Double solenoid valve Combined pressure regulator and safety valves Gas-air-ratio-control MBC-...-VEF DN 65 - DN 100



Similar documents
Pressure switches for gas and air Pressure sensors

Valve Proving System VPS 504 Series S06 (120 VAC) Series S05 (24 VDC)

M/MR Modulating Valves TABLE OF CONTENTS DESCRIPTION SPECIFICATIONS. For Atmospheric, Infrared, and Direct Fired Burners

4/2-Way Pneumatic Solenoid Valve

Pressure Switch for gas and air

Assisted lift operated 2/2-way solenoid valves Type EV250B

3/2-way Solenoid Valve, direct-acting, NC or NO

Valve series MN-06 acc. to NAMUR, 3/2-way G1/4 750 Nl/min (0.762 Cv)

Flow controller with integrated control valve (PN 16, 25, 40*) AFQM, AFQM 6 - return and flow mounting

Self-operated Pressure Regulators Universal Pressure Reducing Valve Type 41-23

Fluxi 2000/TZ Turbine Gas Meter

820 NOVA mv THERMOPILE POWER SUPPLY THERMOELECTRIC SAFETY DEVICE SERVO-CONTROLLED PRESSURE REGULATOR SHUT-OFF SOLENOID VALVE.

System 8. ü ( System 8

Type 3353 Angle Seat Valve

Solenoid valves Type EVU

Digital inductive conductivity transmitter

Ball valve C 16 valve ball completely moulded in place, extremely low clearance volume, high k v value

Butterfly valves BVG, BVGF, BVA, BVAF, BVH, BVHS, BVHM

3/2-, 5/2- and 5/3-way Solenoid Valves for process pneumatics

PRESSURE REDUCING VALVES

Pressure transmitter For general industrial applications Model A-10

Pneumatic Control and Shut-off Butterfly Valve Pfeiffer Type BR 14b/31a and Type BR 14c/31a

T U R B I N E G A S M E T E R

3/2, 5/2, 5/2 bistable and 5/3 way pneumatic solenoid valve

Compact pressure switch Flameproof enclosure Ex d Model PCA

BERMAD Waterworks. Quick Active Check Valve. 700 Series. Model 740Q. Features and Benefits. Major Additional Features

3/2-way Mini Solenoid Valve

2/2 and 3/2 Way Size 6 Seat Valves

DMP 331. Industrial Pressure Transmitter for Low Pressure. Stainless Steel Sensor

Solenoid valves 2/2-way direct-operated Type EV210A

SLAM-SHUT VALVE. Type OSE. Europe, Middle East, Africa and Asia Pacific Documents Only. Process Management TM

Pneumatic Shut-off Butterfly Valve Type 3335/31a SRP or DAP

Electric Rotary Actuator - On/Off or programmable control actuator

3/2- and 2/2-way cartridge valve type BVE

Proportional pressure regulators VPPE

Electrically operated valves Series M-05, 3/2-, 5/2- and 5/3-way G1/8 650 and 750 Nl/min (0.661 and Cv)

SKP Series SKP15U.. Gas Valve Actuator with Safety Shutoff Function

VDL 53 - Vacuum drying oven for flammable solvents

Product data sheet. JUMO MIDAS Pressure Transmitter. Sales No. Order code JUMO AS /

Type and Type Pneumatic Control Valves Type 3510 Micro-flow Valve

3/2, 5/2, 5/2 bistable and 5/3 way pneumatic solenoid valve

How To Use A Flowmeter

2-Port Self-acting Temperature Control Valve Selection for Heating and Cooling Applications

Position Transducers with Restoring Spring 10, 25, 50, 75, 100 mm TR, TRS Series

Series 240 Type and Type Pneumatic Control Valves Type 3244 Three-way Valve

Mustang Series PRESSURE REDUCING CONTROL VALVE WITH PRESSURE SUSTAINING FEATURE. M115-2 (Globe) M (Angle) Schematic. Standard Components

