2006-2009 IPC Code Review



Similar documents
Amendments to the 2012 International Plumbing Code

Brian Coppock, Regional Compliance Officer. Office of Statewide Health Planning and Development Facilities Development Division

PLUMBING ROUGH IN INSPECTION

WELCOME INTERNATIONAL RESIDENTIAL CODE 2009 EDITION PLUMBING SECTION

Plumbing Installations. A homeowner guide to the City of Winnipeg plumbing requirements for a single-family dwelling

What to Expect From the Examination. How to Study the Plumbing Codes

Georgia State Amendments to the International Plumbing Code

Plumbing Installations A homeowner guide to the City of Winnipeg plumbing requirements for a single-family dwelling

2006 Codes. Please verify the following before calling for inspection

CONSTRUCTION CHECKLIST Residential Plumbing Rough-In September 2004

When Should Examination Preparation Begin?

Plumbing Code Sections For Commercial Food Facilities

Top 10+ Mistakes of DWV plumbing design

Plumbing. Helpful Hints Residential Construction. Lincoln County. Bert Polk Plumbing Inspector

CHAPTER 11 STORM DRAINAGE

ONE AND TWO FAMILY DWELLINGS Plumbing July, 2007

INSPECTION CHECKLIST Residential Plumbing Rough In April 2011 Mercer Island Mill Creek Sammamish Snohomish County Snoqualmie Woodinville

Land Use and Environmental Service Agency (Code Enforcement) NC Plumbing Code. Table of Contents

Dominic i Barbato Dpt. Of Building and Safety (818) domenico.barbato@lacity.org

CHAPTER 11 STORM DRAINAGE

Chapter PLUMBING CODE

WHITE PLAINS PLUMBING CODE PART 1. GENERAL REQUIREMENTS

Residential Plumbing BCN 1058

PLAN CHECK CORRECTION SHEET FOR PLUMBING SYSTEMS 2014 LAPC

Element D Services Plumbing

Plumbing Code in Commercial Kitchens. NH BOA May 9, 2012

Does Part of My Basement Floor Have to Be Removed to Install. Where Does the Water from the Sump Pump Go?...Page 5

PMA ONLINE TRAINING Venting for Plumbing Systems

DENVER PUBLIC SCHOOLS DESIGN AND CONSTRUCTION STANDARDS This Standard is for guidance only. SECTION PLUMBING SPECIALTIES

THE PEOPLE OF THE CITY OF LOS ANGELES DO ORDAIN AS FOLLOWS: Section 1. Article V of Chapter XII of the Los Angeles Municipal Code is added to read:

Georgia State Amendments to the International Plumbing Code

SECTION 5 - COMMERCIAL CONSTRUCTION MECHANICAL, ELECTRICAL, PLUMBING AND SOLAR OTHER TECHNICAL CODES

6. Principles of effective plumbing systems

Isometric Plumbing Drawings

2014 Oregon Plumbing Specialty Code New Oregon Amendments

CITY of LOS ANGELES DEPARTMENT of BUILDING and SAFETY

Plumbing Code. City of San Diego 2013 Plumbing Regulations - Proposed Code Changes (revised 5/15/15)

CHAPTER 10 TRAPS, CLEAN-OUTS, AND INTERCEPTORS

CALIFORNIA PLUMBING CODE MATRIX ADOPTION TABLE CHAPTER 8 - INDIRECT WASTES

CHAPTER 9 VENTS. copper drainage tube Type DWV, Schedule 40 plastic piping, or borosilicate glass.

2006 IPC INTERNATIONAL PLUMBING CODE AMENDMENTS PLANNING & DEVELOPMENT SERVICES DEPARTMENT

ARTICLE II (2) ARTICLE II - REQUIRED USE OF PUBLIC SEWERS. PARAGRAPH Purpose and Application.

DIVISION 22 PLUMBING PLUMBING EQUIPMENT Domestic Water Heaters

Applications for building permits will not be reviewed until all of the required information has been submitted.

