An applicants guide to water supply boreholes



Similar documents
ources of Drinking Water

Guidelines For Sealing Groundwater Wells

FY08 SEWER POINT REPAIRS BID TABULATION

SECTION REMOVAL OR ABANDONMENT OF EXISTING UTILITIES AND UNDERGROUND STRUCTURES. 1. Trench excavation, backfill, and compaction; Section

STATE OF VERMONT AGENCY OF NATURAL RESOURCES DEPARTMENT OF ENVIRONMENTAL CONSERVATION WASTE MANAGEMENT DIVISION SOLID WASTE MANAGEMENT PROGRAM

How To Know If Your Well Water Is Safe

31. ECO-INFO -- SEPTIC SAFE PROTECT YOUR HEALTH AND ENVIRONMENT YOUR SEPTIC PUMP-OUT SYSTEM with SELF ASSESSMENT TROUBLE SHOOTING GUIDE

Development proposals will require to demonstrate, according to scale, type and location, that they:-

BUILDING A WORLD OF DIFFERENCE. Safe work in confined spaces

ANNEX 2 Emergency / Pollution Incident Response Plan

Section 402. STORM SEWERS

FY11 Sanitary Sewer Main Rehab and Point Repair Bid Tabulation

Guide to working on Public Sewers

MAP KEYS GLOSSARY FOR THE DRAINAGE AND WATER REPORT

CHAPTER 4 WELL COMPLETION AND MAINTENANCE

9.00 THE USE OF HUNTER LAND DRAINAGE PERFORATED PIPES. Hunter Underground Systems

YOUR SEPTIC SYSTEM UNCOVERED

On Site Treatment Systems

Universal Installation and Maintenance Instructions Double Wall Spill Containment Bucket (5 and 15 gal)

AIR RELEASE, CLEANOUT, AND SEWER MANHOLES

Shower and Floor Gullies Channel Drain and Tile Drain SECTION

Repairs Made With Under Pressure Installations Can Offer Reduced Risks And Expenses

Septic Systems and Their Maintenance

Proposed Construction of Basement Flood Risk Assessment. 35 Edwardes Square London W8 6HH

40 ltr Domestic Grease Trap GTO ltr Commercial Grease Trap GTO2. Rotational Moulders providing State of the Art Product Design and Developement.

1. Purpose and scope. 2. SEPA's role in hydropower and planning

Ontario Fire Code SECTION 5.13 DIP TANKS. Illustrated Commentary. Office of the Ontario Fire Marshal

Domestic heating Fuel storage tanks

SEPTIC SYSTEM CONSTRUCTION REQUIREMENTS ST. MARY S COUNTY HEALTH DEPARTMENT

Indiana State Department of Health Construction Guidelines for Gravity and Flood-Dose Trench Onsite Systems

Prepare a drainage system layout and specification notes for a low- rise building.

EXPLAINING GROUNDWATER AND WATER WELLS

Improving the flood resistance of your home. Advice sheet 6: Flood-resilient floors

SECTION ABANDONMENT OF SEWER MAINS

Fact sheet 6: for farmers

WHAT YOU NEED TO KNOW ABOUT LIVING NEAR INDIANA COAL MINES

Basements and Deep Building Construction Policy 2014

March 2006 DIVISION 3 - CW 2140-R3 TABLE OF CONTENTS

Section 5.0. Basements. Wall insulated externally. Wall insulated internally. Ba02. Product: Polyfoam ECO Floorboard Ba01.

PREVENTING GROUNDWATER POLLUTION: SECONDARY CONTAINMENT

DESCRIPTION OF STORMWATER STRUCTURAL CONTROLS IN MS4 PERMITS

Type of Sewer Systems. Solomon Seyoum

Recommendations Siting of monitoring bores Monitoring facilities at contaminated sites

Integrated Manhole Ladder System

Fact sheet 6: for farmers

Fact Sheet #1 Reducing the Risk of Groundwater Contamination by Improving Drinking Water Well Condition

San Joaquin County. Well Standards. (San Joaquin County Ordinance Code Section )

FARM A SYST Farmstead Assessment System. Drinking Water Well Condition

DIRECTIONAL DRILLING

Protecting your private water supplies. The possible causes of contamination and their remediation to prevent this risk.

