ASTM STANDARDS AND THE CANDLE INDUSTRY



Similar documents
Andrew Leach Innovation Manager (Project Manager) SC Johnson, Manufacturing Frimley Green, UK

Fire Testing of Recycled Materials for Building Applications

Home Product Testing

How To Test For Premer Retardant

EXPANDED POLYSTYRENE (EPS) INSULATION BOARD SPECIFICATIONS

Fire-Rated Glass and Glazing START

A H M 531 Penetration & Ring & Ball & Ductility & Flash & Fire point By: Mu'men Al-Otoom

OFM-TG Office of the Fire Marshal F M. Handling Flammable and Combustible Liquids in School Laboratories GUIDELINE

Convection TCO650. For your safety and continued enjoyment of this product, always read the instruction book carefully before using.

2010 edition. Handbook of. Fire-Rated Glass. for schools

Electronics and Soldering Notes

Know the Code: Using Spray Foam Insulation In Attics and Crawl Spaces

Gas-Fired, Residential Storage Type Water Heaters

THERMAL BARRIERS FOR THE SPRAY POLYURETHANE FOAM INDUSTRY

electric kettle owner's manual SAVE THIS USE AND CARE BOOK Please call with questions. MGD550

Bottom Loading Water Dispenser

Convection TCO600. For your safety and continued enjoyment of this product, always read the instruction book carefully before using.

Installation Instructions

Specifications, Product Testing and Terminology

Remember the best arguments are based on the strongest evidence and can explain why opposing arguments are incorrect.

Pyroguard Wired Glass

Treatment of a surface or structure to resist the passage of water in the absence of hydrostatic pressure. presence of hydrostatic pressure.

City of San Diego, CWP Guidelines

Sulfur Tail Gas Thermal Oxidizer Systems By Peter Pickard

EN Export Manager Pulastic Sports Surfaces The Netherlands

INTERNATIONAL STANDARD

CEEN Geotechnical Engineering Laboratory Session 7 - Direct Shear and Unconfined Compression Tests

Your safety and the safety of others are very important.

CERTIFICATE NAME OF PRODUCT MANUFACTURER PRODUCT DESCRIPTION CERTIFICATION PROCEDURE. No VTT C Date of issue , Updated July 1, 2011

Survival Laser SL-001BB Laser Parts Bundle Assembly & Operation Instructions

FIRE SAFETY ONLINE TRAINING

Apr 17, 2000 LAB MANUAL

Autoclave Safety. Autoclaves are sterilizers using high pressure and high temperature steam. The potential safety risks for the operators are:

Auditing Contract Manufacturing Processes

Meeting the Fire Code with Continuous Foam Plastic Insulation

ASTM E Building Perimeter Fire Summary of Papers that have been written on Fire Exposures that deal with High Rise Buildings and Vision Glass

Presented by: Rich Perry Marsh Risk Consulting

Standard Operating Procedure

Flammable and Combustible Liquids. Slide 1 (of 23)

Chemical Reactions Practice Test

NOTE: Additional user information for your printer may be available in the "Manuals" section at support.dell.com.

Hygro-Thermometer + InfraRed Thermometer Model RH101

Propane Conversion Kit PROPANE CONVERSION KIT INSTALLATION MANUAL

ADMINISTRATIVE SERVICES MANUAL

THERMAL INSULATION MATERIALS TEST METHOD SELECTION LIST

Dubai Municipality Standard DMS 1: Part 5: 2004

Fire-resistant barriers: background on requirements and determination method. Reading guide for test reports.

Underwriters Laboratories Testing Information

A TEST TO DETERMINE THE VIABILITY OF SELF-HEATING BEVERAGE CONTAINERS AS IGNITION SOURCES

The following document contains information on Cypress products.

Please read and keep these instructions. Run water through your machine before first use

Multiple Choice For questions 1-10, circle only one answer.

PLEASE READ ALL INSTRUCTIONS BEFORE USE AND SAVE A COPY FOR FUTURE REFERENCE!

