Leuze electronic. Hand-held barcode scanner. Dimensioned drawing. Electrical connection



Similar documents
Barcode Reader Series BCL 31, BCL 32, BCL 34

Laser Barcode Scanner

Quick Installation. A Series of Intelligent Bar Code Reader with NeuroFuzzy Decoding. Quick Installation

Bar Code Reader Series BCL 20 A flexible reader for a variety of applications

Laser Barcode Scanner User s Manual

USER'S GUIDE NUSCAN 2100 Series

Industrial Bar Code Scanners

16-Port RS232 to USB2.0 High Speed Multi Serial Adapter (w/ Metal Case) Installation Guide

Metrologic MS1690 2D Scanner Installation Guide

Industrial Bar Code Scanners

ALL-USB-RS422/485. User Manual. USB to Serial Converter RS422/485. ALLNET GmbH Computersysteme Alle Rechte vorbehalten

Manual Serial PCI Cards

Bar Code CCD Scanner OPERATION MANUAL

Bar code scanners CLX49x / CLX490 / Standard Density

Industrial Bar Code Scanners

Application Note. Terminal Server G6

MS9500 SERIES VOYAGER PRODUCT GUIDE. Single Line, Hand-Held, 1D, High-Density 1D, PDF-417 2D and Wireless Laser Bar Code Scanners

HT580 User Reference Guide. Version 1.0

BCST-20 Barcode Scanner. Instruction Manual.

BIT COMMANDER. Serial RS232 / RS485 to Ethernet Converter

Bar code scanners CLV45x / CLV450 / Standard Density

CLV 41x Bar Code Scanner Standard line

RS - SPM. Serial parallel translator module

PCS0100en Persy Control Services B.V. Netherlands

CENTRONICS interface and Parallel Printer Port LPT

A RF18 Remote control receiver MODULE

Programmable set for Ethernet Modbus/TCP in IP67 TI-BL67-PG-EN-2

because we care MS910 Wireless Barcode Scanner Quick Guide Full user s manual is available on the enclosed CD. Version G

Laser Scanner Programming Guide (SE923 laser engine)

Modification of an AOR AR-8600 receiver to tune it with a ACECO FC-3002 frequency finder

Bluetooth HC-06 with serial port module Easy guide

FACTORY AUTOMATION LASER BARCODE SCANNERS FOR INDUSTRIAL AUTOMATION

DUET / VS800 Scanner. DUET Scanner VS800 Scanner. Programming Kit

Wi-Fi Barcode Scanner

Combi switchbox with integrated 3/2 way pilot valve

Technical data. General specifications. Signal voltage V DC Signal duration. 1 s Input 2. Signal voltage. 1 s Analog output.

Technical data. General specifications. Indicators/operating means. 30 Hz Multiplex operation 30 Hz / n, n = number of sensors, n 5

KSH-3000-MI. Swipe Card Reader. ( Magnetic / IC Card two in One Reader ) Revision Reason Date V

Industrial Bar Code Scanners

Wireless Laser Barcode Scanner ils 6300BU. User s Manual

HSP GmbH Zum Handwerkerhof Wendelstein Tel / Fax: / Web: HSP@hsshsp.de NTG-3000.

Bluetooth to Serial Adapter

2-Port RS232/422/485 Combo Serial to USB2.0 Adapter (w/ Metal Case and Screw Lock Mechanism) Installation Guide

Xi2000 Series Configuration Guide

Throughbeam photoelectric sensors. Dimensioned drawing. Electrical connection

Application/Connection Examples

MCB3101 (Class I) WiRobot Serial Bluetooth Wireless Module User Manual

1 Serial RS232 to Ethernet Adapter Installation Guide

Scanner Configuration

Advanced Data Capture and Control Systems

1-Port R422/485 Serial PCIe Card

User Manual. AS-Interface Programmer

LED red (-): Measuring value < lower tolerance threshold LED red (+): Measuring value > upper tolerance threshold. Page 1/6

