1020 Cable Electronics



Similar documents
Cable Pinouts. SRP I/O Module

RJ45 Shielded (standard) port pinout. CS9000, Jetstream , Lanstream 2000, RTA8/RJX, RRC16, MTA8/RJX & SXDC8/RJX

Cable Specifications and Information

Cable Specifications and Information

Making a DB to RJ45 adapter.

RS-232 COMMUNICATIONS

Encore Controller to Router Connections

RJ11 RS-232 Interface

16-Port RS232 to USB2.0 High Speed Multi Serial Adapter (w/ Metal Case) Installation Guide

Manual Serial PCI Cards

Connector and Cable Specifications

Cabling Guide for Console and AUX Ports

RS232C < - > RS485 CONVERTER S MANUAL. Model: LD15U. Phone: / 97 / 98 (M)

Hardware Reference. Linux Device Server IGW/922 with DIL/NetPC ADNP/9200

Comtrol Cable User Guide

Connector and Cable Specifications

maxon motor maxon motor control EPOS Positioning Controller Cable Starting Set Edition June 2006 part number Positioning Controller

Cable Specifications. T3 Trunk Cabling APPENDIX

RS-232 to TTL Converter Cables SuperDroid Robots

2-Port RS232/422/485 Combo Serial to USB2.0 Adapter (w/ Metal Case and Screw Lock Mechanism) Installation Guide

Power Supply and Cabling Options. SmartTrak 100/101/140

Revision Date: September 19, 2006

Connectors and Cables

Using HyperTerminal with Agilent General Purpose Instruments

PCMCIA 1 Port RS EDITION OCTOBER 1999

Auxiliary equipment for communication with the EuroProt protective devices

Connecting the Console Port to a PC

ARDUINO SEVERINO SERIAL SINGLE SIDED VERSION 3 S3v3 (REVISION 2) USER MANUAL

Cable Guide. Click on the subject to view the information. Digi Cables Building Cables General Cable Information

Advanced Data Capture and Control Systems

GM1200E Interface Cable

ETM9350-1/ Quick Start Guide

Modbus Communications for PanelView Terminals

How To Set Up A Modem (Marc) Model (Marc) Model 2 (Marr) Model 1 (Marm) Model 4 (Mariar) Model 8 (Marp) Model 6 (Mar

Table of Contents. Page Number. PLC Connections 1 Cable Solutions for Omron PLCs 11 Cable Solutions for Multi-Vendor PLCs 15

2-Port RS232/422/485 Combo Serial PCI Card

Installation Guide. AXIS 2191 Audio Module Sight, Speech and Sound over IP!

IPG/7700 Hardware Manual SYSTECH. Document number Revision A

VSCOM USB PRO Series Industrial I/O Adapters

TDAS G5-DB Hardware User s Manual

Frame Relay Cabling This section describes the cabling and connector pinouts for the Frame Relay cards.

Application Note 83 Fundamentals of RS 232 Serial Communications

XPort Universal Demo Board User Guide

IMMS-CCC. IMMS-CCC Hardwire Central Interface. Installation Instructions

SyncLink GT2/GT4 Serial Adapter

USB TO SERIAL ADAPTER

LAN / WAN Connection Of Instruments with Serial Interface By Using a Terminal Server

An0067. Cable-set Reference Guide. Rev December ETH_An0067_USM

RS-232 Cables, Wiring and Pinouts. Brief tutorial and pinouts for RS-232, T1/E1 and V.35. Contents

ALARMS-xx. Remote Alarm Unit Setup Guide RESET ALL

Gold Eagle HV Gold Eagle HV Cable Kit (EtherCAT and CAN)

1.1 Connection Direct COM port connection. 1. Half duplex RS232 spy cable without handshaking

Cabling Specifications

LMU Hardware and Installation Guide

INSTALLATION GUIDE. Card Reader & Controller with KIM Swipe Reader for Solitaire 850 / 950 / 850L Learnlok PK2930

APPLICATION NOTE. Leased Line Modem. Leased Line Modem...3. Introduction Key Concepts... 4

Roadstar Installation Instruction Manual

Connector and Cable Diagrams (Pinout Charts)

Elo Interactive Digital Signage (IDS): Remote Management

s!nus-elektrotechnikai bt. Industrial IT & Automation

RS-232/422/485, Power over Ethernet

Serial to Bluetooth Adapter

ISHIDA BC Scale to Scale Communications

Screen 3.5" Color Touch 4.3" Color Touch Keypad or Function Keys Programming Com Port, Built-in

