Impression Material Technique Guide. Your source for implant impressions



Similar documents
Implant Bar Overdenture Utilizing Locator Attachments

Dental Implant Impressions: Steps to Easier and More Predictable Results

Restorative Manual Impression Transfer System

Nobel Clinician - Quick Guide

Multi-unit abutment bar overdenture

procedures & products NOBELESTHETICS including Procera

More than a fixed rehabilitation.

What Dental Implants Can Do For You!

Another Implant Option for Missing Teeth with Challenging Symmetry Patrick Gannon, DDS and Luke Kahng, CDT

prosthetic technique manual

Restorative Guidelines

Khaldoon G. Abu Afifeh, B.D.S, M. Sc in Prosthodontics

Solutions for Dentistry

PROSTHETIC PROCEDURE. for HG IMPLANT SYSTEM

stone model bonding tray improve the accuracy

RESTORING STRAUMANN IMPLANTS WITH LOCATOR ABUTMENTS

ATLANTIS abutments design guide CAD/CAM patient-specific abutments

One Abutment - One Time

BICON DENTAL IMPLANTS

IMPLANT DENTISTRY EXAM BANK

ball abutment overdenture: chairside pick-up using existing denture

Encode Restorative System Procedure & Laboratory Manual

Contents. Cement retained restoration. Screw retained restoration. Overdenture retained restoration. TS Implant System. 70 ComOcta Gold Abutment

SCD Case Study. Treatment Considerations for Implant Rehabilitation

Restoration of a screw retained single tooth restoration in the upper jaw with Thommen Titanium base abutment.

ATLANTIS ISUS the benchmark for CAD/CAM suprastructures. For all major implant systems

How To Use A Cresco

The Successful Crown Delivery

WIPE AND GO! No more time-consuming polishing of your provisionals. Structur 3. Structur 3

Product Catalog. ERA Mini TM Dental Implant System

Full Mouth Restoration with Screw-Retained Zirconia Bridges

Restoring quality to life. Dental implants. A naturally better solution. Patient Education

Prosthodontist s Perspective

Improving Esthetics with Sequential Treatment Planning and Implant-Retained Dentures

NARROW DIAMETER implant

Regular C/X Prosthetics. Prosthetics

Taking the Mystique out of Implant Dentistry. Dr. Michael Weinberg B.Sc., DDS, FICOI

screw-retained single crowns using custom-cast abutments

DESS. Screws. Tijuana Ventas: (664) /95 For all major implant systems!!

CHAPTER 10 RESTS AND PREPARATIONS. 4. Serve as a reference point for evaluating the fit of the framework to the teeth.


Many roads lead to a perfect impression...

Dental Implants - the tooth replacement solution

Implant solutions. 3M True Definition Scanner. Precise. implant impressions. with incredible speed

THE VOICE OF TECHNO-CLINICAL DENTISTRY

ATLANTIS abutments as individual as your patients

LOMAS / MONDEFIT ORTHODONTICS. The most innovative anchorage method for tooth correction

Like natural teeth. Treatment with dental implants is a safe, reliable and well-proven solution for permanently replacing one or more missing teeth.

Ideal treatment of the impaired

While the prosthetic rehabilitation of

DENT IMPLANT restoring qualit S: of LIfE

Removable Partial Dentures 101 Back to the Basics. Luther A. Ison, CDT University of Minnesota School of Dentistry

Digital impression solutions. 3M True Definition Scanner. Precise. impressions. in a jiffy

Procedures & Products Powered by Procera. All-on-4

STEP-BY-STEP INSTRUCTIONS ON THE PROSTHETIC PROCEDURES. Straumann Anatomic IPS e.max Abutment

Ridge Reconstruction for Implant Placement

Accurate Transfer of Peri-implant Soft Tissue Emergence Profile from the Provisional Crown to the Final Prosthesis Using an Emergence Profile Cast

Composite artistry- speedy mock up

In 1999, more than 1 million people in

The Transition from Teeth to Implants and the Use of Post-ceramic Soldering

Dental Updates. Excerpted Article Why Implant Screws Loosen Part 1. Richard Erickson, MS, DDS

Understanding Dental Implants

Abutment Solutions For customized implant restorations fabricated with CEREC and inlab. Digital all around.

