KRAL Electronics BEM 300 and BEM 500.



Similar documents
Series DFMT Digital Paddlewheel Flowmeter

PIEZOMETER AIRFLOW MEASURING RING

Preset Counter signo 721

Multifunction devices

Frequency Converter Fv

Electronic pressure switch with display Model PSD-30, standard version Model PSD-31, with flush diaphragm

Type: EASY719 DC RC Article No.: Ordering information Relay outputs Quantity 6 Power supply V DC 24 V DC. Description

Turbine Flow Sensor Series VTR

AVL FUEL MASS FLOW METER & FUEL TEMPERATURE CONTROL

Quick Connect. quick - simple - efficient.

Automation System TROVIS 6400 TROVIS 6493 Compact Controller

Physical Specifications (Custom design available.)

DC Electronic Loads 8500 series

FLOW CALCULATOR INSTRUCTION MANUAL MESURES BAMOPHOX M1 02 E MES FLOW CALCULATOR /1

How To Use A Flowmeter

Process modules Digital input PMI for 24 V DC inputs for 120 V AC inputs

Wahl C50 Calibrator FEATURES

Short information Parameters are programmed via front-side membrane keypad

COMBIMASS. Technical Data COMBIMASS eco-bio +

T-SERIES INDUSTRIAL INCLINOMETER ANALOG INTERFACE

Vroom Hardware manual ver Code 114VROOHWE00. Vroom CANBUS USER INTERFACE WITH LCD GRAPHIC DISPLAY AND WITH TEMPERATURE AND HUMIDITY SENSOR

Flexible Counter Series in DIN size 24 x 48 mm

API Marine. BMS Presentation. Ballast Measurement Systems

Analogue Input, 4-fold, MDRC AE/S 4.1, GH Q R0001

Short Form Catalogue. Alarm Systems. Reliable Supervision and Control

Features. Display. Measurements. Intelligent. Accuracy. Models. Installation DEIF A/S. Multi-instrument D

Portal Software GSM-PRO Run LED displays module activity Com LED displays activity on the GSM network GSM-PRO

Product Information Sheet UH36 Hi Pot Tester

DREXELBROOK. USonic-R Series. Ultrasonic Level Measurement System. User Friendly

AMTRON E-30 Compact heat and cooling meter

Temp-485-Pt100. A temperature sensor (Pt100 or Pt1000) communicating over the RS-485 bus with a simple communication protocol

Measurement. SITRANS F US Inline. Transmitter FUS080/FUE080 4/219

Tubular Analog model resolution: 0,5 mm (SLOW mode), 1 mm (FAST mode) Right angle Repeatibility: 0,7 mm Vdc

Variable Preset Counter signo 723.1

ABB i-bus EIB / KNX Analogue Input AE/S 4.2

2.24. Pump Controller 704. Data Sheet

On-line Machine Condition Monitoring [The CMS System]

RISH CON - Hz. Salient Features : Application : Product Features: FREQUENCY TRANSDUCER

Online Infrared Flue Gas Analyzer Gasboard 3000

Technical data. General specifications. Signal voltage V DC Signal duration. 1 s Input 2. Signal voltage. 1 s Analog output.

Installation and User Guide

DRTS 33. The new generation of advanced test equipments for Relays, Energy meters, Transducers and Power quality meters

Electro-Magnetic Flowmeters COPA-XT 2-Wire DT43

Technical Manual. FAN COIL CONTROLLER COOLING or HEATING ANALOG or PWM Art A

ELECTROMAGNETIC FLOWMETER COMPACT

1. SAFETY INFORMATION

NEW. EVEN MORE data acquisition and test stand automation

MINIMAT-EC-Servo Screwdriver Spindles

Certified according to DIN EN ISO 9001 Technical Datasheet C-Flow Coriolis Mass Flow Meter

M2M The measure of efficiency

Duct Humidity Transmitter

Application/Connection Examples

Relative Humidity Sensors, Transmitters and Calibration Products Relative Humidity Measurement and Calibration

Automation Unit TM 1703 ACP Flexible automation and telecontrol

OZW30. Central Unit SYNERGYR

713 Open Channel Flowmeter and Transmitter. All-in-one package for open channel flow measurement.

Data Sheet. Electro-mechanical counters Hengstler 800 series

Gas Custody Transfer Calibration

NC-12 Modbus Application

Product Information. Gateway For Connecting EnDat Encoders to PROFIBUS-DP

Siemens AG 2011 SINAMICS V60. The perfect solution for basic servo applications. Brochure May 2011 SINAMICS. Answers for industry.

