Correspondence should be addressed to Heinz-Jakob Langen; hj.langen@missioklinik.de



Similar documents
Research Article Inconsistencies Exist in National Estimates of Eye Care Services Utilization in the United States

Received June 18, 2007; Revised August 30, 2007; Accepted August 30, 2007; Published September 17, 2007

Research Article Prevalence of Provocative Seizures in Persons with Epilepsy: A Longitudinal Study at Khon Kaen University Hospital, Thailand

Research Article Attitudes toward Physician-Nurse Collaboration in Pediatric Workers and Undergraduate Medical/Nursing Students

Case Report Chronic Neck Pain Associated with an Old Odontoid Fracture: A Rare Presentation

Research Article Optimizing Transport Time from Accident to Hospital: When to Drive and When to Fly?

Research Article Practice of Pain Management by Indian Healthcare Practitioners: Results of a Paper Based Questionnaire Survey

Clinical Study Minimizing Surgically Induced Astigmatism at the Time of Cataract Surgery Using a Square Posterior Limbal Incision

Case Report Pleural Mesothelioma Presenting as Periumbilical Metastasis: The First Clinical Documentation

Elenco dei periodici elettronici in Ovid Full text

Case Report Laser Vision Correction on Patients with Sick Optic Nerve: A Case Report

Research Article Perspectives from Nurse Managers on Informatics Competencies

Research Article Frequency of Surgery in Black Patients with Malignant Pleural Mesothelioma

2012 Physician Specialty Data Book. Center for Workforce Studies. November Association of American Medical Colleges

Clinical Study The Bristol Hip View: Its Role in the Diagnosis and Surgical Planning and Occult Fracture Diagnosis for Proximal Femoral Fractures

Test Request Tip Sheet

X-ray (Radiography) - Chest

International Journal of Case Reports in Medicine

Case Report Early Bilateral Cystoid Macular Oedema Secondary to Fingolimod in Multiple Sclerosis

Radiologic Technology Associate of Science Degree Program

Objective of This Lecture

Case Report Reconstructive Osteotomy for Ankle Malunion Improves Patient Satisfaction and Function

X-ray (Radiography), Chest

Accredited Schools and Programs

Benefit Summary - A, G, C, E, Y, J and M

Froedtert Hospital School of Radiology Curriculum Analysis Grid. Clinical Practice

XIV ANNUAL MEETING OF NURSING

Radiologic Technology (RAD, CLE) courses are open only to Radiologic Technology majors.

Research Article Analysis of the Power of Common Diagnostic Tools in the Management of Acute Pancreatitis

ASTHMA IN INFANTS AND YOUNG CHILDREN

Why you and your Family Should Get the Flu Shot

How To Become An Xray Technician

League of Women Voters. November 20, 2012

October 17, Elias Zerhouni, M.D. Director National Institutes of Health One Center Drive Suite 126 MSC 0148 Bethesda, MD 20892

Research Article Lung Function Tests in Sickle-Cell Patients in Benin City

CPT Pediatric Coding Updates The 2009 Current Procedural Terminology (CPT) codes are effective as of January 1, 2009.

MGMA PROVIDER COMPENSATION 2015

Bachelor of Applied Science in Emergency Medical Services

ST. ROSE HOSPITAL Job Description

Patient Exposure Doses During Diagnostic Radiography

Maharashtra University of Health Sciences, Nashik. Syllabus. Fellowship Course in Sleep Medicine

Computational Biomarker Discovery in the Big Data Era: from Translational Biomedical Informatics to Systems Medicine


Canadian Paediatric Society

TUBERCULOSIS (TB) SCREENING GUIDELINES FOR RESIDENTIAL FACILITIES AND DRUG

R/F. Efforts to Reduce Exposure Dose in Chest Tomosynthesis Targeting Lung Cancer Screening. 3. Utility of Chest Tomosynthesis. 1.

Remove this cover sheet before redistributing and replace it with your own. Please ensure that DPHHS is included on your HAN distribution list.

Training in Clinical Radiology

PATIENT INFORMATION SHEET Study name: CT morphology of lung parenchyma pre and post bariatric surgery: correlation with pulmonary function.

