High Density Data Center Cabling



Similar documents
Data Center Infrastructure Solution

AMP NETCONNECT Data Center Cabling Solutions

AMP NETCONNECT CABLING SYSTEMS FOR DATA CENTERS & STORAGE AREA NETWORKS (SANS) High-density, High Speed Optical Fiber and Copper Solutions

24 fiber MPOptimate Configuration and Ordering Guide

Intelligent Infrastructure Management System

Know Your Network. managed connectivity. Transforming Your Physical Layer into a Strategic Asset

Data Center.

AMP CO Ultra System Catalog

The AMP NETCONNECT Cabling System Products

Arista and Leviton Technology in the Data Center

Table of Contents. Fiber Trunking 2. Copper Trunking 5. H-Series Enclosures 6. H-Series Mods/Adapter Panels 7. RSD Enclosures 8

Data Center Network Infrastructure The Smart Choice For Your Data Center

Data Center Cabling Design Trends

Data Centre Functional Areas

Data Center Market Trends

Data Center Infrastructure Development

InstaPATCH ZERO Solution Guide

Data Center Infrastructure Solution

SIEMON Data Center Solutions.

Data Center. Pre-terminated. Patch Panel System. Cabling Systems Simplified. Patch Panels. 10G + Gigabit. Patch Cords. Plug & Play Installation

Cisco IT Data Center and Operations Control Center Tour

DATA CENTER NETWORK INFRASTRUCTURE. Cable and Connectivity for the Most Demanding Networks. BerkTekLevitonTechnologies.com

High density Fiber Optic connections in the Data Center. Phil Ward Datacenter Product Market Manager. HUBER+SUHNER AG

Intelligent Infrastructure Management System (IIMS)

AMPTRAC TM CONNECTIVITY MANAGEMENT SYSTEM

Data Center Topology Guide

How To Make A Data Center More Efficient

Quick Reference Guide High Speed Input/Output Solutions

Issues Affecting the Design and Choice of Cabling Infrastructures within Data Centres

Living Infrastructure Solution Guide.

DATA CENTRES POWERED BY EXCEL

Zone Distribution in the Data Center

E-Seminar. Financial Management Internet Business Solution Seminar

by knürr CoolTherm Server cabinet technology with outstanding benefits up to 35kW cooling capacity Blade-Server server optimized!

How To Build A Powerline Box Powerline Generator

Living Infrastructure

ADC-APC Integrated Cisco Data Center Solutions

AMP NETCONNECT. EMEA Product Catalog

SECURE Fiber Optic Products

Data Center Architecture with Panduit, Intel, and Cisco

The big pay turnaround: Eurozone recovering, emerging markets falter in 2015

The migration path from 10G to 40G and beyond for InstaPATCH 360, InstaPATCH Plus and ReadyPATCH installations

Top of Rack: An Analysis of a Cabling Architecture in the Data Center

Obsolete Fiber Technology? Not in my Data Center!

Optimizing Infrastructure Support For Storage Area Networks

M8 / M12 CONNECTOR SYSTEM

Innovation. Volition Network Solutions. Leading the way in Network Migration through Innovative Connectivity Solutions. 3M Telecommunications

High Speed Data Networking for the Automotive Market

Migration Strategy for 40G and 100G Ethernet over Multimode Fiber

DATA CENTER DESIGN BEST PRACTICES: EFFICIENCIES BEYOND POWER AND COOLING

MPO. Fast Fibre Solution for Data Centres

UC PRECON The Pre-terminated cabling solution for network infrastructures in offices and data centres. A dependable, fast and always available part

HUBER+SUHNER AG Phil Ward

CISCO METRO ETHERNET SERVICES AND SUPPORT

Excel Pre-terminated Copper and Fibre Optic Systems

DATA CENTER SOLUTIONS GUIDE

Managing High-Density Fiber in the Data Center: Three Real-World Case Studies

Cisco Conference Connection

WD Hard Drive Interface Guide

IP Networking and the Advantages of consolidation

Network/Multimedia Cables

Maintaining Proper Polarity for Modular Pre-terminated Fiber Systems. Rudolph A. Montgelas Fiber Optic Senior Product Manager Ortronics/Legrand

