A reasonable, new furnace (mid efficiency) has the following electrical requirements:



Similar documents
SmartOnline V 6kVA 4.2kW On-Line Double-Conversion UPS, Extended Run, SNMP, Webcard, 6U Rack/Tower, DB9 Serial, Hardwire

SmartPro 230V 750VA 500W Line-Interactive Sine Wave UPS, SNMP, Webcard, Tower, USB, DB9 Serial

MAJORSINE Power Inverter

SmartPro 230V 3kVA 2.25kW Line-Interactive UPS, Extended Run, SNMP, Webcard, Tower, USB, DB9 Serial

Battery Model: 25 Part Number: Nominal Voltage: 12 volts NSN: Number applied for, product currently available

SmartOnline V 5kVA 4.5kW On-Line Double-Conversion UPS, Extended Run, SNMP, Webcard, 4U Rack/Tower, USB, DB9 Serial

PV (photovoltaic) Basics There are generally two types of PV systems. The first and easiest (though the least flexible) is a grid tie system where

BB800 Off-Grid Solar System

Uninterruptible Power Supply

PC Personal 120V 600VA 375W Standby UPS with Pure Sine Wave Output, Tower, 6 Outlets

SmartOnline Expandable Rack / Tower UPS System Online, double-conversion protection for mission critical applications

User s Manual Before using the inverter, you need to read and save the safety instructions.

BC Pro UPS System Standby UPS System

SmartPro 120V 750VA 600W Line-Interactive Sine Wave UPS, 1U Rackmount, SNMPWEBCARD Option, USB, DB9 Serial

Internet Office 750VA Ultra-compact Standby 120V UPS with USB port

User s Manual AURORA 1.2K/2.2K

Liebert GXT3 Reliable On-Line UPS Protection In A Compact 2U Package 700VA -3000VA

SmartPro 120V 750VA 600W Line-Interactive Sine Wave UPS, SNMP, Webcard, 1U Rack-Mount, USB, DB9 Serial

SmartPro 120V 1kVA 800W Line-Interactive Sine Wave UPS, SNMP, Webcard, 1U Rack, USB, DB9 Serial

SmartPro 120V 2.2kVA 1.92kW Line-Interactive Sine Wave UPS, SNMP, Webcard option, 2U Rack/Tower, LCD, USB, DB9 Serial

Galleon 6-10K Online UPS. Voltronic Power Technology Corporation

TAA-Compliant SmartPro 120V 1kVA.8kW Line-Interactive Sine Wave UPS, SNMP, Webcard, 1U Rack, USB, DB9 Serial

Online UPS. PowerWalker VFI 1000R/1U

XC120 XC180. Owner's Guide Conforms to / Conforme à UL std. 458, Toll Free

Match. GE Digital Energy. Uninterruptible Power Supply VA. Technology for the Digital World. Match UPS. GE Digital Energy.

SmartPro 120V 500VA 300W Line-Interactive UPS, SNMP, Webcard, 1U Rack/Tower, USB, DB9 Serial

Back-UPS 650 VA 120 V with AVR (BX650CI-LM)

SmartPro 100/110/120V 1.5kVA 900W Line-Interactive Sine Wave UPS, Tower, SNMP, Webcard, USB, DB9 Serial

SmartPro 230V 1000VA 900W Line-Interactive Sine Wave UPS, SNMP, Webcard, 2U Rack/Tower, USB, DB9 Serial

Internet Office UPS System Standby UPS for PCs, workstations and more

3U, 2200 VA Audio/Video Pure Sine Wave UPS System

UPS Applications and VRLA Battery Sizing

3000W Power Inverter

Photovoltaic Solar Energy Unit EESFB

Industrial-Grade UPS System Heavy-duty power protection for harsh industrial environments

Model #: SMART2200VS. 2200VA / 2.2kVA line interactive tower UPS. Maintains 120V nominal output over an input range of 79 to 147V