T Substation Maintenance and Commissioning Test Equipment

For Multi-Parameter Meters see mvx

Repeaters and Mimics Data Sheet

Multi-Range Programmable DC Power Supplies 9115 Series

VOLTAGE/CURRENT CALIBRATOR ISO-TECH ILC-421

Hydraulic Control Solutions

Temperature & Humidity SMS Alert Controller

WEB log. Device connection plans

EFC Frequency converters

Sigma Control PC INSIDE. 97 psi 187 F R on load

Non-invasive CLAMP-ON ultrasonic flowmeter for liquids

COMPALARM AP GENERAL MAIN FEATURES

Technical data. General specifications. Indicators/operating means. 30 Hz Multiplex operation 30 Hz / n, n = number of sensors, n 5

User Manual V SDM220MODBUS. Single-Phase Two Module DIN rail Meters

The DL8000 Preset Controller. The Ideal Device for Controlling and Measuring the Loading of Liquid Hydrocarbons into Transporting Tankers

T U R B I N E G A S M E T E R

IFC 070 Technical Datasheet

WaterMAG. Electromagnetic Flowmeter for Water Applications. Model MCB10A OVERVIEW APPLICATIONS FEATURES. No. SS2-MCB

HYDRUS ULTRASONIC METER

Digital pressure gauge for industrial applications Model DG-10-S, Standard version Model DG-10-E, Enhanced version

Vision OPLC. V R34/V350-J-R34 Technical Specifications. Technical Specifications

Process Alarm Solutions

HEAT MONITORING AND CONTROL INSTRUMENTS FOR TRANSFORMERS MB 103 TEMPERATURE CONTROL UNIT PT 100 TEMPERATURE SENSOR

Michael Montgomery Marketing Product Manager Rosemount Inc. Russ Evans Manager of Engineering and Design Rosemount Inc.

Power consumption (kw)

Voltech DC1000. Precision DC Bias Current Source

Take total control of your HVAC system with cost-saving flow and thermal energy meters

Electronic Pressure Switch EDS 300

Voltage Regulator SPAU 341 C. Product Guide

DC1100 & 1400 Energy Controllers. Satchwell DC1100 & DC1400 for energy-efficient temperature control in smaller buildings.

Speed Control Relays SX2

Sentinel LCT. Panametrics Ultrasonic Flowmeter for Liquid Custody Transfer Measurement. GE Measurement & Control Solutions. Benefits.

Easily installed and simple to set up, Flow Pulse uses an acoustic technique never before seen in flow measurement to deliver reliable results across

CONFIGURABLE SAFETY RELAYS

JUMPFLEX 857 Series ma V ma. Transducers / Relay and Optocoupler Modules

ERMA-Electronic GmbH - Max-Eyth-Str Immendingen - Tel: +49(0)7462/ Fax: +49(0)7462/ Technische Änderungen vorbehalten

Certified according to DIN EN ISO 9001 Technical Datasheet TRICOR Series Mass Flow Meters

Controls for fan coil units and cassettes

Programming Logic controllers

Transcription:

KRAL Electronics BEM 300 and BEM 500.

