Noise Control Solutions for Floors, Walls, Ceilings, and Structures

Similar documents
Noise Control Solutions for Floors, Walls, Ceilings, and Structures

Controlling the Transmission of Impact Sound through Floors

Lightweight Partition Design for Residential and Commercial Buildings

Fire & Soundproofing Insulation. Roxul SAFE N SOUND. Fire and Soundproofing Insulation for Interior Partition Walls and Floors.

INTER-NOISE DECEMBER 2006 HONOLULU, HAWAII, USA

fire & soundproofing Insulation Roxul Safe n Sound Fire and Soundproofing Insulation for Interior Partition Walls and Floors

HOME THEATER. Noise Isolation, Soundproofing & Accessories

RESIDENTIAL PLUMBING ALTERATIONS PERMIT REQUIREMENTS

Built to Last. Built for Beauty. Good. Solid. Logix. TM

H-Stud Area Separation Wall System

CONSTRUCTION DETAILS & LOAD DESIGN CHARTS

Additions and Alterations

Fire Protection. CANADIAN STEEL CONSTRUCTION COUNCIL 201 Consumers Road, Suite 300 Willowdale, Ontario, M2J 4G8. Floor Assembly No.

Color logos Reverse logos Acoustics Black only logos

first look at GigaCrete s revolutionary new New Construction GigaHouse GigaHouse Utilizing GigaPanel

ENVIRONMENTAL INFORMATION APR 1200 products are made from glass mineral wool, one of the most environmentally friendly insulants available.

Mass Loaded Vinyl A review of the performance and cost in acoustical applications

The Case for Cross Laminated Timber: Part 2

The better way to build TM. Installation Manual. FOUNDATION SIPs & FROST WALLS SIPs

VOLUME V GUIDELINES FOR DESIGN CONSULTANT TABLE OF CONTENTS APPENDIX B: MASTER CONSTRUCTION SPECIFICATIONS AND PREPARATION GUIDE, DIVISIONS 0-10

Cement Board Exterior Applications Guide

2.18 INTERIOR & EXTERIOR FINISHES VAPOR & AIR BARRIERS

WASHROOM UPGRADE SIR CHARLES TUPPER BUILDING 2250 RIVERSIDE DRIVE, OTTAWA, ON SIR CHARLES TUPPER BUILDING A0.0 COVER SHEET / DRAWING LIST

R-Value and Densities Chart

Schluter -KERDI-BOARD Substrate, building panel, bonded waterproofing

Gypsum Board Systems Manual

Knauf Aquapanel Interior. Tile Backing. Cement board for wet areas. Will not deteriorate in water. Easy to score and snap

The Role of Acoustics in Curtain Wall Design:

Underwriters Laboratories Testing Information

Rockwool Flexi Insulation Application Guide

Whitley Manufacturing Co., Inc. 201 W. First Street S. Whitley, IN Phone (260) Sales Fax (260)

Envelope INSULATION BATT (2) Avoid Using Batt Insulation With Metal Framing. Pressure or Friction Fit

Fire Protective Options for I-Joist Floor Systems CONSTRUCTION GUIDE

Installation Guide. Bath and Wall Surrounds SERIES B

GYPSUM BOARD, GYPSUM PANEL PRODUCTS AND PLASTER

Point Auditorium Design Narrative PROJECT NAME: Point Auditorium DATE: 06/25/15 TO: Lance Francis FROM: Leslie Ellsworth

PART 1 GENERAL 1.1 SECTION INCLUDES

The better way to build TM. Installation Manual. EXTERIOR WALL SIPs

Section 4.3. Separating Floors. Timber frame floor with I-Beams. Upgrading existing timber floor with new ceiling. Timber frame floor with

Renovating Your Basement

Fiberglas, Exterior Wall Thermal Insulation

How To Repair A Boat Landing Deck With A Boat Bed

B. Related categories: The following categories contain requirements that relate to this section:

Building Construction. Structural Systems 1. Load-bearing wall construction 2. Skeleton framing 3. Combination of the two

SECTION PIPE HANGERS AND SUPPORTS

If you are a web registered user of ArlingontPermits.com you may also request an inspection at:

TECHNICAL ASSESSMENT:

Design No. P736 September 26, Restrained Assembly Ratings 1, 1-1/2 or 2 Hr. (See Items 3, 7 and 8A)

