Utility Systems Sanitary Sewer System Plan



Similar documents
DeSoto County is not a water service provider and does not operate any

Design Criteria & Service Goals

APPENDIX M-2 SANITARY SEWER TECHNICAL MEMORANDUM. Stadium Reconstruction EIR

GIS in Wastewater Collection System Master Planning

SANITARY SEWER MASTER PLAN

Monterey Regional Water Pollution Control Agency. Sewer System Management Plan

PART 6 - STANDARD DESIGN AND CALCULATION FORMS 6.1 SANITARY SEWER DATA SHEET

How To Water System

Land Use Assumptions Plan for Water Supply, Water Service and Wastewater Service

City of Bakersfield Public Works Department Sewer System Management Plan December 2014

3.6.1 Existing Conditions - Police, Fire, Ambulance, Water, Sewer, & Solid Waste

Emerging Technologies in Wastewater Collection Systems

SECTION 5: SANITARY SEWER SYSTEM DESIGN

RECOMMENDED PROGRAM FOR WELL AND SEPTIC SYSTEM REAL ESTATE TRANSACTION INSPECTIONS

CHAPTER 11 STORM DRAINAGE

Maricopa Association of Governments. Technical Memorandum No. 1 INFRASTRUCTURE DEVELOPMENT COSTS. August 2001

CHAPTER 2 HYDRAULICS OF SEWERS

High-Rate Retention Treatment Facility for CSO Control in Windsor Riverfront East

The checklist utilized by the Authority will be similar to that which is shown below. Project Name: Location: Consulting Engineering Firm:

Water Utility Financial Plan and Rates Study

TITLE 252. DEPARTMENT OF ENVIRONMENTAL QUALITY CHAPTER 656. WATER POLLUTION CONTROL FACILITY CONSTRUCTION STANDARDS

STATE OF VERMONT AGENCY OF NATURAL RESOURCES DEPARTMENT OF ENVIRONMENTAL CONSERVATION WASTE MANAGEMENT DIVISION SOLID WASTE MANAGEMENT PROGRAM

SECTION 3 SANITARY SEWER DESIGN

Micromanagement of Stormwater in a Combined Sewer Community for Wet Weather Control The Skokie Experience

Does my drinking water contain Fluoride?

660 Utility Supply Comprehensive Plan Section 660

Based on the above, it is recommended that Lift Stations #1 and #3 be abandoned and their flows be diverted to the regional Lift Station #8.

STEAMBOAT LAKE WATER AND SANITATION DISTRICT PETITION FOR AMENDMENT TO SERVICE PLAN TABLE OF CONTENTS. SECTION DESCRIPTION Page

SEPTIC SYSTEM CONSTRUCTION REQUIREMENTS ST. MARY S COUNTY HEALTH DEPARTMENT

2015 Utility Rates. Electric Garbage Recycling Sanitary Sewer Storm Sewer Water and Yard Waste

2.0 DESIGN CRITERIA FOR WATER DISTRIBUTION SYSTEMS

North San Jose Neighborhoods Planning Taskforce

WATER METER CALIBRATION, REPAIR, AND REPLACEMENT PROGRAM

Kansas City s Overflow Control Program

Chapter 9 Sanitary Sewers

Design of Sewage Pumping Stations by John Zoeller, PE, CEO/President

Altoona Water Authority. Infrastructure Overview

REGION OF PEEL PUBLIC WORKS DESIGN, SPECIFICATIONS & PROCEDURES MANUAL

UPDATED FUNCTIONAL SERVICING and STORMWATER MANAGEMENT REPORT

City of Largo Environmental Services Department Environmental Control Program th Avenue North Clearwater, FL Phone: (727)

Texas Commission on Environmental Quality Page 1 Chapter Design Criteria for Domestic Wastewater Systems

Components of a Basement Flooding Protection Plan: Sewer System Improvements. November 2000

1. Site plans assist the Fire Department to determine where a potential spill can be contained. The detailed site plan shall include the following:

Cost Estimating Procedures for Raw Sewage Overflow Control Program

Dewatering - Time and Cost Relief by way of Trenchless Construction

Glen Hills Area: Septic System and Public Sewer Q & A Information Sheet Page 1

Collection Systems Technology Fact Sheet Sewers, Conventional Gravity

CHAPTER WAC WATER POLLUTION CONTROL AND ABATEMENT PLANS FOR SEWAGE DRAINAGE BASINS

Nutrient Reduction by Use of Industrial Deep Injection Wells, Miami-Dade County, Florida

SANITARY SEWER BACKUP. Causes & Prevention

ARTICLE II (2) ARTICLE II - REQUIRED USE OF PUBLIC SEWERS. PARAGRAPH Purpose and Application.

