User's Manual. Model 407112 Heavy Duty Vane Thermo-Anemometer



Similar documents
User's Manual. Heavy Duty Dissolved Oxygen Meter Model

User's Manual. Model Laser Photo / Contact Tachometer. Introduction

Model RPM10 Laser Photo / Contact Tachometer with IR Thermometer Patented

Dual Laser InfraRed (IR) Thermometer

User Manual. Humidity-Temperature Chart Recorder. Model RH520

User Guide. Heavy Duty Dissolved Oxygen Meter. Model

User Guide. ExStik TM ph (PH100 & PH110) and ORP (RE300) Waterproof Series Pens. Patent Pending

Dual Laser InfraRed (IR) Thermometer with Color Alert

User's Guide. Integrating Sound Level Datalogger. Model Introduction

Dual Laser InfraRed (IR) Thermometer

ExStik TM ph Waterproof Meters

User's Guide. Digital Viscotesters. Model High Range (0.3 to 4000 dpas) Model Low Range (1.5 to 330 mpas) Introduction

EzFlex Combustible Gas Leak Detector Model EZ40

Ground Resistance Clamp-On Tester

User's Guide Integrating Sound Level Datalogger Model

High Temperature InfraRed Thermometer with Laser Pointer

RS Stock No Instruction Manual RS-1340 Hot Wire Anemometer

User s Guide HHF81. Anemometer, Hygrometer, Light Meter, Thermometer. Shop online at omega.com

Light Meter (Foot Candles)

OPERATION MANUAL. Pen type, separate electrode SOIL PH METER Model : PH-220S

TABLE OF CONTENTS 11.0 WARRANTY

INSTRUCTION MANUAL DTH Fax: (503)

User's Guide. ExStik DO600. Dissolved Oxygen Meter RECALL. Dissolved Oxygen DO600

User's Guide. Digital Psychrometer. Model RH390. F C WBT Dew Point MAX MIN

VOLTAGE/CURRENT CALIBRATOR ISO-TECH ILC-421

4-Channel Thermometer / Datalogger

Microwave Meter. Instruction Manual

User s Guide HHAQ IN-1 Psychrometer With Enthalpy. Shop online at omega.com SM

Temperature, Humidity & Dew Point Chart Recorder

User's Guide. Digital Sound Level Meter. Model

DSM155 Digital LED Light Meter User s Manual DSM155

DISSOLVED OXYGEN METER Model : DO-5509

Temperature Humidity Meter

DVI+HDCP 4x1 Switcher User Manual

User Guide. Temperature and Humidity Datalogger. Model 42280

DICKSON PR100/PR300/PR500 DICKSON. Pressure Logger Operation. Contents:

Hygro-Thermometer + InfraRed Thermometer Model RH101

Instruction Manual Temp 4/5/6 Temperature Meter Series

O C M III. Open Channel Flow Monitor

Ultrasonic Distance Meter. Operation Manual

Ground Resistance Clamp On Tester

Component With Audio. Model # COMP-2-HDMI-AD USER MANUAL.

Mini InfraRed Thermometer with Laser Pointer

USER GUIDE. LED Light Meter. Model LT45

User Guide. 4 wire Earth Resistance Tester Model GRT300

Wireless Indoor/ Outdoor Thermometer

WindLog User s Guide

ECO SENSORS, INC. OZONE SENSOR AND MONITOR

Professional Thermohygrometer

DM Series CONTENTS. 1. Features Applications General Calibration Dimensions Specifications Calibration procedure 7

RGC-IR Remote Gas Calibrator for IR400

LCD5500Z / PKP-LCD v3.x Installation Instructions

About this Manual. Support for Your Product

Model SRMD Setra Remote Monitoring Display

About Your NetBotz 4-20mA Sensor Pod

User's Guide. Pinless Moisture Meter. Model MO257


LST In-Dash Digital Sonar Gauge. Installation & Operation Instructions

User Guide. HDMI Active Cable Extender. DVI-7370c

TABLE 1: Wiring Terminals. Connect to... 1C 1H 2C 2H 1H1C 2H1C 2H2C 3H2C

BroadBand PowerShield. User Manual

Installation and Operation Manual. Digital Remote Meter for Monitoring System Performance. Version: RM-1

In-Situ Inc. Warranty / Terms & Conditions / Software License. This warranty policy applies to items that shipped prior to January 1, 2012.