VACAVILLE MEDICAL CENTER. Staff Navigator

Defending the Rest Basics on Lung Cancer, Other Cancers and Asbestosis: Review of the B-Read and Pulmonary Function Testing

Physician Practice Acquisitions

FACULTY OF ALLIED HEALTH SCIENCES

COMMUNICATING RADIATION RISKS IN PAEDIATRIC IMAGING

Full name/ Title of Medical Qualifications Eligible for Conditional Registration. American Board of Obstetrics and Gynaecology

4. Clinton Memorial Hospital Family Practice Program ACGME#

REPORT TO THE 2015 LEGISLATURE. Report on Findings from the Hawai i Physician Workforce Assessment Project

Home Sleep Testing Common Questions and Answers

Selection of Future Medical Practice: Using the Australian Medical Schools Outcomes Database to inform national workforce planning

Respiratory Concerns in Children with Down Syndrome

Policy and Procedures ACLS & PALS Certification Courses

Pain, Coping and Sleep in Children and Adolescents With Sickle Cell Disease J. Kelly Graves, PhD, RN Eufemia Jacob, PhD, RN

School of Nursing and Midwifery. School of Nutritional Sciences and Dietetics

Parkway College of Nursing and Allied Health School of Nursing and Allied Health. BSc (Hons) Diagnostic Radiography and Imaging Module Synopses

MEDICAL CERTAINTY WITHIN YOUR REACH

X-Ray Technician Limited Scope Registration Application Packet

Society of Nuclear Medicine 1850 Samuel Morse Drive Reston, VA

Proton Therapy. What is proton therapy and how is it used?

Disease/Illness GUIDE TO ASBESTOS LUNG CANCER. What Is Asbestos Lung Cancer? Telephone

The Radiologic Technology Program at Trenholm University

REGULATION: QUALITY ASSURANCE PROGRAMS FOR MEDICAL DIAGNOSTIC X-RAY INSTALLATIONS N.J.A.C. 7:28-22

PEOSH Model Tuberculosis Infection Control Program

Trainee Resources List available on the Learning Management System (LMS)

Correspondence should be addressed to Rebecca Jeanmonod;

All fields on claim form must be completed within the required Sections unless specifically marked as optional on the claim form.

Research Article Average Bandwidth Allocation Model of WFQ

FREQUENTLY ASKED QUESTIONS ABOUT PERTUSSIS (WHOOPING COUGH)

Master of Physician Assistant Studies Course Descriptions for Year I

Imaging Technology. Diagnostic Medical Sonographer, Dosimetrist, Nuclear Medicine Technologist, Radiation Therapist, Radiologic Technologist

Bon Secours St. Mary s School of Medical Imaging Course Descriptions by Semester Class of CRS 101 Clinical Radiation Science 3

J of Evolution of Med and Dent Sci/ eissn , pissn / Vol. 3/ Issue 65/Nov 27, 2014 Page 13575

UNIVERSITY OF KANSAS Office of Institutional Research and Planning

LUNG VOLUMES AND CAPACITIES

Fields of Education. Last updated August 2011

As the Director of The Clinical Center of Excellence at Rutgers University, I am speaking on

Primary Care Pediatric Nurse Practitioner Certification Exam. Detailed Content Outline

Vaccination against pertussis (whooping cough) - the replacement of Repevax with Boostrix -IPV an update for registered healthcare practitioners

MeSH Tree Structures

The Field. Radiologic technologists take x-rays and administer nonradioactive materials into patients' bloodstreams for diagnostic purposes.

UMDNJ New Jersey Medical School

M G 0 0 Admission Number Master of Medicine Programme in Diagnostic Radiology (International Programme)

Medical Registration What does it mean? Who should be registered?

DRAFT. Select VHA ENTERPRISE STANDARD TITLE:??

Juvenile Dermatomyositis Joseph Junewick, MD FACR

Bon Secours St. Mary s Hospital School of Medical Imaging Course Descriptions by Semester 18 Month Program

B e l l i n. S c h o o l R a d i o l o g i c T e c h n o l o g y. Bellin Health School of Radiologic Technology. Bellin Health

Specialty-specific References for DIOs: Expected Time for Program Director ACGME

SUPPLEMENTAL MATERIAL

Medical Radiologic Technology

Healthcare services requiring prior authorisation

Transcription:

Radiology Research and Practice, Article ID 312846, 5 pages http://dx.doi.org/1.1155/214/312846 Research Article Performing Chest X-Rays at Inspiration in Uncooperative Children: The Effect of Exercises with a Training Program for Radiology Technicians Heinz-Jakob Langen, 1 Christiane Kohlhauser-Vollmuth, 2 Corinna Sengenberger, 1 Johann Bielmeier, 1 Renate Jocher, 1 and Martina Eschmann 3 1 DepartmentofRadiology,MedicalMissionHospital,Salvatorstr.7,9767Wuerzburg,Germany 2 Department for Paediatric and Adolescent Medicine, Medical Mission Hospital, Salvatorstr. 7, 9767 Wuerzburg, Germany 3 Department of Nucelarmedicine, Marienhospital Stuttgart, Böheimstr. 37, 7199 Stuttgart, Germany Correspondence should be addressed to Heinz-Jakob Langen; hj.langen@missioklinik.de Received 22 February 214; Revised 23 May 214; Accepted 27 May 214; Published 9 July 214 Academic Editor: Paul Sijens Copyright 214 Heinz-Jakob Langen et al. This is an open access article distributed under the Creative Commons Attribution License, which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited. Objective. It is difficult to acquire a chest X-ray of a crying infant at maximum inspiration. A computer program was developed for technician training. Method. Video clips of 3 babies were used and the moment of deepest inspiration was determined in the single-frame view. 12 technicians simulated chest radiographs at normal video speed by pushing a button. The computer program stopped the video and calculated the period of time to the optimal instant for a chest X-ray. Demonstration software can be tested at website online. Every technician simulated 1 chest X-rays for each of the 3 video clips. The technicians then spent 4 minutes practicing performing chest X-rays at optimal inspiration. The test was repeated after 5, 2, and 4 minutes of practice. Results.6 participants showed a significant improvement after exercises (collective 1). Deviation from the optimal instant for taking an X-ray at inspiration decreased from.39 to.22 s after 4 min of practice. 6 technicians showed no significant improvement (collective 2). Deviation decreased froma low startingvalue of.25s to.21s. Conclusion. The tested computer program improves the ability of radiology technicians to take a chest X-ray at optimal inspiration in a crying child. 1. Introduction In pediatric radiology especially, quality control such as the improvement of chest X-ray examinations is very important [1]. In addition to the technical parameters of quality, the timing for taking an X-ray during breathing is very important for diagnostic evaluation. The main focus in conventional chest X-ray examinations in children is the exclusion or proof of pneumonic infiltration. In particular, chest X-ray examinations in babies and young children demonstrate characteristic changes like infiltration only at deep inspiration [2]. Babies and small children are not able to follow breathing commands. A good chest X-ray examination depends among other things on the ability of the technician to take the X-ray of a potentially crying child at an optimal instant (deep inspiration). The moment for taking an X-ray is very short. The respiratory frequency in an adult is 16 breaths per minute and increases to 8 breaths per minute in an ill infant. That means that the diaphragm moves up and down in less than a second [3]. The goal of this study was to evaluate a training program using a self-developed video game practicing the taking of a chest X-ray at the optimal moment. The improvement of the reaction time using the training program was demonstrated in an earlier study [4]. This study examined how much training time is needed to improve reaction time and whether the improvement is shownforallchildren(i.e.,cryingandsleepingchildren)and in all test subjects. 2. Materials and Method 2.1. Patients. The study involved a training program and a test program containing video clips of different children.