Plug & Play Gigabit Ethernet Media Conversion Module. Application Note

Storage Area Management (SAM) Clutter-Free, Super-Efficient Network Infrastructure Management

Sustaining the Cloud with a Faster, Greener and Uptime-Optimized Data Center

Storage Area Management (SAM) Clutter-Free, Super-Efficient Network Infrastructure Management

GLOBAL DATA CENTER INVESTMENT 2013

SummitStack in the Data Center

Data Center Optimization: Component Choice. Innovative Design. Enabling Infrastructure

AMPTRAC CONNECTIVITY MANAGEMENT SYSTEM

Keysight Technologies Connecting Data Acquisition Systems to a Wireless Network

How To Make A Fibre Cable For A Data Centre

Secure/Keyed LC System Solutions Overview

MapIT G2 Infrastructure Management

NEBS 2009 Optimization of Telecom Networks Through Energy Efficiency Eitan Amon Type Approval Team Leader Comverse Ltd.

Fiber Systems. Best Practices for Ensuring Polarity of Array-Based Fiber Optic Channels

Simplifying Data Center Network Architecture: Collapsing the Tiers

HIGHSPEED ETHERNET THE NEED FOR SPEED. Jim Duran, Product Manager - Americas WHITE PAPER. Molex Premise Networks

Data Center Solutions

2015 Growth in data center employment continues but the workforce is changing

Health Care Solutions

As today s evolving data centers

Cisco 2-Port OC-3/STM-1 Packet-over-SONET Port Adapter

Integrate 10 Gb, 40 Gb and 100 Gb Equipment More Efficiently While Future-Proofing Your Fiber and Copper Network Infrastructure

The Need for Low-Loss Multifiber Connectivity

Integrated telecommunication solutions

SummitStack in the Data Center

How To Get The Ifs Cloud On Microsoft Azure 2.5 On A Microsoft Cloud On A Cloud On An Ios (Cloud) On A Server On A Supermicrosoft Cloud (Cloud On A Mini

Copper Pre-terminated Assemblies

Anixter ipassured SM for Data Centres. Products. Technology. Services. Delivered Globally.

GEU Port Gigabit Switch

ADC s Data Center Optical Distribution Frame: The Data Center s Main Cross-Connect WHITE PAPER

Sulfuric Acid 2013 World Market Outlook and Forecast up to 2017

CISCO AIRONET POWER INJECTOR

Unified Physical Infrastructure (UPI) Strategies for Data Center Networking

THE KEY TO DATA CENTRE INFRASTRUCTURE

Cisco Catalyst 6500 Series/Cisco 7600 Series Supervisor Engine 720-3BXL

Cabcon. Data Centre Solutions. an acal group company UK +44 (0) IRE (00353)

Agilent 4339B/4349B High Resistance Meters

The Need for Speed Drives High-Density OM3/OM4 Optical Connectivity in the Data Center

Transcription:

High Density Data Center Cabling

Introduction Data Centers are the nerve centers of the new economy special environments that boast the latest technology and computing processes. The purpose of the data center is to centralize and consolidate IT resources, thereby giving business the infrastructures that offer 24/7 availability, 365 days a year. Designed to offer around the clock business continuity and uninterrupted services for mission critical data operations, they often have different requirements to that of traditional office network physical layer systems. Plug&Go Tyco Electronics offers the products you need for quick and easy installation of high-performance Data Center and Storage Area Networks. Combining pre-terminated cable assemblies and compact break-out cassettes makes installation as simple as Plug&Go : Mount the cassettes in a rack or wallmount box, lay the trunk cables, and plug the cables into the cassettes! Data Center Requirements 100% availability Fail-safe reliability and continuous monitoring Power and network communications redundancy and path diversity Physical and network access security and surveillance Zoned environmental control Intelligent systems to facilitate Moves, Adds and Changes (MACs) Networks can be up and running in minutes, not hours or weeks. No tool kits or consumables are necessary; no field-testing and no training is required all this results in minimized overall cost. Additionally, all cables and cassettes are factory-terminated and tested, so the high-performance you need is built into the products... Save Cost from the Very Beginning