Does Part of My Basement Floor Have to Be Removed to Install. Where Does the Water from the Sump Pump Go?...Page 5

SPECIFICATIONS FOR SEWER PIPE AND LINING INSERTION - TRENCHLESS; GENERAL GUIDELINES (As Provided by NASSCO)

SECTION STORM DRAINAGE SYSTEM

STATUS REPORT: Bacteria and Other Contaminants in Domestic Water Wells in the Jackson Purchase Region

Preventing Basement Flooding

City of Shelbyville Site Inspection Checklist

Properly maintaining your septic system will help reduce the. It s Your Septic System. Homeowner s Guide. Here s How to Take Care of It

SEPTIC TANKS AND SOAKAWAYS TO HOUSES AND THE BUILDING REGULATIONS

GUERNSEY OIL INSTALLATION GUIDELINES

53.03 MATERIALS FOR SEWER LINER PIPE AND FITTINGS: The following materials are approved for installation in sanitary sewer lines:

Gas Meter Clearances and Service Installation Requirements

SECTION SANITARY SEWER AND STORM DRAIN SYSTEMS

Florida Department of Environmental Protection

SECTION 10 WATER WELL SUPPLY SCOPE OF WORK

Homeowner s Guide to Maintaining a Sewage Treatment System

Specifications for Residential Property Owners Connection to New Public Sewer

Introduction. Do You Need A Water Right? Exempt Groundwater. Plan Ahead

CHAPTER 11 STORM DRAINAGE

Rehabilitation of an Aging Concrete Reservoir Adit Tower

EXCAVATION AND PILING NEAR SEWERS, STORMWATER DRAINS AND WATER MAINS

ALL YOU NEED TO KNOW...

Basement Moisture Problems

SEPTIC TANKS FOR THE COLLECTION & SETTLEMENT OF DOMESTIC SEWAGE

Construction Site Inspection Checklist for OHC By making use of some simple Best Management Practices (BMPs) a construction site operator can

Fiberstars Lighted Laminar Flow Fountain Installation Manual

Viet Nam Da Nang Waste water management

PERMEABILITY TEST. To determine the coefficient of permeability of a soil using constant head method.

Understanding Septic Tank Systems

Storm Sewer Trenchless Upgrade Alternatives and Recommendations

SECTION LS 2530 SANITARY SEWERS. A. General: Submit the following in accordance with The General Conditions.

PRIVATE WELL SEPARATION

ENVIRONMENTAL CODE OF PRACTICE FOR CONCRETE BATCH PLANT & ROCK WASHING OPERATIONS

Looking after your Septic Tank System

PBX Series Quick Fit Connector Bimetallic Steam Traps

Flood Risk Assessment and Drainage Impact Assessment: Planning Guidance for Developers


Confined spaces can be deadly. What is a confined space?

Interior Walls below and above ground OLDROYD THE ULTIMATE WATERPROOF MEMBRANE SYSTEM

Groundwater Protection Code: Use and construction of septic tanks and other non-mains sewerage

GROUND WATER CONTAMINATION INFORMATION

How To Retaining Wall Guide

Chapter 9: Water, Hydrology and Drainage Land West of Uttoxeter

Air Eliminators and Combination Air Eliminators Strainers

Exploration for natural gas

Outlet stabilization structure

Confined spaces. You might go into a confined space to inspect, test, repair, for maintenance or cleaning.

Transcription:

An applicants guide to water supply boreholes Version 1 May 2010 SEPA acknowledges the use of material from the Environment Agency to produce parts of this document.

