Name, department/event, date High Reliability with ABB Disconnector ABB



Similar documents
OUTDOOR DISCONNECTORS A division of ACTOM (Pty) Ltd

Disconnectors and Earthing Switches 36 kv up to 800 kv

SF 6 Gas Insulated Switchgear Type SDF for 170 kv

Vertical Break Parallel (VBP) / Vertical Break Slant (VBS)

MEDIUM VOLTAGE CE-BF SWITCHBOARDS. UP TO 40.5 kv. CE - BF - C - en - REV

3.1.1 Full Type Tests & Routine Tests according to Clause 8 2 & Instructions For Installation, Operation & Maintenance

METAL-CLAD AND METAL-ENCLOSED SWITCHGEAR 3.6KV~40.5KV. tgood.com. Energy. Fast.

AutoLink Three-Phase Sectionalizer Specifications. Scope. General. Applicable Standards. Operating principle

Transformer oil cooler ALFA A02

Modular Systems, PPMV, 2014 UniPack-G Glass Fiber Reinforced Polyester Compact Secondary Substation

The Intelligent AX1 Switchgear for Medium Voltage

RAILWAY CATENARY SYSTEMS. Components and Systems for the Electrification of Railway Lines. ibemo

DISCONNECTORS AND LOAD SWITCHES for railways

MEDIUM AND HIGH VOLTAGE CAPACITORS, CAPACITOR BANKS AND SYSTEMS

Paper on Basbar Trunking System for Electrical Supply to Industrial & commercial Installation

Our brand POWER DYNAMIC PASSION COMMITMENT CREATIVITY. A strong brand for strong products: 8PU Premium. MV Energy

Aerial Fibre Optics. Complete One Stop Solution for Aerial Fibre Optics. OPGW Cable and Fittings for OPGW

Modular Systems wind portfolio overview Power Collection and Grid Connection products

Type-Tested Power Distribution Board 8PT with Rear Busbars. sivacon

22 kv ISOLATORS & ISOLATOR CUM EARTHING SWITCHES

FAQs-Main switchboard design criteria

PTFE Slide Bearings 04/10 149

Fundamentals of Modern Electrical Substations Part 1: Mission of Electrical Substations and their Main Components

Circuit Breaker LTB D with Motor Drive. Motor Drive. ABB PP/H/HV - Page 1. Ed

All work must conform to the National Electric Code, latest edition, and all other applicable codes and regulations.

Unified requirements for systems with voltages above 1 kv up to 15 kv

High-Voltage Compact Switchgear 3AP1 DTC for 145 kv and 245 kv

ELEKTROTEHNI KO PODJETJE Leskoπkova cesta 12, 1000 Ljubljana, SLOVENIA

INSTRUCTION MANUAL (WINDOW WIPER)

NATUS NES / NES-H Draw-out Type Medium Voltage Switchgear Systems. Safe energy distribution that meets the highest industrial requirements

LV MCC LOW VOLTAGE SWITCHGEAR MOTOR CONTROL CENTRE PRODUCT GUIDE

High Voltage Circuit Breakers 3AP Type 72.5 kv to 800 kv Answers for energy.

SICONT Limit Switches Type 3SE3 upto 500 VAC, 600 VDC, 10A

AUTOMATIC TRANSFER SWITCH. Changeover Type from 250A to 2500A

2a. IEM Indoor Metal Clad Medium Voltage Switchgear 15KV a. Section INDOOR METAL CLAD MEDIUM VOLTAGE SWTICHGEAR (Std.