Background / Technology Specifically Engineered Data Center Solution Cabling is often taken for granted but making the right investment will initially save time, money and frustration in the short term and minimize disruptive upgrades in the future. The requirements for Data Center or Storage Area Network cabling differ from those of traditional structured office cabling networks: Capability of handling huge data streams at the fastest possible rate Fast deployment and changes Higher density Highest reliability ( Zero Downtime) Top Products for Top Performance To meet these requirements Tyco Electronics has developed an application specific cabling system specially designed for Data Center and SAN. A factory terminated Plug&Go system for both, Twisted Pair and Fibre Optic. MPO Connector Utilizes the high-density MT-Ferrule 12 fibers per ferrule on only 3 mm 2 Very accurate fiber positioning Full 10 Gb/s support MRJ21 Connector Very compact metal connector with 48 pins Resistant against mechanical loads Factory terminated and tested to ensure reliable transmission parameters Full 10/100/1000 Ethernet support Interferometer graph of MT ferrule surface shows the accuracy of the 12 fibers High-Frequency Structure Simulator Software allows emulation and testing of electromagnetic connector characteristics High-Tech, High-Speed, High-Density 1

Protect and Segregate Your Data Network Physical Security Whether it s a military installation, a multiple data center suite, a financial institution or a local secure network, protecting and segregating your data can be a monumental task. With off-site server space in high demand for security reasons, many companies are offering services to multiple clients in one location, often within feet, or even inches of other clients (some of who may be competitors of the client). Our multi-color offering makes it intuitively obvious which jack or adapter will accept each plug (and which will not), thus greatly reducing that risk by simply using a color code to segregate each client. Color Coded and Mechanically Keyed Those requirements may apply to the following areas Military Insurance companies Financial institutions Industrial applications Our copper and fiber systems have a unique keying system, identified with easy to recognize color coding (each colored connector will only fit into the corresponding jack). The fiber solutions are available with either traditional through couplers or MPO cassette based systems. These systems allow 100% accurate service connectivity all of the time, with further benefits for Data Center operators: Physical and optical segregation of multiple clients or services in one Data Center Easy service assignment Errors excluded 2 Physical Connectivity Security

Partnership with Manufacturers of LAN Electronics One Design for LAN Electronics Connectivity and Cabling Systems Tyco Electronics is the world's largest manufacturer of electrical and electronic connectors. With our knowledge and experience we develop and engineer visionary connectivity technology. While we are integrating our advanced connectors into our own products to offer best in class cabling systems, we also collaborate closely with manufacturers of IT devices that connect directly to our cabling systems. Consequently, Tyco Electronics supplies the same high-tech connectivity to various switch and server manufacturers to provide really seamless End-to-End System solutions to data center users around the globe. The MRJ21 48 pin copper connector is integrated on switch blades and server cards. A perfect inter-balance between high-density connectivity for high-speed switches and an innovative cabling system solution ensures maximum throughput and reliability. The list of suppliers comprises many major network companies, which supply active enterprise solutions for Data Centers. Ask your supplier about MRJ21 high density solutions. Complete Solution Strategy 3

MPO Fiber Optic System Solution The MPO system is an excellent choice for many fiber applications. Modular components are the key to fast deployment, simple installation, capital effectiveness and network flexibility. Pre-terminated trunk cables, breakout cassettes and cable assemblies are the basic modular components needed for a complete network. MPO Trunk Cables Factory terminated and tested high-density MPO connectors 12 fibers per connector MPO push-pull type connectors Available in various length (10 m to 300 m) and fiber types (OM1, 2, 3 or OS2) MPO Snap-in Cassettes These breakout cassettes are transitions between MPO and standard interfaces (LC, SC, MT-RJ) Fit into 19 patch panels (up to 3 cassettes per 1U) or wall mount enclosures (up to 6 cassettes) Suitable for 12 or 24 fibers per cassette Allow up to 72 fibers per 1U MPO Fan-out Cable Assemblies From distribution cable to single fibers Couples with MPO adaptors Available in LC, SC Duplex, MT-RJ or ST Reduces the need for patch panels Pre-terminated and Factory Tested 4 High-Density Fiber