Using a Laptop Computer with a USB or Serial Port Adapter to Communicate With the Eagle System

Cable Connection Procedures for Cisco 1900 Series Routers

ECR Shelf System Installation Guide Centralized Rack Mount Call Recording

Module Connectors and Cable Specifications

How To Connect A Directsofl To A Powerpoint With An Acd With An Ctel With An Dm-Tel Modem On A Pc Or Ipad Or Ipa (Powerpoint) With A Powerline 2 (Powerline

How to setup a serial Bluetooth adapter Master Guide

isco Connecting Routers Back to Back Through the AUX P

IPX AUTOMATIC IP NETWORK LOSS BACKUP A/B SWITCH INSTRUCTION BOOK IB

BIT COMMANDER. Serial RS232 / RS485 to Ethernet Converter

RS-422/485 Multiport Serial PCI Card. RS-422/485 Multiport Serial PCI Card Installation Guide

USB to serial chip CH340

Draper Low Voltage, Remote Control, Serial and Network Wiring Guide

Programming and Using the Courier V.Everything Modem for Remote Operation of DDF6000

Hardware Installation and Configuration Guide

RC2200DK Demonstration Kit User Manual

ELAN DIGITAL SYSTEMS LTD. SL232 PC- CARD USER S GUIDE

Data Bulletin. Communications Wiring for POWERLINK G3 Systems Class 1210 ABOUT THIS BULLETIN APPLICATION INTRODUCTION.

Automatic AES Change-Over

DEX28-VR3P Quick Installation Guide

INSTALLATION INSTRUCTIONS

WEB log. Device connection plans

Cable Specifications

VOICE RECORDING SYSTEM ISDN PRI / BRI

By4750. USB Serial Converter (RS232 RS485)

Gold Cello Gold Cello Cable Kit

When we look at the connector pinout of the RS232 port, we see two pins which are certainly used

1-Port R422/485 Serial PCIe Card

Appendix A. This Appendix includes the following supplemental material:

Dial-Up / Leased-Line Modem. User Manual. AGM Electronics, Inc Dial-Up / Leased-Line Modem, Series ( ) Manual Rev A + - DLM CTS RTS DTR DSR

Dynamax Inc Copyright

MDM192 MULTI-DROPS DIGITAL MODEM FOR PRIVATE LINE. USER GUIDE Document reference :

1 Contactless Smartcard Reader Setup

CDI-S100 SERIAL INTERFACE CARD

PUSH BUTTON START INSTALLATION MANUAL

MFRD52x. Mifare Contactless Smart Card Reader Reference Design. Document information

Transcription:

00 Cable Electronics Analog signal outputs There are two channels of analog output available on the back panel, labeled Sig and Sig. Two cables are available one for 33/ series integrators and one for general use. Analog cable GC to 33A/B or 33B/C Integrators and 300 C/D/E Analog to Digital Interface instrument Part no. G30-070 3 4 G30-070 3 * * next to triangle etched on connector Connector Signal Name Color Connector 4 V Black 3 Common White Shell Ground Orange Jun 00 Cabling Configuration and Electronics Agilent 80 Gas Chromatograph Service Manual of 8

00 Cable Electronics Analog signal outputs Analog cable general use Part no. G30-00 Shell 3 4 G30-00 Connector Signal name Connector quick disconnects 0 to mv ( ) Brown 0 to V, 0 to 0 V( ) White 3 0 to mv (+) Red 4 V (+) Black 0 V (+) Blue Shell Ground Orange of 8 Cabling Configuration and Electronics Jun 00 Agilent 80 Gas Chromatograph Service Manual

Cable Electronics 00 Automatic sampler, 80A GC Automatic sampler, 80A GC This RS-3C serial port (labeled sampler on the back of the GC) is preconfigured to connect the GC to an Automatic Liquid Sampler. Cable pinouts, 80 GC to Automatic Liquid Sampler Part no. G30-000 G30-000 Connector pin (female) Connector pin (female) DCD 4 DTR DSR Rx 3 Tx 3 Tx Rx 4 DTR DSR DCD Ground Ground 7 RTS 8 CTS 8 CTS 7 RTS RI Jun 00 Cabling Configuration and Electronics Agilent 80 Gas Chromatograph Service Manual 3 of 8

