Online UPS. PowerWalker VFI 1000R/1U



Similar documents
User Manual 1K/2K/3K Online UPS

NEWTECH PRO KVA ONLINE UNINTERRUPTIBLE POWER SUPPLY USER MANUAL

USER MANUAL Online UPS 1K/2K/3K

USER MANUAL Online UPS 1K/2K/3K Rack

ekil 3 KGK tecrübesi olmayan herhangi bir ki i tarafından çalı tırılabilir.

How To Use A Power Supply Unit (Upu)

USER S MANUAL. MaxPower UPS. Uninterruptible Power System 28-2MAXPO0018

Daker DK 1, 2, 3 kva. Manuel d installation Installation manual. Part. LE05334AC-07/13-01 GF

User s Manual AURORA 1.2K/2.2K

Galleon 6-10K Online UPS. Voltronic Power Technology Corporation

USER MANUAL Online UPS 6K/10K RACK

Line Interactive UPS. PowerWalker VI 500T/HID PowerWalker VI 750T/HID PowerWalker VI 1000T/HID PowerWalker VI 1500T/HID.

Line Interactive UPS

Match. GE Digital Energy. Uninterruptible Power Supply VA. Technology for the Digital World. Match UPS. GE Digital Energy.

10000HXL31/15000HXL31/20000HXL31

Uninterruptible Power Supply ERA LED 1.5 ERA LED 2.0 ERA LED 2.6. User s manual

Powerware 5110 UPS User s manual

User s Manual. Professional Rack Mount LCD Series PR1000ELCDRT2U/PR1500ELCDRT2U/ PR2200ELCDRT2U K

User s Manual Before using the inverter, you need to read and save the safety instructions.

Installation and Operation Manual Back-UPS BX800CI-AS/BX1100CI-AS

REGULINE 600VA / 1000VA REGULATOR USER MANUAL

Installation and Operation Back-UPS 1250, 1300, 1500

HP UPS R1500 Generation 3

How To Use A Power Supply Unit (Upland)

Uninterruptible Power Supply

EKOS Cart. Instructions for Use

PowerGem Pro Uninterruptible Power Supply

Technical Data. back-up time in minutes 100% load % load

PC Personal 120V 600VA 375W Standby UPS with Pure Sine Wave Output, Tower, 6 Outlets

Back-UPS Pro 1300/1500 Installation and Operation

LTR Series Uninterruptible Power Systems 700 VA KVA. General Specification

NIKY and NIKY S. UPS SINGLE-PHASE from 600 to 3000 VA GLOBAL SPECIALIST IN ELECTRICAL AND DIGITAL BUILDING INFRASTRUCTURES

Owner s Manual. Not suitable for mobile applications. Important Safety Instructions 2. Quick Installation 3. Basic Operation 4. Storage & Service 7

UPS OPERATING INSTRUCTIONS PROTECT A. PROTECT A. 500 PROTECT A. 700

MAJORSINE Power Inverter

APC Matrix-UPS 5kVA 208V/240V In 120/208/240V Out

Multi DIALOG MDM/MDT. MDM 10-20kVA single/single-phase and three/single-phase MDT 10-80kVA three/three-phase NETWORK RANGE

SmartPro 100/110/120V 1.5kVA 900W Line-Interactive Sine Wave UPS, Tower, SNMP, Webcard, USB, DB9 Serial

User Manual. Hybrid 1KW-5KW INVERTER / CHARGER. Version: 1.1

350, 500, 650 and 1000 MODELS

SmartOnline Expandable Rack / Tower UPS System Online, double-conversion protection for mission critical applications

SmartPro 230V 3kVA 2.25kW Line-Interactive UPS, Extended Run, SNMP, Webcard, Tower, USB, DB9 Serial

SmartOnline V 5kVA 4.5kW On-Line Double-Conversion UPS, Extended Run, SNMP, Webcard, 4U Rack/Tower, USB, DB9 Serial

Operation Manual. Smart-UPS C. Uninterruptible Power Supply. Tower 1000/1500 VA. 120/230 Vac. su0813a

Back-UPS 650 VA 120 V with AVR (BX650CI-LM)

