Programmable Relays. ZEN Series. ZEN Programmable Relays. Applications



Similar documents
Type: EASY719 DC RC Article No.: Ordering information Relay outputs Quantity 6 Power supply V DC 24 V DC. Description

38 Series - Relay interface modules A

Multifunction Digital Timer

CQM1-SF200/CS1W-SF200

Cat. No.Z211-E1-03 ZEN. Programmable Relay OPERATION MANUAL

TM7BDM8B expansion block - TM7 - IP67-8 DI/DO - 24V DC A - M8 connector

38 Series - Relay interface modules A

RM4TG20 three-phase network control relay RM4-T - range V

Electronic timer CT-AHD.12 OFF-delayed with 1 c/o (SPDT) contact

Smart DeviceNet Remote I/O Terminals

RM17TE V AC. Main. Product or component type. Product specific application. Relay monitored parameters 250 V DC 5 A DC

MILLENIUM INSTALLATION MANUAL NTR 735 A. Simple Automation Control Module (MAS)

NX safety stand-alone

Cross-beam scanning system to detect slim objects. 100 mm in

Process modules Digital input PMI for 24 V DC inputs for 120 V AC inputs

Analog signal converters CC-E I/I Current / current isolators

Specifications H8CA-S H8CA-S RATINGS. Approved by the following standards CHARACTERISTICS

38 SERIES. Relay interface modules A. EMR Electromechanical Relays. Common features. SSR Solid State Relays. 6.

EXTERNAL DIMENSIONS AND PARTS

Duct Humidity Transmitter

Electronic timer CT-VBS OFF-delayed without auxiliary voltage, for DC contactors Data sheet

Telephone- and leased line modem for industrial applications TD-36

Single-phase ( V) voltage monitoring: Undervoltage Overvoltage Window mode (overvoltage + undervoltage) Voltage fault memory selectable

MasterINTERFACE 39 Series - Relay interface modules

PD30ETB20xxIS. Photoelectrics, Background Suppression reflective with IR light. Main features. Description

Rack mounted telephone- and leased line modem for industrial applications

ABB 1. Three-phase monitoring relay CM-PFS. Data sheet. Features. Approvals. Marks. Order data. Order data - Accessories. Application.

RM35UA13MW. range V. Main. Product or component type. Relay monitored parameters

40.3. Control Relays and Timers

MCR-VDC-UI-B-DC. Voltage Transducer for DC Voltages. INTERFACE Data Sheet _en_01. 1 Description

Control Devices Catalogue. Control Devices. Preferred and Standard Products

Safety technique. Emergency stop module BO 5988 safemaster

Temperature monitoring relays CM-TCS Monitoring relays for monitoring temperatures with a PT100 sensor (2- or 3-wire connection)

RISH CON - Hz. Salient Features : Application : Product Features: FREQUENCY TRANSDUCER

650W Single Output Power Supply 15V 24V. 27V 48V Rated Current. 0 ~ 100A 0 ~ 50A 0 ~ 40A 0 ~ 27A 0 ~ 24A 0 ~ 13.6A Rated Power

1000W Single Output Power Supply 15V 24V. Protection type: Total Power limit, Latch-style (Recovery after reset AC power ON or inhibit)

Preset Counter signo 721

CPU systron S S S 250c. systron S S S 250c. CPUs to the process modules. Stand-alone PLC

Quick Connect. quick - simple - efficient.

g9sp Programmable Safety controllers compact Stand-Alone Programmable controller NEW! example of System configuration G9SP

Vroom Hardware manual ver Code 114VROOHWE00. Vroom CANBUS USER INTERFACE WITH LCD GRAPHIC DISPLAY AND WITH TEMPERATURE AND HUMIDITY SENSOR

650W Single Output Power Supply

Automation System TROVIS 6400 TROVIS 6493 Compact Controller

Liquid Leakage Sensor Amplifier

Voltage monitoring relays CM-ESS.2 For single-phase AC/DC voltages

Count input Display Time range h or 3999d23.9h (selectable) 999h59m59s or 9999h59.9m (selectable) 3. Case Color B: Black

