Sanitary Sewer Design Standards



Similar documents
The checklist utilized by the Authority will be similar to that which is shown below. Project Name: Location: Consulting Engineering Firm:

SECTION 5 DRAFTING STANDARDS

SEWER LINE EXTENSION DESIGN CHECKLIST

SECTION 5: SANITARY SEWER SYSTEM DESIGN

CHAPTER 6 SEWER SYSTEM DESIGN STANDARDS

Chapter 9 Sanitary Sewers

SANITARY SEWER SPECIFICATIONS

ENGINEERING DESIGN GUIDELINES. for SUBDIVISIONS OR COMMERCIAL DEVELOPMENTS

CITY OF ANN ARBOR PUBLIC SERVICES PLAN REVIEW CHECKLIST

CITY OF SALEM DEPARTMENT OF PUBLIC WORKS ADMINISTRATIVE RULES CHAPTER 109 DIVISION 003 SANITARY SEWER COLLECTION SYSTEM

DIVISION 2 - SEWERAGE AND DRAINAGE SECTION STORM DRAIN SYSTEMS PART 1 - GENERAL

Let Us Give Utilities the Respect that they Deserve.

SERVICE LINE EXTENSION AND SERVICE LINE CONNECTION CONDENSED SANITARY SEWER SYSTEM INSTALLATION SPECIFICATIONS

SECTION 3 SANITARY SEWER DESIGN

PUBLIC WORKS DESIGN, SPECIFICATIONS & PROCEDURES MANUAL LINEAR INFRASTRUCTURE

DIVISION OF WATER QUALITY CONSTRUCTION GRANTS & LOANS SECTION FAST TRACK AUDIT CHECKLIST

SEPTIC SYSTEM CONSTRUCTION REQUIREMENTS ST. MARY S COUNTY HEALTH DEPARTMENT

Standards for Water, Sewer, and Sewage Lift Station Design

SECTION STORM DRAINAGE TABLE OF CONTENTS

CITY OF VAUGHAN SCHEDULE O LOT GRADING DESIGN FOR RESIDENTIAL DEVELOPMENT

SECTION 7 UNDERDRAIN SERVICE

SECTION LS 2530 SANITARY SEWERS. A. General: Submit the following in accordance with The General Conditions.

ARTICLE II (2) ARTICLE II - REQUIRED USE OF PUBLIC SEWERS. PARAGRAPH Purpose and Application.

CLEANING, INSPECTION, AND TESTING OF SEWERS

UNIVERSITY OF WASHINGTON Facilities Services Design Guide. Civil. Topographical Survey. Design Evaluation. Construction Submittals

CHAPTER 17: STORM SEWER STANDARDS Introduction Administration Standards 17.1

CITY OF FARMERSVILLE, TEXAS

SECTION 6A STORM DRAIN DESIGN Mar S E C T I O N 6A STORM DRAIN - DESIGN

CHAPTER 2 HYDRAULICS OF SEWERS

Specifications for Residential Property Owners Connection to New Public Sewer

SECTION 7- STORM SEWER

SECTION 6 SANITARY SEWER MAIN 6.01 SCOPE

Beacon Hill Sewer District Standard Specifications

Wastewater Collection System Supplemental Design Standards for Capital Improvement Program Projects

CHAPTER 5. Storm Sewer

Top 10+ Mistakes of DWV plumbing design

Wastewater Capital Projects Management Standard Construction Specification

APPLICATION PROCEDURES FOR PLACEMENT OF UNDERGROUND WATER AND SEWER PIPELINES IN THE VICINITY OF TRANSPORTATION FACILITIES UNDER THE

FIBER-OPTIC CABLE PLAN CHECK

3A General Information A. Concepts... 1 B. Conditions... 1

San Antonio Water System Standard Specifications for Construction ITEM NO. 854 SANITARY SEWER LATERALS

LS 2540 SEWER LATERALS AND INSPECTION TEES

2.0 DESIGN CRITERIA FOR WATER DISTRIBUTION SYSTEMS

Engineering Specifications February, 2004 Schedule H to Bylaw 7452, Subdivision Bylaw Page 18

Town of Elkton & Cecil Soil Conservation District Checklist for Joint Agency Review Stormwater Management / Erosion and Sediment Control

