The Systems Approach to Lift Station Design, Operation, Installation and Maintenance



Similar documents
Godwin NC series Dri-Prime pumps

Design of Sewage Pumping Stations by John Zoeller, PE, CEO/President

Terry Biederman, PE- Director of Public Works Greg Gucwa, PE- Principal Johnson and Anderson Engineering

Pure Performance. Steady 1300 Series

APPENDIX M-2 SANITARY SEWER TECHNICAL MEMORANDUM. Stadium Reconstruction EIR

Master Planning and Hydraulic Modeling

BOWL ASSEMBLY SELECTION Select impeller in exactly the same manner as for lineshaft type pump. Note comments under WELL SIZE.

Emerging Technologies in Wastewater Collection Systems

DeSoto County is not a water service provider and does not operate any

Design Recommendations

Module 9: Basics of Pumps and Hydraulics Instructor Guide

Engineering & Expertise Designing Pump Sumps

Appendix S Pump Station Evaluation

MUNICIPAL WASTEWATER PUMP STATION DESIGN PROBLEMS AND SOLUTIONS

CHAPTER 2: The Plumbing System

MOBILE FIRE - RESCUE DEPARTMENT FIRE CODE ADMINISTRATION

DIVISION OF WATER QUALITY CONSTRUCTION GRANTS & LOANS SECTION FAST TRACK AUDIT CHECKLIST

Flygt Ball Check Valves

Engineering & Expertise Designing pump sumps

Hydro International First Defense OK 110 Scour and Removal Efficiency Confirmation Tests November

CHAPTER Section 1 Inventory of Existing Sanitary Sewer Collection and Treatment Facilities

Design recommendations FOR PUMP STATIONS WITH LARGE CENTRIFUGAL FLYGT WASTEWATER PUMPS

N-PUMP SERIES FOR MAXIMUM RELIABILITY AND EFFICIENCY IN WASTEWATER HANDLING. Flygt

Lift Station Condition Assessment, Repair and Rehab the Full Monty. How to Participate Today

CENTRIFUGAL PUMP OVERVIEW Presented by Matt Prosoli Of Pumps Plus Inc.

MATHEMATICS FOR WATER OPERATORS

Flygt 2700 series. Corrosion resistant dewatering pumps. 60 Hz

Town of Essex NE Lagoon. Service Area. Essex Plant. Service Area. Pumping Station No. 4. Wastewater Pumped To NE Lagoons (Treatment Plant No.

Based on the above, it is recommended that Lift Stations #1 and #3 be abandoned and their flows be diverted to the regional Lift Station #8.

Wastewater Collection Practice Test #3 Page 1 of 15

Chapter 4 - Preferred Alternative...25

CONFIRMING WET WEATHER TREATMENT FACILITY HYDRAULIC DESIGN WITH PHYSICAL MODEL STUDY

Chapter 9 Sanitary Sewers

Centrifugal Fans and Pumps are sized to meet the maximum

Flygt 3068, 50Hz. Technical Specification

Sanitary Sewer Master Plan

Backup Sump Pump Systems. 1 NEXT

Pumps: Convert mechanical energy (often developed from electrical source) into hydraulic energy (position, pressure and kinetic energy).

Axial and Mixed Flow Pumps for Large Volume Pumping

Fire Pump Plan Review March 2010

Selection Of Centrifugal Pumping Equipment 1

CHAPTER 2 HYDRAULICS OF SEWERS

Design recommendations. for pump stations with large centrifugal wastewater pumps

Pacific Pump and Power

Energy Savings in Water and Wastewater Systems

Standard Hydraulic Piping Flushing Procedure

Overview. Introduction Cooling Tower Basics Principles of Operation Types of Cooling Towers Common Applications Design Considerations

Theory, Application, and Sizing of Air Valves

Review of Footing Drain Disconnection Projects

Texas Commission on Environmental Quality Page 1 Chapter Design Criteria for Domestic Wastewater Systems

ecmar SECTION INSTRUCTIONS: Sanitary Sewer Collection Systems

Guidelines for Precast Concrete Grease Interceptors

Conlift1, Conlift2, Conlift2 ph+

DATA COLLECTION AND PUMP ENERGY SAVING OPPORTUNITIES. Presented By: Rick Rumsey, P.E.

SECTION 1 UTILITY OVERVIEW, INTRODUCTION, and PROJECT BACKGROUND

COMPRESSION. Bureau of Forestry. Natural Gas Advisory Committee January 15, Presentation to the.

Illinois Environmental Protection Agency Division of Water Pollution Control Class K Study Guide Industrial Wastewater Operator Certification

Force Main Condition Assessment: New Technologies & Case Studies

Parkhill Road Sewage Pumping Station Class EA Study

HIGHWAY STORMWATER PUMP STATION DESIGN

4.0 SEWER LIFT STATION AND FORCE MAIN GUIDELINES

Grit Removal Systems Simple, low cost, effective grit removal to enhance plant performance

North Tahoe Public Utility District Main Sewer Pump Station Master Plan

SUMP PUMP. Sump Pump Backup Systems. City of Ann Arbor B A C K U P O P T I O N S. Does everyone need a backup system?