KRAL Electronics BEM 300 and BEM 500 Electronic units that are coordinated to KRAL flowmeters and their diverse applications. Coordinated to the flowmeters and their Perfect operation, applications. informative display. Users of conventional universal display units often the required information and A display unit must supply cannot make use of their assure accurate operation. device s options. There is The KRAL BEM 300 and often a lack of functions 500 always display the that are important for special applications. measured flow values with their units. The display is clear and very KRAL BEM 300 to 500 electronic units aid in the easy to read. There is a performance of the KRAL choice of four languages. Volumeter. The high quality electronic components the calibration factors and KRAL sets up the units, and evaluation algorithms the density tables to meet used, maintain precisely customer specifications. If measured flow values to you need to make changes, be shown on the display an easy to follow menu as well as the signal outputs. The BEM 500 uses figuration software for is available including con- KRAL calibration values PCs. Contrast and brightness are adjustable. for linearization. Temperature differences and liquid pulsations which can falsify the readings are corrected. The fast route to the measurement result. Fitting the BEM 300 and 500: Connecting the sensors: Connecting power: Reading the measured values: Self-diagnostic and monitoring. The BEM 300 and 500 protect the KRAL Volumeter and the customer s installation. The flow and temperature ranges of the flowmeters are stored in the electronics and if values are exceeded then the alarms are displayed. A bypass relay can be activated using flow rate limit value. The function of the temperature sensors is monitored. Knowing the temperature, the flow volume, the flow direction and the consumption assures the integrity of the installation. Control cabinet mounting, on the flow measuring device, wall mounting or on the piping. Max. 6 sensors, each with 3 terminals. Mains supply: direct voltage 24 V DC ± 20 %. Total, rate, temperature. Data evaluation, signal forwarding. KRAL provides special PC software for data capture, storage and evaluation as an option. Measured values can be stored for longer periods and evaluated at a later date. Immediate data analysis allows instant result of set-up and installation. Universal signal forwarding includes scalable analog and pulse outputs, as well as a Modbus RTU interface. Additional displays can be connected for remote indication. 2

Performance characteristics.* Display: Keys: Measured value: Units: Signal forwarding: Power supply: Environment: Mounting: 3 x 1 inches LCD, contrast and illumination software-adjustable. 5 robust micro-switches. Total, flow rate, accumulated total. SI, UK or US units. Total, rate as volume or mass. Temperature, density. Scalable 4 to 20 ma or 0 to 10 V analog outputs, scalable pulse outputs, Modbus. 24 V DC. Degree of protection IP65, robust plastic casing. Operating temperature -4 to 158 F. In the control cabinet, on the flow measuring device, wall mounting or on the piping. Decision aid. Advantages of the BEM 300. Low-cost version. Simple basic functions for precise flow measurement. Pressure pulse compensation. Mass calculation with constant density. Advantages of the BEM 500. Temperature compensation. Pressure pulse compensation with counter of flow direction change. Two-channel, e.g. for differential measurement. Mass conversion and density tables. 7 point linearization. Limit value for a relay output (bypass valve). Threshold value for signal suppression. * The performance characteristics depend on the type of device. For details, see the ratings section on page 10. For a description of our precision flowmeters, please ask for our product brochures, or visit us on the Internet at www.kral-usa.com. 3

The Solution BEM 300 and BEM 500 Easy to use and informative measurement display. Clear menu structure. Shortcuts. Retracing your steps. Informative display. Settings are made using 7 structured menus. Menu 1 contains the measured values, menu 2 and 3 the units and the settings. The and keys are used to navigate through the menus. Each menu has several pages. The display menu has pages for displaying the rate, the total, and the consumption. Use and to change pages. To give you fast access to important information, both the BEM 300 and the BEM 500 use shortcuts. Simultaneously pressing the SET and keys will give you a choice of languages. For fast help, press both and to bring up a quick reference guide. Pressing and simultaneously takes you straight to the consumption measurement result. Do you want to quickly check the changed settings? Sometimes just pressing a button is enough to take you back to the display you want to change. For example: if you are in the consumption display and want to change the units. Use to move to Menu 2. This is where the settings are made. Once you have made the change, will take you back to the consumption display. The ability to view four lines at once makes for a useful display. The first line always contains the menu and page numbers. The information on flow measurement appears in line 2. The measured values are given with their accompanying unit. The contrast and brightness are adjustable. 4