Distribution Boards & Consumer Units

Dead Tank Circuit Breaker 72PM40-C Proven reliability through common platforms

MNS is Switchgear System Technical Overview

Aluminium Standard. Technical Data. Included in delivery

SIVACON The Versatile Low-Voltage Switchboard

Oil and Coolant Circulating Heating System. Model - OCSM

Advantages of Fixed Circuit Breaker Switchgear

HVL 5 38 kv Load Interrupter Switchgear. The Standard for Performance, Protection and Dependability

MONDOATHENS BASKETBALL SET (Reference PK110)

SECTION PACKAGED ROOFTOP AIR CONDITIONING UNITS NON-CUSTOM

SECTION PACKAGED ROOFTOP AIR CONDITIONING UNITS

Pump Skid Fabrication for Magnetic Coupling. Rick Soltis Chief Mechanic City of Bedford

RAUFOSS EXPLOSIVE COMPRESSION FITTINGS

AC Electric Motors best practice

MODEL HSR-007 Direct Drive Rolling Steel

TP-C2 Motor Operator CLEAVELAND / PRICE INC. Bulletin DB-111B12

FFI. Advances in Medium and Low Voltage Power Distribution ESS Metron Expo and Technical Seminars. Presented By: Greg Pelster & Robert Schmid

PPS-PPQ-BT-PIAS RESIN INSULATORS FOR OIL INSULATED ELECTRICAL MACHINES

Low Voltage Switchboards The Best Technical Solution for Your Ship

Pressure monitoring equipment for oil-sf 6. bushings, type GOEK

OLI. Oil level indicator

INTERNATIONAL POWER DISTRIBUTION CONGRESS CIDEL ARGENTINA 2002

Secondary Unit Substations

CRN A-F-G-E-HQQE 3x400D 50 HZ

James M. Pleasants Company

MNS Low Voltage Switchgear System Guide

UHIR Series. Horizontal or Vertical Mounting Industrial / Commercial Electric Unit Heater. Owner s Manual

Unit 6: EXTRUSION. Difficult to form metals like stainless steels, nickel based alloys and high temperature metals can also be extruded.

LEVEL GAUGES WITH MAGNETIC JOINT L 14 - L 22 - L 34

Explosion proof enclosures

SIVACON Low Voltage Switchboard

Morgue refrigeration unit

High-Voltage Circuit-Breakers 3AP1/ kv up to 550 kv. Power Transmission and Distribution

TECHNICAL DATA & SERVICE MANUAL SPLIT SYSTEM AIR CONDITIONER INDOOR UNIT: AW52AL AW64AL AW52AL AW64AL /05

ABB s Disconnecting Circuit Breakers Higher substation availability and lower environmental impact

5SV Residual Current Protective Devices

TECHNICAL SPECIFICATION FOR HIGH TENSION LINE HARDWARE AND ACCESSORIES FOR ACSR PANTHER & WOLF CONDUCTOR

INFRARED RADIANT HEATERS. air heaters

Electrical Grounding. Appendix C

Bypass transfer switch mechanisms

SPECIFICATIONS FOR TENDER NO: PSNR/SCP/VKS/E 1635 ANNEXURE I TECHNICAL SPECIFICATIONS FOR LIGHTING HIGH MAST

8146/5 Series Breaker Panelboards

air water oil antifreeze grease diesel fuel kerosene oxygen-acetylene lpg-methane electricity Hose & cable reel

Position Transducers with Restoring Spring 10, 25, 50, 75, 100 mm TR, TRS Series

Electronic overload relay EF65, EF96 and EF146

Specification Guide. for RVAC. Direct Replacement. AC Medium Voltage. Circuit Breakers

Eaton Safety & Reliability Solutions in the Oil & Gas Industry Electrical

SUGGESTED SPECIFICATION for Series 185 Service Entrance Rated Automatic Transfer Switches

Glenair Military and Industrial Power and Signal Connectors

SECTION DRY-TYPE TRANSFORMERS

TECHNICAL SPECIFICATION FOR PROJECTION WELDING MACHINE (Qty. 2 Nos.)