Charger Output AC Ripple Voltage and the affect on VRLA batteries

The Basics of Solar Power for Producing Electricity An excellent place to start for those just beginning. The basics of solar power: 1000 W/m²

HOW TO CORRECTLY CONNECT DEEP CYCLE BATTERIES AND CHOOSE THE RIGHT CABLE SIZING

Solar Powered Wireless Sensors & Instrumentation: Energy Harvesting Technology Reduces Operating Cost at Remote Sites

APC Matrix-UPS 5kVA 208V/240V In 120/208/240V Out

User Manual HomeGrid 3000 Solar Generator

Audio/Video AVR Series UPS - Intelligent Automatic Voltage Regulated Power Management System

POWER PORTABLE GENERATORS POWER. WHEN YOU NEED IT.

OmniVS Series 1500VA Line-Interactive Tower 120V UPS with USB port

Smart Pro Rack/Tower UPS Intelligent, line interactive network power management system

Table Of Contents

TECHNICAL SPECIFICATIONS FOR 1.5 KVA ONLINE UPS

LTR Series Uninterruptible Power Systems 700 VA KVA. General Specification

Model #: SMART2200CRMXL

Diesel Generating Set

Stroom voor elke toepassing

Operating Manual UWAPS-TINY Series

PHOTOVOLTAIC (PV) solar panels. Specification. Electricity - CE & ISO 9000 certified. 83W panel. 180W panel Maximum power:

Internet Office 500VA Tower Standby 120V UPS with USB port

Phase Modular Finally the benefits of Modular ups are for all

HM-W536 Install Guide

User Manual 1K/2K/3K Online UPS

Introduction To Remote (Off-Grid) Power Systems

How To Use A Power Supply Unit (Upu)

Thyristor-controlled power supplies and battery chargers

Your own power station: For continuous power

SUSTAINABLE TECHNOLOGY

32:(5#5$7,1* 4833#USP283#+] 4;33#USP293#+] 3ULPH 113 kva, 90 kw 124 kva, 99 kw 6WDQGE\ 114 kva, 91 kw 125 kva, 100 kw

Manual. Solar Fountain Mobile Phone Charger

Daker DK 1, 2, 3 kva. Manuel d installation Installation manual. Part. LE05334AC-07/13-01 GF

Constant Voltage Charger Selection for VRLA Batteries

NEW APC Smart-UPS. Advanced line interactive power protection for servers and network equipment. The world s most popular network and server UPS.

Effects of AC Ripple Current on VRLA Battery Life. A Technical Note from the Experts in Business-Critical Continuity

Liebert GXT MT+ CX UPS, 1000VA VA Intelligent, Reliable UPS Protection. AC Power for Business-Critical Continuity

XPower 1500 Portable Household Power

(68.52) X. June 2000 Supercedes February xenex CONVENTIONAL FIRE DETECTION & ALARM SYSTEM. we business differently

Air Conditioning Sign-Off Sheet

PowerGem Pro Uninterruptible Power Supply

Battery guide. ResMed Ltd 1 Elizabeth Macarthur Drive Bella Vista NSW 2153 Australia Tel: Fax: ABN

Battery Power Inverters

Specification Requirements DBL 700MX and 1000MX Series UPS

Carefree Sealed Lead Acid (SLA) MSDS

For protection from laptops to high availability facilities - and everything in between - APC is a partner you can count on

Technical specifications. Containerized data centre NTR CDC 40f+

Height w/o Terminals (in)

TOTALLY SOLID STATE NON-DIRECTIONAL RADIO BEACONS khz

Troubleshooting Guide, Freedom and Fleet Power Inverter/Chargers

Ingersoll Rand Providing Customer-Driven Air System Solutions for More Than 100 Years

OUTPUT CABLE CONNECTIONS:

New Deluxe Wall Mounted Heat Pump Series EXTERIOS

INDUSTRIAL DIRECT DRIVEN PISTON COMPRESSORS CL - CH - CK

Smart-UPS APC Smart-UPS 1000VA USB & Serial 230V

Diesel Engine Driven Generators Page 1 of 6

SELECTION GUIDE FIFTH EDITION

HGG-P-9906 GEN BROCH C0469 9/9/09 11:04 AM Page 2 Honda Generators

Power Quality For The Digital Age INVERTING SOLAR POWER A N E N V IRONME N TA L P OT E N T I A L S W HI T E PA PER

AIS 3000 APC AIS kVA 208V w/2 Batt. Module Exp. To 4, Start-Up 5X8, Internal Maintenance Bypass

HAM841K ALARM CONTROL PANEL FOR COMMERCIAL AND RESIDENTIAL SECURITY SYSTEMS

Technical Data. back-up time in minutes 100% load % load

NEWTECH PRO KVA ONLINE UNINTERRUPTIBLE POWER SUPPLY USER MANUAL

DataSafe HX Top Terminated Batteries 6 and 12 Volt HX

MPA-101. WARNING: Improper installation could result in damage to the amplifier and/or speakers. Read all instructions before installation.

Specifications for Volkswagen Industrial Engine

Transcription:

June 2007 Power Backup Systems for Your Home. As promised from a previous safety meeting, a couple of options to protect you home in the event of a power failure. These options are for the most serious, protecting your home in the winter but could be extended for other interests. Two (2) options are available for the average person to assist with power requirements in the event of a brown out or power outage during an Alberta winter. A reasonable, new furnace (mid efficiency) has the following electrical requirements: Purge blower starts to purge fire box: 2.75 Amp @ 120 VAC Furnace starts to heat exchanger 5.0 Amps @ 120 VAC Blower Starts to circulate heat 10+ Amp surge @ 120 Volts Blower and furnace on line 7.2 Amps @ 120 VAC The supply system must be able to handle the 10+ amps @120VAC (1200Watts) surge and supply 900 Watts at a duty cycle of 80% continuous power for the furnace to operate correctly and not to overload the backup system. This is why the 1500W generator or 2000W inverter system The furnace will run for the required time the shutdown normally. When main power is restored switch the alternate power switch back to normal. Option 1 Purchase a 1500 Watt Honda generator. Honda Mdl. EZ1800C $1050 offers good regulation Honda Mdl. EU 2000iC $1699 offers pure sign wave inversion These items can be purchased from Honda Extreme, (Edmonton) Have an electrician wire an alternate source switch at your furnace and alternate power feed from outside. Because the generator is gasoline driven, it will be necessary to locate the generator outside the house when required to operate.

Option 2 Purchase a passive system consisting of storage batteries, sine wave inverter and charging system. Have an electrician wire an alternate source switch at your furnace and alternate power feed from inside the home. Batteries need to be kept approx. room temperature, at least above freezing. The basement or garage would be a good location for batteries / charger /inverter setup. Option 2 offers the possibility to charge the battery / batteries via solar cells on the roof of your home. Minimum cost $800 + Electrical switch and labour Option 2 with one (1) battery should operate your furnace for approx. 5 hours. A home furnace runs approx 15 minutes every 45 minutes. Therefore heating your home for approx 15 hours. Two batteries would double this. Be aware that batteries have a life span and can go bad just sitting. AGM batteries are good for 8 years+. Sine Wave Inverter: Mdl. APS 100012V 2000 Watt pure sine wave inverter $400 US (free shipping) EDX Inc 2016 Corporate Drive Wilmington, NC 28405 Toll Free: 1.866.220.VOLT (8658) E-mail: inquiries@voltageconverters.com High Capacity Charger: 12VDC @ 15 Amp Price $130.00 Available for ChrisMar Batteries (Edmonton)