Page 1 of 51 Exterior Plumbing Quiz Part 1

2012 British Columbia Plumbing Code Update

APPENDIX A RECOMMENDED RULES FOR SIZING THE WATER SUPPLY SYSTEM

Georgia State Amendments to the International Plumbing Code

GENERAL REGULATIONS CHAPTER 3

Understanding and Designing Plumbing Systems

Editorial Note: bold and underline denotes added text, strikethrough denotes deleted text

INTERNATIONAL RESIDENTIAL PLUMBING CODE

How To Make A House Safe

R432. Health, Health Systems Improvement, Licensing. R Nursing Facility Construction. R Legal Authority. R Purpose.

Arapahoe County Residential Water Heater Installation and Inspection Guide

2-1 TITLE 7 CONSTRUCTION REGULATIONS 2-4

6u!qwnld IDUO!,DUJa'UI I 900~ all' uo pasdh I I

Does Wall Township require an inspection by the building department on resale of a home?

How To Get A Building Permit In Florida

City of Hillsboro Inflow and Infiltration Elimination Program

Inspection Item COMMENTS

CHAPTER 26 PLUMBING CODE

(1) (a) through (1) (e) (iv) Remain the same.

ARTICLE 16. PLUMBING CODE

Plumbing Apprenticeship Program Curriculum

PROPOSED Plumbing Fee Ordinance Amendment

SAN JACINTO RIVER AUTHORITY GUIDANCE DOCUMENT FOR SIZING AND INSTALLATION OF GREASE TRAPS, INTERCEPTORS AND SEPERATORS

INTERCEPTORS TABLE OF CONTENTS S-WD-INTER

PLUMBING. For HOME OWNERS

UNIFORM PLUMBING CODE and UNIFORM PLUMBING CODE STANDARDS Edition

Plumbing Code in Commercial Kitchens

STANDARD PLUMBING AND DRAINAGE REGULATION 2003

Oregon Plumbing Rule and Law RV

WATER & SEWER SERVICES

Plumbing Code Statutes and Regulations February 2011 Labor Standards and Safety Division Mechanical Inspection

CHAPTER 10 TRAPS AND INTERCEPTORS

GUIDANCE DOCUMENT FOR SIZING AND INSTALLATION OF GREASE TRAPS AND INTERCEPTORS

PLAN REVIEW SERVICES CONSTRUCTION DOCUMENTS NECESSARY FOR A THOROUGH PLAN REVIEW

Plugging Home Drains to Prevent Sewage Backup

Apprenticeship Curriculum Standard. Plumber. Level 2. Trade Code: 306A

SOUTHERN NEVADA AMENDMENTS TO THE 2009 UNIFORM PLUMBING & MECHANICAL CODE

DIVISION 22 PLUMBING PLUMBING EQUIPMENT Domestic Water Heaters

Fats, Oil and Grease. Best Management Practices Manual. Information, Pollution Prevention, and Compliance Information For Food Service Facilities

2016 BUILDING PERMIT FEES*

Division A. Compliance, Objectives and Functional Statements

SECTION 105 PERMITS. 2. Fences not over 6 feet (1829 mm) high. 3. Oil derricks.

CHAPTER 9 VENTS TRANSPORTATION OF SEWER GAS

2010 Residential Water Heater Replacement Check List

Chapter 19 PLUMBING CODE

Subpart 1. Installation. All plumbing systems must be. installed and tested according to this chapter and chapter 4715,

The Plumbing Pipeline

Minimum Housing and Health Standards

To many people, a home s plumbing system is perceived as being extremely

PLUMBING CODE REQUIREMENTS AND SIZING GUIDE FOR RESIDENTIAL WATER SOFTENERS. Second Edition. Prepared by

Transcription:

RBC306.2 Scope. The Plumbing Code shall apply to the erection, installation, alteration, repair, relocation, replacement, addition to or use of plumbing systems within the Jurisdiction. The Regional Building Department yields jurisdiction over to the local purveyors for matters and inspections relating to water and sewer services at a point 30inches beyond the exterior walls of the structure, or the water meter, as well as interceptor and separator requirements. In the event no purveyor exists Regional Building Department will assume jurisdictional responsibilities as set out in this code Additions, alterations, repairs and replacement of plumbing systems shall comply with the provisions for new systems. REBUTAL, the newly proposed wording is not necessary, it will have a negative impact on the code. Yielding jurisdiction to local purveyors does not mean that minimum code will be enforced. Independent purveyors may have standards that do not meet minimum code. RBC306.2.1 Repairs and Alterations. RBC306.2.1.1 In existing buildings or premises in which plumbing installations are to be altered, repaired or renovated; deviations from the provisions of the Plumbing Code are permitted, provided such deviations are found to be necessary and are first approved by the Building Official. RBC306.2.1.2 All openings into a drainage or vent system, excepting those openings to which plumbing fixtures are properly connected or which constitute vent terminals, shall be permanently plugged or capped in an approved manner, using the appropriate materials required by the Plumbing Code. REBUTAL, this amendment is covered RBC 104.2. and 104.7 RBC306.2.2 Existing Construction. No provision of the Plumbing Code shall be deemed to require a change in any portion of a plumbing or drainage system or any other work regulated by the Plumbing Code in or on an existing building or lot when such work was installed and is maintained in accordance with the law in effect prior to the effective date of the Plumbing Code, except when any such plumbing or drainage system or other work regulated by the Plumbing Code is determined by the Building Official to be in fact dangerous, unsafe, unsanitary or a nuisance and menace to life, health or property. REBUTAL, this amendment is covered in RBC 104.5. RBC306.2.3 Conflicts between codes. When the requirements of the Plumbing Code conflict with the requirements of other codes in matters pertaining to plumbing, the Plumbing Code shall prevail REBUTAL, amendment not necessary, this was applicable when the Uniform Plumbing Code was in affect, and is covered in 301.7. RBC306.3 Code adopted by reference. There is hereby adopted by reference the International Plumbing Code of the International Code Council, Inc, 4051 West Flossmoor Road, Country Club Hills, Il; 60478-5795, 2003 edition. Three copies of the Code are now filed in the office of the Clerk of the Jurisdiction and may be inspected during regular business hours. The Code is being adopted as if set out at length, to include appendices B, D, E and F, save and except the following which are declared to be non-applicable and therefore expressly deleted: 1. Chapter 1, Administration except Section 107 2. Chapter 5, Water Heaters. 3. Chapter 12, Special Piping 4. Appendices A, C, D, and G. REBUTAL, appendix D is required because it gives us the climatology for this region regarding freeze protection. Appendix G (Vacuum Drainage Systems) is a new technology now being used in remodels, needs rewritten.

RBC306.4 Additions and modifications. The adopted Code is subject to the following additions and modifications: REBUTAL, this amendment will not be needed by eliminating the next amendment. RBC306.4.1 Section 201.3 Terms defined in other codes. Delete ICC Electrical Code and replace with National Electrical Code. REBUTAL, not necessary to amend, because the RBC adopts the NEC. RBC306.4.3 Section 301.6 Prohibited locations. Delete the exception and replace with the following: Exception: Floor drains; sumps and sump pumps shall be permitted at the base of the shaft and shall discharge to the storm drain or exterior of the structure. REBUTAL, the 2009 rewrites this section and is now covered in section 301.6. RBC306.4.4 Table 303.4 Delete table 303.4 and replace with the following: PRODUCTS AND MATERIALS REQUIRING THIRD-PARTY TESTING AND THIRD PARTY CERTIFICATION PRODUCT OR MATERIAL Potable water supply system components and potable water fixture fittings THIRD-PARTY CERTIFIED THIRD-PARTY TESTED Sanitary drainage and vent system components Waste fixture fittings Storm drainage system components Plumbing fixtures Plumbing appliances Backflow prevention devices Water Distribution system safety devices Special waste system components Plastic pipe, fittings and pipe related components Plastic pipe, fittings and pipe related components Plastic pipe, fittings and pipe related components All others All others All other REBUTAL, this table is amended for Plumbing Fixtures and Special Wastes. Asking for Third Party Certified is more than minimum code and conflicts with products currently available on the market today. RBC306.4.5 Section 305.5 Pipes through or under footings or foundation walls. Delete the last sentence and replace with the following: The minimum annular space between the pipe and the sleeve shall be 1/2 inch. REBUTAL, not necessary to amend and redefine for ½. Current verbage of two pipe sizes is not restrictive.