Power Supply Unit, Primary Switched, Narrow Design MINI-PS-12-24DC/24DC/1

How To Control A Power Supply With A Mini Transmitter And Switch (Power Supply)

MasterINTERFACE 39 Series - Relay interface modules

Model: DC-A2IO Advanced HVAC Controller

Positive-guided relay outputs: 3 safety contacts (N/O), instantaneous. 1 auxiliary contact (N/C), instantaneous

Energy Management Energy Meter Type EM23 DIN

Disturbance Recoder SPCR 8C27. Product Guide

Three-phase monitoring relay CM-PFE

COM. port RS232C RS232C RS232C RS485. Thermocouple input. Part number. Not available. Not available. Available. Not available Available RS485.

Absolute Rotary Encoder E6CP

Memory Card (See note.)

Your Advantages For safety application up to PL e / Cat. 4 e.g. SIL 3 Manual or automatic start * see variants. Applications.

80 Series - Modular timers 16 A. Features

TRACTION NETWORK MONITORING AND PROTECTION SYSTEM SMTN-3 CITY ELECTRIC TRANSPORT RAILWAYS METRO INDUSTRY

VEO. V4PF480Y/277VSYTK02 Art.Nr.: V4PF480Y/277VSYTK02P Art.Nr.: TECHNICAL DATA

Electronic overload relay EF19 and EF45

STEP-PS/1AC/12DC/1.5. Extract from the online catalog. Order No.: DIN rail power supply unit 12 V DC/1.5 A, primary switched-mode, 1- phase

Programmable Terminal. NPSeries. Easy Setup with the Low-cost, Compact NP Series

Programmable Logic Controllers

Programmable Controller G Series. New. Models

40 Series - Miniature PCB/Plug-in relays A. Features

Power-monitoring unit PowerLogic System. Technical data sheet. Power Meter Series 800

Technical data. General specifications. Signal voltage V DC Signal duration. 1 s Input 2. Signal voltage. 1 s Analog output.

RY2 miniature industrial relays

The E5CN provides communications or event input functionality when mounted with one of the following Option Boards.

AUTOMATIC TRANSFER SWITCH. Changeover Type from 250A to 2500A

Multifunction devices

HMIGTO4310 advanced touchscreen panel 640 x 480 pixels VGA- 7.5" - TFT - 96 MB

RISH EM 3490 DS Dual Source Energy Meter RISH EM 3490 DS. Application : Product Features:

ABB 1 NEW. Three-phase monitoring relay for grid feeding CM-UFS.1. Data sheet. Features. Approvals. Marks. Order data. Order data - Accessories

Bulletin 150 SMC Flex Smart Motor Controller Specifications

Analogue Input, 4-fold, MDRC AE/S 4.1, GH Q R0001

Portal Software GSM-PRO Run LED displays module activity Com LED displays activity on the GSM network GSM-PRO

Magnetic and Hydraulic-Magnetic Circuit Breaker 8340-G2...

Relés e Contatores de Estado Sólido SIRIUS

Vision OPLC. V R34/V350-J-R34 Technical Specifications. Technical Specifications

Electronic overload relay EF65, EF96 and EF146

V350-R34 V350J-R34. npn inputs pnp inputs

Thermistor motor protection relays CM-MSS.22 and CM-MSS.23

Power Meter Series 700

49 Series - Relay interface modules A. Features

Series AMEPR30-AZ up to 2.5A AC-DC / DC-DC LED Driver / Converter

Adjustment functions for both span and shift have been incorporated

34 Series - Slim electromechanical PCB relays 6 A. Features SERIES 34.51

ABB i-bus KNX Fan Coil Actuator, MDRC FCA/S 1.1M, 2CDG R0011

Digital input modules

Ordering Information. Cylindrical Proximity Sensor E2E/E2E2

Voltage monitoring relays CM-ESS.2 For single-phase AC/DC voltages

Voltage Regulator SPAU 341 C. Product Guide

JNIOR. Overview. Get Connected. Get Results. JNIOR Model 310. JNIOR Model 312. JNIOR Model 314. JNIOR Model 410

Solid-State Timer H3G

Fixed - Over/Under voltage limits, ( ) U N respectivity Link selectable - 5 min or 10 min delay. Fixed limits

Sensing method Appearance a Connection o method Sensing distance Model NPN output PNP output Through-beam Pre-wired (see note 3) Connector.