BASIC INFORMATION ON THE STRAUMANN VARIOBASE ABUTMENT. Straumann Variobase Abutment

IMPLANT CONSENT FORM WHAT ARE DENTAL IMPLANTS?

Standard Internal Hex

DISCOVER THE NEW ANKYLOS GENERATION: ANKYLOS C/X with the option of indexing & more...

your talent. our technology. the perfect fit.

Discover the new ANKYLOS generation: ANKYLOS C/X with the option of indexing & more...

Replacement of the upper left central incisor with a Straumann Bone Level Implant and a Straumann Customized Ceramic Abutment

Ceramics on Implants Fixed Zirconium Dioxide-Based Restorations in the Rehabilitation of the Edentulous upper Jaw

Prosthetic Manual. Implant System. Contact Us: Smarter thinking. Simpler design. Phone: Fax:

The Simplus Denture System

Order of Treatment STEP-BY-STEP INSTRUCTIONS TO PLACE LOCATOR ATTACHMENTS

All-on-4 treatment concept with NobelSpeedy Groovy

Abutment fracture in a bridge supported by natural teeth and implants

Full Crown Module: Learner Level 3

Laboratory Designed Abutment. Optimization By Design

screw-retained crown using a PEEK temporary abutment

The Practice of Dental Technology and Clinical Dental Technology and the working relationship within the Practice of Dentistry Practice Standard

The LOCATOR concept. Simplicity and versatility for prosthesis fixation

PROSTHETICS. Crown and bridge restorations with the synocta prosthetic system.

Like natural teeth. Treatment procedure with dental implants SINGLE TOOTH REPLACEMENT

TRIOS Digital Impression Solution

DENTAL ADVANTAGE HELPFUL HINTS FOR THE RDA PRACTICAL EXAM

Straumann Dental Implant System. Implant Selection Guide.

Imprint 4 VPS Impression Material. Technical Data Sheet

Implants in your Laboratory: Abutment Design

Implant Assisted Removable Prosthodontics

Procedures & Products. NobelEsthetics

Tooth preparation J. C. Davenport, 1 R. M. Basker, 2 J. R. Heath, 3 J. P. Ralph, 4 P-O. Glantz, 5 and P. Hammond, 6

Guidance for implant removal. Straumann Dental Implant System

Molar Uprighting Dr. Margherita Santoro Division of Orthodontics School of Dental and Oral surgery. Consequences of tooth loss.

Simpl Implant Abutments with Atlantis CAD CAM Technology

Flexible dentures an alternate for rigid dentures? Volume 1 Issue 1

GIVE YOUR PATIENTS THE FREEDOM TO EAT, SPEAK AND LAUGH AGAIN.

Page 1 of 10 BDS FINAL PROFESSIONAL EXAMINATION 2007 Prosthodontics (MCQs) Model Paper SECTION I

Rebilda DC. Rebilda Post System. Rebilda

How to Achieve Shade Harmony With Different Restorations

Press Abutment Solutions

Transcription:

Impression Material Technique Guide Your source for implant s

An accurate for a precise-fitting implant. With a rapidly aging population, dental implants are fast becoming a preferred restoration for permanent tooth replacement. If you re among the growing number of doctors who are incorporating implants into their practice, here s good news. 3M ESPE, the worldwide leader in solutions, has developed products and simplified procedures to help you achieve outstanding functional and esthetic results. Your initial is critical because: In order for you to achieve accurate fabrication of an implant-retained prosthesis, the must record an exact registration of the relative position and orientation of the implant to other implants, teeth and soft tissue. A technician uses it to create a highly precise stone model or digital that becomes the basis for your entire implant treatment plan. 3M ESPE materials provide excellent detail for accurate implant s. The implant treatment plan can only be as accurate as your. The performance and detail reproduction of 3M ESPE materials help you: Impregum Penta Soft Polyether Impression Materials Achieve a detailed on the first take. Whether using an open or closed tray technique, or making implant- or abutment-level s, a detailed reduces the chance of costly retakes. Capture s of transfer copings with confidence. Ensure the precise orientation and position of the implant in the mouth. The choice is yours. Whether you prefer polyether or VPS material, 3M ESPE, the worldwide leader in materials, has you covered. Summary of advantages Intrinsic hydrophilicity best detail reproduction in a moist environment Excellent flow properties enables intimate contact with transfer coping Rigidity secures implant coping position