TECHNICAL SPECIFICATIONS FOR 1.5 KVA ONLINE UPS

USER INSTRUCTIONS FOR GET PORTABLE 12k BTU AIR CONDITIONER MODEL No. GPACU12HR

Model #: SMART2200CRMXL

NeTYS PR VA

SmartPro 230V 750VA 500W Line-Interactive Sine Wave UPS, SNMP, Webcard, Tower, USB, DB9 Serial

SmartPro 120V 2.2kVA 1.92kW Line-Interactive Sine Wave UPS, SNMP, Webcard option, 2U Rack/Tower, LCD, USB, DB9 Serial

SmartOnline V 6kVA 4.2kW On-Line Double-Conversion UPS, Extended Run, SNMP, Webcard, 6U Rack/Tower, DB9 Serial, Hardwire

AC-115 Compact Networked Single Door Controller. Installation and User Manual

SmartPro 120V 500VA 300W Line-Interactive UPS, SNMP, Webcard, 1U Rack/Tower, USB, DB9 Serial

LS1024B / LS2024B/ LS3024B. Solar Charge Controller USER MANUAL

SmartPro 120V 750VA 600W Line-Interactive Sine Wave UPS, SNMP, Webcard, 1U Rack-Mount, USB, DB9 Serial

User Manual. English. APC Smart-UPS 500 VA 100 VAC 750 VA 100/120/230 VAC. Tower Uninterruptible Power Supply

OmniVS Series 1500VA Line-Interactive Tower 120V UPS with USB port

RIGOL. Quick Guide. DS1000CA Series Oscilloscope. Aug RIGOL Technologies, Inc.

CAUTION. CAUTION indicates a potentially hazardous situation which, if not avoided, can result in equipment damage and minor or moderate injury.

User Manual. English. APC Smart-UPS 1000/1500 VA 100/120/230 VAC 750/1000XL VA 120/230 VAC. Tower Uninterruptible Power Supply

SNMP Web card. User s Manual. Management Software for Uninterruptible Power Supply Systems

on-line LOCAL AREA NETWORKS (LAN) SERVERS DATA CENTERS internet centers (isp/asp/pop) industrial plcs industrial applications

ADM1TE 5/30A DIN rail single phase two wire energy meter

SmartPro 120V 1kVA 800W Line-Interactive Sine Wave UPS, SNMP, Webcard, 1U Rack, USB, DB9 Serial

BC Pro UPS System Standby UPS System

DRM75A 230V 20/100A DIN rail single phase two wire energy meter

Meaco 30L and Meaco 40L dehumidifier instruction manual

SmartPro 120V 750VA 600W Line-Interactive Sine Wave UPS, 1U Rackmount, SNMPWEBCARD Option, USB, DB9 Serial

UPS-2200R-HH/UPS-2200R-HHIP

Liebert GXT MT+ CX UPS, 1000VA VA Intelligent, Reliable UPS Protection. AC Power for Business-Critical Continuity

700 VA VA UPS. User s and Installation Manual. EMC Statements. FCC Part 15 ICES-003

Keysight N4877A Clock Data Recovery and Demultiplexer 1:2

TAA-Compliant SmartPro 120V 1kVA.8kW Line-Interactive Sine Wave UPS, SNMP, Webcard, 1U Rack, USB, DB9 Serial

Internet Office 500VA Tower Standby 120V UPS with USB port

HCS-3300/3302/3304 USB Remote Programmable Laboratory Grade Switching Mode Power Supply

FRUK19-6K / FRUK19-10K / FRUK19-15K ONLINE-UPS

Portable Air Conditioner

Internet Office 750VA Ultra-compact Standby 120V UPS with USB port

UNINTERRUPTIBLE POWER SUPPLY (UPS)

Smart-UPS APC Smart-UPS 1000VA USB & Serial 230V

YSmart Technology Co.,Ltd

User Manual. English. APC Smart-UPS SC. 1000/1500 VA 110/120/230 Vac. 2U Tower/Rack-Mount Uninterruptible Power Supply

3U, 2200 VA Audio/Video Pure Sine Wave UPS System

Manual for Fire Suppression & Methane Detection System

INSTALLATION GUIDE. Card Reader & Controller with KIM Swipe Reader for Solitaire 850 / 950 / 850L Learnlok PK2930

XC120 XC180. Owner's Guide Conforms to / Conforme à UL std. 458, Toll Free

Residential Gateway (RG) Battery Backup

LOXONE 12 Channel Amplifier

Industrial-Grade UPS System Heavy-duty power protection for harsh industrial environments