48 SERIES Relay interface modules 10 A

Transcription:

Programmable Relays ZEN Series Relay, Timer, Counter, and Time Switch Functions Weekly Timer and Calendar Timer Functions Twin Timer Function (Separate ON/OFF Times) Two Analog Input Channels (DC Models Only) 8 Digit Timer and 8 Digit Comparator Flexible Expansion Enables Up to 44 I/O Points 1 to 4 Vdc Operation (DC Models) Program from Front Panel or Using Software. All models shown smaller than actual size. ZEN Programmable Relays Ideal for small-scale control applications, the ZEN provides an economical alternative to discrete timers, counters and generalpurpose relays. This single unit easily provides relay, timer, counter, and time switch functions. Wiring work is greatly reduced because separate wiring is not required for devices such as timers and counters. Programs can be easily written, saved, and monitored by personal computer. Programs can also be simulated on the personal computer without connecting to the ZEN. Communication models with an RS485 interface allow production line conditions to be remotely monitored by monitoring the ZEN control status. Applications Designed for use in automation for commercial and industrial sectors, ZEN programmable relays provide the ideal solution for lighting, energy management, industrial control, watering and pump control.. ZEN-8E1DR. 1

CPU Units with 10 CPU I/O Units Points with 10 I/O Points CPU Units with 10 I/O Points 4.7 (Sliding: (0.18) 13 max) CPU Units with 0 I/O Points CPU Units with 0 I/O Points CPU Units with 0 I/O Points 60 (.36) 11.5 (4.30) 11.5 (4.30) 11.5 (4.30) Ratings Specifications MODEL NO. ZEN-xCxAR-A-V/ ZEN-xCxDx-D-V/ZEN-8E1Dx CPU Units with 10 I/O Points CPU Units with 0 I/O Points Rated supply voltage Dimensions with Battery Unit 100 to 40 Vac, 50/60 Hz 1 to 4 Vdc (DC ripple rate: 5% max.) CPU Units with 1087.5 I/O (3.44) Points CPU Units with 0 I/O 140 Points (5.51) Operating Dimensions with voltage Battery 44 Unit (1.73) range 85 to 64 Vac 1.510.8 (4.8) to 8.8 Vdc 87.5 (3.44) 140 (5.51) Power consumption /ZEN-10CAR-A-V/ ZEN-10CxDR-D-V 1/4 Vdc: 3 W max CPU Units without ZEN-10C3AR-A-V (ZEN-10C3DR-D-V:.8 W max) 100 Vac: 5 VA max, 40 Vac: 7 VA max CPU Units with 10 I/O Points CPU Units with ZEN-10CxDT-D-V 0 I/O Points 1/4 Vdc: W max ZEN-10C4AR-A-V ZEN-0CxDR-D-V 1/4 Vdc: 4 W max Dimensions with Battery Unit 100 87.5 Vac: 6 VA max, 40 Vac: 8 (3.44) VA max ZEN-0CxDT-D-V 1/4 Vdc: W max 140 (5.51) ZEN-0CxAR-A-V 100 Vac: 7 VA max, 40 Vac: 10 VA max Power consumption /ZEN-10CAR-A-V ZEN-10CxDR-D-V 1/4 Vdc: 4 W max CPU Units with three 100 Vac: 6 VA max, 40 Vac: 8 VA max ZEN-10CxDT-D-V 1/4 Vdc: 3 W max ZEN-10C4AR-A-V ZEN-0CxDR-D-V 1/4 Vdc: 5 W max 100 Vac: 7 VA max, 40 Vac: 9 VA max ZEN-0CxDT-D-V 1/4 Vdc: 3 W max ZEN-0CxAR-A-V 100 Vac: 8 VA max, 40 Vac: 11 VA max ZEN-8E1DR 1/4 Vdc: W max 100 Vac: 3 VA max, 40 Vac: 4 VA max Inrush current ZEN-10CxAR-A-V 4.5 A max ZEN-10CxDx-D-V 30 A max ZEN-0CxAR-A-V 4.5 A max ZEN-0CxDx-D-V 30 A max 4 A max ZEN-8E1DR 15 A max Ambient temperature 0 to 55 C (-5 to 55 C) for ZEN-xCxx-x-V models Ambient storage -0 to 75 C (-40 to 75 C) for ZEN-xCxx-x-V models temperature Ambient humidity 10 to % (with no condensation) Ambient conditions No corrosive gases Mounting method Surface mounting, DIN track mounting [standard (vertical) installation and horizontal installation] Terminal block Solid-line terminal block (use solid wire or fine-stranded wire) 6 Terminal screw 0.565 to 0.6 N m (5 to 5.3 in-lb) tightening torque Degree of protection IP0 (mounted inside a control panel) 60 (.36) 60 (.36) 56 (.0) 56 (.0) 56 (.0) Unit Unit Mounting Holes Unit Mounting Holes 5.5 (0.1) 5.5 Note: Use 5.5M4 screws (0.1) for mounting Note: Use (0.1) M4 screws for mounting Note: Use M4 screws for mounting Two, M4 Two, M4Two, M4 56 (.0) 56 (.0) 44 56 (1.73) (.0) 60 (11.5)* * 60 The (11.5)* dimensions in parentheses refer to models with 0 I/O points. * The dimensions in parentheses refer to models with 60 (11.5)* 0 I/O points. * The dimensions in parentheses refer to models with 0 I/O points. Dimensions: mm (in) 6 6