TECHNICAL SPECIFICATIONS

e 2 ALPHA Medium Voltage Switchgear Data Sheet K EN

GE Power Controls. MiniFORM Switchboards

C ole s quality Open Frame Instrument Rotary Switch provides low

Emirates Aluminium starts up World s first fully integrated power distribution system from ABB

Series 8146/5-V37 and Series 8150/5-V37

EC DECLARATION OF CONFORMITY FOR MACHINES

English AUTOMATION SYSTEMS FOR SLIDING GATES. Operating and installation instructions SLIDE SERIES

High-speed folding doors. F Series

Automatic Fire Fighting Monitors

Grounding & Bonding Why it is done And How to Install Properly

CLAMPS CONNECTORS & EQUIPOTENTIAL RING

CRN5-5 A-FGJ-G-E-HQQE 3x230/400 50HZ

Transcription:

Name, department/event, date High Reliability with ABB Disconnector Slide 1

Disconnectors Critical Component of Substation Availability To be replaced by other photo This photo is not OK as showing unsafety working condition Slide 2

Disconnectors in a substation What is it? A mechanical switching device which provides, in the open position, an isolating distance in accordance with specified requirements (IEV 441-14-05) Slide 3

Why are disconnectors required? Historical and Present Perspective A Myth? Historically, bays were designed to make it possible to isolate the circuit breaker for maintenance The basis was that circuit breakers demanded more maintenance than disconnectors Typical maintenance intervals for earlier circuit breakers was 1-2 years and for disconnectors 4-5 years To avoid total outage of the busbar during disconnector maintenance a second busbar was used Slide 4

Disconnector Reliability with Minimum Maintenance Slide 5 Operates smoothly & consistently when command is given Consistent Main Circuit Resistance (mv drop) over life. Less losses. Short time current withstand capacity with some min. current carrying capability Minimum maintenance during Lifetime Good lubricating system Synthetic and dry lubrication Retains isolating properties Links do not get disturbed Permanent adjustments Good seismic withstand capability Constructional flexibility to suit various layouts & spaces in the S/S

Disconnectors Various Environments and Conditions Wide Range of Temp. Earthquake Area Ice Loads Sea Coast, Pollution Winds, storms and other external impacts Slide 6

Disconnectors Reality and Consequences Unable to carry rated current due to deterioration of current carrying path Unable to close or open (correctly) due to deterioration of linkages etc. Failure of interlocks due to auxiliary switch malfunction Failure of electrical circuits due to poor enclosure. Failure to withstand seismic forces. Mechanical failures when installed in special layouts Grid collapse Unable to (close) energize circuit. More downtime for maintenance Spare inventory Unsafe operation Unable to isolate (open) the circuit Severe threat to safety Loss of revenue Slide 7

ABB Disconnectors Global Product Portfolio SDF edb GW54 GW57 DSSP 72-550kV 72-420kV 123-550kV 245-550kV 123-245kV 4000A, 50kA 3150A, 50kA 5000A, 63kA 4000A, 63kA 4000A, 50kA Center Break Double Break Pantograph Horizontal Knee Semi-Pantograph Remarks: Higher rating upon request Slide 8

Horizontal Center-Break SDF Customer Benefits Reduce energy loss from Minimized contact resistance Minimum number of joints with special material High reliability from special design Special conducting material without external spring for contacts Strong rotary pedestals Dead center interlocking Superior design of mechanical interlock Easy and quick erection Smooth operation and minimal maintenance Suitable for wide range of environmental conditions Slide 9

Horizontal Center-Break SDF Structure Applied upto 550kV Each pole contains: A base frame with two rotary pedestals Two insulators Current path Earthing Switch: Both right and left side can be equipped with earthing switch Drive mechanism: Motor/manual-operated drive Slide 10

Horizontal Center-Break SDF Structure 1. Current path 2. Contact finger 3. Contact piece 4. Terminal plate 5. Rotary head 6. Insulator 7. Operating mechanism of disconnector 8. Diagonal rod 9. Base frame 10. Rotary pedestal 11. Coupling rod 12. Earthing contact 13. Earthing arm 14. Earthing contact finger 15. Operating mechanism of earthing switch 16. Earthing switch shaft 10 11 9 8 7 2 3 1 4 5 6 15 12 14 13 16 Slide 11