Internet Office UPS System Standby UPS for PCs, workstations and more

esata External Storage

Delta UPS - Amplon Family. User Manual. E Series, Single Phase 1/2/3 kva. The power behind competitiveness ON OFF ON LINE

Taurus Super-S3 LCM. Dual-Bay RAID Storage Enclosure for two 3.5-inch Serial ATA Hard Drives. User Manual March 31, 2014 v1.2

TS1200 Intelligent Lead Free Soldering Station. Operation Manual

QuickSpecs. Models HP T1500 UPS JPN/TWN. HP UPS T1000 G2, T1500 G2 Models Overview

HM-W536 Install Guide

3000W Power Inverter

ViewPower. User s Manual. Management Software for Uninterruptible Power Supply Systems

USER MANUAL GEBRUIKSAANWIJZING MODE D'EMPLOI BEDIENUNGSANLEITUNG

Transcription:

Online UPS PowerWalker VFI 1000R/1U Manual Uninterruptible Power Supply System

Table of Contents 1. Important Safety Warning... 1 1-1. Transportation... 1 1-2. Preparation... 1 1-3. Installation... 1 1-4. Operation... 1 1-5. Maintenance, service and faults... 2 2. Installation and setup... 3 2-1. Rear panel view... 3 2-2. Setup the UPS... 4 3-1. Button operation... 6 3-2. LED Indicators... 7 3-3. Audible Alarm... 8

1. Important Safety Warning Please comply with all warnings and operating instructions in this manual strictly. Save this manual properly and read carefully the following instructions before installing the unit. Do not operate this unit before reading through all safety information and operating instructions carefully. 1-1. Transportation Please transport the UPS system only in the original package to protect against shock and impact. 1-2. Preparation Condensation may occur if the UPS system is moved directly from cold to warm environment. The UPS system must be absolutely dry before being installed. Please allow at least two hours for the UPS system to acclimate the environment. Do not install the UPS system near water or in moist environments. Do not install the UPS system where it would be exposed to direct sunlight or near heater. Do not block ventilation holes in the UPS housing. 1-3. Installation Do not connect appliances or devices which would overload the UPS system (e.g. laser printers) to the UPS output sockets. Place cables in such a way that no one can step on or trip over them. Do not connect domestic appliances such as hair dryers to UPS output sockets. The UPS can be operated by any individuals with no previous experience. Connect the UPS system only to an earthed shockproof outlet which must be easily accessible and close to the UPS system. When installing the equipment, it should ensure that the sum of the leakage current of the UPS and the connected devices does not exceed 3.5mA. 1-4. Operation Do not disconnect the mains cable on the UPS system or the building wiring outlet (shockproof socket outlet) during operations since this would cancel the protective earthing of the UPS system and of all connected loads. The UPS system features its own internal current source (batteries). The UPS output sockets or output terminals block may be electrically live even if the UPS system is not connected to the building wiring outlet. Prevent no fluids or other foreign objects from inside of the UPS system. 1

1-5. Maintenance, service and faults The UPS system operates with hazardous voltages. Repairs may be carried out only by qualified maintenance personnel. Caution -risk of electric shock. Even after the unit is disconnected from the mains (building wiring outlet), components inside the UPS system are still connected to the battery and electrically live and dangerous. Before carrying out any kind of service or maintenance, disconnect the batteries and verify that no current is present and no hazardous voltage exists in the terminals of high capability capacitor such as BUS-capacitors. Only persons are adequately familiar with batteries and with the required precautionary measures may replace batteries and supervise operations. Unauthorized persons must be kept well away from the batteries. Caution -risk of electric shock. The battery circuit is not isolated from the input voltage. Hazardous voltages may occur between the battery terminals and the ground. Before touching, please verify that no voltage is present! Batteries may cause electric shock and have a high short-circuit current. Please take the precautionary measures specified below and any other measures necessary when working with batteries: -remove wristwatches, rings and other metal objects -use only tools with insulated grips and handles. When changing batteries, install the same number and same type of batteries. Do not attempt to dispose of batteries by burning them. This could cause battery explosion. Do not open or destroy batteries. Escaping electrolyte can cause injury to the skin and eyes. It may be toxic. Please replace the fuse only with the same type and amperage in order to avoid fire hazards. Do not dismantle the UPS system. 2