Vacuum drying oven for non-flammable solvents

Digital pressure gauge for industrial applications Model DG-10-S, Standard version Model DG-10-E, Enhanced version

97300 NAMUR series, 3/2 & 5/2 Indirect solenoid actuated spool valve

Solenoid Valve Island Type 3965

M A N U A L

Line rupture protection valves type LB

BERMAD Waterworks. Pressure Relief/Sustaining Valve. 700 Series. Model 730. Features and Benefits. Major Additional Features

Cable Plug acc. to DIN EN , Form A

Eurovacuum EV Series. Single Stage Oil Sealed Rotary Vane Pump

Rittal TopTherm fan-and-filter unit

VdS en. VdS Guidelines for water extinguishing systems. Non-return valves. Requirements and test methods. VdS en : (01)

Direct steam injection humidifiers

PRESSURE REDUCING CONTROL VALVE

UM/ /2 or 5/3 Solenoid and air pilot actuated soft spool valves

Pressure regulating valve with modulating kit, type DRV

Series description: Wilo-Drain TC 40

Custom configuration such as modified angle dimensions, other flange standards, 3-way function, alternative materials.are available on request.

D634-P Series Direct Drive Proportional Valve with Integrated 24 V Electronics ISO 4401 Size 05

CRN A-F-G-E-HQQE 3x400D 50 HZ

Backflush filter R8-30W

Refrigeration Compressed Air Dryer Buran Ultrapulse

System 6000 Electropneumatic Converter for Direct Current Signals Type 6116 i/p Converter

Hydraulic Control Solutions

ABB i-bus KNX Switch Actuator, x-fold, 16 A, MDRC SA/S x , 2CDG1101xxR0011

Control- and feedback head for integrated mounting on Robolux valves Type 2036

VP23, 3-way proportional pressure control valves Seat valve with μp-driven pressure control

Series P215PR/RM Direct- and Remote-Mount Pressure-Actuated Condenser Fan Speed Controllers for Single-Phase Motors

Butterfly Valves PN 6/10/16 for flanged connection

AIR-AIR PRESSURE MULTIPLIER (BOOSTER)

Duplex Filters 40 FLDK 0008(C)-0120(C)

Valves. Sub-Base Mounted Valves to ISO 5599/2

RY2 miniature industrial relays

Electro-hydraulic pressure switches type DG

3/2-way pneumatic cartridge solenoid valve

Series description: Wilo-Star-Z

4 Posiflow Proportional Solenoid Valves

Magnetic and Hydraulic-Magnetic Circuit Breaker 8340-G2...

Electronic pressure switch with display Model PSD-30, standard version Model PSD-31, with flush diaphragm

CRN5-5 A-FGJ-G-E-HQQE 3x230/400 50HZ

VR46../VR86.. series COMPACT AUTOMATIC COMBINATION GAS CONTROLS APPLICATION. Contents PRODUCT HANDBOOK

PRESSURE REDUCER AND RELIEF VALVES WITH METALLIC BELLOW FOR WATER STEAM

type V46, solenoid or pneumatic operated

SHARKY 775 COMPACT ENERGY METER ULTRASONIC

kymanual or Automatic - it s your Choice

Pluggable interface relays CR-P Pcb relays

Electro-pneumatic control valves

Self-operated Temperature Regulators Type 1 to Type 9. PN 16 to 40 Class 125 to 300 DN 15 to 250 NPS ½ to 10 G ½ to 1 Up to 350 C Up to 660 F

Linear Luminaire for Fluorescent Lamps Series EXLUX 6001

DRYPOINT AC HP PREMIUM HIGH-PRESSURE DRYING

2- and 3-port valves with flanged connections, PN 10

DEK-REL- 24/1/SEN. Extract from the online catalog. Order No.:

Directional seated valves type VP 1

Series description: Wilo-Yonos MAXO-D

SICONT Limit Switches Type 3SE3 upto 500 VAC, 600 VDC, 10A

Transcription:

Double solenoid valve Combined pressure regulator and safety valves Gas-air-ratio-control DN 5 - DN 00 7. Printed in Germany Edition 05.5 Nr. 0 Technical Description The DUNGS multiple actuator integrates valves and gas-air ratio regulator in one compact unit: - Solenoid valves up to 500 mbar (50 kpa) as per DIN EN Class A Group - Fine setting of gas and air pressure ratio - Servo pressure regulator as per DIN EN class A group ; EN 07- - Internal stepping lines for optimised outlet pressure stability, external as an option. - Flange connection as per ISO 7005 - Easy to install As this system has a modular design, we can offer individual solutions with valve testing system, mini/maxi pressure switch and pressure limiter. Despite the compact design, high flow rates can be achieved at low pressure difference. Application The gas-air ratio regulator permits optimal mixture formation in forced air burners and premix burners. This applies to modulating and two-stage variable operating modes. Suitable for gases belonging to gas families,, and other inert gaseous media. Approvals EU type test approval as per EU Gas Appliance Directive. CE-005 BO 0 EU type test approval as per EU Pressure Equipment Directive: CE00 Approvals in other important gas-consuming countries.

Functional Description Gas flow. If the valves V and V are closed, chamber a is subjected to inlet pressure up to the double seat of the valve V.. The min. pressure switch (option) is connected to chamber a via a bore hole. If the inlet pressure exceeds the desired value set on the pressure switch, the pressure switch connects through to the gas burner control system.. The valves V and V open after they are enabled by the gas burner control system. Gas flow through chambers a, b and c is enabled. Functional description of the combined valve-regulator unit at valve V A regulator (pressure regulator unit) with admission pressure compensation is integrated in valve V. The plunger V is not connected to the valve disc unit. When the plunger opens, it preloads the compression spring and releases the regulator unit. When the plunger closes, the closing pressure is applied directly to the valve discs of the regulator unit. Valves V and V are driven together electrically. When valve V is in the closed position, it closes off the pressure chamber under the working diaphragm M so that this chamber is not affected by the inlet pressure p in chamber a. The plunger of valve V controls the valve V. The pressure under the working diaphragm M depends on a variable flow cross-section D. The comparison diaphragms for burner pressure p Br and blower pressure p L are connected with a bar. The ratio V can be set by shifting the bearing point. The zero point compensation N acts on this bar. Ambient pressure p amb or firing chamber pressure p F must be applied to the opposite side of the comparison diaphragms. The firing chamber overpressure reduces the burner pressure when the ratio V >. If there are any changes in the equilibrium of forces, the flow cross-section D after the valve V is changed. The pressure under the working diaphragm is re-adjusted, and the valve disc unit V changes the free cross-section. Functional description valve V The plunger of the valve V is connected to the valve disc unit. When the plunger opens, it preloads the compression spring. The valve V opens completely without any delay. The valve V is actuated by the valve V. When the valve V is in the closed position, it closes off the area under the working Schematic diagram V Main valve V Main valve V Control valve V Control valve M D V N Pressure taps, gas train diagram p Working diaphragm Restrictor Ratio setting Zero point compensation diaphragm M so that this area is not affected by the burner pressure. Closing function If there is an interruption in the power supply to the solenoid coils of the main valves V and V, they are closed by the compression springs in <s. V a V V M b Gas/air ratio control V N a, b, c Pressure chambers in flow direction p Inlet pressure p Br Burner pressure, outlet pressure Ambient pressure p amb V c D 7 9 pbr pf pamb pl,,, 5 Screw plug G /, Screw plug G / 7,, 9 Stepping line p Br, p F, p L 5 9 5 9 7 0