PUBLIC FACILITIES ELEMENT SANITARY SEWER SUBELEMENT. Provide an Environmentally Sound Sanitary Sewer System

Addressing Declining Elevations in Lake Mead

Homeowners and Home Buyers Guide to Wells and Private Sewage Systems

How To Calculate An Average Daily Flow

East Niles Community Services District 2010 Urban Water Management Plan

Sanitary Sewer Master Plan

SANITARY SEWER SYSTEM ASSESSMENT

UTILITIES ELEMENT TABLE OF CONTENTS. I. INTRODUCTION 3 1. Growth Management Act Requirements 3 2. Purpose of Utilities Element 3

Executive Director, Engineering & Construction Services Director, Purchasing & Materials Management Division

Town of Yorktown Comprehensive Plan 8. INFRASTRUCTURE

Ponds- Planning, Design, Construction

Georgia Department of Public Health. Georgia Onsite Sewage Management Systems. Background and Use of Onsite Wastewater Treatment Systems in Georgia

ZIONSVILLE WASTEWATER DEPARTMENT 10-YEAR SEWER REHABILITATION REPORT

Codes and High Performance Hot Water Systems. Gary Klein Affiliated International Management, LLC

ABC & C 2 EP Formula/Conversion Table for Water Treatment, Distribution, & Laboratory Exams

Plan Groundwater Procurement, Implementation and Costs, prepared for the Brazos River Authority, July 2005.

APPROVED CONSOLIDATION AGREEMENT BETWEEN THE TOWN OF AMHERST SANITARY SEWER DISTRICTS 1 and 16 REGARDING THEIR CONSOLIDATION INTO A SINGLE DISTRICT

El Paso Water Utilities Public Service Board. Application for Renewal Industrial Wastewater Discharge Permit

Update on Aquifer Storage and Recovery

5. Environmental Analysis

CHAPTER Section 1 Inventory of Existing Sanitary Sewer Collection and Treatment Facilities

* 765 million tons of recoverable reserves as of 1970; W.E. Edmonds, Pennsylvania Geologic Survey

MATHEMATICS FOR WATER OPERATORS

I. Introduction. 10 minutes

Funding for this project provided by Washington Department of Ecology Grants G & G

SECTION 1 PURPOSE AND POLICIES

SANITARY SEWER SPECIFICATIONS

Cost Estimation for Materials and Installation of Hot Water Piping Insulation

Module 9: Basics of Pumps and Hydraulics Instructor Guide

Facing The Challenges In Houston s Water System: Past, Present, and Future

CHECKLIST FOR FILING AN APPLICATION FOR A GROUND AND/OR SURFACE WATER WITHDRAWAL PROJECT IN THE DELAWARE RIVER BASIN

Energy Savings in Water and Wastewater Systems

Development impact fees can also create a strong financial incentive to discourage inefficient land development patterns by:

Land Disturbance, Erosion Control and Stormwater Management Checklist. Walworth County Land Conservation Department

SECTION 6 EXISTING WASTEWATER MANAGEMENT SYSTEMS

Illinois Environmental Protection Agency Division of Water Pollution Control Class K Study Guide Industrial Wastewater Operator Certification

Transcription:

Utility Systems Sanitary Sewer System Plan The Comprehensive Sanitary Sewer Plan is intended to serve as a guide to completing the future sanitary sewer trunk system to serve future development as outlined in the City s Comprehensive Plan. The existing sanitary sewer system for which analysis was developed was the City s existing sanitary sewer system as of December 31, 2005. Analysis for the City s ultimate sewer system was based on the future land use plan as of December 2007. Future development plans or the existing sewer system may have changed since this snapshot in time the report was based on. The existing City sanitary sewer system is a collection system only, Chisago Lakes Joint Sanitary Treatment Commission (CLJSTC) is responsible for treatment. All wastewater flows from the existing City service area are collected through a network of collection mains and flow to the County Road 84 lift station on the eastern City boundary, where they are pumped to the CLJSTC treatment plant for treatment as shown in Figure U-1 (provided by CLJSTC engineer). The existing serviced area within Wyoming comprises 1,800 acres and can be split into twelve (12) different sewer districts based on the location of the existing lift stations and the sewer mains flowing to each lift station. Figure U-1 shows the existing service area, sewer sheds, and City sewer system including lift stations. Although not shown in Figure U-1, the Polaris site is served. A SewerCAD model was used to evaluate the capacity of the existing system. Analysis indicated existing trunk sewer mains have adequate capacity to serve the existing City service area once the area that currently has been extended sewer becomes fully developed, including the Wyoming interceptor. However, lift stations 2 and 7 may not be adequate to serve the existing City service area once it is fully developed. Capacity of the lift station in sewer district 6 should be verified prior to any future development or the addition of flow in sewer districts 6 and 12. The topography of the undeveloped areas (areas to which City sewer service has not been extended) was studied to determine future sewer sheds (districts), subdistricts, and general direction of surface water flow. It was determined that sewer districts generally flow north to Carlos Avery. The intention with designing the future system was to follow the existing ground topography as much as possible in order to minimize the number of trunk lift stations, keep the maximum depth of gravity sewers to less than 40 feet deep, and route sewers through all sub-districts to collect wastewater generated in future developments. Wyoming Comprehensive Plan U-1

Figure U-1 Existing Sanitary Sewer System U-2 Wyoming Comprehensive Plan

The layout of the future trunk sewer system is shown in Figure U-2. The layout is general in nature and exact routing will be determined at the time of final design. It is important that the general concept and sizing be adhered to for assurance of an economical and adequate ultimate system. In addition, additional sewer infrastructure will be required to serve individual developments as proposed by developers not accounted for in this plan because it is assumed it will be funded by developers. Future trunk sewers were designed to flow around the existing City service area because reconstruction of trunk sewers within the City would be more expensive than if constructed with new development. Unfortunately, not all sewers could be routed around the existing service area and flows from the northwest would have to flow through the City because the route is confined by Carlos Avery to the east. Also, the property immediately west of I-35 is anticipated to develop in the near future. Due to its development timing and location relative to the interceptor, future flows were routed through the existing service area. The existing SewerCAD model was expanded to determine the adequacy of the existing system to serve future development where necessary and design the future trunk sewer system. The existing Wyoming interceptor has capacity for approximately 7.0 MGD peak flow, although Wyoming s capacity is not clearly defined at this time. Based on the City s land use plan it will be difficult to define a trigger point as to when additional capacity should be added to this interceptor. Future development will occur due to market demand, therefore the rate and type of development is not possible to project for the ultimate service area. Since ultimate future flows are projected to exceed interceptor capacity, additional interceptor capacity will have to be purchased in the future. Meetings with the CLJSTC s engineer have indicated that when Wyoming has reached its interceptor capacity, CLJSTC will be responsible for adding capacity to serve the remaining future developable acres within Wyoming. Wyoming will be assessed the increased capacity cost by CLJSTC to serve the remaining future development. Future expansion of the sanitary sewer system will be driven by development demand and proximately to the existing sewer system. Based on information provided by the City, a development phasing map was completed as shown in Figure U-3. The map shows the order of likely development or property to which water will be extended due to development demand. Development demand was one of many factors taken into account in developing the ultimate trunk sewer system. Wyoming Comprehensive Plan U-3

Figure U-2 Future Sanitary Sewer System U-4 Wyoming Comprehensive Plan

Figure U-3 Potential Ultiimate Sewer Service Area and Development Pi iti Wyoming Comprehensive Plan U-5