USER MANUAL. Model U ForeFront Alarm Card SALES OFFICE (301) TECHNICAL SUPPORT (301) An ISO-9001 Certified Company

Soil Sensor Reader PRODUCT MANUAL

Optical Wireless Mouse. User s Manual

RI-215A Operator s Manual. Part Number: RK Revision 0 Released: 10/3/05

CM100. Carbon Monoxide Meter. Users Manual Mode d emploi Bedienungshandbuch Manual d Uso Manual de uso Användarhandbok

E8887 First Edition February 2014

INTMOD485-LH Protocol Converter

SFS81 Series. Servo Finishing Stand PUSHCORP, INC. Dallas, Texas

RS DIGITAL THERMOMETER

Part I - Installation

CUSTOMER SERVICE CONTACTS

Current Monitoring Kit

Operating Your System

Single Port T1/E1 Tap

Signal Manager Installation and Operation Manual

Dielectric Withstand and Ground Bond Testers For Production Line Safety Agency Compliance Testing

WINEGARD MOTORIZED SENSAR ANTENNA Models MA1055W & MA1055G MADE IN U.S.A. U.S. Patents D500,496 and 7,358,909 INSTALLATION MANUAL

Alarm Clock USER GUIDE

General Purpose Thermal Mass Flowmeter Model 4140/4143

Wolverine Data PASS Portable Scanner User Manual V1.0

Humidity Sensor. Model HU-224/225

Multifunction Process Calibrator

User's Guide. True RMS Industrial Multimeter

DELORME. Getting Started with. Earthmate GPS BT-20. Bluetooth

Dual-Cool Notebook Cooler Pad. User s Manual

DTM04 TANK MONITOR DTM08 TANK MONITOR Dtm12 TANK MONITOR. Installation and Operation Manual

Data Analysis Software

Mold Alert... Operation Manual P0270

AMC GENERIC WARRANTY POLICY GUIDE

VPCCCare. Virtual PC Center Service Warranty Program

Data Entry Foot Switch Operation Manual

2 To 1 Serial (RS-232) AUTO SWITCH. AS-251S User Manual

TS-300-MSF TS-300 INSTALLATION AND CONFIGURATION MANUAL

Extender for HDMI 1.3 over CAT6. GTV-HDMI1.3-CAT6 User Manual.

CHAPTER 1. GETTING STARTED... 1

JNIOR. Overview. Get Connected. Get Results. JNIOR Model 310. JNIOR Model 312. JNIOR Model 314. JNIOR Model 410

Installation Guide. WSD-100 Wind Speed and Direction Sensor For XR5 Data Loggers. February, 2011

Transcription:

User's Manual Model 407112 Heavy Duty Vane Thermo-Anemometer

Introduction Congratulations on your purchase of Extech's Heavy Duty Anemometer. The Heavy Duty Anemometer is an instrument used for measuring the speed (velocity) at which air is flowing. Extech's vane anemometers indicate air flow in five units of measure: Feet per minute, Meters per second, Miles per hour, Kilometers per hour, Knots. Vane anemometers use a remote wheel that freely rotates in response to air flow. In addition to air velocity, Extech's Vane Anemometers measure temperature in both Centigrade and Fahrenheit via a built in thermistor. Specifications Circuit Custom LSI microprocessor circuit. Display Dual function, 13 mm(0.5") Super large 1999 count LCD display with contrast adjustment for best viewing angle. Measurement units m/s, km/h, ft/min, knots, mph, Temp.- O C, O F., Data hold Retain reading in display Sensor Structure Air velocity sensor :Conventional twisted vane arms and low - friction ball-bearing design. Temperature sensor :Precision thermistor. Memory Recall Records Max, Min and Average readings with RECALL. Power off Auto shut off saves battery life, or manual off by push button. Data Output RS 232 PC serial interface. Operating Temp. 0 C to 50 C (32 F to 122 F). (instrument only) Operating Humidity Max. 80% RH. Power Supply 006P DC 9V battery (Heavy duty type). Power Current Approx. DC 8.3 ma. Weight 0.84 LB / 381 g (included batteries & probe) Size Main instrument: 7.1 x 2.8 x1.3 inch (180 x 72 x 32 mm) Sensor Head: Round, 72 mm diameter Accessories Instruction manual, Sensor probe Air Velocity Specifications Measurement Range Resolution Accuracy (% of full scale) ft/min (feet/min) 80-4921 ft/min 1 ft/min ± (2% + 20ft/min) m/s (meters/sec) 0.4-25.0 m/s 0.1 m/s km/h (kilometers/hour) 1.4-90.0 km/h 0.1 km/h mph (miles/hour) 0.9-55.9 mph 0.1 mph knots (nautical miles/hour ) 0.8 to 48.6 knots 0.1 knots Temperature Specifications: ± (2% + 1d) Range (probe only) Resolution Accuracy +/- 32 O F to 122 O F / 0 O C to 50 O C 0.1 O F / 0.1 O C 1.5 O F / 0.8 O C 2