Technical Data Nominal widths Max. operating overpressure Inlet pressure range Burner pressure range Guiding range Media Ambient temperature Dirt trap device Pressure switch Servo pressure regulator Ratio setting range V Zero point compensation N Solenoid valve V, V Measuring gas connection Burner pressure monitoring device p Br Stepping line Voltage / frequency Electrical connection Power / current draw Switch-on duration Degree of protection DN 5 0 00 Connection flanges as per EN 09- for welding neck flanges as per DIN (PN) DN 5 - DN 00 Length as per DIN 0 part, series F. 500 mbar (50 kpa) p e : 5 mbar (.5 kpa) to mbar ( kpa) p Br : 0,5 mbar (0.05 kpa) to 00 mbar (0 kpa) : 0, mbar (0.0 kpa) to 00 mbar (0 kpa) p L Gases belonging to gas families,, and other inert gaseous media. -5 C to + C Filter. A suitable gas filter must be connected upstream. For further information, see data sheet.0 Gas and air filter. The system can be equipped with pressure switch types GW A5, ÜB A, NB A as per DIN EN 5. In case of DN 5 GW A5 cannot be mounted on item. For further information, see data sheets 5.07 and 5.0 Pressure switches for DUNGS multiple actuators. Pressure regulator with admission pressure compensation, sealed with valve V when switched off, as per DIN EN Class A Gas-air ratio regulator with adjustable ratio V as well as zero point compensation N and firing chamber pressure connection Ratio V = p Br / p L 0.75 : :, other ratios on request possible Valve as per DIN EN Class A Group ; fast-closing, fast-opening G / DIN ISO ; at inlet and outlet flanges, G / on both sides after the filter, on both sides between V and V, after V (if the pressure switch is assembled, it may not be possible to install a measuring gas connection in some cases) after valve V G / connection as per DIN ISO for burner pressure (p Br ; gas) Stepping and connection lines must be made of steel and PN, DN. Condensate from stepping and connection lines may not enter the fitting. The operating and assembly instructions must be strictly followed. ~ (AC) 50 - Hz 0 V -5 % +0 % Standard voltages: 0-0 VAC, VDC Plug-in connection as per DIN EN 750-0 at ~ (AC) 0 V; +0 C: see type overview 00 % duty IP 5 as per IEC 59 (EN 59) Material used for gas-conveying parts Housing Diaphragms, seals Solenoid drive cast aluminium NBR-based, Silopren (silicone rubber) aluminium, steel, brass Installation position Power / current draw at ~(AC) 0 V, + 0 C all indications are effective values Vertical with upright solenoid Type MBC-900-5 MBC-00-0 MBC-5000-00 Starting power approx. [W] x 95 x 5 x 5 Holding power approx. [W] x 0 x 5 x 5 Break-away starting current [A] x 0.5 x 0.5 x 0.5 Holding current [A] x 0.0 x 0.0 x 0.0

Dimensions Type Ordering No. 0 VAC DN P max. I max. [W] ~[A] ~(AC) 0 V Opening time a b Dimensions [mm] c d e f Solenoid No. Switching operations/h Weight [kg] MBC-900-VEF-5 0 DN 5 90. < s 90 5 9 5/P. MBC-00-VEF-0 DN 0 50. < s 0 90 9 50 /P.0 MBC-5000-VEF-00 0 DN 00 50. < s 50 5 9 500 50 5 7/P.