Horizontal Center-Break SDF Parameters Slide 12

Horizontal Center-Break SDF Rotary Terminal Head Current Transfer Joint Tulip type silver faced contact arrangement, protected from outdoor conditions Graphite and synthetic material bearings used for life long performance Permits 360 rotation of terminal Sliding surfaces locked and lubricated with dry lubricants (Delrin) Weather proof and high robustness Slide 13

Horizontal Center-Break SDF Contacts and Current Path Hot metalizing of Cu-Al joints to reduce galvanic voltage difference to avoid possible corrosion. No Separate springs No rusting/ corrosion No loose positions; minimum components & maintenance Consistent Contact resistance over long periods. Minimum number of joints for SDF with welded tubular sections These all contribute in maintaining the circuit resistance to the optimum level and consistency during the service life of disconnector. Reduce energy loss Slide 14

Horizontal Center-Break SDF Turn Tables Turn table bearings totally protected from environments (i.e. ingress of dust/water) Two stainless steel bearings (double bearings) for reliable rotary movement and reduced friction High temperature stable grease used for lubrication. Lifetime lubrication. Virtually no maintenance Slide 15

Horizontal Center-Break SDF Links Use of insulated rod end spherical stainless steel bearings, providing Protection to galvanic corrosion Three dimensional flexibility in movement Giving reduced friction through the life Not require any lubrication Alignment in 3D avoiding stresses on bearing Bearing after 10 years in field Slide 16

Horizontal Center-Break SDF Dead Center Locking DEAD CENTER POSITION 1 DEAD CENTER POSITION 2 CLOSED OPEN Slide 17

Horizontal Center-Break SDF Position Signal Closed Position (of a mechanical switching device) The position in which the predetermined continuity of the main circuit of the device is secured Open Position (of a mechanical switching device) The position in which the predetermined clearance between open contacts in the main circuit of the device is secured Clause 5.104.3 Indication and signaling of position Indication and signaling of the closed and open position shall not take place unless the movable contacts have reached their closed or open position, respectively and the first paragraph of 5.104.1 is fulfilled Slide 18 1 st paragraph of Clause 5.104.1: Disconnectors and earthing switches, including their operating mechanisms, shall be designed in such a way that they cannot come out of their open or closed position by gravity, wind pressure, vibrations, reasonable shocks or accidental touching of the connecting rods of their operating system

Horizontal Center-Break SDF Drive Mechanism Available for both motor drive and manual types All mounting nuts & bolts hare of non corrosive material Aux. Switches are suitable for SCADA applications and can be changed from NO to NC and vice-versa even at site Aluminium cabinet and powder coated with Polyurethane paints, giving lasting protection to corrosion Stainless steel door hinges does not allow door jamming even after many years In built safety mechanism safety release as standard feature main arms cannot rotate more than 90 degrees in manual or motorized mode Slide 19

Horizontal Center-Break SDF Contact Alignment and Base Adjustment Contact alignment is essential to avoid undue mechanical & thermal stress and create long term reliability Cylindrical form can provide the absolute rotational alignment No loose shim requirement for arm alignment Provide flexibility with simplicity Slide 20

Horizontal Center-Break SDF Modular Transport Assembly Slide 21

Horizontal Center-Break SDF Various Arrangements Slide 22

Horizontal Center-Break SDF Vertical Mounting Slide 23

Horizontal Center-Break SDF Integrated or Stand-Alone Earth Switch Slide 24

Horizontal Center-Break SDF Special Installation Slide 25

Horizontal Center-Break SDF Special Installation (Above) 245kV substation in Columbia; Gantry mounted at elevated height. Operating mechanism at working height (Left) 145kV substation in Bangladesh Slide 26