FY11 Sanitary Sewer Main Rehab and Point Repair Bid Tabulation

Close-Out Documents... 9

SECTION AS-BUILT DOCUMENTATION

SITE IMPROVEMENT PLANS CHECKLIST

Section 5 Sanitary Sewer

Minimum Design Criteria for the permitting of Gravity Sewers

City of Lubbock Public Works Engineering Design Standards and Specifications

Sanitary Sewer Overflow (SSO) Incident Report Form

FY08 SEWER POINT REPAIRS BID TABULATION

Texas Commission on Environmental Quality Page 1 Chapter Design Criteria for Domestic Wastewater Systems

Precast Manhole Sections and Castings. These items shall conform to Section 31, "Storm Drain Installation," of these Standard Provisions.

CITY OF ST. CA THARINE S. cn- Olc.4 BY-LAW NO. WHEREAS the Council of the Corporation of the City of St. Catharines, is

WESTFIELD-WASHINGTON ADVISORY PLAN COMMISSION December 7, SPP-24 & 1512-ODP-24

LAKEHAVEN UTILITY DISTRICT. Developer Extension Agreement Application

SECTION GRAVITY SANITARY SEWERS

DESCRIPTION OF WORK:

STATE OF ALASKA DEPARTMENT OF NATURAL RESOURCES DIVISION OF MINING, LAND AND WATER. GENERAL SURVEY INSTRUCTIONS EASEMENTS Authority 11 AAC 53

CITY OF TUCSON, WATER DEPARTMENT DESIGN STANDARD NO WATER PLAN DRAFTING STANDARDS TABLE OF CONTENTS

HIGHWAY DEPARTMENT ACCESS AND RIGHT OF WAY WIDTH GUIDELINES

Customer Procedures and General Information for Sewer Customers

Right-of-Way Permit Application Process (Plans that affect District owned or maintained right-of-way)

PART 6 - STANDARD DESIGN AND CALCULATION FORMS 6.1 SANITARY SEWER DATA SHEET

Exhibit A. Rules and Regulations for House Connections and Sewer Extensions

SECTION STORM DRAINAGE SYSTEM

TABLE OF CONTENTS. Manhole, Frame, and Cover Installation (includes Drop Manhole) Additional Manhole Depth

State of Illinois Department Of Transportation CONSTRUCTION INSPECTOR S CHECKLIST FOR STORM SEWERS

SECTION POINT REPAIRS TO SANITARY SEWERS. A. Repairs to existing sewer lines by replacing short lengths of failed pipe.

SECTION 55 PIPE FOR STORM DRAINS AND CULVERTS (FAA D-701)

San Antonio Water System Standard Specifications for Construction ITEM NO SLIP-LINING SANITARY SEWERS

OAR52 A-1 (September, 1981)

SECTION PRECAST CONCRETE UTILITY STRUCTURES

Town House Center Highway North Huntingdon, PA 15642

APPENDIX C INLETS. The application and types of storm drainage inlets are presented in detail in this Appendix.

DESIGN AND CONSTRUCTION GUIDELINES AND STANDARDS DIVISION 33 UTILITIES SITE UTILITIES

STANDARD SPECIFICATIONS SECTION INSTALLATION OF GRAVITY SEWER PIPELINES. 1. Trenching, Backfilling and Compacting: 02223

CHAPTER 3 STORM DRAINAGE SYSTEMS

Guidelines for Fiber Optic Cable Permits

City of Regina Standard Construction Specification SECTION 1320 SEWERMAIN TESTING

A. Contractor shall furnish, to the Engineer, all materials certifications available from the manufacturer for all required materials.

