DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: METAL ROOF PANELS REPORT HOLDER: CUSTOM-BILT METALS



Similar documents
DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: METAL ROOF PANELS REPORT HOLDER: FIRESTONE BUILDING PRODUCTS COMPANY, LLC

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: CONCRETE ROOF TILES REPORT HOLDER:

ICC-ES Evaluation Report Reissued March 1, 2011 This report is subject to renewal in one year.

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: CONCRETE ROOF TILES REPORT HOLDER: BORAL ROOFING

(800) (562) A Subsidiary of the International Code Council *Revised April 2014

DIVISION: SPECIALTIES SECTION: PROTECTIVE COVERS REPORT HOLDER: METALS BUILDING PRODUCTS/LATIUM USA TRADING, INC.

DIVISION: WOOD, PLASTICS AND COMPOSITES SECTION: WOOD, PLASTIC, AND COMPOSITE FASTENINGS REPORT HOLDER:

REPORT HOLDER: JENWEST ENTERPRISES LLC, DBA ADVANCED CONNECTOR SYSTEMS 321 SOUTH 1240 WEST #15 LINDON, UTAH EVALUATION SUBJECT:

Trusted SECTION: 04 HILTI, INC. TULSA, Conformity! ICC-ES Evaluation. not specifically. Copyright 2015

GUIDE SPECIFICATION. Manufacturer: DECRA Roofing Systems, Inc.

DIVISION: WOOD, PLASTICS AND COMPOSITES SECTION: SHOP APPLIED WOOD COATINGS SECTION: SHEATHING REPORT HOLDER:

ROOF ASSEMBLIES AND ROOFTOP STRUCTURES

RB271 06/07 R807.1 RB272 06/07 R Public Hearing: Committee: AS AM D Assembly: ASF AMF DF. Proponent: Rick Davidson, City of Hopkins, MN

Final inspections are completed by site visit only. Access to fenced yards shall be planned.

Drexel Metals Inc. DMC 100SS 16oz min. Copper Mechanical Seam Metal Roof System over Plywood

DIVISION: MASONRY SECTION: MASONRY ANCHORS REPORT HOLDER: HILTI, INC DALLAS PARKWAY, SUITE 1000 PLANO, TEXAS 75024

ROOF ASSEMBLIES AND ROOFTOP STRUCTURES

ICC-ES Evaluation Report

STANDARD PROCEDURES FOR INSTALLATION OF METAL ROOF SYSTEMS

Metal Roofing Practical Design

GUIDE SPECIFICATION. Manufacturer: DECRA Roofing Systems, Inc.

Residential Roofing Guide

Discipline: Structural Issued

MIAMI-DADE COUNTY PRODUCT CONTROL SECTION DEPARTMENT OF REGULATORY AND ECONOMIC RESOURCES (RER)

TABLE OF CONTENTS" SECTION 3: Comparing Standing Seam Metal to Other Metal Roofs PAGE 7"

LEGACY REPORT. (800) (562) A Subsidiary of the International Code Council RETAINED ON U.S.

HCD DSA OSHPD 1 2 1/AC AC SS

Detached accessory structures that contain no conditioned floor area are exempt.

ROOF ASSEMBLIES AND ROOFTOP STRUCTURES

Table of Contents. Western States Standing Seam SS675 Panel Installation, Flashings & Shop Drawing Detail Guide. Notes to Designer /Installers..

CHAPTER 7: Building Systems ROOFING SYSTEMS

ICC-ES Evaluation Report Reissued September, 2010 This report is subject to re-examination in one year.

SECTION STANDING SEAM METAL ROOF

ROOF ASSEMBLIES AND ROOFTOP STRUCTURES

RESIDENTIAL ROOFING & RE-ROOFING, ROOF VENTILATION AND ROOF SHEATHING REQUIREMENTS MICHIGAN RESIDENTIAL CODE 2000

Asphalt Shingle Application Requirements

Holiday Inn Express & Suites Covington (Newton County) 1. Standing-seam metal roofing, custom fabricated.