Horizontal Center-Break SDF Special Installation At 123kV level, Al Archa, Kyrgyzstan Disconnector with 3 drives on one phase Reliable operation in minimum ambient temperatures down to 40 deg.c Tandem Arrangement Slide 27

Horizontal Double-Break edb Customer Benefits Reduce energy loss from Minimized contact resistance Special profile for current path High reliability from special design Special conducting material without external spring for contacts Strong rotary pedestals Dead center interlocking Superior design of mechanical interlock Easy and quick erection Smooth operation and minimal maintenance Suitable for wide range of environmental conditions Slide 28

Horizontal Double-Break edb Structure Applied upto 420kV Each pole contains: A base frame with one rotary pedestal Three insulators Current path Earthing Switch: Both right and left side can be equipped with earthing switch Drive mechanism: Motor/manual-operated drive Slide 29

Horizontal Double-Break edb Structure 1. Current path 2. Contact finger 3. Fixed contact 4. Terminal plate 5. Operating rod 6. Insulator 7. Operating mechanism of disconnector 8. Base frame 9. Rotary pedestal 10. Operating rod of earthing switch 11. Earthing contact 12. Earthing arm 13. Earthing contact finger 14. Operating mechanism of earthing switch 15. Earthing switch shaft 2 8 1 9 7 5 3 4 6 13 12 8 14 10 11 15 Slide 30

Horizontal Double-Break edb Parameters Slide 31

Horizontal Double-Break edb Contacts and Current Path Hot metalizing of Cu-Al joints to reduce galvanic voltage difference to avoid possible corrosion. No Separate springs No rusting/ corrosion No loose positions; minimum components & maintenance Consistent Contact resistance over long periods. Special profile designed for the current path These all contribute in maintaining the circuit resistance to the optimum level and consistency during the service life of disconnector. Reduce energy loss Slide 32

Horizontal Double-Break edb Turn Tables Turn table bearings totally protected from environments (i.e. ingress of dust/water) Two stainless steel bearings (double bearings) for reliable rotary movement and reduced friction High temperature stable grease used for lubrication. Lifetime lubrication. Virtually no maintenance Slide 33

Horizontal Double-Break edb Links Use of insulated rod end spherical stainless steel bearings, providing Protection to galvanic corrosion Three dimensional flexibility in movement Giving reduced friction through the life Not require any lubrication Alignment in 3D avoiding stresses on bearing Bearing after 10 years in field Slide 34

Horizontal Double-Break edb Dead Center Locking DEAD CENTER POSITION 1 DEAD CENTER POSITION 2 CLOSED OPEN Slide 35 SDF picture but also applicable for edb

Horizontal Double-Break edb Position Signal Closed Position (of a mechanical switching device) The position in which the predetermined continuity of the main circuit of the device is secured Open Position (of a mechanical switching device) The position in which the predetermined clearance between open contacts in the main circuit of the device is secured Clause 5.104.3 Indication and signaling of position Indication and signaling of the closed and open position shall not take place unless the movable contacts have reached their closed or open position, respectively and the first paragraph of 5.104.1 is fulfilled SDF Picture but also applicable for edb Slide 36 1 st paragraph of Clause 5.104.1: Disconnectors and earthing switches, including their operating mechanisms, shall be designed in such a way that they cannot come out of their open or closed position by gravity, wind pressure, vibrations, reasonable shocks or accidental touching of the connecting rods of their operating system

Horizontal Double-Break edb Drive Mechanism Available for both motor drive and manual types All mounting nuts & bolts hare of non corrosive material Aux. Switches are suitable for SCADA applications and can be changed from NO to NC and vice-versa even at site Aluminium cabinet and powder coated with Polyurethane paints, giving lasting protection to corrosion Stainless steel door hinges does not allow door jamming even after many years In built safety mechanism safety release as standard feature main arms cannot rotate more than 90 degrees in manual or motorized mode Slide 37