CNC File Transfer Box. Connecting the CNC File Transfer. CNC Transfer Program

Wireless Scanner. User s Manual - MS910 - Version 1.0

TMCT-10 Barcode Scanner User Manual. 102, St. Edmonton, AB T6E 3N8 Ph Fax

Series 6000 Torque measured metal bellow coupling

SG20T. Tethered Scanner. User s Guide

1 Technical Description Lokal-200PC

NOTICE: respective owner. Note: Specification is subject to changes without. notice.

connecdim Gateway G1 Ethernet TCP/IP to DALI

NC-12 Modbus Application

M3 ORANGE Snap-On. User Guide. Product Model: A-SNO-ATYP-060-R00. Compatible Device: M3 ORANGE. Version 2.2 Released in March 2013

Programmable set for Ethernet Modbus/TCP in IP20 TI-BL20-PG-EN-8

HCS-3300/3302/3304 USB Remote Programmable Laboratory Grade Switching Mode Power Supply

SPID Azimuth Antenna rotator Type: BIG-RAK/HR

QUICK START GUIDE Bluetooth Cordless Hand Scanner (CHS)

Barcode Positioning System BPS 8

Laser diffuse reflection light scanner with background suppression. Dimensioned drawing

Index...1. Introduction...3. Installation- Keyboard Wedge...3 RS USB...3. Default Setting for each barcode shown as below:...

DK40 Datasheet & Hardware manual Version 2

OPTICAL HEADEND PLATFORM OTOHP-NMS NETWORK MONITORING MODULE INSTRUCTION MANUAL

METROLOGIC INSTRUMENTS, INC. IS4225 ScanGlove USB Addendum for the MetroSelect Single-Line Configuration Guide

Automation System TROVIS 6400 TROVIS 6493 Compact Controller

AC-115 Compact Networked Single Door Controller. Installation and User Manual

RS232 Programming and Troubleshooting Guide for Turbo Controls

M72. Quectel Cellular Engine. EVB User Guide M72_EVB_UGD_V1.0

HAC-LM Series Low Power Data Radio Module

HANDHELD LASER SCANNER

XR-500 [Receipt Printer User s Manual ]

Options for ABB drives, converters and inverters. User s manual FDPI-02 diagnostics and panel interface

ELAN DIGITAL SYSTEMS LTD. SL232 PC- CARD USER S GUIDE

Z-1170BT V2 ( Version 1.01) User s Manual

is then retained absolutely without interruption.

Industrial RS-232/ RS-422/ RS-485 over Ethernet Media Converter

Barcode Magstripe. Decoder & Scanner. Programming Manual

RN-XV-RD2 Evaluation Board

Sturdy aluminium housing, anodized in blue Female connector for optical fiber (please order optical fiber separately) Mounting holes

CAT5 KVM Extender User Manual

Arduino Wifi shield And reciever. 5V adapter. Connecting wifi module on shield: Make sure the wifi unit is connected the following way on the shield:

Synergy Controller Application Note 4 March 2012, Revision F Tidal Engineering Corporation Synergy Controller Bar Code Reader Applications

Technical Data. back-up time in minutes 100% load % load

Series LC6D/LC6C. To power supply PLC. LC6C dedicated teaching box P.971. Options P.973

1 Safety instructions. 2 Device components. Facility Pilot Server. Art. No. : FAPV-SERVER-REG Art. No. : FAPVSERVERREGGB. Operating instructions

TP32MTT.03 TP32MTT [ GB ] Probes for soil thermal profile measurement

Mobile POS Tablet Barcode Scanner

CLV440/442 Bar Code Scanner

STIM202 Evaluation Kit

Programming and Using the Courier V.Everything Modem for Remote Operation of DDF6000

Transcription:

Hand-held barcode scanner Dimensioned drawing Part No. 501 07087 4,5-12 V DC We reserve the right to make changes BP_IT3800g_gb.fm Hand-held scanner for barcodes Large reading field for the detection of codes Robust trigger button Built-in decoder Read-display TTL-RS 232, USB and PS/2 interface Operating temperature from 0 through 50 C Protection class IP 41 Accessories TTL-RS 232-cable/ext for IT 4xxx Part No. 501 04442 TTL-RS 232-cable/PIN 9 for IT 4xxx Part No. 501 04586 PS/2-cable for IT 4xxx Part No. 501 03409 USB-cable for IT 4xxx Part No. 501 03404 Power supply unit for IT 4xxx Part No. 501 03403 Support for Part No. 501 07039 Electrical connection for RS 232 cable / ext. 9-pin Sub-D Signal Connection for power supply unit RJ41 SH Shield SH 2 2 TXD 6 3 RXD 5 5 GND 1 4 7 CTS 9 8 RTS 8 5VDC 2 7 for RS 232 cable / PIN 9 9-pin Sub-D Signal RJ41 SH Shield 2 2 TXD 6 3 RXD 5 5 GND 4 7 CTS 9 8 RTS 8 9 5VDC 7 for USB cable USB type A Signal RJ41 1 5VDC 7 + 3 2 Data - 10 3 Data + 2 4 GND 4 for PS/2 cable Mini DIN connector Mini DIN socket Signal RJ41 1 - PC Data 6 2 2 NC 3 3 GND 4 4 4 5VDC 7 5 - PC Clock 5 6 6 NC - 1 KB Data 8-5 KB Clock 9 Leuze electronic GmbH + Co. KG Post-box 1111 D-73277 Owen-Teck Tel. +49 7021 5730 www.leuze.de - 02

Specifications Electrical data Operating voltage U B Power consumption 4.5 12VDC max. 1.8W Interfaces Interface type TTL-RS 232, PS/2 and USB Trigger via button Code types Bar codes 2/5 Interleaved, Code 39, Code 128, Code 93, Codabar, UPC/EAN, RSS, Codablock Optical data Optical system 3648 linear Imager Contrast 20% (black/white) Light source integrated diffuse LED 630nm Read distance 13 460mm (UPC 100%) Read angle various tilt and rotational angles up to 65 Mechanical data Housing UL94V0 grade Weight 159g (without cable) Dimensions 150x112x79mm Shock resistance 50 falls from a height of 1.5m Environmental data Ambient temp. (operation) -0 C +50 C Ambient temp. (storage) -40 C +60 C Relative air humidity 0 95% (non-condensing) Protection class IP 41 Reading field Tables Diagrams Module or cell from to Bar codes 5mil / 0.127mm 50mm 200mm 7.5mil / 0.19mm 40mm 300mm 10mil / 0.25mm 30mm 380mm 13mil / 0.33mm 10mm 460mm 15mil / 0.38mm 30mm 560mm 20mil / 0.5mm 30mm 660mm Order guide Hand-held scanner for barcodes (standard range) Part No. 15E with TTL-RS 232, KBW and USB interface 501 07041 Remarks Ergonomically shaped handheld scanner with integrated decoder for barcodes. Data transmission via configurable RS 232 interface. Or keyboard-wedge operation via PS/2 or USB interface. - 02 0705