Test Bank - Chapter 3 Multiple Choice

EUROPEAN STANDARDS PERSONAL PROTECTIVE CLOTHING FOR FLAME RESISTANT. Alexander Gstettner, Lenzing AG Austria

HARD SURFACE PAPERS INSTRUCTION GUIDE

AUTO COLLISION REPAIR CERTIFICATE I COURSE DESCRIPTIONS. Total: 18 Credit Hours

FIRE SAFETY FOR OFFICE WORKERS

ASK THE EXPERT: Burner Troubleshooting Information & Maintenance

Sash or Balance Replacement Guide

The Globally Harmonized System and OSHA Hazard Communication Revision

Guide Specification STAYFLEX CORROSION CONTROL AND THERMAL INSULATION SYSTEM

This document establishes MSHA s Standard Test Procedure (STP) for the Determining the Viscosity of a Hydraulic Fluid in Saybolt Universal Seconds.

GNOME PELLET E.I. Pellet Heater Owner's Manual Installation and Operating Instructions. Please read this entire manual before installation.

orlando OWNER S MANUAL

NIGHTWEAR AND FIRE. A Guide to Nightwear (Safety) Regulations. Contents

Approval Standard for Plastic Suspended Ceiling Panels

The Globally Harmonized System and OSHA Hazard Communication Revision

CYCLOTENE Advanced Electronics Resins (Photo BCB) Processing Procedures for 20µm Photo-BCB Layers Using XUS35078 type 3

SORTING PLASTICS FOR RECYCLING INTRODUCTION

OPERATING YOUR JEN-KEN GLASS KILN

HAZARDS AND THREATS WILDFIRES HOMEOWNERS CHECKLIST INSIDE THE HOME

3M HEAD PROTECTION. For more information, please visit HARD HATS 101 MANUAL

REPORT NUMBER: MID-001 ORIGINAL ISSUE DATE: JUNE 27, 2012

From Wired Glass to Clear Solutions: Designing with Fire Rated Glass Today

Sugar or Salt? Ionic and Covalent Bonds

In accordance with NFPA 30, these containers are not to store Class I flammable liquids.

MAP COFFEE MIA CAPSULE COFFEE MACHINE INSTRUCTION MANUAL MODEL: CM4725. Read this manual thoroughly before using and save it for future reference

Energy Content of Fuels

San josé OWNER S MANUAL

MATERIAL SAFETY DATA SHEET

Decoding Heat Cure Denture Base Polymers. By Tom Zaleske

Thank You... On behalf of the entire team at Thane Housewares, we appreciate your recent purchase

GigaCrete Specification PlasterMax

LESSON PLAN 1. Fire Science. Key Terms and Concepts. ash chemical reaction combustion Consumer Product Safety Commission endothermic exothermic

FLAMMABILITY REQUIREMENTS FOR AIRCRAFT SEAT CUSHIONS

American Fireglass Outdoor Fire pit kit information. General instructions/warnings for outdoor gas pan and burner systems

CONE CALORIMETER A TOOL FOR MEASURING HEAT RELEASE RATE

Selecting Energy Efficient New Windows in Florida

Requirements for Fire Protection of Light Weight Floor Systems **Act 1 Revisited**


Model 1756 Test Lead Kit

Daily use. Never use alcohol or other solvents to clean any part of the loudspeakers!

CAUTION RISK OF ELECTRIC SHOCK DO NOT OPEN

COMMERCIAL BUILDING APPLICATIONS

Balloon Inside a Bottle

SECTION ALUMINUM FRAMED ENTRANCES and STOREFRONTS. System 402 Flush-Glazed Screw Spline Storefront

Reducing Injury and Damage Related to Electric Dryer Fires. Fire Containment Tests for the Second Edition of UL 2158

Oxy-Fuel Gas Welding. Given a functional oxy-fuel gas unit, instruction and demonstration of use, each student will be able to:

Transcription:

ASTM STANDARDS AND THE CANDLE INDUSTRY 3 rd World Candle Congress Disney World Orlando Florida July 7, 2010 Workshop Presenters Jim Becker Candle Solutions And Bob Moss SEA Ltd.

WHAT IS ASTM? ASTM International is one of the largest voluntary standards development organizations in the world-a trusted source for technical standards for materials, products, systems, and services. Known for their high technical quality and market relevancy, ASTM International standards have an important role in the information infrastructure that guides design, manufacturing and trade in the global economy.

WHAT IS THE PROCESS OF STANDARD DEVELOPMENT? Stake holders and interested parties including manufacturers, retailers, suppliers, testing laboratories and representatives from the US Consumer Products Safety Commission (CPSC) discuss test parameters, methodologies, procedures, terminology, requirements, and more to develop consensus standards.

