IQ8Quad Ex (i) Explosion-proof series



Similar documents
Analogue addressable devices

Isolating Barriers for our sensors A5S1 in Ex-areas Series D461

Ammeter / Voltmeter Series 8402, 8403, 8405, 8404

Ammeter / Voltmeter Series 8402, 8403, 8405, 8404

HERZ-Thermal Actuators

Ferrostat Speed Sensor Series DSF Explosion Proof Versions EEx

2.12. page Products for Explosion hazardous Environment

Terminal Boxes in Glass Fiber Reinforced Polyester (GRP)

AS-i 3.0 PROFIBUS Gateways with integrated Safety Monitor

Flameproof Audible Signal 115 db (A) Series YA90

Control- and feedback head for integrated mounting on Robolux valves Type 2036

Inductive sensor NI10-M18-Y1X-H1141

AS-i 3.0 Gateways, PROFIsafe via PROFIBUS or PROFINET

Threaded Resistance Thermometers Model TR10-D, Miniature Design

Technical Data. Dimensions

Series 8146/5-V37 and Series 8150/5-V37

A good connection. International approvals.

Fire alarm system EBL512 G3

PLUGS & RECEPTACLES. INNOVATIVE EXPLOSION PROTECTION by R. STAHL

INTELLIGENT MONITORING FOR SAFER BUSINESS

7 Lighting Technology

Redundancy Module QUINT-DIODE/40

Technical data sheet TDS0070

Technical Data. General specifications Switching element function Rated operating distance s n 15 mm

Plug and Socket Devices CES 63 A Series 8579

AS-i 3.0 Gateways, PROFIsafe via PROFINET or PROFIBUS

Level Switch LBFS. Technical Data. ATEX data Internal inductivity Li < 10 μh Internal capacity Ci < 43 nf Barrier data. Sensor

Product Information Fire alarm panel 8000 C

Technical Information RIA14

Air Sensor. SAC Ex. Manual ATEX. AQ Elteknik AB

R4D0-FB-IA* FieldBarrier. Features. Assembly. Function. Connection IN + - S OUT Spur 2. Spur 1. Zone 1. Zone 0

Explosion proof enclosures

Linear Luminaire with LED Series EXLUX 6402/2

Cross-beam scanning system to detect slim objects. 100 mm in

Terminal Boxes Series 8146

Actuator-Sensor-Interface

TYPE 65UV CEX Integrated Flame Scanner with Internal Flame Relay and Analog Output

H/L = Power supply. FN = Nominal Frequency. RN = Rated value of output burden. UN = Nominal input voltage. IN = Nominal input current.

DLO1191 Linear smoke detector

Plug and Socket Devices SolConeX 16 A Series 8570

PD30ETB20xxIS. Photoelectrics, Background Suppression reflective with IR light. Main features. Description

Digital input modules

Solenoid Valve Island Type 3965

MLC TM Maximum Productivity and Versatility for Control without Compromise!

Fire & Security DETECTORS

CONTROLS DATA MANAGEMENT PROCESS AUTOMATION EUROCUBE. General purpose single phase thyristors and solid state relays Product data.

ISIO 200. Binary Input/Output (I/O) Terminal with IEC Interface

RM4TG20 three-phase network control relay RM4-T - range V

Technical Data. General specifications Switching element function Rated operating distance s n 5 mm

Detector transparent with Color Inserts. FAA 500 TR P Trim Ring transparent with Color Inserts. FCA 500 / FCA 500 E Detector Bases

CB Zone Conventional Control Panel

3500/62 Process Variable Monitor

ABB i-bus KNX Fan Coil Actuator, MDRC FCA/S 1.1M, 2CDG R0011

Triple Waveband Infra-Red Flame Detection

STEP-PS/1AC/12DC/1.5. Extract from the online catalog. Order No.: DIN rail power supply unit 12 V DC/1.5 A, primary switched-mode, 1- phase

Magnetic field sensor for pneumatic cylinders BIM-INT-Y1X-H1141

How To Control A Power Supply With A Mini Transmitter And Switch (Power Supply)

SINEAX U553 Transducer for AC Voltage

Technical Data. General specifications Switching element function Rated operating distance s n 5 mm

RM17TE V AC. Main. Product or component type. Product specific application. Relay monitored parameters 250 V DC 5 A DC

MINERVA MX MX Virtual Multi-Sensor Detectors

Input module, input/output module

Adjustment functions for both span and shift have been incorporated

3/2-, 5/2- and 5/3-way Solenoid Valves for process pneumatics

TX OPEN RS232/485 module

Smoke exhaust systems

Digital Pressure Measuring Instrument MDR480

Advanced Intelligent Modules. Overview. Description

SYSTEM DESCRIPTION Termination Boards

CAPACITIVE LEVEL METERS CLM 36

ALARMLINE ANALOGUE Linear Heat Detection System

Flow switches Series AD/VH

Instruction Manual. T3111 T3111L T3111P T3111Ex

ACS-30-EU-EMDR-10-MOD

Technical Data. Dimensions

Current valve. for AC 24 V pulse/pause control of electrical loads up to 30 kw

RiMatrix S Make easy.