Standard flow measurement. Flow rate. The flow rate is displayed with a choice of units, such as l/min, galus/min or kg/hr. The temperature indicates the actual temperature of the liquid in Volumeter A. If the temperature is outside the valid range for this Volumeter, an alarm message is displayed. Total. The flow volume is displayed with a choice of units such as l, gal or kg. Total 1 can be reset without a password, Total 2 requires a password. Connecting a second Volumeter. The flow rate and flow volume of the second Volumeter B are also displayed with a choice of units. The temperature for the rate is given in C or F. Two Volumeters are usually connected to measure consumption. With the BEM 500, it is possible to take two independent measurements with just one set of electronics and two KRAL Volumeter. Consumption measurement. When measuring consumption, for example in engines or burners, the measurement result is calculated by subtraction. Because of error propagation, the individual measuring devices need to be very precise to ensure that the system keeps measuring accurately. Since KRAL Volumeter are robust precision flowmeters, they are very often used to measure consumption. So with the BEM 500, consumption is the first display 1.01. 5

Volume and Mass Measurement KRAL Volumeter are volumetric PD-flowmeters. With the BEM 500, temperature measurement and density tables are used to convert to units of mass. Temperature. Being able to connect up to two temperature sensors gives the following options: mass conversion via density tables, flow display relative to a preset temperature, conversion of the flows of two Volumeters to the inlet temperature, Volumeter overheating warning and installation monitoring. Density. Two density tables can be entered. Density tables allow conversion to units of mass and allow conversion of the flow to a pre-selected temperature. Each density table has up to 10 temperature density pairs. The density table can be selected in Menu 2. Setting the units. The units of flow rate, total, temperature, and density can be selected in accordance with SI, UK and US units as volume and mass units. 6

Measuring accuracy is further increased by linearization. Accuracy [%] relative to the measured value +1,0 +0,3 +0,1-0,1-0,3 200 cst 20 cst 2 cst -1,0 1 10 50 100 150 Flow [% of Q nenn ] KRAL Volumeter linearity. KRAL Volumeter measure very precisely, with an accuracy of ± 0.1 % of the measured value. The wide turn down ratio of approx. 100:1 shows the linear characteristic of our robust measuring devices. With linearization at 4.6 cst, the curve is stored in the electronics. This further increases the accuracy of evaluation of the perfectly coordinated complete system of flow measuring device and electronics unit. Calibration. Each KRAL Volumeter is calibrated to our calibration standard. The calibration factors (K-factors) can be taken from the calibration certificate and entered into the electronics. Linearization. The factory calibration certificate contains 7 calibration factors (pulses per liter) with the associated frequency. The mean value specified on the calibration certificate is generally the one used. In addition, 7 individual K-factors can also be entered into the electronics. The electronics calculate the calibration curve. In this way, each frequency is given the associated K-factor. The characteristic curve of the Volumeter is stored in the electronics thus ensuring precision. 7

Signal Forwarding and Installation Safety BEM 300 and BEM 500 are highly flexible about exchanging data. Analog output. Pulse output. There are either two 4 to 20 ma or 0 to 10 V analog The BEM 500 has two pulse outputs, to which the totals outputs available. Analog outputs are assigned to the of Volumeters A and B, as well as the consumption can flow rate or total. Scaling is effected by adjusting the be assigned independently. In the Encoder setting, maximum value. If the flows fluctuate, signal forwarding can be smoothed. detect the flow direction. The pulse value, for example, two 90 out of phase square wave signals are output to 1 pulse corresponds to 200 pounds, is adjustable. Modbus. With the BEM 500, data forwarding via Modbus RTU is possible via the serial interface. The address can be adjusted. Relay for bypass and batching. This function allows the automatic activation of a bypass valve when a volumeter blocks. Furthermore, a simple filling function can be implemented with the BEM 500. 8

BEM 300 and BEM 500 have numerous mounting options. Fast attachment options. The universal mount is best suited for the various attachment options. The mounting frame and a KRAL toolkit are included among the items supplied as standard, in order to facilitate easier installation. Control cabinet mounting. Wall mounting. Volumeter mounting. With the mounting frame, the BEM 300 and the BEM 500 are set up for mounting in the control cabinet. With the universal mount, the BEM 300 and the BEM 500 can be mounted on the wall. Degree of protection IP65. For mounting directly on the KRAL Volumeter, use the universal holder and the Volumeter holder. You can easily use the same components for mounting on horizontal or vertical pipes. Degree of protection IP65. 9