00 Cable Electronics Automatic sampler, 80 Plus and 80N GCs Automatic sampler, 80 Plus and 80N GCs 80 Plus GC s with serial numbers > 0,000 require an additional PCB for use with an automatic liquid sampler. When an ALS Interface PCB is installed, three connectors are available for the 783 Autosampler system. 80N There are three connectors, Sampler, Sampler, and Tray, for the 783 Autosampler system. Cable pinouts, 80 Plus/80N GC to G3A Injector Part no. G3-00 Connector pin (female) Connector pin (female) A RXD A TXD A CTS A RTS A3 DSR A3 DTR A4 NCTL Reset A4 NCTL Reset A GND A GND A VAC A VAC A7 GND A7 GND A8 VAC A8 VAC B TXD B RXD B RTS B CTS B3 DTR B3 DSR B4 GND B4 GND B GND B GND B VAC B VAC B7 GND B7 GND B8 VAC B8 VAC 4 of 8 Cabling Configuration and Electronics Jun 00 Agilent 80 Gas Chromatograph Service Manual

Cable Electronics 00 Automatic sampler, 80 Plus and 80N GCs Cable pinouts, 80 Plus/80N to G4A Tray Part no. G4-00 Connector pin (female) Connector pin (female) A RXD A TXD A CTS A RTS A3 DSR A3 DTR A4 M Reset A4 M Reset A GND A GND A VAC A VAC A7 GND A7 GND A8 VAC A8 VAC B TXD B RXD B RTS B CTS B3 DTR B3 DSR B4 GND B4 GND B GND B GND B VAC B VAC B7 GND B7 GND B8 VAC B8 VAC Jun 00 Cabling Configuration and Electronics Agilent 80 Gas Chromatograph Service Manual of 8

00 Cable Electronics BCD Inputs BCD Inputs 80A and 80 Plus The BCD cable is used to read the position of a stream selection valve, headspace sampler, or other device. It consists of eight passive inputs that sense open/closed contacts. If you are using a multiposition (stream selection) valve, you must also have an external event cable. Part no. G30-030 8 8 G30-030 BCD Unterminated Connector pin (male) Signal name Logic Color LS digit 0 Low (true) Black LS digit Low (true) Brown 3 LS digit Low (true) Red 4 LS digit 3 Low (true) Orange,, 7 Unused 8 Ground Gray, 0, Unused MS digit 0 Low (true) Yellow 3 MS digit Low (true) Green 4 MS digit Low (true) Blue MS digit 3 Low (true) Violet of 8 Cabling Configuration and Electronics Jun 00 Agilent 80 Gas Chromatograph Service Manual

Cable Electronics 00 BCD Inputs 80N The connector provides the control relays and a BCD input for a stream selector Multi Valve. 8 BCD Connector Pin Function Color Maximum rating Relay Yellow 48 V AC/DC, 0 ma Relay Black 48 V AC/DC, 0 ma 3 LS digit 0 Red 4 LS digit White LS digit Orange LS digit 3 Green 7 MS digit 0 Brown or Violet 8 GND Blue Shield Chassis GND Jun 00 Cabling Configuration and Electronics Agilent 80 Gas Chromatograph Service Manual 7 of 8

00 Cable Electronics External event External event Two passive relay contact closures and two 4-volt control outputs are available for controlling external devices. Devices connected to the passive contact closures must be connected to their own power source. Part no. G30-00 7 8 3 4 Connector G30-00 Wire terminations Connector Signal name Maximum rating Wire terminations 4 volt control output 4 volt output 7 ma Yellow 4 volt output 7 ma Black 3 Ground Red 4 Ground White Relay contact closures (Normally open) Contact closure 48V ac/dc, 0 ma Orange 7 Contact closure Green 7 Corresponds to valve # 7 Contact closure 48 V ac/dc, 0 ma Brown or Violet 8 8 Contact closure Blue 8 8 of 8 Cabling Configuration and Electronics Jun 00 Agilent 80 Gas Chromatograph Service Manual

Cable Electronics 00 Modem/RS-3C Modem/RS-3C Cable pinouts, 80 GC to Computer via RS-3, -pin/-pin Part no. G30-000 G30-000 Connector pin (female) DCD DSR Connector pin (female) 4 DTR Rx 3 Tx 3 Tx Rx 4 DTR DSR DCD Ground Ground 7 RTS 8 CTS 8 CTS 7 RTS RI Jun 00 Cabling Configuration and Electronics Agilent 80 Gas Chromatograph Service Manual of 8

00 Cable Electronics Modem/RS-3C Cable pinouts, 80 GC to Computer via RS-3, -pin/-pin Part no. G30-00 4 G30-00 3 3 Connector pin (female) DCD DSR Connector pin (male) 0 DTR Rx Tx 3 Tx 3 Rx 4 DTR DSR 8 DCD Ground 7 Ground 7 RTS CTS 8 CTS 4 RTS RI 0 of 8 Cabling Configuration and Electronics Jun 00 Agilent 80 Gas Chromatograph Service Manual