CertainTeed. Shaftliner For A rea Separation Firewalls

GYPSUM AREA SEPARATION FIREWALLS GA

Wood-frame Construction, Fire Resistance and Sound Transmission

NCMA TEK CONCRETE MASONRY FOUNDATION WALL DETAILS. TEK 5-3A Details (2003)

LITITZ MUTUAL INSURANCE COMPANY 2 North Broad Street Lititz, Pennsylvania - MAIN OFFICE -

Facility Summary. Facility Condition Summary. Seattle School District David T. Denny International Infrastructure. Facility Components

SAMPLE SCHEDULE OF VALUES APPLICATION & CERTIFICATE FOR PAYMENT

SOUND INSULATION FOR EXTERIOR WALLS AND FACADE SYSTEMS

PANELIZED HOME INSTALLATION GUIDELINE

This handout is a guide only and does not contain all of the requirements of the Minnesota State Building Code or city ordinances.

Chapter 6 ROOF-CEILING SYSTEMS

Acoustic performance of dwellings and specifics for lightweight constructions Professor Eddy Gerretsen

GYPSUM BOARD AND PLASTER

Building Envelope Design by Roxul (BEDR ) FireWall and Roxul Plus MB. Fire Rated Board Insulation for Pre-Engineered Metal Buildings

MOLD AND MOISTURE RESISTANT PAPERLESS SOLUTIONS FOR AREA SEPARATION WALLS

BUILDING ASSESSMENT QUESTIONNAIRE. B. TENANTS Is there more than one tenant in the building? YES

Fig. 2 WALL-TO-WALL PANEL CONNECTIONS CORNER WALL CONNECTION

EcoTouch Insulation with PureFiber Technology

AUTHORIZATION TO MARK

THE WAVERLY RENOVATION PROJECT

INC Flexi-Sorb. Versatile Flexible Easy To Install Durable Good Noise Reduction Economical. Typical Applications

ASTM E 90: Laboratory Measurement of Airborne Sound Transmission of Building Partitions and Elements

Composite Panel Firewall Systems

RESIDENTIAL ROOFING & RE-ROOFING, ROOF VENTILATION AND ROOF SHEATHING REQUIREMENTS MICHIGAN RESIDENTIAL CODE 2000

Engineered Wood Foundations

VA25014B0516 VA CINCINNATI PROJECT NO INPATIENT BED TOWER ADDITION (4 TH AND 5 TH FLOORS) SECTION GYPSUM BOARD

Building Envelope Design using ROXUL. FIREWALL and ROXUL PLUS MB. Fire Rated Board Insulation for Pre-Engineered Metal Buildings

Mark Cramer Inspection Services, Inc.

Sub-Bid Contractor Update Statement. Tab A - Invitation for Bids. Tab B - Instructions to Bidders

CHAPTER 7: Building Systems ROOFING SYSTEMS

sound reduction systems for commercial, educational and industrial environments

necessary for years of satisfactory service. SmartBlock insulating form concrete walls share the

Schlüter -KERDI-BOARD Substrate, structural panel, bonded waterproofing

STAYFLEX CORROSION CONTROL AND THERMAL INSULATION SYSTEM

Comprehensive information on fire-rated assemblies incorporating USG products and systems. Fire-Resistant. Assemblies

Installation Details. D1 General D2 Walls D3 Ceilings D4 Reference. D Installation Details

Technical Data wedi Subliner Dry Waterproofing Shower and Wet Area System

DEFAULT HEAT LOSS COEFFICIENTS

Insulation R-Value Comparisons

TABLE OF CONTENTS. Roof Decks 172 B, BA, BV Deck N, NA Deck. Form Decks FD,.6 FDV Deck 1.0 FD, 1.0 FDV Deck 1.5 FD Deck 2.0 FD Deck 3.