1. Introduction This guide provides general advice to people wishing to construct groundwater abstraction boreholes. It outlines what authorisation is required, how to conduct a water features survey, if required, and best practice for borehole location and construction. 2. Authorisation 2.1 Do I require SEPA authorisation to construct and abstract water from a borehole? The Water Environment (Controlled Activities) (Scotland) Regulations 2005 (CAR) require that groundwater abstractions be authorised either by general binding rules, registration or licence. Details of what level of authorisation is required for different types and scales of activities are provided in the Controlled Activities Regulations: A practical guide. CAR application forms can be found on the SEPA website. 2.2 Do I require any other authorisation? If your borehole is over 15m deep then you must give prior notification to the British Geological Survey and give your records to them once drilling is complete. If your borehole is within a mining area you will need approval from the Coal Authority to drill in the coal measures. 3. Water features survey 3.1 Do I need to carry out a water features survey? You need to provide SEPA with information so that it can make an assessment of the impact that your abstraction will have on the water environment. For abstractions of groundwater greater than 50m 3 /d your application needs to be accompanied by a water features survey and that forms part of the information required for that assessment. This will enable SEPA to identify all the water features which your abstraction may affect. 3.2 How do I complete a water features survey? To complete the water features survey any of the water features listed in Annex 2 which are present within, or intersected by, a circle of radius specified in Table 1 should be detailed on the water feature survey identification form (WAT-FORM-10) and identified on an up-to-date map of convenient scale, preferably one based on the Ordnance Survey Landplan 1:10 000 series. A walk-over survey is required to identify some of the water features including wetlands. Guidance on how to complete the survey for wetlands is included in Annex 2. Some of the features can be identified by using local knowledge and maps. Some organisations, such as Scottish Natural Heritage, may have relevant information, and some useful addresses are given in Annex 3. Table 1: Radius of survey for water features Abstraction rate (m 3 /d) Minimum radius (m) 50-500 850 >500 1200 Crown copyright. All rights reserved. SEPA lic. no 100020538 (year produced) 3.3 What precautions should I take? When investigating other water supplies care must be taken to avoid contamination from you or your measuring and monitoring equipment. You must also take care when investigating boreholes and other water features and apply appropriate health and safety precautions. An applicants guide to water supply boreholes 2

4. Borehole location and construction 4.1 How do I find out if I will get the quantity and the quality of water I need from my borehole? Hydrogeological consultants, some experienced well drillers and the British Geological Survey may be able to help provide information. A fee may be charged. 4.2 Where should I locate my borehole? To avoid pollution of your borehole it should be located away (up slope and at least 50m) from sources of contamination such as septic tanks, poorly drained areas which receive contaminated run-off and slurry pits. To avoid any reduction in stream or spring flow, or water level in nearby wetlands and other abstractions, and to avoid pulling in seawater into the aquifer, your borehole should be located as far as possible from the coast, and any wetland, steam/river, spring and other abstractions. Borehole A is close to a slurry pit and chemical tank. Borehole B is close to a septic tank soakaway. Both are being contaminated. Annex 1 provides further information on borehole best practice location and construction. A B Boreholes causing intrusion of saline water into the aquifer. 4.3 How do I avoid contamination of my borehole? Poorly constructed not housed/ fenced and poor fitting cap. Following the borehole location guidance above will help prevent contamination of your borehole. However, many boreholes become contaminated as a result of poor construction. Often boreholes are completed below ground in manholes putting them at risk of contaminated run-off directly entering the borehole. To avoid this SEPA recommends that, if possible, boreholes be completed above ground and the casing is adequately grouted. Annex 1 provides further information on borehole best practice location and construction. Care must also be taken when drilling boreholes to avoid contaminating groundwater or nearby rivers, for example, by using inappropriate drilling fluids or poor disposal of drilling fluids. Annex 1 provides some advice on where and how best to construct and complete your borehole. Following these guidelines will help to protect your abstraction from pollution and minimise the risk of having to re-locate or retrofit your borehole following completion. Well constructed borehole housed, good fitting cap An applicants guide to water supply boreholes 3