WHAT ARE THE STANDARDS THAT AFFECT THE CANDLE INDUSTRY? F 1972-05 STANDARD GUIDE FOR TERMINOLOGY RELATING TO CANDLES AND ASSOCIATED ACCESSORIES F 2058-07 STANDARD SPECIFICATION FOR CANDLE FIRE SAFETY LABELING F 2179-02 (REAPPROVED 2007) SPECIFICATIONS FOR ANNEALED SODA-LIME SILICATE GLASS CONTAINERS THAT ARE PRODUCED FOR USE AS CANDLE CONTAINERS F 2326-04 (REAPPROVED 2009) STANDARD SPECIFICATION FOR COLLECTION AND ANALYSIS OF VISIBLE EMISSIONS FROM CANDLES AS THEY BURN F 2417-09 STANDARD SPECIFICATION FOR FIRE SAFETY FOR CANDLES F 2601-09 STANDARD SPECIFICATION FOR FIRE SAFETY FOR CANDLE ACCESSORIES

ARE THE STANDARDS MANDATORY? ALL STANDARDS ARE VOLUNTARY AT THIS TIME THERE IS A PETITION (submitted by NASFM) TO THE CPSC TO MAKE THE STANDARDS MANDATORY WHAT DOES IT MEAN TO BE A VOLUNTARY STANDARD? VOLUNTARY MEANS IT IS UP TO YOU TO FOLLOW THE STANDARDS OR NOT, NOT, HOWEVER IF ONE OF YOUR CANDLES FAILS AND CAUSES PROPERTY DAMAGE OR INJURY, THE LAWYERS WILL CITE THESE STANDARDS AS THOUGH THEY ARE MANDATORY, THEREFORE IT IS IMPERATIVE THAT YOU BECOME FAMILIAR WITH AND FOLLOW THE REQUIREMENTS OF THESE STANDARDS

F 1972-05 STANDARD GUIDE FOR TERMINOLOGY RELATING TO CANDLES AND ASSOCIATED ACCESSORIES No Specific requirements for F1972-05. This standard provides the working terminology so that everyone using the standards uses the same terms and definitions. These are terms that will appear in subsequent candle standards that the reader - user should become familiar with. If you do not have a copy of this standard one can be purchased through ASTM for about $35. You can order on line at www.astm.org

WHAT ARE THE REQUIREMENTS OF EACH STANDARD?

F 2058-07 STANDARD SPECIFICATION FOR CANDLE FIRE SAFETY LABELING WARNING STATEMENT WORDING (OR EQUIVALENT) BURN WITHIN SIGHT KEEP AWAY FROM THINGS THAT BURN KEEP AWAY FROM CHILDREN NEW PLACEMENT REQUIREMENTS FOR CANDLES WITH PACKAGING MUST BE PLACED ON THE TOP OR SIDES OF THE PACKAGE IF THE WARNING IS PUT ON THE BOTTOM OF THE PACKAGE, THE WORDS SEE BOTTOM PANEL FOR SAFETY INFORMATION MUST APPEAR ON THE TOP OR SIDE OF THE PACKAGE NEW PICTOGRAM OPTIONS

F 2058-07 STANDARD SPECIFICATION FOR CANDLE FIRE SAFETY LABELING PICTOGRAMS CANNOT BE USED WITHOUT TEXT LABELS MUST BE VISIBLE TO THE CONSUMER AT THE POINT OF SALE FREESTANDING AND FILLED CANDLES (EXCLUDING TEALIGHTS) FIRE SAFETY WARNING MUST APPEAR ON THE TOP, BOTTOM OR SIDES OF THE CANDLE AS WELL AS ON THE PACKAGING SMALL CANDLES WITH LESS THAN 21 CM³ (SUCH AS VOTIVES) CAN USE WARNING STATEMENT BURN WITHIN SIGHT WITH THE SAFETY ALERT SYMBOL

F 2058-07 STANDARD SPECIFICATION FOR CANDLE FIRE SAFETY LABELING

F 2179-02 (REAPPROVED 2007) SPECIFICATIONS FOR ANNEALED SODA-LIME SILICATE GLASS CONTAINERS THAT ARE PRODUCED FOR USE AS CANDLE CONTAINERS Thermal shock resistance requirements Containers must survive a thermal shock with a 90 F differential between the hot and cold water baths. Containers exposed to hot water bath for 5 minutes, 15 second transfer time and then 30 seconds in cool water bath. Typical bath temperatures are 160 F for hot water bath and 70 F for cool water bath.