VAIL Metal Shingles. Application Instructions. Custom-Bilt Metals Magnolia Ave. Chino, CA 91710

DENVER MODEL 30 X 30 SPECIFICATIONS

Discount Direct Metal Roofing Plus Rib Roofing Panels Installation Instructions

CB-100 CB-150 CS-100 SL-100 SL-150 SLZ-1000

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: THERMAL INSULATION REPORT HOLDER: ICYNENE, INC.

Standing Seam Roof Systems

ROOF ASSEMBLIES CHAPTER 9

THE DOW CHEMICAL COMPANY Issued: August 1, LARKIN CENTER 1605 JOSEPH DRIVE MIDLAND MICHIGAN (989)

DIVISION: PLUMBING SECTION: DOMESTIC WATER PIPING REPORT HOLDER: CURAFLO IP LLC 4035 E. OASIS STREET MESA, AZ 85215

ROOFING APPLICATION STANDARD (RAS) No. 150 PRESCRIPTIVE BUR REQUIREMENTS

ROOF ASSEMBLIES AND ROOFTOP STRUCTURES

LEGACY REPORT ER ICC Evaluation Service, Inc. Reissued November 1, Legacy report on the 1997 Uniform Building Code

780 CMR ROOF ASSEMBLIES AND ROOFTOP STRUCTURES

NRCA s steep-slope manual is thoroughly revised for 2013

238T Standing Seam Metal Roof System (SSMRS)

APPLICATION INFORMATION FOR RESIDENTIAL ROOFING AND RESIDENTIAL ROOFING PACKET

INSTALLATION MANUAL For Grand Rib-3 / Multi Purpose / & Classic Rib Roofing Panels

SECTION PREFORMED METAL STANDING SEAM ROOFING PART 1 - GENERAL 1.1 DESCRIPTION OF WORK

COLORADO MODEL. 35 x 65 SPECIFICATIONS

SECTION STANDING SEAM METAL ROOFING

PRODUCT SPECIFICATIONS

ICC-ES Evaluation Report. ESR-3493 Reissued September 2014 This report is subject to renewal September 2015.

GYPSUM BOARD, GYPSUM PANEL PRODUCTS AND PLASTER

SECTION PREFORMED METAL STANDING SEAM ROOFING

Residential Metal Roofing

Table of Contents. Western States RustWall Wall and Soffit Panels Installation, Flashings & Shop Drawing Detail Guide

ROOF ASSEMBLIES AND ROOFTOP STRUCTURES

SINGLE FAMILY RESIDENCE HURRICANE MITIGATION APPLICATION

Chapter 3 Pre-Installation, Foundations and Piers

Materials and Colors

metal Duil~ing manufacturers Association

ESR-1190 Reissued December 1, 2009 This report is subject to re-examination in two years.

Section Page Section Page

What makes DECRA Roofing Systems unique?

Installation Manual for STANDING SEAM ROOFING

Rouse Life Sciences Roof Repair or Replacement SECTION

Metal Roof Systems in High-Wind Regions

Installation Guide MATTERHORN METAL ROOFING TO LAST A LIFETIME. MATTERHORN Standing Seam

Screw Patterns Roof & Walls TR-36 MD-36 TSM-32. PBR-Panel

Solar Water Heating and Solar Electric Generators Installed on One or Two Family Dwellings

Larry Haight's Residential Roofing Co, Inc NE 95th Street Redmond, Washington Phone: (425) Fax: (425)

Classic Products, Inc. ClickLock Standing Seam Installation Manual

Fire-Retardant-Treated (FRT) Plywood

How To Compare Roofing Material

AIA PRESENTATION. Standing Seam Metal Roofing Seminar SSRLU2B 1 LU/HSW Hour

How To Build A Roof Tile Deck

ATI Evaluation Service A Division of Architectural Testing Certification Services

Patio Covers / Carports

STANDARD OPEN PATIO COVER

GUIDELINES FOR PLAN CHECK AND PERMIT REQUIREMENTS FOR SOLAR ENERGY SYSTEMS

Standard from CSI Part Section Format For Wood Framing For Metal Framing For Gypsum Sheathing

POST AND FRAME STRUCTURES (Pole Barns)

Nucor VR16 II TM Vertical Rib Standing Seam Roof System

TARRANT COUNTY DETAIL STANDARDS

The SunMizer SRS Advantage. Copyright 2013 Xandex Inc.