RBC306.4.9 Table 308.5 Hanger spacing. Add footnote c reading: c. 4 inch and smaller cast iron pipe shall be supported at every joint, pipe larger than 4 inch, at every other joint. REBUTAL, too restrictive. Footnote A allows ten-foot intervals, conflicting with this amendment, not necessary to support every joint on piping less than 4 inch. RBC306.4.8 Section 308.6 Sway bracing. Delete in its entirety. REBUTAL, (rewrite), amend to read, for pipe sizes greater than 4. This would typically apply to roof drainage, where larger piping filled with water could create issues with support. RBC306.4.11 Section 310.1 Light and ventilation. Delete in its entirety. REBUTAL, this section is referenced to the applicable Building and Mechanical Codes, not necessary to amend. RBC306.4.17 Section 312.1.1 Test gauges. Delete items 1, 2, and 3, replace with the following: Test pressure gauge scales shall be graduated over a range of not less than one and one-half times and not greater than four times the maximum test pressure. Gauge increments shall be no greater than one pound for tests of 10 pounds or less nor greater than 2 pounds for tests over 10 pounds. REBUTAL, (rewrite), delete items 1,2 and 3, replace with the following: 1. Tests requiring a pressure of 10 pounds per square inch (psi) (69kPa) or less shall use a 30 pound gage or less, but not less than the test pressure. 2. Tests requiring a pressure greater than 10 psi but not greater than 100 psi (689kPa) shall use a 100 pound gage or less, but not less than the test pressure. RBC306.4.18 Section 312.2 Drainage and vent water test. Add an exception to read: Exception: An underslab plumbing base inspection may be tested with no less than a 5-foot head of water. REBUTAL, (rewrite) as follows: In the section paragraph, replace each reference to 10-foot head of water, with 5-foot head of water. RBC306.4.19 Section 312.4 Drainage and vent final test. Delete in its entirety REBUTAL, not necessary to amend, there is no conflict with this section. Smoke testing may be necessary in some work scopes. RBC306.4.21 Section 312.6 Gravity sewer test. Delete in its entirety. REBUTAL, not necessary to delete. This code section applies to piping outside the bldg. and gives guidance to the authority having jurisdiction. RBC306.4.22 Section 312.7 Forced sewer test. Delete in its entirety. REBUTAL, do not delete. This section would be necessary for piping systems that cannot gravity drain. Appendix (G). 312.9 Shower liner test. Where shower floors and receptors are made water-tight by the application of materials required by Section 417.5.2, the completed liner installation shall be tested. The pipe from the shower drain shall be plugged water tight for the test. The floor and receptor area shall be filled with potable water to a depth of not less than 2 inches (51 mm) measured at the threshold. Where a threshold of at least 2 inches (51 mm) high does not exist, a temporary threshold shall be constructed to retain the test water in the lined floor or receptor area to a level not less than 2 inches (51 mm) deep measured at the threshold. The water shall be retained for a test period of not less than 15 minutes, and there shall not be evidence of leakage. REBUTAL, delete this section. This testing is labor intensive, not conducive to cold weather, and local history reflects no need to begin testing shower pan liners.