MRJ21 Copper System Solution The MRJ21 system is a high-density, high-performance modular system. This Tyco Electronics solution is designed to deliver multiple Gigabit Ethernet ports in a high-density package that fully supports PoE. The twenty-four pair cabling and connector solution supports any plug and play environment including Data Centers. MRJ21 trunk cables, cassettes and cable assemblies are the basic components of this modular connectivity solution. MRJ21 Trunk Cables 48 pin MRJ21 connectors terminated to high-performance powersum 24 pair cables Factory terminated and tested Available in various length (1 m to 90 m) and jacket types Reverse polarity protection MRJ21 Snap-in Cassettes These breakout cassettes are transitions between MRJ21 and RJ-45 interface 6 port cassettes for 1000Base-T (4 pair service) 12 port cassettes for 10/100Base-T (2 pair service) Also available as fully integrated 19 patch panel Allows up to 48 RJ-45 ports per 1U MRJ21 Fan-out Cable Assemblies Application specific MRJ21 to 6 RJ-45 plugs (1000Base-T, 4 pair) MRJ21 to 12 RJ-45 plugs (10/100Base-T, 2 pair) For building Service Presentation and reduction of discrete links Pre-terminated and Factory Tested High-Density Copper 5

Better Cooling Performance Reducing Power Consumption with Smart Cabling Systems The accelerated adoption of dense computing systems, such as 1U servers and consolidated blade servers, is rapidly raising power consumption and heat emissions within the enterprise data center. Historically, the average 42 U rack has a power consumption of anywhere from 2 kilo Watts (kw) to 7 kw. Contrast this with the new generation of blade servers, which exhibit peak rack heat loads from 15 kw to 25 kw. Your Contribution to the Environment The graph below shows that approximately 12% of the total power consumption with in the data center can be attributed the network equipment and associated cabling. The accelerated adoption of dense computing systems requires the need for increased network performance. Areas Contributing to Power Consumption 6 Less Cooling = Less Power Consumption

Hi-D Connect Efficient Cable Management Increasing Density Whilst Reducing Power Consumption In line with the desire of organisations to provide more performance in less space within their Data Center environment whilst meeting power consumption objectives, AMP NETCONNECT has realised the need to develop focused product sets for these environments that meet the design objectives of guaranteed high density performance, seamless migration and user flexibility at a reduced power level. This provides some advantages: Better airflow in racks and raised floors Less power consumption Allows cost efficient cold and warm areas Using smart cabling to improve spaces and airflows, active cooling can be focused on the areas where high heat dissipation is require and not be wasted on cooling traditional passive cable systems. Using pre-terminated systems has the additional advantage of flexibility, beeing able to allow adds, moves and changes within minutes. Compared to traditional cable solutions, the AMP NETCONNECT Hi-D connect system can provide many cost benefits, including: Up to 20% reduced floor space Between 10% and 20% less maintenance time Up to 5% less power consumption In total up to 20% cost saving Managing the Highest Density 7

Return on Investment Time Field Installation vs. Plug&Go 60 Fiber Optic Twisted Pair Job Field Plug&Go installed Cabling Cabling Cable Laying Cable Termination Cable Testing On Field On Field On Field On Field Factory Terminated Factory Tested Space & Multiple runs High count Work take more single run Manship space and takes less dressing space and time time Installation Time in Minutes 50 40 30 20 10 0 Epoxy Epoxyless MT-RJ MPO For 12 Core Fiber Cables For 6 Links of 4 Twisted Pairs Money Higher initial material invest is compensated by saving labor (installation, testing) secondary cost (less/smaller pathways, no consumables, etc.) Conclusion: Initial invest for Plug&Go and Field Installation is neutral in cost! Actual saving begins from day one due to easier admin & maintenance when MACs are required (easier and faster connecting/disconnecting). Relative Cost Installation Cost 1,0 0,8 0,6 0,4 0,2 0,0 Plug&Go Field Installation Secondary Cost (Pathways, Consumables) T otal Cost of Ownership Operation Cost Year 1 2 3 4 5 Plug&Go Field Installation Labor Cost (Installing, Testing) Material Cost (Connectivity) 8 Time is Money