Hand-held barcode scanner Switching off the computer Information on switching off and shutting down the connected computer - which must always be performed before connecting peripheral devices, such as a scanner - can be found in the appropriate operating instructions for your computer. Connecting the IT 3800 Shown in the adjacent figure are the individual steps for installing the cable on the scanner; these steps are described in the following. 1.To secure the interface cable to the scanner, proceed as follows: plug the RJ 41 connector into the socket on the bottom of the hand-held scanner. 2.Connect the interface cable to the appropriate connection socket on the computer. 3.You may need a power supply unit for supplying voltage; alternatively, you can use a cable which supplies voltage from the computer system. Use the pin assignments (see "Electrical connection" on page 1) to select the appropriate cable for your application. 4.Connect the power supply unit to the power socket (not necessary if voltage is supplied from the computer). 5.Use the code for the respective application to configure the hand-held scanner, see chapter "Configuration". 6.Check the operational readiness of the scanner by pointing the scanning surface towards a flat surface and pulling the trigger. A red target line should now be visible. Now scan a sample label. The scanner emits an audible signal to confirm that the label has been read; if necessary, the data are now passed on to the computer. Cable latch Configuration The hand-held scanner can always be configured using bar codes. To do this, the barcode must first be selected on the package insert and then the trigger actuated in order to read the code. The configuration is then immediately accepted and executed. Several of the most important configurations are listed in the following. A second option is to configure the hand-held scanner with the USB and RS 232 interfaces with the aid of the VisualMenu PC program. You can download and install this program from our homepage at www.leuze.de. The program can be used to make settings and transfer them to the hand-held scanner. The configuration can also be stored so that it can be reused at a later time. Further information on this can be found in the User's Guide for the. The standard applications are described and summarised below. Notice! Additional information on the device and short instructions can be found on the Internet at www.leuze.de. Resetting the to factory settings To reset all parameters to factory settings, scan the adjacent barcode. Attention! All settings are lost!!! You may then continue making settings or operation of the device. Leuze electronic GmbH + Co. KG Post-box 1111 D-73277 Owen-Teck Tel. +49 7021 5730-02 www.leuze.de

Trigger Leuze electronic To activate the read process, a trigger signal is to be sent via the serial RS 232 interface or USB interface (COM port emulation only). The command is to be sent at the set baud rate, parity, and data and stop bits. The command for activation is: SYN T CR ASCII decimal values: 022; 084; 013 To cancel read readiness, send a deactivation. The command for deactivation is: SYN U CR ASCII decimal values: 022; 085; 013 Following a successful read operation, the deactivates itself. The second option is activation via the built-in trigger button. Configuration for the Leuze standard protocol To set the Leuze standard protocol, you must first reset the scanner to factory settings and then individually define each of the transmission parameters using a barcode 1.Scan the adjacent barcode. The is reset to factory settings. 2.Successively scan the 4 barcodes shown below. Each read operation is confirmed by a beep. The is set to the following transmission parameters: RS 232 transmission with 9,600 baud, 8 data bits, 1 stop bit, no parity, prefix <STX>, terminators <CR><LF>. 9600 Bd Terminal ID Prefix STX Postfix CR/LF - 02 0705

Hand-held barcode scanner Connecting the to the serial PC interface With voltage supply via PIN 9 with TTL-RS232-cable/PIN9 IT 4xxx Part No. 501 04586 1x 501 07 041 15E 1x 501 04 586 Cable TTL-RS232/PIN9 With voltage supply via power supply unit with cable RS232/ext IT 4xxx Part No. 501 04442 1x 501 07 041 15E 1x 501 04 442 Cable TTL-RS232/ext 1x 501 03 403 Power supply unit 1.Switch off the PC. 2.Connect the interface cable to a free COM port (RS 232) on the computer, to the as well as to the power supply unit. 3.Switch the PC back on. 4.Scan the adjacent barcode. The is set to the following transmission parameters: RS 232 transmission with 38,400 baud, 8 data bits, 1 stop bit, no parity, terminators <CR><LF>. 5.If necessary, adjust the transmission parameters of the used COM port to those of the. Attention! We recommend connecting the directly to a PC or to the MA 21 or MA 41 connector units. If connecting to other components, please note that a voltage level range of -12 +12V is maintained on the data lines! Leuze electronic GmbH + Co. KG Post-box 1111 D-73277 Owen-Teck Tel. +49 7021 5730-02 www.leuze.de