Achieve excellent results using any implant system you choose. A number of implant companies offer excellent implant options to choose from. No matter what system you prefer, using a 3M ESPE material can help you achieve your desired outcome, using the technique you determine is best for the indication. Impression Technique and Material Recommendations There are numerous techniques for making implant s. 3M ESPE has highlighted three common techniques, along with material recommendations for each, to assist clinicians in making this critical decision. Technique: Material: Closed Tray Indirect Transfer Impression Technique Imprint 3 VPS Impression Materials Technique: Material: Open Tray Direct Pick-Up Impression Technique Impregum Penta Soft Polyether Impression Materials Technique: Material: Closed Tray Direct Snap-On Impression Technique Imprint 3 VPS Impression Materials, OR Impregum Penta Soft Polyether Impression Materials Impression Tray Recommendations For cases with 1 or 2 implant units: Use a 3M ESPE Directed Flow Impression Tray. Imprint 3 VPS Impression Material Transparent, and easy to customize you can cut windows for Open Tray indications Distal flow stops help ensure you capture detail on the 2nd molars For multiple implants or for edentulous entulous situations: Use a rigid custom tray. Prepare the tray with the appropriate tray adhesive to ensure reliable adhesion of the material Self-adhesive no tray adhesive is required The spoiler on the upper arch tray traps excess material to reduce gagging while it deflects material toward lingual tooth surfaces Summary of advantages Memory best in class elastic recovery resists distortion for a more accurate transfer Toughness s resists tearing upon removal from mouth Best balance of clinical properties no sacrifice of one property for another means better final s

Closed Tray Indirect Transfer Impression Technique In this technique, the indirect transfer coping remains on the implant during removal of the set from the mouth. Once the has been removed, the coping is removed from the implant and connected with the implant analog. The coping/analog assembly is then indexed (transferred) back into its corresponding position in the. Recommended material: Imprint 3 VPS Impression Material Implant Impression Tips Common causes for retakes: Distorted : To prevent distortion, stabilize the tray while material is setting Voids and bubbles: Use enough material and keep tip submerged in extruded material Insufficient capture of detail around coping: Syringe material without creating air bubbles around copings by keeping mix tip submerged 1 Removal of healing abutment 2 Placement of transfer coping 3 Remove healing abutment Confirm prosthetic platform is free of bone debris or soft tissue Seat the coping and secure it using the method recommended by the implant manufacturer Verify correct seating of the coping with a radiograph Block out hex-hole with material of choice Tray selection closed tray try-in Try-in the tray Ensure there is appropriate clearance for entire arch Evaluate tray-coping fit, ensuring there is no impingement/ interference OR 4 Load tray 5 Syringe around coping 6 Tray seating and immobilization Load the tray material after using proper bleeding technique Keep the mix tip submerged in the tray material to prevent voids Do not under-fill the tray While loading the tray, syringe the wash material around the coping, and ensure continuous flow around the entire coping Keep the mix tip submerged in the wash material at all times to avoid trapping air bubbles Insert the loaded tray straight and evenly into mouth avoid rotation Don t let patient bite down on tray Immobilize the tray using passive pressure Follow the recommended setting time in the mouth using a timer 7 Tray and coping removal 8 Evaluate final with coping inserted (indexed) 9 Bite registration Remove tray from mouth carefully after end of setting time Remove coping assembly from implant after tray has been removed, following implant manufacturer s instructions Replace healing abutment immediately to prevent soft tissue collapse Assemble coping with implant analog Rinse before inspection Evaluate the for correct transfer and common errors (see side bar on this page) Insert coping assembly into Ensure the coping is properly aligned (indexed) within the Dry and disinfect before shipping Apply a layer of 3M ESPE Imprint Bite Material with a thickness of approximately 5mm occlusal-incisally to the entire lower arch Have patient bite into proper occlusion Disinfect prior to shipping Make an of the opposing arch and submit it with case