10/9/2012. Poultry Farm Water Supply. Alabama Burglar & Alarm System. Industry Upgrades. Drinkers Fans Water Supply

KESSEL KTP 500 Submersible Pump with lateral and vertical outlet connection Order Numbers 28710, 28810, 28850

Flygt N-Pumps 3085, 3102 & For reliable and efficient wastewater handling

THERE S NO USE CRYING OVER SPILLED SEWAGE: USING STANDBY LIFT STATION PUMPS TO PREVENT SSOS BEFORE THEY HAPPEN

Irrigation Efficiency Rewards

Federal Triangle Stormwater Working Group Federal Triangle Floodproofing Seminar BUILDING STRONG SM

Class Environmental Assessment Schedule B Project File Report

W HO W E ARE... AND W HAT W E DO...

Outline. Objective. Overview Sanitary Drainage System. Design. Materials

Maricopa Association of Governments. Technical Memorandum No. 1 INFRASTRUCTURE DEVELOPMENT COSTS. August 2001

Compact pumps from the wastewater experts. FLYGT 3045, 3057, Power range kw.

Pressure Reducing Valve Calculation Example

What Does A Sump Pump Do?

Wilo SP Series Submersible Sump Pumps ECS. ECS ECS ECS Installation and operating instructions

ANAEROBIC/ANOXIC TANKS

Fire Protection Pumps

How To Install An Overhead Sewer

Clean Water State Revolving Fund (CWSRF) Requirements and Guidance for a Fiscal Sustainability Plan (FSP)

GIS in Wastewater Collection System Master Planning

WATER MEASUREMENT USING TWO INCH (50 mm) DRAIN TESTS

TOWN OF SAUGEEN SHORES WATER AND SANITARY SEWER SERVICING MASTER PLAN 2014 REPORT

WWTP RETROFIT. Smith & Loveless Inc. Also in this issue: Do You Have Emergency Backup? Aging Clarifiers Retrofit to Like New

Asset Management Answering the 5 Core Questions

pvc well casing & drop pipe

GRIT CHARACTERIZATION IN FLORIDA WASTEWATER PLANTS

How Curve Shape Can Influence Pump Selection

CHAPTER 3 STORM DRAINAGE SYSTEMS

Septic System Management Plan for Below Grade Systems

BLADDER SURGE CONTROL SYSTEM

Sanitary Sewer Overflow (SSO) Incident Report Form

Indiana State Department of Health Construction Guidelines for Gravity and Flood-Dose Trench Onsite Systems

Practice Problems on Pumps. Answer(s): Q 2 = 1850 gpm H 2 = 41.7 ft W = 24.1 hp. C. Wassgren, Purdue University Page 1 of 16 Last Updated: 2010 Oct 29

Design Criteria & Service Goals

PRODUCT SELECTOR Pollution Control, Pumping and Rainwater Harvesting Systems

SECTION 9: Pumping Systems

DEPARTMENT OF ENVIRONMENTAL QUALITY

Transcription:

The Systems Approach to Lift Station Design, Operation, Installation and Maintenance

Xylem is a world leader in water handling and treatment. With global direct sales and service capabilities, we work closely with our customers to deliver energy-efficient and reliable solutions in more than 150 countries. Intelligent pumps and controls to transport water and wastewater Advanced treatment systems to clean and disinfect water Full-service dewatering capabilities including pump sales, rental and onsite services to remove unwanted water Advanced TotalCare service capabilities Integrated solutions combining world-class products and systems design expertise Flygt invented the world s first submersible sewage pump and continues to innovate with self-cleaning Flygt N technology ensuring efficient non-clogging performance.

HydroScrew Submersible VTSH Solids Handling Immersible Vortex Chopper

Speakers Barry Jongsma Manager of Product Engineering Pentair Ernest C. Sturtz, P.E., BCEE Associate CDM Smith Jim Vukich Application Engineer Xylem Flygt Products

Station Classifications Packaged Pre-Engineered Custom Complexity 5

What is the Systems Approach? Charlotte, N.C. 200 MGD Sugar Creek WRF Influent PS (2009) Images Used with Permission of CMU

Available Data for Creation of a Computer Model (Existing Systems) GIS Pipes Nodes Elevation Parcels Land use New Computer Model Pump Station DB Pumps Wet Wells Controls Customer Billing Database Water Demands Customer Type

Design of a Single Pump Station Gravity Collection System Boundary Population - 1,000 ADF - 60 gpm Peak factor -? Design flow -?