BEM 300 and BEM 500 Device Selection Technical data. BEM 300 BEM 500 Description one channel, display of flow rate, 2 resettable totals, pulsation compensation, analog and pulse output, Modbus RTU interface two channels, display of flow rate, 6 resettable totals, temperature, linearization, pulsation compensation with counter of flow direction change, analog, relay and pulse outputs, Modbus RTU interface Power supply 24 V DC ± 20 % same as BEM 300 Environment Casing Operating temperature Storage temperature Air moisture content EMC Shock Vibration Mounting Dimensions Degree of protection Material Weight -4 to 158 F -4 to 176 F 97 % relative humidity EN 61 326 EN 61 373 EN 60 068-2-47 EN 60 068-2-64 wall mounting, installation, control cabinet mounting 4.5 x 4.5 x 4.6 inches (WxHxD) IP65 plastic, UV-resistant coating 2.2 pounds same as BEM 300 same as BEM 300 Sensor Sensor type Sensor supply Ub Rate accuracy Frequency PNP, NPN, Namur 24 V DC, 8.2 V < 0.1 % 20 khz PNP, NPN, Namur, PT100 24 V DC, 8.2 V < 0.1 % 20 khz Operation and electronics Display Keyboard LCD, 4 lines, 20 characters, with backlighting 5 robust micro-switches same as BEM 300 Analog output Range Resolution 1 at 4 to 20 ma or 0 to 10 V (Cycle time 20 ms) 16 bit 2 at 4 to 20 ma or 0 to 10 V (Cycle time 20 ms) 16 bit Pulse output Maximum frequency 1 output at 250 Hz 2 outputs at 250 Hz direction of rotation option Relay output Function Voltage at nominal load Switching current, resistive Switching current, inductive break contact, make contact 250 V AC, 30 V DC 6 A AC/DC 2 A AC/DC Bus Type Baud rate Data format Modbus RTU via RS 232 or RS 485 (slave) 9600 baud 8N1 (8 data bits, no parity, 1 stop bit) same as BEM 300 10

Precise flow measurement in practice. Precise cylinder lubri- Test bench. Fuel consumption measurement. cating oil measurement for diesel engines. Joint projects. KRAL Volumeter provide laboratory measuring accuracy even in rough operating conditions. The BEM 300 and BEM 500 electronic units achieve this goal and put measured values of the Volumeter on display. You only have to hold the KRAL electronics in your hand to feel the sturdy construction. The casing is made from high quality plastic, has a UV-resistant coating and rates a degree of protection IP65. Typical applications for BEM 300 and BEM 500 include test benches for aircraft components as well as measuring fuel consumption on engine and turbine test benches. The complete system of KRAL Volumeter, sensor technology and BEM 500 is perfectly designed for measuring fuel consumption. With two connected KRAL Volumeter, the BEM 500 calculates consumption by inlet flow rate and return flow rate subtraction. There can be a vast difference in temperature between the inlet flow and return flow. The electronic unit relates every flow to the according temperature. Patented pressure pulse compensation balances the fuel return flows of the pulsating liquid column, which is excited by the pressure surges of the injection pumps. The bypass can be activated via a relay. High running costs reduce the profit in power generation. KRAL Volumeter in combination with KRAL electronics ensure precise cylinder lubricating oil measurement for diesel engines. This results in major savings in generator running costs. Our business associates are particularly appreciative of the cooperative working relationship they have with the KRAL AG. From the best-possible support to the successful conclusion of the project, business relations are always friendly. We talk to our customers and collaborate closely on technical matters. You can rely on us. BEM 900. For complex applications with up to 16 flowmeters, the pre-programmed BEM 900 is the optimum in electronics. Flow, consumption measurement, monitoring, data capture and data evaluation are also possible. 11

KR AL- USA, Inc., P.O. Box 2990,Matthews NC 2810 6, 9 01A Matthews- Mint Hill Road, Matthews NC 28105, USA Tel.: (70 4) 814-616 4, Fax: (70 4) 814-6165,www.kral-usa.com,e -mail: sales@kral-usa.com Edition 06/10. All rights reserved. Subject to change.