Open Tray Direct Pick-Up Impression Technique In this technique, the direct transfer coping gets picked up, and remains in the set upon removal from the mouth. Once the has set, the screw holding the coping on the implant is accessed through the hole above/below the implant in the open tray and unscrewed to allow removal of the from the mouth. Once outside of the mouth, the implant analog is connected to the transfer coping prior to pouring the stone model. Recommended material: Impregum Penta Soft Polyether Impression Material Implant Impression Tips Common causes for retakes: Distorted : To prevent, stabilize tray as material is setting Voids and bubbles: Use enough material and keep tip submerged in extruded material (Pick-up technique) Tray-abutment contact: Widen implant windows in tray 1 Removal of healing abutment Remove healing abutment Confirm prosthetic platform is free of bone debris or soft tissue Seat the coping and secure it using the method recommended by the implant manufacturer 2 Placement of transfer coping Verify correct seating of the coping with a radiograph 3 Tray selection open tray try-in Try-in the tray and create access window Ensure there is appropriate clearance for entire arch with no contact between tray and tissue Evaluate tray-coping fit, ensuring there is enough clearance for coping to fit easily through window in tray OR 4 Load tray 5 Syringe around coping 6 Tray seating and immobilization Load the tray material after using proper bleeding technique Keep the mix tip submerged in the tray material to prevent voids Do not under-fill the tray While loading the tray, syringe the wash material around the coping, and ensure continuous flow around the entire coping Keep the mix tip submerged in the wash material at all times to avoid trapping air bubbles Insert the loaded tray straight and evenly into mouth avoid rotation Don t let patient bite down on tray Immobilize the tray using passive pressure Follow the recommended setting time in the mouth using a timer 7 Tray and coping removal 8 Evaluate final with coping inserted (indexed) 9 Bite registration Once material has set, remove screw holding coping in place, following implant manufacturer s instructions Remove tray from mouth carefully, with coping embedded in the set Replace healing abutment immediately to prevent soft tissue collapse Rinse before inspection Evaluate the for correct transfer and common errors (see side bar on this page) Attach the implant analog to coping embedded in the Dry and disinfect before shipping Apply a layer of 3M ESPE Imprint Bite Material with a thickness of approximately 5mm occlusal-incisally to the entire lower arch Have patient bite into proper occlusion Disinfect prior to shipping Make an of the opposing arch and submit it with case

Closed Tray Direct Snap-On Impression Technique The snap-on procedure is best described as a hybrid between the two techniques shown previously. In this closed tray procedure, the direct transfer coping snaps-on to the top of the implant abutment in the mouth. Once the has set, the coping becomes embedded in the and is pulled off of the implant abutment when the set is removed from the mouth. Once outside of the mouth, the implant analog is connected to the transfer coping prior to pouring the stone model. Recommended material: Imprint 3 VPS Impression Material Or Impregum Penta Soft Polyether Impression Material Implant Impression Tips Common causes for retakes: Distorted : To prevent, stabilize the tray while material is setting Voids and bubbles: Use enough material and keep tip submerged in extruded material (Snap-on technique) Coping-tray contact: Try-in the tray prior to making s and ensure proper size 1 Removal of healing abutment Remove healing abutment Confirm prosthetic platform is free of bone debris or soft tissue 2 Placement of transfer coping Seat the abutment and secure it using the method recommended by the implant manufacturer Attach the snap-on transfer coping assembly (see completed assembly in step 5) 3 Tray selection closed tray try-in Try-in the tray Ensure there is appropriate clearance for entire arch Evaluate tray-coping fit, ensuring there is no impingement/ interference OR 4 Load tray Load the tray material after using proper bleeding technique Keep the mix tip submerged in the tray material to prevent voids Do not under-fill the tray 5 Syringe around coping While loading tray, syringe the wash material around the coping, and ensure continuous flow around the entire coping Keep the mix tip submerged in the wash material at all times to avoid trapping air bubbles 6 Tray seating and immobilization Insert the loaded tray straight and evenly into mouth avoid rotation Don t let patient bite down on tray Immobilize the tray using passive pressure Follow the recommended setting time in the mouth using a timer 7 Tray and coping removal 8 Evaluate final with coping inserted (indexed) 9 Bite registration Once material has set, remove tray from mouth carefully, with snap-on coping embedded in the set Depending on the implant system used, either A) Replace healing abutment immediately to prevent soft tissue collapse, OR B) Create the appropriate temporary restoration to protect the abutment Assemble coping with implant analog Rinse before inspection Evaluate the for correct transfer and common errors (see side bar on this page) Dry and disinfect before shipping Apply a layer of 3M ESPE Imprint Bite Material with a thickness of approximately 5mm occlusal-incisally to the entire lower arch Have patient bite into proper occlusion Disinfect prior to shipping Make an of the opposing arch and submit it with case