2 Radiology Research and Practice For the study videos were taken with 24 images per second of six children with consent from the parents. The videos of the patients were all obtained in supine position on the examinationtableorinbed.whilefilmingacryinganda sleeping newborn was no problem, it was not possible to find a sporadically crying newborn. Therefore videos were taken of an older child for that breathing type. In detail, video clips were taken of a regularly crying (meaning that the duration of a respiratory cycle during the investigated time remains the same) 25-day-old newborn (training child 1), a sporadically crying (meaning that the duration of a respiratory cycle duringtheinvestigatedtimedoesnotremainthesame)17- month-old child (training child 2), and a sleeping 8-dayold newborn (training child 3). Additionally, to evaluate the training outcome, a test program was created. Therefore videos were taken of a regularly crying 6-month-old infant (test child 1), a sleeping 5-month-old infant (test child 2), and a sporadically crying 15-month-old child (test child 3). 2.2. Computer Program. With a video editing program (MAGIX Video Deluxe 26 plus) in video clips with a duration of 36 (training child 1), 22 (training child 2), and 11 (training child 3) seconds, and 47 (test child 1), 42 (test child 2), and 47 (test child 3) seconds, the moment of the deepest inspiration was visually determined using the single-frame view. A computer program allowed stopping of the normal running video with the push of a button connected to the computer by a USB plug. The video stopped with a delay of.6 s corresponding to the standard technical delay when taking an X-ray from the prepare mode. The delay in the computer program can be changed according to the different X-ray devices. After the video was stopped, the computer program calculated the period of time from the stopping of the video to the moment of a chest X-ray of optimal inspiration. When the video was stopped too early, the period of time to the optimal moment got a negative sign. If the video was stopped too late, the sign was positive. In the background theperiodoftimewascalculatedwithaprecisionofnearly.4 seconds approximately corresponding to the duration of one picture at 24 pictures per second (Figure 1). The computer program was created using the computer language Delphi (Embarcadero Technologies; San Francisco; Version Delphi 27 for Win32. A free video player (mplayer; Download: http://www.mplayerhq.hu; Version: 1.Opre8-3.4.2) was also used. Demonstration software of the training program for radiology technicians can be tested at the website http://www.tprt.de/. 2.3. Test Setting. Test subjects included twelve pupils from the school for radiology technicians in the second and third year of training without experience in pediatric radiology. Test subjects number 5 and number 12 were male. All others were female. First a baseline test (test 1) was performed with all 12 test subjects. Therefore, each test subject simulated 1 chest X-rays for each of the 3 test video clips. If a video clip ended before completion of the 1 simulations, the video was started again. In the background the deviation from the optimal moment for an X-ray at inspiration was recorded. Afterwards Figure 1: Frozen frame after simulation of a chest X-ray in a crying infant (17-month-old child) (training child 2) after the space bar is pressed. The center of the image shows that the running video was stopped.8 s too late for an X-ray at deepest inspiration. the test subjects used the training videos to practice taking X-rays at optimal inspiration in a manner similar to playing a computer game. During the exercise the period of time to the optimal instant was shown to the test subjects after every simulated X-ray. The test was repeated after 5 minutes (test 2) and additional 15 minutes (test 3). 2 to 5 days after the first exercise day, the test subjects trained again for 2 minutes before testing (test 4). Following a training break of one week, the final test (test 5) was conducted without prior training to demonstrate the long-term effects of the trainingprogram. Changeswereevaluatedusingthet-test for independent samples and the Dunnett test [5]. A P value <.5 was considered to be significant. The period of time to the optimal instant is recorded as mean of the absolute values withoutsigns± standard deviation. 3. Results Initial evaluations showed a significant interindividual difference in the results of the test subjects. Some of the test subjects demonstrated an important improvement due to the training, while others scored well from the beginning but showed only minimal improvement. To demonstrate the different effects of the training program in both groups, the test subjects were divided in 2 groups. 6 test subjects, who showed significant improvement in the regularly crying child based on the ttest for independent samples, were summarized in collective 1. The other 6 test subjects without significant improvement were summarized in collective 2. In collective 1 the test subjects missed the moment for an X-ray at maximal inspiration by.39 (±.35) s in test 1 while thedeviationwas significantlyreducedto.22 (±.26) s after training in test 4 (P <.1). In collective 2 the deviation changed from.25(±.26)s in test 1 to.21 (±.14) s after training in test 4. The changes were not significant (Dunnett test P =.125)(Figure 2). The greatest improvement in accuracy was demonstrated after only 5 minutes of training and increased after further