Cable Electronics 00 Modem/RS-3C Cable pinouts, 80 GC to Modem, pin/-pin Part no. G30-0 G30-0 Connector pin (female) Signal name DEC RxD 3 TxD 3 4 DTR 4 GND DSR 7 RTS 7 8 CTS 8 RI (Unused) Connector pin (male) Jun 00 Cabling Configuration and Electronics Agilent 80 Gas Chromatograph Service Manual of 8

00 Cable Electronics Modem/RS-3C Cable pinouts, 80 GC to Modem, -pin/-pin Part no. 440-800 or 44M 4 440-800 3 3 Connector pin (female) Signal name DCD 8 RxD 3 3 TxD 4 DTR 0 GND 7 DSR 7 RTS 4 8 CTS (Unused) Connector pin (male) of 8 Cabling Configuration and Electronics Jun 00 Agilent 80 Gas Chromatograph Service Manual

Cable Electronics 00 Remote Remote Cable pinouts, remote start/stop, general use Part no. 300-070 300-070 Connector pin (male) Signal name Connector (spade lugs) GND Black Prepare (low true) White 3 Start (low true) Red 4 Shut down (80A/Plus); start relay (80N) Green Reserved (80A/Plus); start relay (80N) Brown Power on (80A/Plus); no connection (80N) Blue 7 Ready (high true input) Orange 8 Stop (low true) Yellow Start request (80A/Plus); no connection (80N) Violet Jun 00 Cabling Configuration and Electronics Agilent 80 Gas Chromatograph Service Manual 3 of 8

00 Cable Electronics Remote Cable pinouts, GC to 300C, D, E/MSD/Sampler, meters Part no. G30-030 G30-030 Connector (male) Signal name GND Prepare 3 Start 3 4 Shut down (80A/Plus); start relay (80N) 4 Reserved (80A/Plus); start relay (80N) Power on (80A/Plus); no connection (80N) 7 Ready 7 8 Stop 8 Start request (80A/Plus); no connection (80N) Connector (male) 4 of 8 Cabling Configuration and Electronics Jun 00 Agilent 80 Gas Chromatograph Service Manual

Cable Electronics 00 Remote Cable pinouts, 80 GC to 33A/33B Integrator Part no. 033-00 033-00 8 Connector pin (male) Signal name Connector pin (male) GND Ground Prepare NC* 3 Start 3 Start in 4 Shut down (80A/Plus); start relay (80N) NC* Reserved (80A/Plus); start relay (80N) NC* Power on (80A/Plus); no connection (80N) NC* 7 Ready 4 Ready out 8 Stop NC* Start request (80A/Plus); no connection (80N) NC* *NC = no connection Jun 00 Cabling Configuration and Electronics Agilent 80 Gas Chromatograph Service Manual of 8

00 Cable Electronics Remote Cable pinouts, 80 GC to 33B/33C Integrator Part no. 033-00 033-00 8 Connector pin (male) Signal name Connector pin (male) GND Ground Prepare NC* 3 Start 3 Start in 4 Shut down (80A/Plus); start relay (80N) NC* Reserved (80A/Plus); start relay (80N) NC* Power on (80A/Plus); no connection (80N) NC* 7 Ready 4 Ready out 8 Stop 4 STOP In Start request (80A/Plus); no connection (80N) NC* *NC = no connect of 8 Cabling Configuration and Electronics Jun 00 Agilent 80 Gas Chromatograph Service Manual

Cable Electronics 00 Remote Cable pinouts, 80 GC to 74 Headspace Sampler Part no. G0-07 To ground screw 7 3 G0-07 4 3 Connector 3-pin male Signal name GND 4, 3 Start 7 Ready 3 Connector 4-pin male Jun 00 Cabling Configuration and Electronics Agilent 80 Gas Chromatograph Service Manual 7 of 8

00 Cable Electronics Remote Cable pinouts, APG Remote Y-cable Part no. G30-00 Connector pin (male) Signal name GND Prepare 3 Start 4 Shut down (80A/Plus); start relay (80N) Reserved (80A/Plus); start relay (80N) Power on (80A/Plus); no connection (80N) 7 Ready 8 Stop Start request (80A/Plus); no connection (80N) 8 of 8 Cabling Configuration and Electronics Jun 00 Agilent 80 Gas Chromatograph Service Manual