Ordering Information Impregum Penta Soft Polyether Impression Material P31739 Impregum Penta Soft Heavy Body/Light Body Introductory Kit Kit Includes: 1 base paste HB 300ml; 1 catalyst HB 60ml; 1 Penta cartridge HB; 10 Penta mixing tips, red; 2 cartridges LB 50ml; 10 cartridge mixing tips, white; 10 intraoral tips, white; 1 cartridge dispenser; 1 polyether tray adhesive 17ml P31779 Impregum Penta Soft Quick Step Heavy Body/Light Body Introductory Kit Kit Includes: 1 base paste HB 300ml; 1 catalyst HB 60ml; 1 Penta cartridge HB; 10 Penta mixing tips, red; 10 cartridge mixing tips, white; 10 intraoral tips, white; 1 polyether tray adhesive 17ml; 2 cartridges LB 50ml P31735 Impregum Penta Soft Medium Body Introductory Kit Kit Includes: 1 base paste MB 300ml; 1 catalyst MB 60ml; 1 Penta cartridge MB; 10 Penta mixing tips, red; 1 Penta elastomer syringe; 1 polyether tray adhesive 17ml P31771 Impregum Penta Soft Quick Step Medium Body Introductory Kit Kit Includes: 1 base paste MB 300ml; 1 catalyst MB 60ml; 1 Penta cartridge MB; 10 Penta mixing tips, red; 1 Penta elastomer syringe; 1 polyether tray adhesive 17ml P31685 Impregum Penta Medium Body Introductory Kit Kit Includes: 1 base paste MB 300ml; 1 catalyst MB 60ml; 1 Penta cartridge MB; 10 Penta mixing tips, red; 1 elastomer syringe; 1 polyether tray adhesive 17ml 31741 Impregum Penta Soft Heavy Body Refill Pack Item # Product Information 31769 Impregum Penta Soft Quick Step Heavy Body Refill Pack 31731 Impregum Penta Soft Medium Body Refill Pack 31765 Impregum Penta Soft Quick Step Medium Body Refill Pack 31642 Impregum Penta Medium Body Refill Pack 31746 Impregum Penta Soft Light Body Refill Pack 31767 Impregum Penta Soft Quick Step Light Body Refill Pack 4 cartridges 50ml; 20 cartridge mixing tips, white 31752 Impregum Soft Light Body Refill Pack 4 cartridges 50ml; 20 cartridge mixing tips, white 30500 Polyether Retarder Refill Pack 1 8ml tube (Prolongs working time up to 1 minute) 71512 50 Penta Mixing Tips, Red 71451 50 Cartridge Polyether Mixing Tips, White 71461 50 Cartridge Polyether Intraoral Tips, White Imprint 3 VPS Impression Material 10770 Imprint 3 Heavy Body/Light Body Intro Kit Kit includes: 2 cartridges HB 50ml; 1 cartridge RB 50ml; 1 cartridge LB 50ml; 10 cartridge mixing tips, green; 10 cartridge mixing tips, yellow; 10 intraoral tips, yellow; 1 VPS adhesive 17ml P310770 Imprint 3 Penta Heavy Body/Light Body Intro Kit Kit includes: 1 base paste HB 300ml; 1 catalyst paste HB 60ml; 1 Penta cartridge HB; 10 Penta mixing tips, red; 1 cartridge RB 50ml; 1 cartridge LB 50ml; 10 cartridge mixing tips, green; 10 cartridge mixing tips, yellow; 10 intraoral tips, yellow; 1 VPS adhesive 17ml 10970 Imprint 3 Quick Step Heavy Body/Light Body Intro Kit Kit includes: 2 cartridges HB 50ml; 1 cartridge RB 50ml; 1 cartridge LB 50ml; 10 cartridge mixing tips, green; 10 cartridge mixing tips, yellow; 10 intraoral tips, yellow; 1 VPS adhesive 17ml P310790 Imprint 3 Penta Quick Step Heavy Body/Light Body Intro Kit Kit includes: 1 base paste HB 300ml; 1 catalyst paste HB 60ml; 1 Penta cartridge HB; 10 Penta mixing tips, red; 1 cartridge RB 50ml; 1 cartridge LB 50ml; 10 cartridge mixing tips, green; 10 cartridge mixing tips, yellow; 10 intraoral tips, yellow; 1 VPS adhesive 17ml 10771 Imprint 3 Heavy Body Refill 4 cartridges HB 50ml; 10 mixing tips, green 10971 Imprint 3 Quick Step Heavy Body Refill 4 cartridges HB 50ml; 10 mixing tips, green 10771PH 10971PH Imprint 3 Penta Heavy Body Refill Imprint 3 Penta Quick Step Heavy Body Refill Directed Flow Impression Tray Refill Pack Upper 71615 10 Trays, Size Small (S), Upper 71616 10 Trays, Size Medium (M), Upper 71617 10 Trays, Size Large (L), Upper 10781 Imprint 3 Monophase (Medium Body) Refill 4 cartridges MB 50ml; 10 cartridge mixing tips, green 36956 Imprint 3 Ultra-Regular Body Wash Refill 4 cartridges URB 50ml; 20 mixing tips, yellow 36955 Imprint 3 Quick Step Ultra-Regular Body Wash Refill 4 cartridges URB 50ml; 20 mixing tips, yellow 10779 Imprint 3 Regular Body Wash Refill 4 cartridges RB 50ml; 20 mixing tips, yellow 10979 Imprint 3 Quick Step Regular Body Wash Refill 4 cartridges RB 50ml; 20 mixing tips, yellow 10778 Imprint 3 Light Body Wash Refill 4 cartridges LB 50ml; 20 mixing tips, yellow 10978 Imprint 3 Quick Step Light Body Wash Refill 4 cartridges LB 50ml; 20 mixing tips, yellow 36850 Imprint Bite Registration Material Refill 4 cartridges 50ml; 20 cartridge mixing tips, green 71512 50 Penta Mixing Tips, Red 71450 50 Cartridge Mixing Tips, Green 71452 50 Cartridge Mixing Tips, Yellow 71460 50 Cartridge Intraoral Tips, Bite 71462 50 Cartridge Intraoral Tips, Yellow Refill Pack Lower 71618 10 Trays, Size Small (S), Lower 71619 10 Trays, Size Medium (M), Lower 71620 10 Trays, Size Large (L), Lower