HURRICANE MITIGATION RETROFITS FOR EXISTING SITE-BUILT SINGLE FAMILY RESIDENTIAL STRUCTURES

MANUFACTURED HOUSING USED AS DWELLINGS

Load Design Charts. R-CONTROL SIPs STRUCTURAL INSULATED PANELS. CONTROL, NOT COMPROMISE.

GYPSUM BOARD AND PLASTER

The Butler MR-24 Standing Seam Roof Difference. A comparison between metal roof systems

SECTION METAL ROOF & WALL PANELS

LEGACY REPORT. (800) (562) A Subsidiary of the International Code Council. *Corrected March 2014

Slim Seam Architectural Design Manual

Transcription:

0 ICC-ES Report ICC-ES (800) 423-6587 (562) 699-0543 www.icc-es.org 000 Most Widely Accepted and Trusted ESR-2048 Reissued 03/2015 This report is subject to renewal 03/2017 DIVISION: 07 00 00 THERMAL AND MOISTURE PROTECTION SECTION: 07 41 13 METAL ROOF PANELS CUSTOM-BILT STANDING SEAM METAL ROOF PANELS: CB-150 AND SL-1750 Look for the trusted marks of Conformity! 2014 Recipient of Prestigious Western States Seismic Policy Council (WSSPC) Award in Excellence A Subsidiary of ICC-ES Evaluation Reports are not to be construed as representing aesthetics or any other attributes not specifically addressed, nor are they to be construed as an endorsement of the subject of the report or a recommendation for its use. There is no warranty by ICC Evaluation Service, LLC, express or implied, as Copyright 2015