Storage Batteries: Deep cycle, Mdl. GV-100 $189.00 each 1 required, 2 for longer outages or more power requirements 12VDC, Weight 71 lbs. Life Span 8 years. Non spillable, AGM Deep cycle (Absorbed Glass Mat) UPS batteries Transportable, non hazardous goods Available for ChrisMar Batteries (Edmonton) Extreme Batteries are maintenance-free Absorbed Glass Mat batteries that combine cycling ability with sealed, spill-proof construction. Exceptionally reliable, these 12 volt batteries are very resistant to cold temperatures. With a porous envelope to hold the electrolyte against the cell plates, gases can't escape, making Extremes suited for warm temperature applications as well. Extreme Batteries are ideal for telecommunication sites and remote data collection equipment, as well as providing consistent quality power for UPS and SCADA systems, switch gear and other stand-by applications. Features:. Higher efficiency & charge acceptance - ideal for solar. Resistant to abuse and complete discharges. Can deliver 600+ cycles @ 50%. Non-spillable and non-hazardous goods for easy transportation

Features Specifications Pure Sine Wave Power Inverter Output Wave Form Pure Sine Wave 1000 watts continuous power No-load draw < 1.0 amp 1050 watts (20 min) Harmonic Distortion less then 3% 2000 watts peak power Input voltage range 10-15 VDC Anodized aluminum case provides durability Over voltage shutdown over 15 VDC Built-in Cooling Fan Under voltage shutdown under 10 VDC 120 volt AC outlet Overload shutdown Yes Overload Indicator Thermal shutdown Yes Power ON/OFF Switch Short circuit shutdown Yes Optional Remote Switch AC receptacle Two 3-Prong Efficiency 90% Warranty 1 year Inverter weight Dimensions (W x H x D) Weight 8.8 lbs 16.7 x 3.3 x 9.3 in. 11 lbs.

Generator Type Inverter Maximum AC Output (Watts) 2000 AC Voltage Available 120 Max. Continuous AC Output (Watts) 1600 Max. Rated AC Amperage @ 120 Volts 13.3 Max. Rated AC Amperage @ 240 Volts N/A Frequency (Hertz) 60 Automatic Voltage Regulator std. DC Output (Volts) 12 DC Amperage 8 Engine Type Honda GX100,OHV, Four Stroke Aircooled Horsepower 3.5 Displacement 100 cc Starting System Manual Recoil Low Oil Level Alert System std. Auto-Throttle Eco-throttle std. Remote start capability no Fuel Tank Capacity (litres) 4.1 Transport Wheels N/A Approximate running Time / Tankful 4.0 @ rated load/ 8 @ 25% load (hrs.) Rated Fuel Consumption (litres / hour) 0.97 @ rated load Noise Level (dba) 59 @ rated load/ 54 @ 25% load Overall Dimensions: Length 510 mm (20.1 in.) Width 290 mm (11.4 in.) Height 424 mm (16.7in.) Dry Weight 21.0 kg. (46.3 lb.) Common Duplex 2 A.C. Receptacle Specifications 13.3 amps total Specifications are subject to change without prior notice.

Generator Type Brush Type Maximum AC Output (Watts) 1500 AC Voltage Available 120 Maximum Continuous AC Output (Watts) 1500 Maximum Rated AC Amperage @ 120 12.5 Volts Maximum Rated AC Amperage @ 240 - Volts Frequency (Hertz) 60 Automatic Voltage Regulator Standard DC Output (Volts) - DC Amperage - Engine Type Honda GX160K1 Overhead Valve Four Stroke Air-cooled Horsepower 5.5 Displacement 163 cc Starting System Manual Recoil Low Oil Level Alert System Standard Auto-Throttle - Remote start capability no Fuel Tank Capacity (litres) 3.7 Transport Wheels - Approximate running Time / Tankfull 3.4 @ rated load (hrs.) Rated Fuel Consumption (litres / hour) 1.09 @ rated load Noise Level (dba) 69 @ rated load Overall Dimensions: Length 511 mm (20.1 in.) Width 426 mm (16.8 in.) Height 406 mm (15.9 in.) Dry Weight 31 kg. (68.2 lb.) Common Duplex Receptacle Specifications 12.5 amps / 120 volts continuous is available as combined total from the two common AC receptacles. 12.5 amps is maximum available from a single receptacle.