Examples of ADF and Population Based Peak Factors 5.0 Peak Factor 4.5 4.0 3.5 3.0 ADF Based Peak Factor Population Based Peak Factor 2.5 2.0 0 50,000 1,000,000 1,500,000 2,000,000 Flow (gpm)

Design of a Single Pump Station Gravity Collection System Boundary Population - 1,000 ADF - 60 gpm Peak factor - 3.80 Design flow - 230 gpm

Small Systems Are Easy to Design Pump Station #1 Pump Station #2 Capacity of pump station #2 must be equal to capacity of pump station #1

Large Manifolded Systems Are Another Matter

What is the Appropriate Size of the Re-Pump Station? Re-pump Station

Modeling Practice Limit Pumps in Operation Re-pump Station

Modeling Practice Discount Flows Re-pump Station

Preliminary Evaluation of Manifolded Systems Relative Size of Pump Station - Small - Medium - Large Re-pump Station - Less than MAF - Flow exceeds MAF - Flow exceeds design flow rate

Over Sizing Facilities can Cause as Much Trouble as Under Sizing 160 2000 PHF 2010 PHF 2020 PHF 140 120 ~800 gpm 100 TDH (feet) 80 60 18 40 20 0 0 1,000 2,000 3,000 4,000 5,000 6,000 Pump Flow (gpm) Existing Low Head - HWL Existing High Head - 2/3D Pump Perf ormance Curve

Step by Step Design of a Typical Pump Station

Municipal Design Code Requirements How many pumps are needed? A typical design should include permanentlyinstalled redundant pumping capacity equaling the largest single pump in a station Firm capacity = with one largest pump out of service

Understand Your Project New, upgrade or retrofit? New or existing force main? Present and future conditions?

Understand Your Project Owner expectations? Present and future conditions? Demographics? Zoning? Land usage?

What do We do First? Establish relevant design information Location of station Go visit the site! Location of discharge point Electrical requirements Find out actual line voltages Back-up power needs Utility supply limitations

What do We do First? Establish relevant design information, cont. Condition of existing installation and equipment Verify static head Find flow duration data Daily peak flows Daily min. flows 10, 25, 50 or 100 year flows Research existing force main data

Quick and rough design take-off System head loss calcs Use 6fps (based on daily peak flow) to rough out a force main size Calculate FM head loss Add ~5ft for station piping losses Don t add unnecessary safety factors!

Quick and rough design take-off Establish station design flow based on one of the year daily peak flows Duplex station 2 equal pumps, each sized for daily peak flow Standard concept Triplex station 3 equal pumps, each sized for ½ daily peak flow May yield better energy efficiency, more redundancy, and a lower LCC

Quick and rough design take-off Select pumps for both the duplex and triplex scenarios Establish the minimum station inside diameter based on: HI 9.8 intake design formula (section 9.8.2.3) I.D. based on the required minimum active wet pit volume Pump manufacturer s recommendations Decide on preliminary start-stop levels

HI 9.8 intake design formula for minimum station ID Warning: This formula may give a sump diameter that is too small verify pump start/hour and active sump volume D = 25 D + 2 C + C S. min b w b D = 2 D + 2 C + C min S b w b

Station Diameter & Minimum Active Volume Active volume is the volume between pump on and pump off (in a duplex station) Pump On Min. volume is dictated by allowed motor starts/hour Pump Off

How To Determine Minimum Active Volume Vmin. = (Tmin. x Q) 4 Where: Vmin = minimum active sump volume Tmin = minimum cycle time for fill-up and draw-down Q = pump flow rate To keep the size of the sump at a reasonable minimum, the pump capacity should be two times the inflow at critical or peak flow times

Quick and rough design take-off Make a decision Analyze the two station designs based on: Excavation volume ($/c.y.) Pump, valve, piping, accessory, and control cost ($) Energy usage (kw-hr) Redundancy (subjective value?) Complexity and general attractiveness (subjective value?) Calculate station LCC (total $ for life of station) Initial Cost Energy Cost Maintenance Cost

Final Design Process Use the Quick & Rough design as a basis to lay out final station and FM piping Make adjustments based on findings during the preliminary pump selections Be flexible with head loss and flow rates so that you can select pumps that operate close to BEP Use station piping that gives an average liquid velocity of 3-6 fps through fittings Use a FM diameter that satisfies your LCC analysis (often 4-7 fps)

Pump Selection Full Sump Full Sump Min Static Head New Pipe Minimum Friction Operating range

Pump Selection Head loss increase Full Sump Min Static Head Old Pipe Maximum Friction Operating range

Pump Selection Empty Sump Empty Sump Min Static Head New Pipe Old Pipe Operating range

Pump Selection All Together Operating range Empty sump 5 draw-down Full sump

Pump Operating Range

Summary Dry Well Pumping Station Wet Well Pumping Station

Don t miss SWPA s two-day Pumping Systems and Controls Training Seminar all based on the systems approach. April 9-10 Baltimore, MD Register by calling 847.681.1868 or visiting swpa.org. Today s webinar attendees may receive ½ off their registration.

Q & A To contact today s presenters, email: Barry Jongsma - Barry.Jongsma@pentair.com Ernest C. Sturtz - sturtzec@cdmsmith.com Jim Vukich jim.vukich@xyleminc.com Visit pump-zone.com to: view the answers to all of the questions asked during the Q&A session access the recording of the webinar or download the presentation The next webinar in the SWPA series will be on June 19, 2014. More details coming soon.