Products designed for the way you like to work For every implant indication, you ll find a 3M ESPE polyether or VPS material to suit your technique and procedure. Choose from a wide range of viscosities and set/working times in both cartridge and Penta deliveries. More proven solutions brought to you by 3M ESPE, the worldwide leader in materials. Impregum Penta Soft Polyether Impression Material Be confident you ll get accurate detail even in moist conditions. Summary of advantages Initially hydrophilic to provide void-free s in moist conditions Excellent flow property captures fine details that lead to precise-fitting restorations Snap-set behavior of Soft polyether is ultra-forgiving Excellent rigidity secures implant coping position Quick Step material cuts working and setting times by at least 33% over Impregum Penta Soft Polyether Impression Material Imprint 3 VPS Impression Material Make s that resist distortion for precise-fitting restorations. Summary of advantages Best balance of clinical properties, compared to other leading brands Better memory than leading VPS brands with nearly 100% recovery from elongation, it s less likely to distort upon removal from the mouth More hydrophilic than most leading VPS materials, helping you capture accurate detail in a moist environment Tougher than many leading brands, which helps s hold true and resist tearing during removal Make Better Impressions Even the most experienced practitioner, using the best materials, can encounter difficulties when making an. 3M ESPE has taken its long history in developing and testing materials, and assembled the Making Better Impressions Troubleshooting Guide. It identifies common problems and offers solutions. To get your FREE copy, download it now from our website or call Customer Care at 1-800-634-2249, ext. 1. Customer Care Center: 1-800-634-2249 www.3mespe.com Dental Products 3M Canada 3M Center Building 275-2SE-03 St. Paul, MN 55144-1000 U.S.A. 1-800-634-2249 Post Office Box 5757 London, Ontario N6A 4T1 Canada 1-888-363-3685 Please recycle. Printed in U.S.A. 3M 2008. All rights reserved. 70-2009-3887-9 3M, ESPE, Espertise, Imprint, Impregum and Penta are trademarks of 3M or 3M ESPE AG. Used under license in Canada.