F 2179-02 (REAPPROVED 2007) SPECIFICATIONS FOR ANNEALED SODA-LIME SILICATE GLASS CONTAINERS THAT ARE PRODUCED FOR USE AS CANDLE CONTAINERS Annealing requirements Polariscope method containers examined using crossed polarized light to look at residual strain in the glass. Glass is evaluated to determine apparent and real temper. To meet the specification the real temper must be 4 or less. Real temper = Apparent temper / (T/0.160) where T = the thickness of the container

REFERENCED ASTM STANDARDS FOR ASTM F2179 ASTM C 149 TEST METHODS FOR THERMAL SHOCK RESISTANCE OF GLASS CONTAINERS ASTM C 148 TEST METHODS FOR POLARISCOPE EXAMINATION OF GLASS CONTAINERS ASTM C 224 PRACTICE FOR SAMPLING GLASS CONTAINERS

Thermal Shock Testing Libbey Glass

Thermal Shock Testing

Polariscope and Annealing

Polariscope and Annealing

Polariscope and Annealing

Polariscope and Annealing

F 2179-02 (REAPPROVED 2007) SPECIFICATIONS FOR ANNEALED SODA-LIME SILICATE GLASS CONTAINERS THAT ARE PRODUCED FOR USE AS CANDLE CONTAINERS Annealing requirements Scribe test method containers bottoms are scribed or sanded around the knuckle at the base with an X scribed in the bottom. Containers are filled with room temperature water and allowed to stand for 15 minutes. Containers are emptied and examined for cracks and breakage.

F 2417-09 STANDARD SPECIFICATION FOR FIRE SAFETY FOR CANDLES Burn Test parameters: Candles burned in 4-hour burn cycles until end of useful life except tea lights and gel candles Wicks to be trimmed to manufacturer s label instructions Burned in laboratory with minimum draft Laboratory temperatures between 68 F to 86 F Candles spaced a minimum of 20 cm apart Flame heights observed at periodic intervals and recorded at the end of each burn cycle

F 2417-09 STANDARD SPECIFICATION FOR FIRE SAFETY FOR CANDLES Maximum Flame height requirement UP TO 3 INCHES (MOST CANDLES) UP TO 3.75 INCHES (CERTAIN RELIGIOUS CANDLES) Candles intended to be burned outside are exempt No secondary ignition No container failures For pillar candles no flame impingement of flame on the supporting surface at end of life

Flame Height Measurement

Flame Height Measurement

Flame Height Measurement Novelty Candle

Secondary Ignition Example Carbon Balls and Glass Failure

Secondary Ignition Example Flash Over

Secondary Ignition Flammable Coating

Container Failure

F 2417-09 STANDARD SPECIFICATION FOR FIRE SAFETY FOR CANDLES STABILITY Initially candles must remain stable when tilted to 10 off level Tilt stability of candles while in test BURNING CANDLE SHALL NOT TIP OVER DURING BURN TESTING WHICH APPLIES TO FREESTANDING CANDLES ONLY

Test For Stability

F 2417-09 STANDARD SPECIFICATION FOR FIRE SAFETY FOR CANDLES PLASTIC TEALIGHT CUP FLAMMABILITY 10 CUPS ARE TESTED FOR FLAMMABILITY ON THEIR SIDES BUTANE FLAME APPLIED TWICE TO EACH CUP FOR 10 SECONDS EACH APPLICATION MEASURE THE CUMULATIVE AMOUNT OF TIME OF COMBUSTION AFTER EACH APPLICATION FOR ALL 10 CUPS TOTAL CUMULATIVE TIME CANNOT EXCEED 300 SECONDS NO SINGLE TEST BURN CAN EXCEED 30 SECONDS NO TEST SPECIMEN CAN BE COMPLETELY CONSUMED BY THE FLAME

Plastic Tealight Cup Flammability Test

F 2417-09 STANDARD SPECIFICATION FOR FIRE SAFETY FOR CANDLES Gel appendix guidance for gel candle manufactures ADDED FLASH POINT GUIDELINES FOR RAW MATERIALS AND FINAL FORMULATION MINERAL OIL MINIMUM 395º F FRAGRANCE MINIMUM 180º F FINISHED CANDLE FORMULATION - 375ºF RECOMMENDS EXTENSIVE TESTING BE DONE RECOMMENDS WORKING CLOSELY WITH RAW MATERIAL SUPPLIERS

F 2601-09 STANDARD SPECIFICATION FOR FIRE SAFETY FOR CANDLE ACCESSORIES RING FLAMMABILITY REQUIREMENTS TEST TRIPLICATE SAMPLES OF EACH MATERIAL ON THE CANDLE RING FLAME APPLIED FOR UP TO 60 SEC. AVERAGE COMBUSTION TIME FOR THE THREE TESTS CANNOT EXCEED 30 SEC. WITH NO ONE TEST SAMPLE BURNING MORE THAN 60 SEC.