Nebraska Department of Roads Drainage and Erosion Control Manual December 2011 Appendix C: Pipe Material Policy Page C-1 PIPE MATERIAL POLICY

Septic System Design Manual

ORDINANCE NO

PART 5 : WASTEWATER DRAINAGE

Section 2100-Trenching and Tunneling

City of West Linn Public Works Design Standards Table of Contents

Sewer Rehabilitation Design Requirements

MUNICIPAL ENGINEERING RESIDENTIAL SUBDIVISON STANDARDS

SECTION ABANDONMENT OF SEWER MAINS

SECTION STORM DRAIN SYSTEM

CAMROSA WATER DISTRICT

SIERRA LAKES COUNTY WATER DISTRICT P.O. Box 1039, Soda Springs, CA (7300 Short Road, Serene Lakes)

TOPOGRAPHICAL SURVEY REPORT - PART OF L.R No. 7413/11 Done on February 2015 at International Union for Conservation of Nature (IUCN) Eastern African

Transcription:

Sanitary Sewer Design Standards Rogue Valley Sewer Services Revised 8/29/2012

Contents 1. Plan Review Procedures and Submittal Requirements 3 1.1 Pre-Design Meeting: 3 1.2 Initial Design Submittal: 3 1.3 Final Design Submittal: 3 1.4 Completed Project Submittal: 3 2. Drafting Requirements: 5 2.1 Cover Sheet: 5 2.2 Profile: 5 2.3 Plan View: 6 3. General Design Requirements: 7 3.1 Design Flow Rate 7 3.2 Mainline Pipe Size and Slope: 7 3.3 Main Line Alignment: 8 3.3.1 Horizontal Separation 8 3.3.2 Vertical Separation 8 3.3.3 Curved Sewer Mains: 9 3.3.4 Easements: 9 4. Manholes: 10 4.1 Manhole Spacing: 10 4.2 Manhole Diameter: 10 4.3 Engulfment Protection: 10 4.4 Drop Manholes: 10 4.5 Flat Top Manholes: 10 4.6 Manhole Cone Section: 10 4.7 Manhole Necks: 10 4.8 Cleanouts: 10 4.9 Access: 11 4.10 Hydrogen Sulfide Protection: 11 4.11 Lockdown Manhole Covers: 11 1 Page of 14

4.12 Connection to Existing Manholes: 11 4.13 Watertight Manhole Covers: 11 4.14 Monitoring Manholes: 11 5. Service Laterals: 12 5.1 Pipe Size and Slope: 12 5.2 Connection to Existing Mains: 12 5.3 Alignment: 12 5.4 Service Cleanouts: 13 5.5 Multiple Services: 13 6. Pressure Sewer Systems: 13 2 Page of 14

1. Plan Review Procedures and Submittal Requirements 1.1 Pre-Design Meeting: A pre-design meeting is not required, although it is strongly recommended. During the pre-design meeting the design engineer and RVSS staff will review the proposed development and identify the best location for connection to the existing sewer system, necessary easements, and the extent of off-site improvements. RVSS staff will also provide an estimate of the fees associated with the proposed development. 1.2 Initial Design Submittal: The initial submittal shall contain all drawings and calculations as described in Sections 2 and 3 of these design standards. RVSS District Engineer will review the plans and calculations for compliance with the design standards. RVSS District Engineer will issue a plan review letter to the Design Engineer detailing any deficiencies or required changes in the plans. Along with the plan review letter, RVSS District Engineer will also submit a Sewer Service Agreement letter which will describe the terms and conditions of the sewer project and itemize all associated fees. 1.3 Final Design Submittal: After all of the required plan changes have been made, the design engineer shall submit a final set of drawings printed on mylar, along with the preliminary plans previously reviewed. The final design submittal shall also include the Sewer Service Agreement signed by both the developer and the Engineer, executed easements, and all associated fees. RVSS District Engineer will review the final submittal to ensure that all of the required changes have been made. When all of the final design requirements have been met, the RVSS District Engineer will indicate plan approval by signing the drawings in the appropriate location. The approved drawings will be returned to the Design Engineer with a plan approval letter formally approving the project design. The Design Engineer will return to RVSS two sets of the approved plans printed on bond paper. 1.4 Completed Project Submittal: Upon satisfactory completion of the project the Design Engineer shall submit a detailed as-built drawing on mylar. At the discretion of the Design Engineer, an electronic copy of the as-built drawing can be provided to RVSS as a substitute for the mylar copy. The electronic format shall be compatible with AutoCAD Version 2004. The as-built drawing shall be drawn in NAD 83 State Plane Coordinates using International Survey Feet and all vertical elevations referenced to NAVD 88. 3 Page of 14