Annex 1. Best practice borehole location and construction Table 2: Best practice borehole location and construction Location Water well drilling Permanent casing: type Permanent casing: material Permanent casing: jointing Permanent casing: diameter Permanent casing: depth Flange/ seals Good practice Bad practice Objectives Remote from (at least 50m) and up-slope of any pollution sources. As far as possible from wetlands, springs, abstractions and the coast (you may be required to undertake further investigation if there are any abstractions or water dependant wetlands within the radius of the water features survey (WFS) specified in Table 2). Drilling fluids should be free from contaminants and, as far as practical, be limited to clean water, air and approved foaming agents. British Standard, oil industry (API) standard or waterwell standard casing 2. Steel 3 /waterwell grade plastic. Welded, screwed and socketed. Large enough to allow installation of dip tube(s) as well as rising main and power cable. Small enough to provide an annulus of at least 50mm to allow effective pressure grouting 4. Normally to penetrate unconsolidated materials and inserted at least 3m into solid rock. A greater depth may be necessary to seal off unstable or contaminated ground or different aquifer units 5. Threaded joint. Square-cut casing, welded flange. Flange and bolted borehole cap with neoprene seal 6. At low points where contaminated drainage can collect. Close to or down slope of sources of pollution eg fuel/chemical tanks, storage/handling areas, septic tanks. Close to another abstraction borehole 1, groundwater dependant wetland or coast. Use of potentially contaminated equipment, eg may have been used to drill boreholes on contaminated sites or has been lying on ground occupied by livestock. Drainage or sewer pipes. Plastic casing if installed in holes which may be liable to collapse. Push-fit. Too small to allow installation of dip tube(s). Too large to allow effective pressure grouting of annulus between casing and borehole wall. Casing too shallow so that ingress of water from contaminated horizons occurs. No seal/flange plate/rough cut casing. Cut off too close to base of chamber. To minimise the risk of pollution to the abstraction 1. To minimise unacceptable impacts on the environment and other water users. To minimise the risk of contaminants being introduced by the drilling equipment or fluids. To seal off shallow, unstable or contaminated ground. To seal off and to prevent tracking shallow groundwater and surface water via the borehole to the water table. To prevent interconnection of different aquifer layers. To prevent uncontrolled artesian discharges. 1 The Environmental Health Department of the local authority has responsibility for checking the quality of private water supplies, and has powers to condemn sources unfit for human consumption. 2 The casing strength should be designed to suit the ground conditions and installation depth. 3 Steel is more rigid, robust and does not bend. 4 Requires a large enough diameter borehole from the outset. Reductions may be necessary because of unstable ground. 5 Additional secondary casing or a slotted screen with or without a gravel pack may be required in unconsolidated aquifers or unstable ground. 6 Essential if the borehole is artesian. An applicants guide to water supply boreholes 4

Table 2: Best practice borehole location and construction (continued) Grouting Good practice Bad practice Objectives Pressure grouted from base of permanent casing up to surface. Allow minimum of 24 hours for grout to set before drilling deeper. Minimum annulus 38mm. Completion Above ground either in a pump house or protected area not subject to traffic. Manhole: Concrete, 150mm thick. chamber 8 \base Grout poured form surface. Casing just driven not grouted. Drilling recommended before grout has set and hardened 7. Below ground, and not sealed. Concrete <100mm or natural ground. To seal off and prevent tracking of contaminated shallow groundwater and surface water via the borehole to the water table. To prevent water or contaminated drainage accumulation in the manhole chamber, by minimising water entry and providing drainage out of the manhole chamber. Manhole: sides Precast concrete sections, engineering brick or waterproof rendered brick/blockwork (bonded to base). Brick or blockwork, not waterproofed. Manhole: cover Load bearing to suit traffic. Cover frame haunched and bonded to sides. Water-tight seal. Lightweight cover (potentially damaged by traffic). Frame not sealed to sides. Manhole: drain 25mm ID min diameter with vermin screen, leading to surface outlet or effective soakway 9. No drain, no soakaway, blocked drain or manhole constructed below the water table or in waterlogged or poorly drained ground. Manhole: chamber backfill Low permeability material such as clay. High porosity material in waterlogged and poorly drained ground. Dip tubes 10 25mm ID min. dia. Bottom 3m perforated at 100mm centres. Base with plug/bar to prevent dipper running out of dip tube. Bottom at least 2m below the pump intake level or sufficiently below water table to accommodate future changes in water level (pumping and natural). Removable plug in top. None provided. Not deep enough. Open ended (allows dipper to run out of bottom). Not perforated. Safe access to allow reliable water level measurement. Prevent splashing/high level seepages giving spurious readings. Sealed to prevent contamination of borehole, artesian discharge or gas escape as appropriate. A dip tube is a standard condition of a groundwater abstraction licence. 7 Many boreholes have been found to have a cavity at the base of the permanent casing. This is likely to be due to poor grouting or not drilling deeply enough into solid ground before inserting the permanent casing. 8 Where an above ground completion is not possible. 9 A soakaway will not work effectively if the manhole chamber is constructed in low permeability ground or below the water table. 10 Two dip tubes should be considered where water level measurement is to be by manual dip meter and data logger. An applicants guide to water supply boreholes 5