Horizontal Double-Break edb Contact Alignment and Base Adjustment Contact alignment is essential to avoid undue mechanical & thermal stress and create long term reliability The current carrying conductors and rotary pedestals are designed for easy adjusting and alignment. No loose shim requirement for the alignment Provide flexibility with simplicity Slide 38

Horizontal Double-Break edb Various Arrangement Parallel Installation Series Installation Under hung On gantry etc.. Slide 39

Horizontal Double-Break edb Integrated or Stand-Alone Earth Switch Slide 40

Horizontal Double-Break edb 420kV edb at Adani Power at Mundra, India Slide 41

Pantograph GW54 Customer benefits Solid pantograph arms Four arms to provide rigid construction Parallel connection to lower circuit resistance Large open/close range to provide reliable on-position connection Large contacting area between fixed and moving contacts to provide excellent electricity conduct ability All joints are connected through rotating contacts, which has incomparable performance on reliability, sealing, conductivity and anti-corrosion Transmission parts are insulated from conducting parts by Nylon tubes The mechanism is housed in an aluminum enclosure, protecting it against ice and pollution Slide 42

Pantograph GW54 Structure Slide 43 Applied to 145/245/550kV S/S Each pole contains; A transmission mechanism One rotating insulator One supporting insulator Main Blade Four telescopic booms Silver plated copper contacts Earthing Switch: Can be equipped with one earthing switch Drive mechanism: Motor/manual-operated drive

Pantograph GW54 Structure 1. Base 2. Post insulator 3. Rotating insulator 4. Earth received contact 5. Pantograph 6. Fixed contact 7. Earthing switch 8. Vertical rod 9. Mechanism for main blade 10.Mechanism for earthing switch Slide 44

Pantograph GW54 Parameters Technical data GW54 Slide 45

Pantograph GW54 Arms and Contacts Each main blade includes: One mechanism Four pantograph arms Four moving contacts One fixed contacts Contacts are made of electrolytic copper and silver plated to prevent from oxidation and also provide high contact. By design, the contact pressure increases during short circuit. Prevent arcs and failure. Slide 46

Pantograph GW54 Arms and Contacts Solid pantograph arms: Stable double arms design with conductive bearing. Parallel connection to lower circuit resistance Mechanical and electrical separation: Mechanical transmission parts are insulated from conducting parts by Nylon tubes. Contacts: Electrolytic copper plated with silver Large electricity conductive area Maximum rated current is 5000 A Mechanism housed in an aluminum enclosure against pollution and ice Slide 47

Pantograph GW54 Driving System of Main Blade The pantograph mechanism is installed on the support insulator, and transfers the movement from the rotating insulator to the arms of the pantograph The springs that compensate the weight of the pantograph arms are also installed in this housing Each pantograph is equipped with four aluminum arms to ensure a rigid construction with a very high short circuit rating Slide 48

Pantograph GW54 Motion Transmission Slide 49

Pantograph GW54 Turning Conductive Bearing Tin-bronze bearing Fully sealed Contact resistance is only 9 mohm Tightly connected High hardness, no breaking off and no corrosion Good conductivity Slide 50

Pantograph GW54 Mechanism Function Motor Drive Manual Drive Interlock Local and Remote Control Large box to facilitate easy wiring, operation, maintenance Up to 32 auxiliary contacts can be provided Reliable Motor gears Maintenance free IP55 (higher IP on request) Slide 51

Pantograph GW54 245kV Disconnector Slide 52

Pantograph GW54 245kV Disconnector Slide 53

ABB Disconnector Robust and Reliable Offerings Strong Solution to System Availability Operates correctly consistently when command is given Gives consistent & less Main Circuit Resistance (mv drop) over lifetime Has good short time current withstand capacity Needs little Lubrication with permanent adjustments Strong seismic capability Provides adequate isolation during maintenance ABB Disconnector RELIABLE solution Saves Energy Time & Money! Slide 54