Trim Ring Flammability Test

F 2601-09 STANDARD SPECIFICATION FOR FIRE SAFETY FOR CANDLE ACCESSORIES CANDLE HOLDER REQUIREMENTS FLAMMABILITY REQUIREMENTS FOR ALL CANDLE HOLDERS TRIPLICATE SAMPLES OF EACH MATERIAL IN THE HOLDER TESTED FLAME APPLIED FOR UP TO 60 SEC. AVERAGE COMBUSTION TIME FOR THE THREE TESTS CANNOT EXCEED 30 SEC. WITH NO ONE TEST SAMPLE BURNING MORE THAN 60 SEC.

Candleholder Flammability Test

F 2601-09 STANDARD SPECIFICATION FOR FIRE SAFETY FOR CANDLE ACCESSORIES CANDLE BURNER REQUIREMENTS THREE IDENTICAL SAMPLES BURNED EIGHT TIMES EACH NO EXCESSIVE FLAME HEIGHTS, SECONDARY IGNITION OR END OF USEFUL LIFE PROBLEMS AS DEFINED IN F 2417 BURNERS SHALL BE TESTED WITH A SCENTED TEALIGHT OR OTHER SPECIFIED OR SUPPLIED CANDLE POTPOURRI BURNERS SHALL BE BURNED WITH THE SPECIFIED MATERIAL OR SCENTED WAX IF NO MATERIALS ARE SPECIFIED

Candle Potpourri Burner Set- Up

Candle Potpourri Burner Test

Candle Burner Test

F 2601-09 STANDARD SPECIFICATION FOR FIRE SAFETY FOR CANDLE ACCESSORIES STABILITY WARNING IF THE ACCESSORY IS INTENDED TO BE USED WITH A CANDLE OTHER THAN THOSE SPECIFIED IN THE STANDARD, A WARNING MUST BE INCLUDED WARNING: TO PREVENT FIRES DUE TO TIPOVER, DO NOT USE A CANDLE GREATER THAN X INCHES TALL

Candle Accessory Tilt Test

F 2326-04 (REAPPROVED 2009) STANDARD SPECIFICATION FOR COLLECTION AND ANALYSIS OF VISIBLE EMISSIONS FROM CANDLES AS THEY BURN Same burn requirements as ASTM F2417 Candles burned in 4-hour burn cycles except tea lights and gel candles Wicks to be trimmed to manufacturer s label instructions Burned in laboratory with minimum draft Laboratory temperatures between 68 F to 86 F Candles spaced a minimum of 20 cm apart

F 2326-04 (REAPPROVED 2009) STANDARD SPECIFICATION FOR COLLECTION AND ANALYSIS OF VISIBLE EMISSIONS FROM CANDLES AS THEY BURN Candle allowed to burn for 15 minutes to develop a wax pool and a stable flame. Glass slide positioned 4 inches (10 cm) above the wax pool. Candles burned for 4 burn cycles (total burn time typically 16 hours). Glass slides evaluated using an optical densitometer for opacity. Method does not have a pass/fail criteria does provide a numerical indicator for the concentration of smoke collected on the slide. Method intended for manufactures in wick selection. Method developed when the market had predominately single wick candles. Method is good for dark smoke does not work well for white smoke produced by some vegetable wax candles.

Set up For ASTM F2326

Harvesting the Slide

Verifying Calibration of the Densitometer

Measuring Visible Emissions With Densitometer

Special Thank You to Rob Harrington of Blyth for the information and pictograms for candle labeling Libbey Glass for their assistance with the thermal shock video SEA Candle Technicians for setting up and filming demos SEA Video department for editing film for demos

Contact Information Jim Becker Candle Solutions 734 Riva Ridge Trail Corbin, KY 40701 606-523-0994 candlesoltns02@newwavecomm.net Robert Moss SEA, Ltd. 7349 Worthington- Galena Road Columbus, Ohio 43085 614-888-4160 Rmoss@sealimited.com