (November December): pp. 66 79. P Δ p Δ u Δ y μ φ φ φ p φ y φ u = axial load = 2nd order load-displacement effects = column displacement associated with plastic hinge rotation = column ultimate displacement = column yield displacement = curvature ductility = column curvature = column plastic curvature = column yield curvature = column ultimate curvature 8. Priestley, M. J. N., and D. N. Grant. 25. Viscous Damping, in Seismic Design and Analysis. Journal of Earthquake Engineering, V. 9, Special Issue 2: pp. 229 255. 9. Priestley, M. J. N., G. M. Calvi, and M. J. Kowalsky. 27. Displacement-Based Seismic Design of Structures. Pavia, Italy: IUSS Press. Notation B d b = column cross-section height = reinforcing bar diameter E elastic = elastic energy E hysteretic = hysteretic energy f u f y H L c L p L sp L unb = steel ultimate stress = steel yield stress = column height = column contraflexure length = plastic hinge length = strain penetration length = unbonded length 18 Winter 212 PCI Journal

About the authors Andrea Belleri, PhD, is a postgraduate fellow at the Department of Design and Technologies at the University of Bergamo in Bergamo, Italy. Paolo Riva, PhD, is a full professor in the Department of Design and Technologies at the University of Bergamo. The results demonstrate that grouted sleeves ensure a ductility and energy dissipation capacity similar to those of traditional connections. The confinement provided by the grouted sleeves inhibits buckling of the longitudinal reinforcement and increases the compressive strength of the grout. As a consequence, the damage associated with this kind of connection is localized to the column base, allowing easier postseismic column repair compared with traditional connections. The comparison of the experimental response of a grouted sleeve connection with partly unbonded reinforcement within the sleeves and the same specimen after retrofitting is also included. Keywords Abstract The paper investigates the suitability of grouted sleeve connections as column-to-foundation connections for precast concrete structures in seismic regions. Although grouted sleeves are commonly used, the typical advantages from this connection have not been fully addressed in the literature. Experiments on the cyclic behavior of column-tofoundation subassemblies compared the response of grouted sleeve connections with cast-in-place and pocket-foundation connections. Connection, debonding, grouted sleeve, pocket foundation, seismic retrofit. Review policy This paper was reviewed in accordance with the Precast/Prestressed Concrete Institute s peer-review process. Reader comments Please address any reader comments to journal@pci.org or Precast/Prestressed Concrete Institute, c/o PCI Journal, 2 W. Adams St., Suite 21, Chicago, IL 666. J PCI Journal Winter 212 19