ICC-ES Evaluation Report www.icc-es.org (800) 423-6587 (562) 699-0543 ESR-2048 Reissued March 2015 This report is subject to renewal March 2017. A Subsidiary of the International Code Council DIVISION: 07 00 00 THERMAL AND MOISTURE PROTECTION Section: 07 41 13 Metal Roof Panels (888) 875-8484 www.custombiltmetals.com CUSTOM-BILT STANDING SEAM METAL ROOF PANELS: CB-150 AND SL-1750 1.0 EVALUATION SCOPE Compliance with the following codes: 2012 and 2009 International Building Code (IBC) 2012 and 2009 International Residential Code (IRC) 2013 Abu Dhabi International Building Code (ADIBC) The ADIBC is based on the 2009 IBC. 2009 IBC code sections referenced in this report are the same sections in the ADIBC. Properties evaluated: Weather resistance Fire classification Wind uplift resistance 2.0 USES Custom-Bilt Standing Seam Metal Roof Panels are steel panels complying with IBC Section 1507.4 and IRC Section R905.10. The panels are recognized for use as Class A roof coverings when installed in accordance with this report. 3.0 DESCRIPTION 3.1 Roofing Panels: Custom-Bilt standing seam roof panels are fabricated in steel and are available in the CB-150 and SL-1750 profiles. The panels are roll-formed at the jobsite to provide the standing seams between panels. See Figures 1 and 3 for panel profiles. The standing seam roof panels are roll-formed from minimum No. 24 gage [0.024 inch thick (0.61 mm)] coldformed sheet steel. The steel conforms to ASTM A792, with an aluminum-zinc alloy coating designation of AZ50. The panel profiles are as follows: CB-150: This profile is formed to 12- or 16-inch-wide (305 or 406 mm) panels, with 1 1 / 2 -inch-high (38 mm) mechanically locking seams. See Figure 1. SL-1750: This profile is formed to 14- or 18-inch-wide (356 or 457 mm) panels, with 1 3 / 4 -inch-high (44 mm) snap-locking seams. See Figure 3. 3.2 Decking: Solid or closely fitted decking must be minimum 15 / 32 -inchthick (11.9 mm) wood structural panel or lumber sheathing, complying with IBC Section 2304.7.2 or IRC Section R803, as applicable. 3.3 Underlayment and Flashing: Underlayment, when used, must comply with ASTM D226 or GAF VersaShield Fire-Resistant Roof Deck Protection (ESR-2053). Flashing must be in accordance with the applicable code. 3.4 Panel Clips: Panel clips are supplied by Custom-Bilt, and are fabricated from ASTM A653 sheet steel with a zinc coating designation of G90, and a base-metal thickness of 0.024 inch [0.61 mm (No. 24 gage)] for the CB-150 and 0.048 inch [1.22 mm (No. 18 gage)] for the SL-1750. See Figures 2 and 4 for panel clips and dimensions. 3.5 Fasteners: Fasteners for attaching the anchor clips to the sheathing must be corrosion-resistant screws of sufficient length to penetrate into the sheathing a minimum of 3 / 4 inch (19 mm) or through the thickness of the sheathing, whichever is less. 4.0 DESIGN AND INSTALLATION 4.1 General: Installation of the Custom-Bilt Standing Seam Roof Panels must be in accordance with this report, Section 1507.4 of the IBC or Section R905.10 of the IRC, and the manufacturer s published installation instructions. The manufacturer s installation instructions must be available at the jobsite at all times during installation. The roof panels must be installed on solid or closely fitted decking, as specified in Section 3.2. Accessories such as gutters, drip angles, fascias, ridge caps, window or gable trim, valley and hip flashings, etc., are fabricated to suit each job condition. Details must be submitted to the code official for each installation. ICC-ES Evaluation Reports are not to be construed as representing aesthetics or any other attributes not specifically addressed, nor are they to be construed as an endorsement of the subject of the report or a recommendation for its use. There is no warranty by ICC Evaluation Service, LLC, express or implied, as Copyright 2015 Page 1 of 3 1000

ESR-2048 Most Widely Accepted and Trusted Page 2 of 3 4.2 Roof Panel Installation: 4.2.1 CB-150: The CB-150 roof panels are installed on roofs having a minimum slope of 2:12 (17 percent). The roof panels are installed over underlayment, when required by the applicable codes, and secured to the sheathing with the panel clip shown in Figure 2. The clips are located at each panel rib side lap spaced 6 inches (152 mm) from all ends and at a maximum of 4 feet (1.22 m) on center along the length of the rib, and fastened with a minimum of two No. 10 by 1-inch pan head corrosion-resistant screws. The panel ribs are mechanically seamed twice, each pass at 90 degrees, resulting in a double-locking fold as shown in Figure 1. 4.2.2 SL-1750: The SL-1750 roof panels are installed on roofs having a minimum slope of 3:12 (25 percent). The roof panels are installed over underlayment, when required by the applicable codes, and secured to the sheathing with the panel clips shown in Figure 4. The clips are located at each panel rib side lap spaced 6 inches (152 mm) from all ends and at a maximum of 3 feet (914 mm) on center along the length of the rib, and fastened with a minimum of two No. 10 by 1-inch pan head corrosion-resistant screws. After installation of fasteners along one side, each panel is lapped over the preceding panel and snap-locked into place. 4.3 Fire Classification: The roof covering system described in Table 1, when installed in accordance with this report, is a Class A roof covering in accordance with ASTM E108 (UL 790). 4.4 Wind Uplift Resistance: The systems described in Section 3.0 and installed in accordance with Sections 4.1 and 4.2 have an allowable wind uplift resistance of 45 pounds per square foot (2.15 kpa). 5.0 CONDITIONS OF USE The standing seam metal roof panels described in this report comply with, or are suitable alternatives to what is specified in, those codes listed in Section 1.0 of this report, subject to the following conditions: 5.1 The panels are manufactured, identified and installed in accordance with this report, the applicable code, and the manufacturer s published installation instructions. In the event of a conflict between this report and the manufacturer s published installation instructions, this report governs. 5.2 The required design wind loads must be determined for each project. Wind uplift pressure on any roof area must not exceed 45 pounds per square foot (2.15 kpa). 5.3 The Custom-Bilt Standing Seam Roof Panels are manufactured in Chino, California, and McClellan, California, under a quality control program with inspections by ICC-ES. 6.0 EVIDENCE SUBMITTED Data in accordance with the ICC-ES Acceptance Criteria for Metal Roof Coverings (AC166), dated October 2012. 7.0 IDENTIFICATION Each standing seam metal roof panel is identified with a label bearing the product name, the material type and gage, the Custom-Bilt Metals name and address, and the evaluation report number (ESR-2048). SYSTEM 1 See Section 3.2. MAXIMUM SLOPE (inch/foot) 1 Unlimited TABLE 1 ROOF CLASSIFICATION DECK 1 UNDERLAYMENT METAL PANEL ROOF CLASS Minimum 15 / 32 " Plywood One Layer of Type II (No. 30) Underlayment and Two Layers of GAF VersaShield Fire- Resistant Roof Deck Protection CB-150 or SL-1750 A