BETA Protecting SITOR Semiconductor Fuses

W150: Miniature photoelectric switch series with completely integrated electronics

Inductive slot sensor

System 6000 Electropneumatic Converter for Direct Current Signals Type 6116 i/p Converter

Your Advantages For safety application up to PL e / Cat. 4 e.g. SIL 3 Manual or automatic start * see variants. Applications.

Safety technique. Emergency stop module BO 5988 safemaster

RISH CON - Hz. Salient Features : Application : Product Features: FREQUENCY TRANSDUCER

Series AMEPR30-AZ up to 2.5A AC-DC / DC-DC LED Driver / Converter

Microcor Wireless Transmitter (MWT)

Technical Data. General specifications Switching element function Rated operating distance s n 4 mm

EXPLOSION-PROOF EMERGENCY LIGHTING FIXTURE FOR FLUORESCENT LAMP EVF-..-EL SERIES

Marine Fire Detection and Alarm Systems

Product and Applications Description. Application Programs. Example of Operation. GAMMA instabus Technical Product-Information.

SEISMIC VELOCITY TRANSDUCER T1-40

FieldIT Head mounted Temperature Transmitter TF02/TF02-Ex

Documentation for. KL2602 and KL2622. Two-channel Relay Output Terminals for 230 V AC / 30 V DC. Version: 1.4 Date:

Power Supplies 3. SDN-P DIN Rail Series

5SV Residual Current Protective Devices

(68.52) X. June 2000 Supercedes February xenex CONVENTIONAL FIRE DETECTION & ALARM SYSTEM. we business differently

Messko. Messko. MTraB - Maintenance Free Dehydrating Breather Ordering specifications XX - XX - XXX - XX

ATEX Installation Instructions for Micro Motion ELITE CMFS Sensors

HARTING mcon 3000 Introduction and features

Transcription:

IQ8Quad Ex (i) Explosion-proof series 117 62 Fire detector with base General detector data according to ATEX: Max. Input voltage (Ui) 21 V Max. Input current (Ii) 252 ma Max. Output current (Io) 10 ma Max. internal capacity (Ci) 1nF Ambient temperature (Ta) -20 C... +70 C Examination Certifi cate TÜV 09 ATEX 554910 Category II 2G (with Ex-Barrier Part No. 804744 or 764744) Explosion protection Ex ib IIC T4 General detector data: Operating voltage 8... 21 V DC Alarm current @ 9 V DC ca. 18 ma Air speed 0... 25,4 m/s Storage temperature -25 C... +75 C Air humidity max. 95% humidity (without condensation) Type of protection IP 43 (with base + option) Material ABS Color white, similar RAL 9010 Weight approx. 110 g Ø: 117 mm; H: 49 mm (incl. base 62 mm) Additional detectors for the explosion zones can be found in the chapters Manual Call Points and Special Detectors. Detailed information about installation and operation can be found in the documentation article no. 798920. All of the following IQ8Quad explosion-proof fi re detectors must be operated with the 805590 base. In the case of operation in standard zones, no individual addressing is possible! For usage in and Zone 2 in case of operation - with individual addressing the Ex-barrier part no. 804744, - in conventional zones the Ex-barrier part no. 764744 must be used! The Ex-barrier separates intrinsically safe and non-intrinsically safe circuits before the explosion prone area to be monitored (explosion zone). The detector base is not included with the delivery of the detectors. Individual addressable operating esserbus / powered loop Ex-Barier (Part No. 804744) Conventional operating external power supply Ex-Barier (Part No. 764744) Application example esserbus transponder 4 zone / 2 relay