Key Features This Plug&Go System is...... simple and fast: Building up the system is as simple as pushing a power plug into its socket Connectors click into their adapters and are reverse polarity protected Cassettes snap into any slot that holds a snap-in adapter 48 pins plugged at once!... modular and adaptable with only three components: Trunk cables in various lengths Snap-in cassettes and break-out panels in various port counts Fan-out cable assemblies for even more flexibility... high-density: Up to 72 fibers (MPO) or 48 RJ-45 ports (MRJ21) per 1U Up to 96 fibers (MPO) or 24 twisted pairs (MRJ21) per trunk cable More performance in less space Less cables save cabinet and pathway space... scalable: Modular, pre-terminated and re-pluggable components simplify data network changes and growth Capital investment is scalable... reliable: Cables terminated and tested in a factory environment High precision processes Outstanding quality control... cost efficient: Reduced labor cost for installation, terminating and testing Reduced secondary cost for trunking, cabinet and consumables Competetive Advantages

AMP NETCONNECT Regional Headquarters: North America Harrisburg, PA, USA Ph: +1-800-553-0938 Fx: +1-717-986-7406 Latin America Buenos Aires, Argentina Ph: +54-11-4733-2200 Fx: +54-11-4733-2282 Europe Kessel-Lo, Belgium Ph: +32-16-35-1011 Fx: +32-16-35-2188 Mid East & Africa Cergy-Pontoise, France Ph: +33-1-3420-2122 Fx: +33-1-3420-2268 Asia Hong Kong, China Ph: +852-2735-1628 Fx: +852-2735-1625 Pacific Sydney, Australia Ph: +61-2-9554-2600 Fx: +61-2-9554-2519 AMP NETCONNECT in Europe, Mid East, Africa and India: Austria Vienna Ph: +43-1-90560-1204 Fx: +43-1-90560-1270 Belgium Kessel-Lo Ph: +32-16-35-1011 Fx: +32-16-35-2188 Bulgaria Sofia Ph: +359-2-971-2152 Fx: +359-2-971-2153 Czech Rep./Slov. Kurim Ph: +420-541-162-112 Fx: +420-541-162-132 Denmark Glostrup Ph: +45-70-15-52-00 Fx: +45-43-44-14-14 Finland Helsinki Ph: +358-95-12-34-20 Fx: +358-95-12-34-250 France Cergy-Pontoise Ph: +33-1-3420-2122 Fx: +33-1-3420-2268 Germany Langen Ph: +49-6103-709-1547 Fx: +49-6103-709-1219 Greece/Cyprus Athens Ph: +30-210-9370-396 Fx: +30-210-9370-655 Hungary Budapest Ph: +36-1-289-1007 Fx: +36-1-289-1010 India Bangalore Ph: +91-80-4011-5000 Fx: +91-80-4011-5030 Italy Collegno (Torino) Ph: +39-011-4012-111 Fx: +39-011-4012-268 Lithuania Vilnius Ph: +370-5-2131-402 Fx: +370-5-2131-403 Netherlands Den Bosch Ph: +31-73-6246-246 Fx: +31-73-6246-958 Norway Nesbru Ph: +47-66-77-88-99 Fx: +47-66-77-88-55 Poland Warsaw Ph: +48-22-4576-700 Fx: +48-22-4576-720 Romania Bucharest Ph: +40-21-311-3479 Fx: +40-21-312-0574 Russia Moscow Ph: +7-495-790-7902 Fx: +7-495-721-1894 Spain Barcelona Ph: +34-93-291-0330 Fx: +34-93-291-0608 Sweden UpplandsVäsby Ph: +46-8-5072-5000 Fx: +46-8-5072-5001 Switzerland Steinach Ph: +41-71-447-0-447 Fx: +41-71-447-0-423 Turkey Istanbul Ph: +90-212-281-8181 Fx: +90-212-281-8184 Ukraine Kiev Ph: +380-44-206-2265 Fx: +380-44-206-2264 UK Stanmore, Middx Ph: +44-208-420-8140 Fx: +44-208-954-7467 1308781-3 1M DE 03/07 TYCO ELECTRONICS, AMP NETCONNECT, MPO and MRJ21 are trademarks. 2007 Tyco Electronics All rights reserved http://www.ampnetconnect.com/emea