Water System The Comprehensive Water System Plan is intended to serve as a guide to completing the future water system to serve future development as outlined in the City s Comprehensive Plan. The existing water system for which analysis was developed was the City s existing water system as of December 31, 2005. Analysis for the City s ultimate water system was based on the future land use plan as of December 2007. Future development plans or the existing water system may have changed since this snapshot in time the report was based on. The existing municipal water system is shown in Figure U-4 and consists of three wells, two elevated storage tanks, disinfection and fluoridation at each well site, and distribution mains ranging in size from 6 to 16 inches in diameter. The total supply capacity (rated well pumping capacity) of the three wells is 2,125 gpm, and the firm capacity (firm capacity assumes the largest well out of service in the system) of the system is 1,250 gpm. Each well pump discharges into the distribution system after chlorine, fluoride, and polyphosphate addition. System storage includes one 300,000 gallon tower and one 75,000 gallon tower. The 2005 average day water demand was approximately 353,000 gallons per day (gpd) and a maximum day demand of 1,059,000 gallons per day (mgd). An extended period simulation (EPS) computer model (WaterCAD v. 7.0) was used to evaluate the existing system s operating pressures and available fire flow. In addition, the existing system water quality was reviewed. Evaluation of the existing water system indicated: The system is capable of providing adequate supply and pressure during average day, maximum day, and peak hour demands while operating at supply firm capacity. System fire protection (available fire flow) is adequate with the exception of residential areas west of I-35 and north of 272 nd Street, where mains provide less than 1,000 gpm capacity. Well No. 3 radium concentration exceeds MCL. The quantity of future water demands were estimated based on the City s draft Comprehensive Plan. A maximum day to average day demand ratio of 3.0 was used for estimating ultimate system demands. In the past three years, maximum day to average day demand ratios have ranged from 2.7 to 3.5. This ratio is significant in that the maximum day demand and peak hour demand are used in sizing the water supply, treatment, storage, and distribution system for a community. The resulting projected average day and maximum day demands were approximately 4.11 and 12.32 MGD respectively. U-6 Wyoming Comprehensive Plan

City water system needs are met by first providing a water source capable of satisfying a maximum day water demand. When the source water is from groundwater, as is the case in Wyoming, the maximum day demand should be satisfied assuming the largest well is temporarily out service (firm capacity). It is anticipated that approximately 7,000 gpm of additional supply will be necessary to serve Wyoming s ultimate system demands. If each well produces approximately 800 gpm, as the City s geology indicates, 9 new wells would be required. Considering the typical water quality from the region, we anticipate future water supply wells to pump to treatment facilities prior to distribution. Well No. 3 currently exceeds the combined radium MCL, and secondary standards for iron and manganese will most likely be exceeded in future water sources. Therefore, it was assumed that a future water treatment facility would be constructed for removal of radium, iron, and manganese with capacity to treat water from all new supply (7,000 gpm or 10.5 MGD) American Water Works Association (AWWA) standards indicate that water storage should equal 70 to 100% of average day demand or the sum of required fire fighting storage, equalization storage, and reserve storage, whichever is greater as discussed in Section 6. Since projected future average day demands are projected to be greater than future equalization, firefighting, and reserve storage, the average day demand of 4.0 MGD was used for future storage planning. The water distribution system will need to be expanded as development requires service. The future trunk water main system presented in Figure U-4 consists of a 24-inch trunk main loop and several12-inch trunk main loops. The system would provide capacity to distribute water throughout the City from one point, as would be the case for a treatment plant. If treatment is not required of future water sources, and the City decides not to provide treated water to residents, then wells will be scattered throughout the system. The trunk water main system designed in Figure U-5 would be capable of providing adequate fire flow and pressure to residents regardless of how water is supplied. If development occurs quicker than anticipated or in different locations than anticipated, construction phasing can be changed. Since the water system is under pressure there is some flexibility in infrastructure location and additional siting studies can be performed as development progresses. Wyoming Comprehensive Plan U-7

Figure U-4 Existing Water Distribution System U-8 Wyoming Comprehensive Plan

Figure U-5 Future Water Distribution System Wyoming Comprehensive Plan U-9