803271.EX qah /FY"IQ8Quad Rate-of-rise Detector Ex (i) G 209223 Automatic heat detector with quick semiconductor sensor for the reliable recognition of fi res with fast rate of temperature rise as well as integrated fi xed temperature heat function for the recognition of fi res with slow temperature rise. Intelligent fi re detector with decentralized intelligence, automatic function self-test, emergency mode, storage of alarm and operating data, alarm display. Soft addressing and separate operational display is only possible when operating an esserbus / esserbus-plus IQ8Quad detector without loop isolator, especially for usage in explosion zones. Operation with individual addressing at Ex-Barrier 804744 and as standard detector at Ex-Barrier 764744. ca. 40 μa Area to be monitored max. 30 m² max. 7.5 m Ambient temperature (Ta) -20 C... 50 C Detector specifi cation EN 54-5 A1R : 2002 Special marking for heat detector on light pipe: black ring 803371.EX qbh /FY$IQ8Quad Optical Smoke Detector Ex (i) G 209224 Scattered-light smoke detector for reliable early recognition of fi res. Intelligent fi re detector with decentralized intelligence, automatic function self-test, emergency mode, storage of alarm and operating data, alarm display. Soft addressing and separate operational display is only possible when operating an esserbus / esserbus-plus IQ8Quad detector without loop isolator, especially for usage in explosion zones. Operation with individual addressing at Ex-Barrier 804744 and as standard detector at Ex-Barrier 764744. approx. 50 μa Area to be monitored max. 110m² max. 12 m Ambient temperature (Ta) -20 C... 70 C Detector specifi cation EN 54-7 : 2006

803374.EX qbk /FY-IQ8Quad O 2 T Intelligent Detector Ex (i) G 209225 Intelligent detector with two integrated optical smoke sensors with different scattered-light angles as well as additional heat detector sensor evaluation for the recognition of smouldering fi res up to open fi res with uniform characteristics. Comparison of the heat sensor signals for smoke classifi cation and reduction of deceptive alarms, e.g. from steam or dust. Due to its excellent detection characteristics, the detector is also able to recognize TF1 and TF6 test fi res, described in the standards. The O²T intelligent detector is also suitable for a higher operating temperature of up to +65 C. Intelligent fi re detector with decentralized intelligence, automatic function self-test, emergency mode, storage of alarm and operating data, alarm display. Soft addressing and separate operational display is only possible when operating an esserbus / esserbus-plus IQ8Quad detector without loop isolator, especially for usage in explosion zones. Operation with individual addressing at Ex-Barrier 804744 and as standard detector at Ex-Barrier 764744. approx. 60 μa Area to be monitored max. 110 m² max. 12 m Ambient temperature (Ta) -20 C... 65 C Detector specifi cation EN 54-7:2006 / -5B:2000 / A1:2002, CEA 4021

Ex- 804744 qpm IQ8Ex-Barrier for intrinsic safe detectors Series IQ8Quad Ex (i) G 210047 Design certifi cate BAS 00 ATEX 7087 Ex-Barrier for the operation of intrinsically safe IQ8Quad Ex (i) series detectors directly on the esserbus / esserbus PLus with individual addressing in connection with the Detector Base 805590. Ambient temperature -20 C... 60 C Type of protection IP 20 Weight approx. 100 g Specification (CPD) EN 54-18:2005 W: 20 mm H: 107 mm D: 115 mm A safety barrier does not replace an overvoltage protection according to IEC 801, DIN VDE 0185 and 0855. You can fi nd more detailed information on the installation and the operation for IQ8Quad Ex (i) Series detectors in the documentation Part No. 798920. Available for delivery from end of Q3/2010 Individual addressable operating Ex-Barier (Part No. 804744) 764744 example mpm Application Ex-Barrier for intrinsic safe of detectors Series IQ8Quad and 9100 Design certifi cate BAS 01 ATEX 7005 Ex-Barrier for the operation of intrinsically safe IQ8Quad Ex (i) series detectors in connection with the Detector Base 805590 as well as the 9100 Ex (i) series in connection with the Detector Base 781590. W: 12.5 mm H: 115 mm D: 110 mm A safety barrier does not replace an overvoltage protection according to IEC 801, DIN VDE 0185 and 0855. VdS approval is not required. You can fi nd more detailed information on the installation and the operation in the documentation - Part No. 798920 for IQ8Quad Ex (i) Series detectors - Part No. 798913 for 9100 Ex (i) Series detectors. Conventional operating external power supply Ex-Barier (Part No. 764744) esserbus transponder 4 zone / 2 relay Application example

764745 mpn Isolation and assembly block for safety barrier Detectors for Hazardous Areas For insulated (earth-free) mounting of 764744 barriers onto standard C rail. 764752 mpu4housing for Ex-Barrier Polyester-Housing for the insatallation of up to max. 10 ex barriers with integrated inside mounting rail. Also for operational application under extreme environmental conditions suitably. Type of protection IP 66/67 Housing glass-fiber reinforced polyester Color grey, similar to RAL 7000 W: 255 mm H: 160 mm D: 250 mm Mounting material Features chemically resilient temperature resilient fl ame retardant noncorrosive sea water resistant nonhalogen, UV resistant 764754 mpw: Threaded cable connection for housing 764752 Threaded cable connection for housing 764752. Ambient temperature -20 C... 95 C Type of protection IP 66 Material Polyamid Color blue, similar to RAL 9005