Radiology Research and Practice 3.45.4.35.3.25.2.15.1.5 Collective 1 Collective 2 Tests 1 5 Figure 2: Deviation from the optimal inspiration moment in seconds in test 1 before training and in tests 2 to 5 after training in collective 1 and 2..5.45.4.35.3.25.2.15.1.5 Tests 1 5 Child 1 Child 2 Child 3 Figure 4: Deviation from the optimal inspiration moment in seconds for child 1 (regularly crying), child 2 (sleeping), and child 3 (sporadically crying) in test 1 before training and in tests 2 to 5 after training in collective 1..4.35.3.25.2.15.1.5 Collective 1 Collective 2 Tests 1 5 Figure 3: Standard deviation in seconds in test 1 before training and in tests 2 to 5 after training in collective 1 and 2. training compared to test 1. In collective 1 the deviation from the optimal instant decreased from.39 (±.35) s in test 1 to.31 (±.37) s in test 2 (P =.4) to.27(±.28) s in test 3(P =.1) andto.22(±.26) s in test 4 (P <.1). In collective 2 the changes were not significant at the high starting point. The mean deviation from the optimal instant was.25 (±.26) s in test 1,.25 (±.18) s in test 2,.22 (±.15) s in test 3, and.21 (±.13) s in test 4 (Figure 2). The mean standard deviation decreased as a result of training in both collectives (Figure 3). The greatest improvement in accuracy was shown in the regularly crying infant (test child 1). In collective 1 the deviation from the optimal instant decreased on average from.44 (±.34) s in test 1 to.15 (±.14) s in test 4 (P <.1). The most significant changes were demonstrated after only 5 minutes of training with a mean deviation from the optimal instant of.44 (±.34) s in test 1 to.26 (±.2) s in test 2 (P <.1). Also significant was the improvement from.22 (±.17)s in test 3 to.15 (±.14) s in test 4 (P =.8). Test child 2, the sleeping child, resulted in the least improvement in the mean deviation from the optimal instant from.36 (±.41) s in test 1 to.31 (±.39) s in test 4. The changes however were not significant in this child. Test child 3, the sporadically crying infant, also yielded insignificant improvement in the mean deviation from the optimal instant from.37 (±.28) s in test 1 to.22 (±.16) s in test 4. The greatest changes were seen from test 1.37 (±.28) s to test 2.29(±.27) s and from test 3.28 (±.2) s to test 4.22 (±.16) s. However, the changes were not significant (Figure 4). In collective 2 the smallest deviation from the optimal instant for an X-ray was seen in the regularly crying infant (test child 1). The mean deviation changed from a lower starting point of.13 (±.1) s in test 1, not significant, to.15 (±.11) s in test 4. In test child 2 (sleeping child), the mean deviation improved from.36 (±.35) s in test 1 to.3 (±.16) s in test 4. These changes were also not significant. In test child 3 (sporadically crying infant), the mean deviation improved significantly (P =.21)from.24(±.21) s in test 1to.17(±.9) s in test 4 (Figure 5). The training program also yielded long-term effects as evidenced by the results from test 5 which were performed after a training break of one week. In collective 1 the mean deviation from the optimal instant for an X-ray for all three children of.22 (±.26) s in test 4 and.22 (±.16) s in test 5showednosignificantchange.Incollective2thechangeof themeanvaluefrom.21(±.14) s in test 4 to.22 (±.16) s in test 5 was also not significant (Figure 2).

4 Radiology Research and Practice.4.35.3.25.2.15.1.5 Test 1 5 Child 1 Child 2 Child 3 Figure 5: Deviation from the optimal inspiration moment in seconds for child 1 (regularly crying), child 2 (sleeping), and child 3 (sporadically crying) in test 1 before training and in tests 2 to 5 after training in collective 2. 4. Discussion Conventional chest X-rays are commonly used in children, especially in the neonatal and pediatric intensive care units. Since conventional X-ray diagnosis provides valuable information with minimal radiation exposure and relatively low costs, it is the foundation for further imaging methods such as fluoroscopy, MRI, or CT [6, 7]. Deep inspiration results in a better chest X-ray, with a better evaluation of the lung parenchyma [2]. Inadequate inspiration leads to condensation of the lung structures, which can simulate pathological findings [8].Whileadultstakeadeepbreathon demand and stop breathing when the chest X-ray is taken, this is not the case in small children and babies. Nearly half of the children requiring a chest X-ray are of an uncooperative age [6]. Radiology technicians have to estimate when the child will reach the moment of maximal inspiration during the respiration cycle. The diaphragm passes through the whole respiration cycle in 1.5 seconds or less if the respiration frequency reaches 6 breaths per minute or higher. In a crying child a diaphragm speed up to 1 mm/s is possible [6]. The radiology technician has a very limited opportunity to correctly estimate the optimal moment for a chest X-ray [2]. Despite the high importance of good chest X-rays in babies and small children and the difficulties regarding taking a chest X-ray at the moment of deepest inspiration, we only know of one study addressing improvement of this issue. Claesson and Olsson [9] used transthoracic impedance as a triggering device for chest X-rays. Although they reported good results, this technique was not developed further. Experienced radiology technicians advise trainees to breath with the child in order to determine the point of deepest inspiration for the chest X-ray more exactly. The newly developed program makes a positive contribution, especially for inexperienced radiology technicians and trainees. They can optimize their technique without radiation exposure. On average all test subjects improved their accuracy during the tests as a result of training. However, the changes were significant only in collective 1 (subjects who showed significant improvement in the regularly crying child). This may be due to the fact that the test subjects in collective 2 (subjects without significant improvement in the regularly crying child) began with better performance and therefore only minimal improvement was possible. Probably the test subjects in collective 2 had such a good reaction and learning capacity that they understood after the first introduction how to determine the optimal instant for a chest X-ray at inspiration. However, the training program was also useful in this subgroup because the accuracy improved even if not significantly. The program provided the greatest benefit to the test subjects of collective 1. The initial accuracy achieved by this subgroup improved significantly due to training. After training the smallest deviation from the optimal moment to take a chest X-ray was achieved in the regularly crying child. The test subjects were probably better able to adjust to regular breathing and to take the optimal moment more reliable than to the quick breathing of the sleeping infant. The results correlate well with an earlier study [4]. In ourstudytheworseresultswereseeninthesleepingchild followed by the sporadically crying child. It is conceivable that X-rays can be taken more exactly at inspiration in this subgroup if the child is made to cry at regular intervals by uncomfortable stimulus. However, the moment of deepest inspiration is also determined more exactly after training in a sporadically crying child, but the results were clearly worse compared to the regularly crying children. In most of the cases a decrease in the standard deviation was shown after training. This means that the test subjects achieved the optimal instant for a chest X-ray with higher accuracy and the number of outliers decreased. The greatest improvement in the deviation from the optimal instant to take a chest X-ray was seen after only 5 minutes of training. However, even after 4 min of training, smaller sometimes significant improvements can be demonstrated. The training time required for the test subjects to reach their optimal performance varies greatly. A fixed training time cannot be recommended. Every test subject needs to practice until maximum ability to take a chest X-ray at deepest inspiration has been reached. The good news is that these skills are retained for a substantial period of time. 5. Conclusion In summary the tested training program helps radiology technicians improve their ability to take a chest X-ray at the optimal instant of deepest inspiration. The degree of improvement is very different and depends on individual learning and reaction skills. Since the greatest improvements are already demonstrated after 5 minutes, the training program is particularly useful for radiology technicians with little experience taking chest X-rays in children in order to improve quality and diagnostic reliability. Further studies with evaluation of X-rays are necessary to prove the hypothesized improvement in the diagnostic reliability of chest X-rays as a result of time optimization caused by the training program.