2. Installation and setup 2. Installation and setup NOTE: Before installation, please inspect the unit. Be sure that nothing inside the package is damaged. Please keep the original package in a safe place for future use. 2-1. Rear panel view 1K 1KL 1 AC input 2 Output receptacle: connect to mission-critical loads. 3 Programmable outlets: connect to non-critical loads 4 USB/RS-232 serial communication port 5 ROO/RPO function connector 6 SNMP intelligent slot 7 Dry contact 8 External battery connector 3

2-2. Setup the UPS Step 1: UPS input connection Plug the UPS into a two-pole, three-wire, grounded receptacle only. Avoid using extension cords. The power cord is attached to the UPS. The input plug is a NEMA 5-15P. Step 2: UPS output connection There are two kinds of output receptacles: programmable outlets and general outlet. Please connect non-critical devices to the programmable outlets and critical devices to the general outlets. During power failure, you may extend the backup time to critical devices by setting shorter backup time for non-critical devices. Step 3: Communication connection Communication port: USB port RS-232 port Dry contact Intelligent slot To allow for unattended UPS shutdown/start-up and status monitoring, connect the communication cable one end to the USB/RS-232 port and the other to the communication port of your PC. With the monitoring software installed, you can schedule UPS shutdown/start-up and monitor UPS status through PC. The pin assignment for dry contact is listed as below: Condition Pin status Yes No Low battery. Pin 3 and Pin 9 are connected. Pin 3 and Pin 1 are connected. Output is abnormal. Pin 7 and Pin 8 are connected. Pin 7 and Pin 5 are connected. Battery mode. Pin 2 and Pin 6 are connected. Pin 2 and Pin 4 are connected. The UPS is equipped with intelligent slot perfect for SNMP card. When installing with SNMP card in the UPS, it will provide advanced communication and monitoring options. 4

Step 4: Disable/Enable ROO/RPO function Contact open: UPS shuts down. Contact closed: UPS start-up (UPS is connected to AC power and AC power is available). Note: The local ON/OFF control by pressing On/Off button overrides the remote-control function. Contact open: UPS shuts down and Fault LED (3) will be ON. To return to normal operation, de-activate external remote contact (Fault LED (3) will be OFF) and restart the UPS by pressing button. Step 5: Turn on/off the UPS Press the ON/OFF button on the front panel for two seconds to power on the UPS. Step 6: Install software For optimal computer system protection, install UPS monitoring software to fully configure UPS shutdown. You may insert provided CD into CD-ROM to install the monitoring software. If not, please follow steps below to download and install monitoring software from the internet: 1. Go to the website http://www.power-software-download.com 2. Click ViewPower software icon and then choose your required OS to download the software. 3. Follow the on-screen instructions to install the software. 4. When your computer restarts, the monitoring software will appear as an orange plug icon located in the system tray, near the clock. 5

3. Operations 3-1. Button operation 1K View: LED indicators On/Off button Button ON/OFF Button Function Turn on the UPS: Press and hold button for at least 2 seconds to turn on the UPS. Turn off the UPS: Press and hold this button at least 2 seconds to turn off the UPS. UPS will be in standby mode when utility power is normal or transfer to bypass mode if bypass mode is enabled via software. 1KL View: Button ON/Mute Button OFF/Enter Button Function Turn on the UPS: Press and hold ON/Mute button for at least 2 seconds to turn on the UPS. Mute the alarm: When the UPS is on battery mode, press and hold this button for at least 5 seconds to disable or enable the alarm system. But it s not applied to the situations when warnings or errors occur. Turn off the UPS: Press and hold this button at least 2 seconds to turn off the UPS in battery mode. UPS will be in standby mode under power normal or transfer to Bypass mode if the Bypass enable setting by pressing this button. 6

3-2. LED Indicators 1K View: UPS Status LED Color Lighting/Flashing LED1 Green Lighting LED4 to LED7 indicate load level during line mode. Line Mode LED4: > 75% load level LED5: 50% ~ 75% load level Green Lighting LED6: 25% ~ 50% load level LED7: 0% ~25% load level LED2 Yellow Flashing LED4 to LED7 indicate battery capacity during battery mode. Battery Mode LED4: battery voltage > 26V LED5: battery voltage > 24.5V Green Lighting LED6: battery voltage > 23V LED7: battery voltage > 21V Low battery LED7 Green Flashing Battery replacement LED3 Red Flashing Fault LED3 Red Lighting 7