CertainTeed. GlasRoc Tile Backer

DIVISION 00 - PROCUREMENT AND CONTRACTING REQUIREMENTS

Schluter -Shower System Installation Handbook Bonded Waterproofing System for Tiled Showers, Steam Showers, Steam Rooms, and Bathtub Surrounds

DIVISION: WOOD, PLASTICS AND COMPOSITES SECTION: SHOP APPLIED WOOD COATINGS SECTION: SHEATHING REPORT HOLDER:

Building Department John Fiedler Construction Official Ext SAMPLE GUIDE FOR 1&2 FAMILY DWELLING BASEMENTS Rev

Improving the flood resistance of your home. Advice sheet 6: Flood-resilient floors

Multi-layer Insulation Blanket for Roofs

FIRE-RESISTANCE RATINGS WITH STEEL JOISTS

ULTIMATE GUIDE BE PREPARED FOR YOUR UPCOMING PROJECT

HOW TO INSULATE A CRAWLSPACE

RACQUETBALL, HANDBALL OR SQUASH COURTS AND GYMNASIUM WALL SURFACES

MRI RF SHIELDING DESIGN

Transcription:

Noise Control Solutions for Floors, Walls, Ceilings, and Structures

IsoMax Resilient Sound Isolation Wall and Ceiling Clip Effective sound control at low installed cost Error free installation of standard drywall furring channel Low-profile design; maximizes available occupied space Best performance for the fewest dollars spent to build noise control ceilings and walls Exclusive UL design L583 offers 1-hour fire rating for typical wood-framed ceiling composites 2x4 Wood Stud Fiberglass Insulation IsoMax Clips 7/8" Drywall Furring Channel 2x4 Wood Stud Fiberglass Insulation IsoMax Clips 7/8" Drywall Furring Channel 57 64 Hardwood Floor with 1/8" Pad Gypsum Concrete 3/4" Plywood 14" I-Joist 6" Fiberglass Insulation IsoMax Clips 7/8" Drywall Furring Channel 2x4 Wood Stud 54 33 57 (UL Design 583) Existing Wall 1-5/8" x 3-5/8" Steel Stud Fiberglass Insulation IsoMax Clips 7/8" Drywall Furring Channel 2x4 Wood Stud IsoMax Clips 1-1/2" Drywall Furring Channel Fiberglass Insulation 52 Wall Retrofit

CERAMIC TILE 61 56 ESR-3207 WAVE Hanger Worldwide Patents Pending Quick and Easy Wood-Framed Installations Don t design mixed use or multi-family projects without WAVE Hanger! Outperforms resilient channel and sound clips Highest performance-to-cost value for wood-framed floor/ceilings Fast and simple - No more pinching furring channel into clips! 7.88 in (200 mm) Fasteners Included 1.5 in (38 mm) Under Design Load ISPL Improvement vs. Resilient Channel ISPL Improvement (db) 16 14 12 10 8 6 4 2 WAVE ISPL Improvement above RC Deluxe Ceramic Tile 0 125 250 500 1000 2000 4000 WAVE Hanger 0.44 in (11 mm) Under Design Load 7/8" Drywall Furring Channel Frequency (Hz)

Concrete and Wood-Framed Ceiling Isolation Systems ICC: Deck-Suspended Ceiling Hanger Maximum natural frequency of 4.4 Hz under lightest typical load conditions Multiple features incorporated into the design ensure inexpensive installation; eliminates tying wire Spring/neoprene cup combination improves performance against low-frequency noise Contact your local sales rep for wire-tie and other hanger options IsoGrid: Quick-Connect Ceiling Hanger Dramatic labor savings over conventional ceiling hangers Meet code requirements while maximizing ceiling height Various attachment methods allow for installation on a variety of ceiling structures Known deflection rates ensure performance under design loads 4" Concrete Slab 1/2" Plywood 2" RIM-Q-2-16 ICC Isolation Hanger Cold Rolled Channel (CRC) Drywall Furring Channel 3-1/2" Fiberglass Insulation 94 82 ICC Isolation Hanger Cold Rolled Channel (CRC) Drywall Furring Channel 3-1/2" Fiberglass Insulation 84 70 KSCH Ceiling Hanger Rock Wool Batts Cold Rolled Channel (CRC) Drywall Furring Channel 72 51 IsoGrid Ceiling Hanger 6" Airspace Filled w/ Insulation Cold Rolled Channel (CRC) Drywall Furring Channel 50 THE ULTIMATE SOLUTION KSCH: Super-Compact Ceiling Hanger Patent No. 7,028,432 Low 3-1/2" airspace using 7/8" drywall furring channel at 1/2" nominal spring deflection; Multiple mounting options Meets building code for / 50 in smallest possible space