RBC306.4.23 Section 312.10 Inspection and testing of backflow prevention assemblies. Delete in its entirety. REBUTAL, the code section is necessary do not delete. Enforcement is conducted by State or local water purveyor. RBC306.4.24 Section 314 Condensate disposal. Delete in its entirety. REBUTAL, not necessary to delete, this code section is referenced to the Mechanical Code. RBC303.4 Section 402.1 Quality of fixtures. Add a new sentence at the end of the section to read: Plumbing fixtures shall be provided with an adequate supply of potable water to flush and keep the fixtures in a clean and sanitary condition. Exception: Floor sinks and floor drains. REBUTAL, amendment not necessary. Adequate supply of water is covered in 602.3.2, and flushing of the fixture is in the standards. RBC306.4.27 Table 403.1 Add the following exceptions after the footnotes: Exception: 1. Bar sinks may be substituted for drinking fountains 2. A service sink and drinking fountain are not required if separate facilities are not required for each gender. 3. Building categories not shown on this table shall be considered separately by the Building Official. REBUTAL, (rewrite), remove item 1 from the amendment. Bar sinks are typically not public accessible, other options available in 410.1. RBC306.4.28 Section 405.3.1 Water closets, urinals, lavatories and bidets. Add an exception to read as follows: Exception: Lavatory sidewall clearance may be reduced to 12 in R-3 occupancies. RBC306.4.29 Section 405.3.2 Public lavatories. Add an exception to read Exception: E I- 4occupancies. REBUTAL, amendment not necessary. This code section only applies to toilet rooms accessed by public, or employee s. Optional design is available to restrooms outside this occupancy class. RBC306.4.31 Section 406.1 Approval. Delete in its entirety. REBUTAL, amendment not necessary, industry complies with standard. RBC306.4.33 Section 409.1 Approval. Delete in its entirety. REBUTAL, amendment not necessary, industry complies with standard. RBC306.4.34 Section 410.1 Approval. Delete the last sentence. REBUTAL, delete amendment. The last sentence only substitutes 50% of the required. If only one fountain is needed, no substitutes are allowed. RBC306.4.36 Section 413.1 Approval. Delete the first and second sentences REBUTAL, amendment not needed, industry complies with the standard. RBC306.4.37 Section 416.2 Cultured marble lavatories. Delete in its entirety. REBUTAL, amendment not needed, industry complies with standards, administrative authority can approved alternative. RBC306.4 Add new section to read: Section 417.7 Receptor drains. An approved flanged drain shall be installed with the shower subpans or linings. The flange shall be placed flush with the subbase and equipped with a clamping ring or other device to make a water-tight connection between the lining and the drain. The flange shall have weep holes into the drain. REBUTAL, amendment not necessary, this is covered in section 417.5.2, and also by using a listed fitting assembly.

RBC 306.4 Section424.5 Bathtub and Whirlpool Bathtub Valves. Add an exception to read: Exception: Bathtubs that do not have a fixed or personal shower. REBUTAL, I respectfully (disagree). This is a life-safety issue. Do not amend. RBC306.4.41 Section 602.3.3 Water quality Delete the words, prior to connection to the plumbing system in the last sentence. REBUTAL, the code intent is to supply potable water. Administrative authority assumes the water quality is potable, until proven otherwise, amendment not needed. RBC306.4.42 Section 602.3.4 Disinfection of system. Delete in its entirety. REBUTAL, administrative authority assumes the water quality is potable, until proven otherwise, amendment not needed. RBC306.4.43 Section 602.3.5 Pumps Delete the last two sentences. REBUTAL, amendment not necessary. This code section references antiquated systems, industry uses submersible pump types. RBC306.4.44 Section 602.3.5.1 Pump enclosure Delete the first sentence REBUTAL, amendment not necessary. This code section references antiquated systems, industry uses submersible pump types. RBC306.4.45 Section 604.2 System interconnection. Delete in its entirety. REBUTAL, deleting this section would allow any type of interconnection, where generally speaking the concern is for only one specific recirculating device, which is installed on existing systems and is not necessary to permit. RBC306.4.47 Section 604.9 Water hammer. Add exception: Exception: Single family dwellings. REBUTAL, residential appliance industry addresses the issue with slow closing valves on dish & clothes washers. Ice-maker lines are only ¼ and do not cause issues. RBC306.4.48 Section 605.5 Fittings. Delete the sentence reading: The fittings shall not have ledges, shoulders or reductions capable of retarding or obstructing flow in the piping REBUTAL, 2009 rewritten, amendment not necessary. RBC306.4.49 Section 605.9 Prohibited joints and connections. Delete item #4. Saddle type fittings. REBUTAL, (disagree) with amendment. Saddle type fittings usually found on icemaker and humidifier installations. Installers have solderless options like shark bite fittings. Saddle type not usable on pex piping. RBC306.4.50 Section 606.1 Location of full open valves. Change item # 4 to read: 4. On the floor branch of every water riser pipe in occupancies other than multiple-family residential occupancies that are two stories or less in height and in one and two family residential occupancies Add item #9 to read: 9. On the water supply pipe to each irrigation system REBUTAL, (rewrite), delete item #4, amendment too hard to define. Keep item #9. RBC306.4 Section 606.3 Access to valves. Delete the sentence and insert: Access shall be provided to al required shutoff valves. REBUTAL, not necessary to redefine, current wording is adequate, amendment not necessary. RBC306.4.53 Section 607.2.1 Piping insulation. Add exception. Exception: Where the circulating hot water system pump is controlled by an integral timer. REBUTAL, this is driven by the IECC. Not amendable here.