The Design Engineer shall also provide RVSS with all of the costs associated with the sewer construction project. Upon satisfactory receipt of the required completed project information, the RVSS District Engineer will issue a project acceptance letter formally accepting the project and beginning the two year construction warranty. No permits to connect to the system will be issued until this is complete. Please note: The ultimate responsibility for a properly constructed system remains with the property owner and the owner s Engineer until the project is formally accepted by RVSS. Preliminary inspections and approvals by RVSS do not relieve the Owner or Engineer from this responsibility. 4 Page of 14

2. Drafting Requirements: Sewer construction plans shall be printed on 24"x36" sheets. All drawings shall be dimensioned in British units. Metric units may be used in parentheses. Drawings shall contain the following information: 2.1 Cover Sheet: A cover sheet shall be provided for sewer plans consisting of three or more pages or where project plans include water, street, or other improvements. The following information shall be provided on the cover sheet, or on the first page of the drawings where no cover sheet is used: a. Date b. Vicinity map showing location of project and overall sewer system. c. Schedule of quantities listed by size and pipe material. d. North arrow e. Project benchmark and basis of bearing. Benchmark elevation shall be referenced to the nearest existing manhole invert. f. General notes to include the following: i. Construction shall be performed in accordance with RVSS Standard Specifications and Standard Drawings, as last revised. ii. Contractor shall notify RVSS 48 hours in advance of construction. iii. All taps to the existing sewer main shall be done by a contractor pre-approved by RVSS. g. Design Engineer s name, address, and signed stamp clearly showing the expiration date. Engineer shall be a registered professional engineer in the State of Oregon. h. Owner/developer s name and address. i. RVSS plan approval block (This must be included on all sheets with sewer data). 2.2 Profile: Profile views shall be provided for all sewer main line. Profile views shall be on the same sheet as the associated plan view and shall include the following information: a. Class of backfill b. Size, slope, length, and class of pipe. c. Manhole rim and invert elevations. d. Horizontal and vertical scale. [maximum horizontal scale 1:600, (1" = 50'); vertical exaggeration as appropriate to show detail] e. Utility crossings with vertical distance between proposed sewer and existing or proposed utility shown. f. Existing ground profile. g. Match line when profile covers more than one page. h. Profile stationing to coincide with plan stationing. 5 Page of 14

2.3 Plan View: Plan views shall be provided for all sewer main line. Plan views shall be on the same sheet as the associated profile view and shall include the following information: a. Drawing scale, maximum scale 1:600, (1" = 50'). b. Township, Range, Section and Tax Lot numbers for areas to be served and adjacent properties. For subdivisions or partitions, the tax lot number of the parcel to be divided should be shown. a. Existing utilities, wells, and structures. c. Street names, right-of-way lines, and right-of-way centerlines. b. Property lines and easements. c. Distance from sewer centerline to centerline of right-of-way. Manholes shall be referenced to the centerline of the right-of-way and the road station. d. Sewer stationing shall begin at the lowest downstream manhole. Sewer mains within the right-of-way may use road stationing with offsets. Outside the right-of-way sewer stationing should be independent of the road stationing. d. Manholes shall be numbered in consecutive order, starting from the downstream manhole, and shall be referenced by sewer stationing that coincides with the profile stationing. e. New manholes over existing mains shall be dimensioned to the closest downstream manhole. f. Location of all service laterals, referenced by sewer station. g. City limits, urban growth boundary if applicable. e. Legend [utilities and other lines shall be differentiated by using varying line types and thicknesses]. h. Proposed finished floor elevations. i. Test hole locations, if applicable. 6 Page of 14