Dimensions with Battery Unit CPU Units with 10 I/O Points CPU Units with 0 I/O Points 87.5 (3.44) 140 (5.51) (0.078) 35 (1.37) DIN Track Hook (Using Slide) 7.6 (0.9) Two, 3.5 dia. (.1 ) Two, M3 0 (. ) 97 (3.81) 0 (. ) 97 (3.81) (0.078) Specifications Control Method: Stored program control I/O Control Method: Cyclic scan Programming Language: Ladder diagram Program Capacity: 96 lines (3 input conditions and 1 output per line) Max No. of Control I/O Points: 44 points CPU Units with 0 I/O Points: 1 inputs and 8 outputs : 4 inputs and 4 outputs each, up to 3 units LCD Display: 1 characters 4 lines, with backlight Operation Buttons: 8 (4 cursor buttons and 4 operation buttons) User Program Back-Up: Internal EEPROM, memory cassette (optional) Power Interruption Hold: Internal holding bit status, holding timer/counter present values, calendar and clock (year, month, day of month, day of week, time) Super Capacitor Backup Time: days min (5 C) Life of Optional Battery: 10 years min (5 C) Calendar and Clock Function: Accuracy: ±15 s/month (at 5 C) 7.6 (0.9) Timer Accuracy: 0.01s Unit: -0.05%, -10 ms max 0.0 min/s Unit: -0.05%, -1 s max 0.03 h/min Unit: -0.05%, -1 min max Maximum Counting Speed: 150 Hz 8-digit counter (F) set to high-speed operations (CPU units with DC power supplies only) (the counting speed may be less than 150 Hz depending on the cycle time of the program Insulation Resistance: 0 MΩ (at 500 Vdc) min between power supply terminals and all output terminals, terminals of different output circuits; between all terminals of CPU unit and all terminals of expansion I/O unit Insulation: Reinforced insulation between power supply or input terminals and output terminals; terminals of different output circuits; all terminals of CPU unit and all terminals of expansion I/O unit; no separation between power supply and input terminals of the same unit, power supply terminals of CPU unit and computer connector, battery unit connector, or all expansion unit connectors (all interfaces are live parts) Dielectric Strength: 300 Vac, 50/60 Hz for 1 min (leakage current 1 ma max) between power supply terminals and all output terminals; terminals of different output circuit; all terminals of CPU unit and all terminals of expansion I/O unit Dimensions: mm (in) 6 Vibration Resistance: Conforms to IEC60068--6, 5 to 9 Hz with 3.5 mm single amplitude, 9 to 150 Hz acceleration 9.8 m/s, 10 sweeps each in X, Y, and Z directions (1 octave/min) Shock Resistance: Conforms to IEC60068--7, 147 m/s, 3 times each in X, Y, and Z directions Weight: CPU Unit with 10 I/O Points: Approx 300 g max CPU Unit with 0 I/O Points: Approx 350 g max Expansion I/O Unit: Approx 10 g max Communications (type CPU Units) ZEN-10C4xR-x-V Communications: RS485 (-wire, half duplex) Synchronization Method: Start-stop synchronization Baud Rate: 40, 9600, or 19,00 bps Transmission Code: ASCII Data Bit Length: 7 or 8 bits Stop Bit Length: 1 or bits Error Detection: Vertical parity (none, even, odd), block check character (BCC) Flow Control: None Interface: RS485 Retry Function: None Node Number: 0 to 99 (default: 1), XX (broadcasting) 3