RBC306.4.56 Section 608.15 Add an exception to read: Exception: Faucets with hose attached sprays in R occupancies shall be protected at the water supply entry with an approved backflow prevention device. REBUTAL, industry complies with code section. Covered in section 424.6, amendment not necessary. RBC306.4.59 Section 608.17. Protection of individual water supplies. Add a period after the word contamination, delete the rest of the sentence and section. REBUTAL, need to delete the entire section. This is covered by County & State. RBC306.4.60 Section 610 Disinfection of potable water system. Delete in its entirety. REBUTAL, the code intent is to supply potable water. Administrative authority assumes the water quality is potable, until proven otherwise, amendment not necessary. RBC306.4.61 Section 701.2 Sewer required. Delete the words in accordance with the International Private Sewage Disposal Code. REBUTAL, reference to Disposal Code is implied, if one is not available or currently in use, amendment not needed. RBC306.4.70 Section708.3.2 Building Sewers Delete in its entirety. REBUTAL, code section is implied if one is not available or currently in use. Covered by local purveyor. RBC306.4.73 Section 708.3.6 Manholes. Delete in its entirety. REBUTAL, code section is implied if one is not available or currently in use. Covered by local purveyor. RBC306.4 Section 708.10 Cleanout equivalent. Add new section to read: Cleanout equivalent. A fixture trap or a fixture with integral trap, readily removable without disturbing concealed piping shall be acceptable as a cleanout equivalent. REBUTAL, (disagree), proposed amendment does not meet the codes intent. If a fixture can be removed in place of a cleanout, what is the purpose for a cleanout or the code section? RBC306.4.74 Table 709.1 Drainage fixture units for fixtures and groups. Add footnote h to shower and the following footnote to the table: h. Size shower drains by the total flow rate through showerheads and body sprays as follows: Flow rate: Min. Trap Size 5.7 gpm and less 1-1/2 <5.7 to 12.3 gpm 2 <12.3 to 25.8 gpm 3 <25.8 to 55.6 gpm 4 REBUTAL, 2009 rewrite, on table 709.1, amendment not needed. RBC306.4.78 Section 802.1.7 Commercial dishwashing machines. Delete and replace with the following: The discharge from a commercial dishwashing machine shall be through an air gap or air break into a standpipe or the tailpiece of a waste receptor. REBUTAL, the description (tail piece of a waste receptor) meets the definition of an air break, amendment not necessary. RBC306.4 Section 802.3.2 Open hub waste receptors. Delete the words: water-impervious from the sentence. REBUTAL, not necessary to amend out (water-impervious), this is implied. RBC306.4 Section 903.2 Vent termination. Delete the section and replace with: Every vent stack or stack vent shall terminate outdoors to the open air. REBUTAL, not necessary to amend. This code section applies to (pressure relief) because of multiple branch intervals, a vent stack would eventually find its way to open air.