3. General Design Requirements: Design calculations are required where a simple 8" diameter gravity sewer is inadequate to serve the current or future project area. Situations that would require calculations are pipe size increases to accommodate larger current or future populations, siphons, or any other irregularity in the design of the sewer. Complete calculations may also be required for any structural designs. If computer assisted design software is used to provide the design calculations, the software designer shall be identified including the version and serial number used, a sample calculation shall be provided with the printout. 3.1 Design Flow Rate: The design of sewer system facilities shall be based on a design flow rate of 350 gallons per day per residential unit. Commercial uses shall be converted to equivalent residential units using the conversion rates adopted by the Regional Wastewater Committee. Industrial flow rates shall be based on the design flows for the particular industry. Peaking factor shall be calculated using the following formula: PF = 1.25 + [14 (4 + (P))] where PF is the peaking factor and P is the contributing population in 1,000's. Alternate methods of calculating flow rates and peaking factors may be used, provided that the design engineer submits sufficient data to justify the alternate methods. 3.2 Mainline Pipe Size and Slope: Pipe size shall be determined using full pipe flow at peak flow conditions. The Manning s friction factor used for all pipe shall be 0.013. The minimum pipe size, regardless of flow rate, shall be 8 inch diameter. All sewers to be constructed at slopes that will produce a minimum velocity of at least 2 feet per second when flowing full or half full Minimum pipe slopes for various sized pipe shall be as follows: Pipe Size Minimum Slope (m/m) 8"...0.0040 10"...0.0028 12"...0.0022 15"...0.0016 18"...0.0012 21"...0.0010 24"...0.0008 7 Page of 14

The minimum slope should only be used when topography and existing sewer depth make greater slopes impossible or when anticipated flows are such that scouring velocity is achieved on a regular basis. Increases in pipe size to allow lower slope will not be permitted. No maximum slope is specified, however, where flow velocity at half pipe flow is greater than 12 feet per second, special design of manholes are required to prevent scour of the channel or splashing. Velocities of greater than 20 feet per second or more are not allowed. 3.3 Main Line Alignment: Sewer mains shall generally be constructed in straight lines from manhole to manhole within the public right-of-way. 3.3.1 Horizontal Separation To remain consistent with Oregon State Health Department regulations OAR 52, a 10 foot (3.1m) minimum horizontal separation between water and sewer lines is required. Horizontal separation may be reduced to 5 feet (1.55m) provided that there is a minimum of 1.5 feet(0.5m) vertical separation between the water and sewer pipes, with the sewer pipe being deeper. Where minimum separation cannot be achieved, pressure rated pipe material will be required. In subdivisions with full width street improvements the sewer main shall be located 7 feet (2.13m) from and parallel to the street centerline on the opposite side of the centerline from the waterline. In areas where a street section is not being constructed in conjunction with the sewer main, the sewer main shall be constructed parallel to street centerline and on the property side of the drainage ditch or as directed by RVSS. 50 feet (15.25m) of horizontal separation between water wells and sewer line is required. If the minimum separation cannot be achieved, the sewer line must be constructed from a pressure rated pipe material from upstream manhole to downstream manhole. 3.3.2 Vertical Separation - Mains shall be constructed with a minimum cover of 3 feet. (0.92m). Sewer mains shall generally be located below water mains. Sewer mains parallel to or crossing water mains do not require special construction under the following conditions: 1. Parallel water and sewer mains with 10 feet (3.1m) or more horizontal separation. 1. Parallel water and sewer mains with 5 feet (1.55m) of horizontal separation and 1.5 feet (0.5m) of vertical separation, (sewer below water). 8 Page of 14

2. Perpendicular water and sewer mains with the sewer 1.5 feet (0.5m) or more below the water main. All other zones of construction will require the installation of pressure rated pipe in accordance with the Oregon State Health Department regulations. 3.3.3 Curved Sewer Mains: Curved sewer mains may be used when the RVSS District Engineer determines certain conditions require the use of minimum radii pipe installation with manholes at each end. The following table specifies the minimum curve radius permitted. PVC pipe size Minimum curve radius 8".....420 ft. 10"... 525 ft. 12"... 630 ft. 15"... 735 ft. 3.3.4 Easements: Where sewer mains cannot be located within a public right-of-way, they shall be located within an exclusive easement granted to RVSS. Sewer easements shall have a width equal to twice the depth of the sewer main, or 15 feet (4.6m), whichever is greater. Sewer easements shall be written and recorded on standardize easement forms obtained from RVSS. Sewer mains shall not be installed within a Public Utility Easement. All easements shall also allow for year round vehicular access to all manholes and cleanouts. 9 Page of 14