Table 2: Best practice borehole location and construction (continued) Venting Flow meter and sample tap BH Log Good practice Bad practice Objectives Either totally sealed system for artesian boreholes or manhole chamber/building and storage vessels vented according to guidance from HSE 11. Borehole completed above ground or in an open atmosphere. Flow meter should be accurate, located close to the source, away from the pump, not to be bypassed. Well maintained. Sample taps should be located close to the source and prior to any treatment. Geological log using BS5930 method and details of construction. Siting in a building or a chamber which would constitute a confined space. Potential source of ignition from electrical equipment (including switchgear and lights) close to borehole or in a confined space (where there is a risk of gas accumulation). Flow meter fitted on short pipe runs, close to bends and valves. Sample taps placed after treatment. No records of geology or borehole construction. To avoid risk of accumulation of toxic or explosive gases in borehole chamber storage vessels or buildings 12. Where required by SEPA a meter should be calibrated, installed and maintained to ensure accurate measurement of abstraction quantities. A sample tap allows samples to be undertaken and is a standard condition of a SEPA abstraction licence. Aids future maintenance. Aids SEPA in regulatory duties to protect resource in future. 11 Health & Safety Executive Water Boreholes Potential Hazard from Methane Evolution HSE 847/4 July 1990. If a methane problem is envisaged the HSE should be contacted for advice. 12 Methane can be found naturally or be derived from landfills or other sources. Hydrogen sulphide and carbon dioxide can be emitted naturally. These pose a potential hazard where access is necessary into a confined space. An applicants guide to water supply boreholes 6

Below ground completion acceptable good practice (only where an above ground completion is impractical) An applicants guide to water supply boreholes 7

Above ground completion recommended good practice An applicants guide to water supply boreholes 8

Below ground completion example of bad practice An applicants guide to water supply boreholes 9

Annex 2. Water features to be identified Table 3: Water features to be identified within the radius of the water features survey Water features to be identified if within radius of water feature survey 1. Rivers, burns or streams (including river control structures, ie weirs, locks, sluices). 2. Lochs, lochans or ponds with a surface area of more than 50m 2 or where their ecology or use could be adversely impacted by the abstraction (including fish farms and water sports areas). 3. Canals, navigation channels or reservoirs. 5. Seepage pits (catchpits for springs). 6. Wetlands. To identify wetlands a site walkover will be necessary. This need not be by someone with professional training at this stage, although further investigations may be necessary. The survey should be completed using wetland typology guidance available on the SNIFFER website. This includes guidance on how to complete a walkover survey and identify general wetland types. 7. Coastlines and coastal lagoons. 8. Areas of saline or areas of potentially contaminated groundwater. 9. Boreholes and wells, specifying use and construction details. 10. Surface water and groundwater abstractions. 11. Springs and seepages. 12. Large discharges to surface waters (eg water utility water treatment works). An applicants guide to water supply boreholes 10

Annex 3. Contact names and addresses Local authorities Your local authority may keep a register of all households that are not on public mains supply and will have a register of some abstractions of less than 10 m 3 /day. They may also hold information on local and UK biodiversity action plans and local conservation areas. Scottish Water Scottish Water holds information on the location of those public water supplies administered by them. Scottish Water PO Box 8855 Edinburgh EH10 6YQ www.scottishwater.co.uk Scottish Natural Heritage (SNH) SNH can supply details of Special Areas of Conservation (SACs), Special Protection Areas (SPAs) and Sites of Special Scientific Interest (SSSIs) that lie within the area of influence of your proposed abstraction. 12 Hope Terrace Edinburgh EH9 2AS www.snh.gov.uk The British Geological Survey (BGS) BGS can supply information concerning the location of some boreholes but, as it is not obligatory to register boreholes less than 50 feet deep, its database is not exhaustive. Murchison House, West Mains Road, Edinburgh EH9 3LA www.bgs.ac.uk The Coal Authority (CA) The CA can supply information on historic coal mining activities that may have resulted in groundwater of poor quality. The Coal Authority 200 Lichfield Lane Mansfield Nottinghamshire NG18 4RG www.coal.gov.uk 0679_AP 05/10 An applicants guide to water supply boreholes 11