ESR-2048 Most Widely Accepted and Trusted Page 3 of 3

ICC-ES Evaluation Report ESR-2048 CBC and CRC Supplement Issued March 2015 This report is subject to renewal March 2017. www.icc-es.org (800) 423-6587 (562) 699-0543 A Subsidiary of the International Code Council DIVISION: 07 00 00 THERMAL AND MOISTURE Section: 07 41 13 Metal Roof Panels (888) 875-8484 www.custombiltmetals.com CUSTOM-BILT STANDING SEAM METAL ROOF PANELS: CB-150 AND SL-1750 1.0 REPORT PURPOSE AND SCOPE Purpose: The purpose of this evaluation report supplement is to indicate that Custom-Bilt Standing Seam Metal Roof Panels, recognized in ICC-ES master report ESR-2048, have also been evaluated for compliance with the codes noted below. Applicable code editions: 2010 California Building Code (CBC) 2010 California Residential Code (CRC) 2.0 CONCLUSIONS 2.1 CBC: The Custom-Bilt Standing Seam Metal Roof Panels described in the master report ESR-2048 may be used where a Class A roof covering complying with CBC Section 1505.1.1, a Class B roof covering complying with CBC Section 1505.1.2, or a Class C roof covering complying with CBC Section 1505.1.3 is required, provided installation is in accordance with the master report. The roofing panels may be used in the construction of new buildings located in a Fire Hazard Zone within a State Responsibility Area or any Wildland-Urban Interface Fire Area, provided installation is in accordance with the master report and the additional requirements of Sections 701A.3 and 705A of the CBC. 2.2 CRC: The Custom-Bilt Standing Seam Metal Roof Panels described in the master report ESR-2048 may be used where a Class A roof cover complying with CRC Section R902.1.1, a Class B roof covering complying with CRC Section R902.1.2, or a Class C roof covering complying with CRC Section R902.1.3 is required, provided installation is in accordance with the master report and the additional requirements of Section R905.4 of the CRC. The roofing panels may be used in the construction of new buildings located in any Wildland Urban Interface Fire Area, provided installation is in accordance with the master report and the additional requirements of Sections R327.1.3.1 and R327.5 of the CRC. The products recognized in this supplement have not been evaluated for compliance with the International Wildland Urban Interface Code. This supplement expires concurrently with the master report reissued March 2015. ICC-ES Evaluation Reports are not to be construed as representing aesthetics or any other attributes not specifically addressed, nor are they to be construed as an endorsement of the subject of the report or a recommendation for its use. There is no warranty by ICC Evaluation Service, LLC, express or implied, as Copyright 2015 Page 1 of 1 1000