5/16" Parquet Flooring 5/8" Plywood 2 x 10 Joists ICW Ceiling Hanger Cold Rolled Channel (CRC) Drywall Furring Channel 3-1/2" Fiberglass Insulation 59 52 (UL Design 581) Hardwood Floor Over Vapor Barrier Mat 1-1/4" AccuCrete Slab 3/8" AccuQuiet Underlayment 3/4" Plywood 2 Layers Existing 1" x 6" Wood Subfloor 2x10 Joists 16" OC ICW Ceiling Hanger 6" Fiberglass Insulation Cold Rolled Channel (CRC) Drywall Furring Channel F 57 3/8" Wood Floor 1-1/2" Concrete Slab 3/4" Plywood 2 x 10 Joists ICW Ceiling Hanger Cold Rolled Channel (CRC) Drywall Furring Channel 3-1/2" Fiberglass Insulation 76 62 (UL Design 581) 62 (UL Design 581) ICW: Wood-Framed Ceiling Hanger Exclusive UL design L581 offers 1-hour fire rating for typical wood-framed ceiling composites Maxium natural frequency of 4.4Hz under lightest typical loads Actual installed load can vary between 75% and 150% of rated load without significant impact to ceiling performance Superior noise control for wood-framed construction without floor underlayment Ideal solution for new-build and renovations

Concrete Floating Floor Systems 2" Topping Slab Precast Concrete 14" Tee 54 24 4" Concrete Slab 1/2" Plywood 2" RIM L-2-12 2" Topping Slab Precast Concrete 14" Tee 73 70 4" Concrete Structural Floor 6" Concrete Structural Floor 49 53 25 27 NNIC* 62 54 3" Lightweight Concrete (polished) 1/2" Plywood 2" RIM L-2-16 3-1/2" Wood Deck Subfloor Steel Beam and Glue Lam Joist Support No Ceiling LOFT FIELD TEST 4" Concrete Slab 1/2" Plywood 2" RIM-Q-2-16 72 62 4" Concrete Slab 1/2" Plywood 2" RIM-Q-2-16 ICC Isolation Hanger Cold Rolled Channel (CRC) Drywall Furring Channel 3-1/2" Fiberglass Insulation 94 82 THE ULTIMATE SOLUTION *Normalized Noise Isolation Class, field test for airborne noise reduction RIM: Roll-Out Isolation Mat System Design for any load range Easy to create 1", 2", 3", and 4" airspaces Fast, simple, inexpensive installation Installation and supervision available RIM System successfully installed for over 45 years Natural Frequency constant over a wide load range Slab cast-in-place with no lifting required; trades back on the job as soon as concrete cures

Wood Flooring 4" Concrete Slab LSM Isolator 2" Air Space, Vented 6" Structural Slab 72 4" Reinforced Concrete Slab FLM Isolator w/ Neoprene Pad 2" Air Space 6" Structural Slab 4" Reinforced Concrete Slab FLM Isolator w/ Model KIP Pad 2" Air Space 6" Structural Slab 4" Reinforced Concrete Slab FLM Isolator w/ Neoprene Pad 4" Air Space 6" Structural Slab 69 69 71 61 Which is better? Ask for full report. 61 KSSM: Spring Formwork Isolation System Optimal placement of isolation system across low capacity structural floor designs Pre-loaded assemblies eliminate long wait to lift concrete slab Coordinate design directly with Alara-Lukagro at SD/DD Phase LSM: Spring Lift Slab Concrete Floating Floor System Fabricated, non-cast isolator housings permit flexible product and system design that maximizes application opportunities for any slab thickness, air cavity, and/or load options LSM natural frequency of 3.13 Hz for 1" rated deflection springs. Other rated deflection springs available FLM: Neoprene/KIP Lift Slab Concrete Floating Floor System Various load capacities offered in either fiberglass or neoprene isolators Easy to adapt for wide range of air spaces Standard mounts available for 4" thick concrete slabs Low-cost adapters available for thicker concrete slabs