1KL View: Three indicators to display UPS status: UPS Status Indicators AC Mode Green LED lighting. Battery Mode Yellow LED flashing. Fault Red LED lighting. Off-mode charging. Green LED flashing. 3-3. Audible Alarm Battery Mode Low Battery Overload Fault Bypass Mode Sounding every 4 seconds Sounding every second Sounding twice every second Continuously sounding Sounding every 10 seconds 8

4. Troubleshooting If the UPS system does not operate correctly, please solve the problem by using the table below. Symptom Possible cause Remedy No indication and alarm even though the mains is normal. The alarm is sounding twice every second. The AC input power is not connected well. The AC input is connected to the UPS output. UPS is overload After repetitive overloads, the UPS is locked in the Bypass mode. Connected devices are fed directly by the mains. Check if input power cord firmly connected to the mains. Plug AC input power cord to AC input correctly. Remove excess loads from UPS output. Remove excess loads from UPS output first. Then, shut down the UPS and restart it. 5. Storage and Maintenance Operation The UPS system contains no user-serviceable parts. If the battery service life (3~5 years at 25 C ambient temperature) has been exceeded, the batteries must be replaced. In this case, please contact your dealer. Storage Before storing, charge the UPS 5 hours. Store the UPS covered and upright in a cool, dry location. During storage, recharge the battery in accordance with the following table: Storage Temperature Recharge Frequency Charging Duration -25 C -40 C Every 3 months 1-2 hours 40 C -45 C Every 2 months 1-2 hours 9

6. Specifications MODEL 1K 1KL* CAPACITY INPUT Voltage Range Frequency Range Phase Power Factor OUTPUT Output voltage 1000 VA / 800 W 80VAC/70VAC/60VAC/55VAC ± 5 % or 160VAC/140VAC/120VAC/110VAC ± 5 Low Line Transfer % ( based on load percentage 100% -80 % / 80 % -70 % / 70-60 % / 60 % -0) 85VAC/75VAC/65VAC/60VAC ± 5 % or 170VAC/150VAC/130VAC/120VAC ± 5 Low Line Comeback % ( based on load percentage 100% -80 % / 80 % -70 % / 70-60 % / 60 % -0) High Line Transfer 150 VAC ± 5 % or 300 VAC ± 5 % High Line Comeback 140 VAC ± 5 % or 290 VAC ± 5 % 40Hz ~ 70 Hz Single phase with ground 0.99 @ Nominal voltage (full load) 110/120 VAC or 220/230/240 VAC AC Voltage Regulation ± 1% Frequency Range Frequency Range (Bat. Mode) Overload Current Crest Ratio Harmonic Distortion AC Mode to Bat Transfer Mode Time Inverter to Bypass Waveform (Bat Mode) EFFICICY AC Mode Battery Mode BATTERY 57 ~ 63 Hz (Synchronized Range) 60Hz ± 0.3 Hz 100%~105%: audible warning /105%-130%: UPS shuts down in 10 seconds at battery mode or transfers to bypass mode after 2min when the utility is normal. >130%: UPS shuts down immediately at battery mode or transfer to bypass mode after 10s when the utility is normal. 5:1 for 110/120 VAC system or 3:1 for 220/230/240 VAC systems 3 % THD (Linear Load) 5 % THD (Non-linear Load) Zero 4 ms (Typical) Pure Sinewave ~ 86% @ 100% load ~ 83% @ 100% load Battery Type 6 V / 7 AH Lithium-iron battery or Sealed Numbers 4 Lead-acid battery (Battery voltage: Recharge Time 4 hours recover to 90% capacity 48VDC) PHYSICAL Dimension, D X W X H (mm) 477 x 438 x 44 300 x 440 x 44 Net Weight (kg) 12.6 6 VIRONMT Operation Humidity Noise Level MANAGEMT USB/RS-232 20-90 % RH @ 0-40 C (non-condensing) Less than 50dBA @ 1 Meter Supports Windows 2000/2003/XP/Vista/2008/7/8, Linux, Unix and MAC Optional SNMP Power management from SNMP manager and web browser *1KL is only available in 220/230/240VAC system. 10