Approved Standards Specifications Safety standards culus: UL508/CSA C. No.14 Class I Div conforms to EN/IEC 61131- clause 11, excluding 11.7.. (overvoltage category and pollution degree II conforms to IEC 60664-1) *EMC Radiation field emission noise CISPR11 Class A, Group 1 terminal voltage emission CISPR11 Class A, Group 1 Electrostatic discharge immunity IEC61000-4- In air: 8 kv, in contact: 6 kv Electromagnetic field immunity IEC61000-4-3 10 V/m Electrical fast transient/ IEC61000-4-4 Power line burst immunity AC I/O: kv DC I/O: 1 kv Surge immunity IEC61000-4-5 Normal noise AC power supply, AC I/O: 1 kv DC power supply, DC I/O: 0.5 kv Common Noise AC power supply, AC I/O: kv DC power supply: 1 kv DC I/O: 0.5 kv Immunity to conducted disturbances IEC61000-4-6 3V induced by radio-frequency fields Momentary power interruption IEC61131- CPU units with AC power supplies: immunity 10 ms max CPU units with DC power supplies: ms max (level: PS1) * EMC conforms to EN 61131- clause 8 except in the following cases. When expansion I/O units with DC inputs are connected to a CPU unit with an AC power supply, the burst immunity between power supplies will be 1 kv. When the signal wire for transistor outputs exceeds 10 m, the surge immunity of DC output signal lines will not conform. CPU Units Specifications AC Inputs (Not Isolated) Input Voltage: 100 to 40 Vac +10%, -15%, 50/60 Hz Input Impedance: 6 kω Input Current: 0.15 ma/100 Vac, 0.35 ma/40 Vac ON Voltage: Vac min OFF Voltage: 5 Vac max ON Response Time: 50 or 70 ms at 100 Vac** OFF Response Time: 100 ms or 10 ms at 40 Vac** ** Can be selected using the DC Inputs I0 to I3 for Units with 10 I/O points, I0 to I9 for Units with 0 I/O Points (Not Isolated) Input Impedance: 5.3 kω Input Current: 4.5 ma (typ)/4 Vdc OFF Voltage: 5 Vdc max ON Response Time: 15 or 50 ms*** *** Can be selected using the input filter settings, except when I0 is being used for an 8-digit counter with a high-speed input. OFF Response Time: 15 or 50 ms 4 DC Inputs: I4 and I5 for Units with 10 I/O points, Ia and Ib for Units with 0 I/O Points (Not Isolated) DC Inputs Input Impedance PNP: 5.5 kω/14 Vdc min NPN: 100 kω/14 Vdc max 5. kω Input Current: PNP: 4.3 ma (typ)/4 Vdc NPN: 4.6 ma (typ)/4 Vdc OFF Voltage: 3 Vdc max ON Response Time: 15 or 50 ms Can be selected using the input OFF Response Time: 15 or 50 ms Analog Inputs Input Range: 0 to 10V External Input Impedance: 100 kω min Resolution: 0.1V (1/100 FS) Accuracy: ±1.5% FS (at ambient operating temperature within rated range) AD Conversion Data: 0 to 10.5V (in increments of 0.1V) Specifications AC Inputs (Not Isolated) Input Voltage: 100 to 40 Vac +10%, -15%, 50/60 Hz Input Impedance: 6 kω Input Current: 0.15 ma/100 Vac, 0.35 ma/40 Vac ON Voltage: Vac min OFF Voltage: 5 Vac max ON Response Time: 50 or 70 ms at 100 Vac OFF Response Time: 100 or 10 ms at 40 Vac Can be selected using the input DC Inputs ZEN-8E1DR: Not isolated ZEN-8E1DT: Photocoupler isolated Input Impedance: 6.5 kω Input Current: 3.7 ma (typ)/4 Vdc OFF Voltage: 5 Vdc max ON/OFF Response Time: 15 or 50 ms Can be selected using the input