Low Profile Floating Floors and Continuous Underlayent Systems RIM: Roll-out Isolation Material Highest Performance for Demanding Applications Ideal for dance studios, loft style condominiums, music practice rooms, and other applications requiring high performance noise control. Surpasses performance of continuous underlayments due to the airspace and lower natural frequency created by KIP isolators. Soundmatt: Low Profile for All Finish Floor Types 1" Oak Hardwood Floor 3" Subfloor Low cost continuous floor underlayment Low-profile underlayment for wood, tile, and carpet Fast, easy installation - no bonding required 45 3/8" Plywood 2 Layers 3/4" Plywood 2" RIM-I-2-16 6" Concrete Slab 66 Add between 2 Layers 3/4" Plywood 71 64 60 53 Ceramic Tile 1/2" Wonderboard 5/16" Soundmatt 15 F 50 3/4" Oak Hardwood Floor 3/4" Sleepers 1-1/2" Gypsum Concrete 2 Layers 1/2" OSB 1" RIM-L-1-16 1" Oak Hardwood Floor 3" Subfloor Economical and Effective Vinyl Floor Covering 1" Gypsum Concrete 5/16" Soundmatt 3/4" Oriented Stand Board (OSB) 18" I-Joist 3" Mineral Fiber Batts Resilient Channel 51 without Soundmatt 33 +18

ISOLayment QT: Lowest Profile for Wood Floors and Ceramic Tile Low-cost, recycled rubber noise control underlayment Extensively tested at the top labs in the USA Two (2) Styles: Flat (F) and Bumpy (B) in full rolls Engineered Wood IsoLayment QT-F 4" Concrete Hambro 500D System 1 Layer 1/2" GWB on furring channel Ceramic Tile IsoLayment QT-F 8" PT Slab 54 51 59 SR Floorboard: Sound Rated Floor System Withstands live loads up to 1000 psf Cuts easily using standard construciton knife Floor composites with finished tile flooring can be under two-inches (2") high Ceramic Tile 7/16" Glass Mesh Mortar Unit/Bond Coat 5/8" SR Floorboard 8" Flexicore Precast Subfloor 5/8" Hardwood Floor 3/4" Plywood Subfloor 5/8" SR Floorboard 7" Concrete Slab 59 59 +38 54 Ultra Quiet SR Floorboard: High Performance Sound Rated Floor System Same features as SR Floorboard with higher performance capabilities High resilience and sound absorption in a single layer Hardwood Floor with 1/8" Pad 1-1/4" Gypsum Concrete 1" Ultra Quiet SR Floorboard 3/4" Plywood 14" I-Joist 6" Fiberglass Insulation Resilient Channel No Resilient Channel 54 53 59 51 Approved for use with gypsum concrete, standard concrete, and built-up wood floors

Wall Isolation Wallmat: Resilient Partition Isolation Pad Easy to install pre-cut strips Field cut to length with a utility knife Continuous resilient support of the partition Engineered for a wide range of studwall loads Use for both top and bottom plate installation IsoBacker: Acoustical Fire Rated Outlet Backer Pad Underwriters Laboratories classified Maintains acoustical ratings per ASTM C 919 and ASTM E 497 Testing to UL 2 (ASTM E119) and UL 1479 (ASTM E814) Outstanding adhesion to outlet boxes and other substrates UL listed for metallic and non-metallic outlet boxes Pipe/Duct Lagging Barrier Model KNM-100ALQ PSB and UniBrace L Resilient Sway Braces When an isolated masonry or stud partition requires bracing to the adjacent vertical structure, this sway brace acoustically decouples the two walls. Composite material designed to reduce the sound transmission from ductwork, piping, and equipment housings by combining a fire-rated limp mass barrier with a decoupling quilted fiber glass lining. (KNM-100AL is available without the quilted fiberglass lining) Fire Rated Indoor or Outdoor Noise Barrier Material Barrier Overlap Tab for Fast, Noise-Tight Installation Insertion Loss Tested as a duct wrap over 2" fiberglass board (ASTM E1222-90) Frequency, Hz KNM-100ALQ 2 125 10 250 16 500 27 1000 35 Tested as a duct wrap directly over duct (ASTM E1222-90) Frequency, Hz KNM-100ALQ 3 125 6 250 7 500 18 1000 24 2000 34 2000 27 4000 33 4000 28

UniBrace Quick and easy solutions to challenging isolation hurdles. Head of Wall Isolation Single L Double L Soffit Isolation Plumbing Isolation Single F Double F Alara-Lukagro bv P.O. Box 15-2964 ZG Groot-Ammers - The Netherlands +31 (0) 184 661 700 - info@alara-lukagro.com - www.alara-lukagro.com