RBC306.4 Section 1002.1 Fixture traps. Add a new exception #4 to read: 3. A three compartment commercial kitchen sink may be drained with a continues waste with the Ptrap located at the far end of the row of sinks. REBUTAL, (rewrite) last few words to read (with the Ptrap located at the end compartment). RBC306.4.81 Section 1002.4 Trap seals. Delete the second sentence and replace with: Where a trap seal is subject to loss by evaporation, a trap seal primer valve, or other approved accepted automatic method to prevent sewer gas from entering the space shall be installed. Add an exception to read: Exception: R-3 and the individual dwelling units of R-2 occupancies. REBUTAL, (rewrite). Leave approved, this word references an alternate method and material that can be granted by the administrative authority. Keep the added exception. RBC306.4 Section 1003.4 Oil separators required. Delete the exception and insert: Exception: An oil separator is not required in hydraulic elevator pits where an oil minder pump is installed. REBUTAL, not necessary to amend and rewrite the exception. An oil minder pump would be better than minimum code. RBC306.4 Section 1003.6 Laundries Delete section and insert: Laundry facilities not installed within an individual dwelling unit, intended for individual family use, or a single residential type clothes washer installed in other than a dwelling unit, shall be equipped with a wire basket, screen or similar device, removable for cleaning, that prevents the passage into the drainage system of solids 0.5 inch or larger in size, string, rags, buttons, or other materials detrimental to the public or private sewage system REBUTAL, not necessary to amend and redefine. The intent is to protect the public sewer from commercial facilities, not residential type equipment. RBC306.4.85 Section 1101.2 Where required. Delete the first sentence and replace with: All roofs shall drain into a storm sewer system, or to an approved place of disposal. REBUTAL, not necessary to amend because of (combined sewer system). This system is not applicable, and the first sentence implies that a disposal method be used. RBC306.4.86 Section 1101.8 Cleanouts required. Delete the exception REBUTAL, by deleting the exception, it makes subsurface drainage systems have to comply with this section. Amendment not necessary. RBC306.4.88 Section 1102.5 Subsoil drain pipes. Delete in its entirety. REBUTAL, (disagree). This code section lends guidance for other installations external to the structure. RBC306.4.89 Section 1103 Traps. Delete in its entirety. REBUTAL, not necessary to delete. Code section applies to combined sewer system, and is not applicable. RBC306.4.90 Section 1104.2 Combining storm with sanitary drainage. Delete in its entirety REBUTAL, combined sewer systems are not utilized in our jurisdiction, the code section is not applicable. RBC306.4 Section 1106.6.1 Roof gutter locations. Add a new Section 1106.6.1 to read: Roof gutter locations. All roof gutter drainage systems shall be installed to the exterior of the building structure only, beyond the furthest edge of a sloped roof. Roof gutters shall not be installed to the inside of parapet walls or similar construction. REBUTAL, interior collection systems are not defined as roof gutter. These types of designs are necessary in metal building structures. Do not amend. RBC306.4 Section 1106.6 Size of roof gutters. Add an exception to read: Exception: One and two family dwellings shall comply with the International Residential Code. REBUTAL, not necessary to amend. Residential gutter installations exceed minimum requirements, code section is implied.

RBC306.4 Section 1107.3 Size of secondary drains. Add two sentences to the end of the subsection reading: Scuppers shall be sized per table 1107.3. Secondary drain openings shall not be more than 2 inches above the inlet level of the primary drain. REBUTAL, amendment not needed. Historically there is no evidence that suggests scupper sizing and installation requires new definition. RBC306.4.91 Section 1108 Combined sanitary and storm system. Delete in its entirety. REBUTAL, combined sewer systems are not utilized in our jurisdiction, the code section is not applicable. RBC306.4.92 Section 1111 Subsoil drains. Delete in its entirety. REBUTAL, not necessary to delete, this code section lends guidance for other applications external to the structure. RBC306.4.93 Section 1112 Building Subdrains. Delete and replace with the following: Building Storm Subdrains. REBUTAL, not necessary to amend and define (Storm) subdrains. This code section is in the storm drain section and is only applicable in this section.