Meter Description 1. LCD Display 2. Keypad 3. Battery compartment (rear) 4. Sensor input socket 5. RS232 output socket 6. Vane sensor 7. Protective holster Operation 1. Install the "Sensor Plug" into the "Sensor Input Socket. 2. Press "Power Off/On" to turn the instrument power "ON". 3. Select the temperature units by pressing " C/ F ". The display will indicate " C" or " F" as selected. 4. Select the air velocity units by pressing "Unit", The display will indicate "m/s", "km/h", "ft/min", "knot", or "mile/h" as selected. 5. The meter will now display the current temperature and air velocity. yellow dot Note: For maximum accuracy in temperature measurements, the yellow dot on the vane should be facing the direction of the air flow. airflow Data Hold: During the measurement, pressing "Data Hold" will hold the displayed value and the LCD will display the "D.H" indicator. Press "Hold" again to release the data hold function. Data Record (MAX/MIN/AVG Readings) When selected, the DATA RECORD function records and stores the maximum, minimum and average readings. To start the DATA RECORD function: a) Press "RECORD" once. The "REC" indicator will appear on the display. b) Press "RECALL" once to retrieve the "Max" reading. The "Max" indicator along with the maximum values will appear on the LCD display. c) Press "RECALL" once, the "Min" indicator along with the minimum values will appear on the LCD display. d) Press "RECALL" once, the "AVG" indicator along with the average values will appear on the LCD display. e) To disable the "Data Record " function, press "Record" again. The display indicators "REC", "Max", "Min", "AVG" will disappear. 3

Measurement Considerations 1. The meter is designed with an "Auto shut off" feature to save battery life. The power will automatically shut off if no function button is pressed in any 10 minutes period. To disable "Auto shut off" while taking measurements, press "RECORD" and engage the record function. 2. The volume of air flowing through a duct or vent can be determined by taking the area of the duct in square units (i.e. square feet) and multiplying this value by the measured linear velocity ( i.e. feet per minute). This gives: ft/min x ft 2 = ft 3 /min (CFM) Battery replacement The low battery indication appears as a "LBT" on the left corner of the display. When the "LBT" appears, replace the battery as soon as possible. Reliable readings can be obtained for several hours after the first appearance of the low battery indication. To replace the battery: 1 Remover the meter's rubber protective holster. 2 Pry the Battery Cover off using a small coin or screwdriver and remove the battery. 3 Replace the 9V battery (heavy duty type) and reinstall the cover. 4 Make sure the battery cover is secured after changing the battery. Calibration and Repair Services Extech offers complete repair and calibration services for all of the products we sell. For periodic calibration, NIST certification or repair of any Extech product, call customer service for details on services available. Extech recommends that calibration be performed on an annual basis to insure calibration integrity. Warranty EXTECH INSTRUMENTS CORPORATION warrants this instrument to be free of defects in parts and workmanship for three years from date of shipment (a six month limited warranty applies on sensors and cables). If it should become necessary to return the instrument for service during or beyond the warranty period, contact the Customer Service Department at (781) 890-7440 ext. 210 for authorization. A Return Authorization (RA) number must be issued before any product is returned to Extech. The sender is responsible for shipping charges, freight, insurance and proper packaging to prevent damage in transit. This warranty does not apply to defects resulting from action of the user such as misuse, improper wiring, operation outside of specification, improper maintenance or repair, or unauthorized modification. Extech specifically disclaims any implied warranties or merchantability or fitness for a specific purpose and will not be liable for any direct, indirect, incidental or consequential damages. Extech's total liability is limited to repair or replacement of the product. The warranty set forth above is inclusive and no other warranty, whether written or oral, is expressed or implied. Copyright 2001 Extech Instruments Corporation. All rights reserved including the right of reproduction in whole or in part in any form 4

Useful Equations and Conversions Area equations H R W A = W x H A = pi x R 2 Cubic equations Units Conversion Table CFM (ft 3 /min) = Air Velocity (ft/min) x Area (ft 2 ) CMM (m 3 /min) = Air Velocity (m/sec) x Area (m 2 ) x 60 m/s ft/min knots km/h MPH 1 m/s 1 196.87 1.944 3.6 2.24 1 ft/min 0.00508 1 0.00987 0.01829 0.01138 1 knot 0.5144 101.27 1 1.8519 1.1523 1 km/h 0.2778 54.69 0.54 1 0.6222 1 MPH 0.4464 87.89 0.8679 1.6071 1 RS232 PC Interface The meter has a RS232 serial data port. This interface was designed to operate with the Extech Data Acquisition Software (p/n 407000) and enables the user to capture, store and display readings on a PC. For more information, contact Extech or refer to the 407000 user's manual for details on the PC interface. Tech Support Hotlines 781-890-7440 ext. 200 extech@extech.com www.extech.com 5