Connecting the to the MA 41 DP-K or MA 41 IS 1x 501 07 041 15E 1x 501 04 442 Cable TTL-RS232/ext 1x 501 03 403 Power supply unit 1x 500 35 421 KB 021 Z 1x 500 33 638 MA 41 DP-K for Profibus (for Interbus: 500 28 994 MA 41 IS or 500 30 085 MA 41 IS PDP) Pin assignments KB 021 Z: Core colour: signal terminal in the MA 41: brown (RXD) 2 white (TXD) 1 blue (GND) 4 red (VCC) black (GND) bare (shield) (PE) 21 1.Connect cable KB 021 Z to the MA 41 acc. to the above pin assignments. 2.Connect the interface cable to cable KB 021 Z. 3.Scan the adjacent barcode. The is reset to factory settings. 4.Successively scan the 3 barcodes shown below. Each read operation is confirmed by a beep. The is set to the following transmission parameters: RS 232 transmission with 9,600 baud, 8 data bits, 1 stop bit, no parity, terminators <CR><LF>. 9600 Bd Terminal ID Postfix CR/LF - 02 0705

Hand-held barcode scanner Connecting the to the MA 21 1x 501 07 041 15E 1x 501 04 586 Cable TTL-RS232/PIN9 1x 500 35 421 KB 021 Z 1x 500 30 481 MA 21 100 Pin assignments KB021 Z: Core colour: signal terminal in the MA 21: brown (RXD) 26 white (TXD) 27 blue (GND) 28 red (VCC) 30 black (GND) 31 bare (shield) (PE) 21 1.Connect cable KB 021 Z to the MA 21 acc. to the above pin assignments. 2.Connect the interface cable to cable KB 021 Z. 3.Scan the adjacent barcode. The is reset to factory settings. 4.Successively scan the 4 barcodes shown below. Each read operation is confirmed by a beep. The is set to the following transmission parameters: RS 232 transmission with 9,600 baud, 7 data bits, 1 stop bit, even parity, terminators <CR><LF>. 9600 Bd Terminal ID 7 data bits, even parity, 1 stop bit Postfix CR/LF Leuze electronic GmbH + Co. KG Post-box 1111 D-73277 Owen-Teck Tel. +49 7021 5730-02 www.leuze.de

Connecting the to the PS/2 interface Leuze electronic The operation of the in keyboard emulation mode is described in this section. A PC keyboard is emulated in this operating mode. The data which are read in are written directly to the currently activated program. Thus, the data can be processed further in all standard programs. 1x 501 07 041 1x 501 03 409 15E PS/2 cable Disconnect 1.Switch off the PC. 2.Disconnect the keyboard. 3.Plug in the hand-held scanner between the keyboard and the PC. 4.Switch the PC back on. 5.Scan the barcodes shown below. IBM PCs and compatible PCs, postfix Keyboard layout for Germany/Austria - 02 0705

Hand-held barcode scanner Connecting the to the USB interface (keyboard emulation) The operation of the in keyboard-emulation mode on a USB port is described in this section. A PC keyboard is emulated in this operating mode. The data which are read in are written directly to the currently activated program. Thus, the data can be processed further in all standard programs. 1x 501 07 041 1x 501 03 404 15E USB cable 1.Plug the hand-held scanner into a free USB port. 2.The scanner acknowledges this connection with a beep. 3.Scan the barcodes shown below. USB keyboard emulation with CR LF Keyboard layout for Germany/Austria Leuze electronic GmbH + Co. KG Post-box 1111 D-73277 Owen-Teck Tel. +49 7021 5730-02 www.leuze.de

Connecting the to the USB interface (COM-port emulation) Leuze electronic The operation of the as a serial interface on a USB port is described in this chapter. A COM interface is emulated in this operating mode. The data which are read in are sent to a new COM interface. The driver with which you emulate this COM interface can be downloaded from our homepage at www.leuze.de. Thus, the data can be processed further in programs which expect data via COM interfaces. 1x 501 07 041 1x 501 03 404 15E USB cable 1.Plug the hand-held scanner into a free USB port. 2.The scanner acknowledges this connection with a beep. 3.Scan the barcode shown below. 4.Install the USB serial driver when you are prompted to do so by Windows. 5.Open a terminal program or your program for the serial interface, select the new COM port, and make the following settings: baud rate 38,400, 8 data bits, 1 stop bit, no parity, terminator <CR>. USB COM-port emulation - 02 0705