Radiology Research and Practice 5 Disclosure Demonstration software of the training program for radiology technicians can be tested at the website http://www.tprt.de/. Conflict of Interests The authors declare that there is no conflict of interests regarding the publication of this paper. References [1] C. D. Alt, D. Engelmann, J. P. Schenk et al., Quality control of thoracic X-rays in children in diagnostic centers with and without pediatric-radiologic competence, Fortschr Röntgenstr, vol. 178, no. 2, pp. 191 199, 26. [2] R.T.Bramson,N.T.Griscom,andR.H.Cleveland, Interpretation of chest radiographs in infants with cough and fever, Radiology,vol.236,no.1,pp.22 29,25. [3] N.T.Griscom,M.E.B.Wohl,andJ.A.KirkpatrickJr., Lower respiratory infections: how infants differ from adults, Radiologic Clinics of North America,vol.16,no.3,pp.367 387,1978. [4]H.J.Langen,C.Kohlhauser-Vollmuth,S.Muras,M.Stenzel, and M. Beer, Training program for radiologic technologists for performing chest X-rays at inspiration in uncooperative children, Fortschr Röntgenstr,vol.181,no.3, pp.237 241,29. [5] C. W. Dunnett, A multiple comparison procedure for comparing several treatments with a control, the American Statistical Association,vol.5,no.272,pp.196 1121,1955. [6] F. Ball, Untersuchungstechnik und röntgenanatomie der thoraxorgane, in Kinderradiologie 2, W. Schuster, D. Färber, F. Ball et al., Eds., pp. 1 34, Springer, Berlin, Germany, 199. [7] K. Schneider, Radiographic technique and radiation protection in paediatric radiology. Part 1 radiography and fluoroscopy, Radiologie Up2date, vol. 3, pp. 239 249, 26. [8] D. L. Hobbs, Chest radiography for radiologic technologists, Radiologic Technology,vol.78,no.6,pp.494 519,27. [9] I. Claesson and T. Olsson, Experiences with triggered pulmonary exposures in children, Pediatric Radiology, vol. 4, no. 3, pp. 139 143, 1976.

MEDIATORS of INFLAMMATION The Scientific World Journal Gastroenterology Research and Practice Diabetes Research International Endocrinology Immunology Research Disease Markers Submit your manuscripts at BioMed Research International PPAR Research Obesity Ophthalmology Evidence-Based Complementary and Alternative Medicine Stem Cells International Oncology Parkinson s Disease Computational and Mathematical Methods in Medicine AIDS Behavioural Neurology Research and Treatment Oxidative Medicine and Cellular Longevity