Characteristic curves for volume flow pressure difference in steady state with filter. A suitable gas filter must be used. must be checked and enabled in the application MBC-900-VEF-5 500 00 00 00 50 MBC-900-...-5 Recommended operating range 00 0 50 0 0 p [mbar] 0 0 5 Basis + 5 C, 0 mbar, trocken Based on + 5 C, 0 mbar, dry Base + 5 C, 0 mbar, sec Base + 5 C, 0 mbar, secco 5 0 0 0 0 50 0 00 00 00 00 0 00 000 000 Vn [m /h] Luft / Air / Aria dv =,00 5 0 0 0 0 50 0 00 00 00 00 0 00 000 Vn [m /h] Erdgas/Natural gas/gaz Naturel/Gas metano dv = 0,5 000 000 must be checked and enabled in the application MBC-00-VEF-0 500 00 00 00 50 00 0 50 0 0 MBC-00-...-0 Recommended operating range p [mbar] 0 0 5 Basis + 5 C, 0 mbar, trocken Based on + 5 C, 0 mbar, dry Base + 5 C, 0 mbar, sec Base + 5 C, 0 mbar, secco 5 0 0 0 0 50 0 00 00 00 00 0 00 000 000 Vn [m /h] Luft / Air / Aria dv =,00 5 0 0 0 0 50 0 00 00 00 00 0 00 000 Vn [m /h] Erdgas/Natural gas/gaz Naturel/Gas metano dv = 0,5 000 000 f = V gas used = Air density Density of the gas used V air x f Gas type Natural gas Town gas Liquefied gas Air Density [kg/m ] 0, 0,5,0, f,, 0,77,00 5

Characteristic curves for volume flow pressure difference in steady state with filter. A suitable gas filter must be used. must be checked and enabled in the application MBC-5000-VEF-00 500 00 00 00 50 Recommended operating range 00 0 50 0 0 MBC-5000-VEF-00 p [mbar] 0 0 5 Basis + 5 C, 0 mbar, trocken Based on + 5 C, 0 mbar, dry Base + 5 C, 0 mbar, sec Base + 5 C, 0 mbar, secco 0 0 0 0 50 0 00 00 00 00 0 00000 000 000 000 Vn [m /h] Luft / Luft / Aria dv =,00 0 0 0 50 0 00 00 00 00 0 00000 000 000000 00 Vn [m /h] Erdgas/Naturgas/Gaz Naturel/Gas metano dv = 0,5 mechanically open 500 00 00 00 50 00 0 50 0 0 MBC-900-VEF-5 MBC-00-VEF-0 MBC-5000-VEF-00 0 0 5 Basis + 5 C, 0 mbar, trocken Based on + 5 C, 0 mbar, dry Base + 5 C, 0 mbar, sec Base + 5 C, 0 mbar, secco 0 0 0 0 50 0 00 00 00 00 0 00 000 Vn [m /h] Luft / Air / Aria dv =,00 000 000 000 0 0000000 0 0 0 50 0 00 00 00 00 0 00 000 000 000000 00 0000000 Vn [m /h] Erdgas/Natural gas/gaz Naturel/Gas metano dv = 0,5

System accessories Pressure switch ÜB A, NB A GW A5 Gas filter GF/ DN Valve testing system VPS 50 S0 Motorised butterfly valve DMK DN Line socket pole + PE Adapter, pressure gauge flange set G/ Ignition gas flange G / Cover, on the side Further information Data sheet 5.07 Data sheet 5.0 Data sheet.0 Data sheet.0 Data sheet. Ordering no. 0 9 75 9 00 9 005 The DMV-VEF has been designed for direct assembly of DUNGS system accessories and supplementary equipment. Flanges, plug-in connection and system accessories must be ordered separately. 7

Double solenoid valve Combined pressure regulator and safety valves Infinitely variable operating mode DN 5 - DN 00 Key data Key data Application Application Gas Type of gas / specific density [kg/m ] Volumetric flow V [m /h] V min. V max. Inlet pressure p e [mbar] p e,min. p e,max. Burner pressure p Br [mbar] at V min. at V max. Control range, power range Time taken to re-adjust volume restrictors from small load to large load [s] Starting load [m /h] Company / address Name / person in charge Telephone We reserve the right to make changes in the interest of technical progress. Head Offices & Factory Karl Dungs GmbH & Co. KG Siemensstraße -0 D-7 Urbach, Germany Telefon +9 (0)7-0-0 Telefax +9 (0)7-0- Postal address Karl Dungs GmbH & Co. KG Postfach 9 D-7 Schorndorf, Germany e-mail info@dungs.com Internet www.dungs.com