Output Specifications (CPU Units and Expansion I/O Units) Units with Relay Outputs Maximum Switching Capacity: 50 Vac/8 A (resistive load; cos = 1), 4 Vdc/5 A (resistive load) use the following values for the total of all outputs CPU Units with 10 I/O Points: 0 A max (15 A max for communications-type CPU units) CPU Units with 0 I/O Points: 40 A max : 0 A max Minimum Switching Capacity: 5 Vdc/10 ma (resistive load) (failure level: P, reference value) Relay Life: Electrical: Resistive load; 50,000 times (cos = 1) Inductive Load: 50,000 times (cos = 0.4) Mechanical: 10 million times ON Response Time: 15 ms max OFF Response Time: 5 ms max Units with Transistor Outputs Maximum Switching Capacity: 4 Vdc +0%, 500 ma Leakage Current: 0.1 ma max Residual Voltage: 1.5V max ON Response Time: 1 ms max OFF Response Time: 1 ms max To Order Model No. ZEN-10C3AR-A-V ZEN-10C3DR-D-V ZEN-10C1DR-D-V ZEN-10C1DT-D-V ZEN-0C3AR-A-V ZEN-0C3DR-D-V ZEN-0C1DR-D-V ZEN-0C1DT-D-V Expansion I/O ZEN-8E1DT ZEN-8E1DR Description LCD display, 6 AC inputs, 4 relay outputs, AC power, no expansion I/O LCD display, 6 DC inputs, 4 relay outputs, DC power, no expansion I/O LCD display, 6 AC inputs, 4 relay outputs, AC power LCD display, 6 DC inputs, 4 relay outputs, DC power LCD display, 6 DC inputs, 4 transistor outputs, DC power LCD display, 1 AC inputs, 8 relay outputs, AC power, no expansion I/O LCD display, 1 DC inputs, 8 relay outputs, DC power, no expansion I/O LCD display, 1 AC inputs, 8 relay outputs, AC power LCD display, 1 DC inputs, 8 relay outputs, DC power LCD display, 1 DC inputs, 8 transistor outputs, DC power Expansion I/O, 4 DC inputs, 4 transistor outputs Expansion I/O, 4 DC inputs, 4 relay outputs Expansion I/O, 4 AC inputs, 4 relay outputs, battery unit. Ladder programs and parameter settings are saved to the CPU Unit EEPROM but calendar, clock, and holding timer bits and holding timer/ counter present values are held by the capacitor. Therefore, if the power supply is interrupted for days or more (at 5 C), this data will be reset. Use a battery unit for systems where the power supply may be interrupted for long periods. ZEN-ME01, memory cassette. Enables programs and parameter settings to be saved or copied to another ZEN. All models shown smaller than actual size. ZEN-CIF01, programming cable. Required for programming and simulating using ZEN-SOFT01V4 software. Ladder logic programs can be entered using the front-panel display and buttons, but the software makes it easier to visualize and the program can be simulated before downloading to the CPU unit. Software and Accessories Model No. Description ZEN-SOFT01V4 Programming software ZEN-CIF01 Programming cable, RS3C, m (6.5') Battery unit, 10 year min battery life ZEN-ME01 Memory cassette Ordering Examples: ZEN-10C3AR-A-V, programmable relay with 10 I/O, and ZEN-SOFT01V4, programming software, ZEN-CIF01, programming cable. ZEN-0C3DR-D-V, programmable relay with 0 I/O, and ZEN-SOFT01V4, programming software, ZEN-CIF01, programming cable. 5