4. Manholes: Manholes shall be located at all sewer main intersections, at all changes in vertical or horizontal alignment, and at the beginning and end of curved sewer sections. 4.1 Manhole Spacing: Maximum manhole spacing shall be 500 feet (152m). Manholes shall be installed at all terminating sewer mains longer than 180 feet (55m). 4.2 Manhole Diameter: Manholes 48 inches in diameter may be used for sewer mains up to 18 inches diameter and up to 15 feet (4.6m) deep. Manholes 60 inches in diameter may be used for sewer mains from 18 inches to 42 inches in diameter and up to 22 feet (6.1m) deep or where pipe spacing would be less than 1.5 feet apart with a 48 inch diameter manhole. 4.3 Engulfment Protection: Manholes on sewer lines 21 inches and larger shall be designed with engulfment protection of corrosion proof materials resting in two pieces on the manhole shelf and sufficiently restrained and supported to the manufacturers design requirements for concentrated loads of 200 lbs (91kg). 4.4 Drop Manholes: Drop through manholes shall be a minimum of 0.1 feet (3.1 cm) for straight runs or 0.2 feet (6.1cm) for all others. Inside drops shall have a maximum drop of 2 feet (61cm). Drops greater than 2 feet (61cm) shall be constructed with outside drop structures. 4.5 Flat Top Manholes: Flat top manholes shall be used where the distance from the invert to the rim is less than 3 feet (1.2m). 4.6 Manhole Cone Section: Manholes greater than 3 feet (1.2m) and less than 5 feet (1.8m) deep shall be constructed with a concentric cone section. Manholes greater than 5 feet (1.8m) deep shall be constructed with an eccentric cone section. 4.7 Manhole Necks: Manhole necks shall be adjusted to finished grade by the use of concrete grade rings with approved sealant between each ring. The maximum height of grade rings shall be 12 inches (0.3m) for new construction and 18 inches (0.5m) for modifications to existing manholes. Adjustments beyond these limits shall be made with full barrel sections. 4.8 Cleanouts: End of line cleanouts may be used when the terminal reach of sewer main is less than 180 feet (55m) long. In line cleanouts shall be provided for wastewater relief whenever the proposed finished floor of a structure is lower than the next upstream manhole. 10 Page of 14

4.9 Access: All manholes and cleanouts shall be located in such a way that maintenance vehicles will have year round access. 4.10 Hydrogen Sulfide Protection: Downstream transition manholes originating from a pump station or manholes where turbulence is a factor may be required by RVSS to be coated with hydrogen sulfide resistant material. 4.11 Lockdown Manhole Covers: Manholes located outside of the paved surface shall be fitted with lockdown, watertight covers. 4.12 Connection to Existing Manholes: Connection to existing manholes shall be made with a concrete core saw and sanded collar fitting or cast in place bell with gasketed seal. There are no exceptions to this requirement. New connections to existing manholes shall be fitted with a temporary plug until the entire project has been accepted. Connections to structures other than manholes shall be specifically detailed on the plans for approval by RVSS. 4.13 Watertight Manhole Covers: Where a manhole is in a sump or other area that is prone to flooding, or located within the 25 year flood plain, watertight covers shall be used. Manhole cones shall be rotated to avoid areas of standing water to the extent possible. 4.14 Monitoring Manholes: Monitoring manholes may be required at commercial/industrial service connections at the direction of RVSS. 11 Page of 14

5. Service Laterals: Service laterals shall be provided to every parcel being served as part of the project. Each individual building or dwelling on the same parcel shall have a separate service lateral if property can be further divided under current zoning classifications 5.1 Pipe Size and Slope: Service line laterals shall be a minimum of 4 inch in diameter and installed at a minimum slope of 1/4 inch per foot for 4 inch services and a slope of 1/8 inch per foot for 6 inch services within the public right of way or a dedicated sewer easement. All Service line laterals installed on private property shall be installed in accordance with the latest revision of the Oregon State Plumbing Specialty Code. 5.2 Connection to Existing Mains: Service line connections to existing mains may be made by tapping the existing main only when the service line is 0.75 times the main line size, or less. If this ratio is exceeded, the connection shall be made by removing a section of the main line and installing a properly sized wye fitting. Service lines larger than 8 inches will require a mainline manhole. 4 inch diameter service laterals shall not be connected directly to a manhole. Taps are to be located at a minimum spacing of 18 inches apart. No service line connections shall be made into a 30 inch diameter or larger interceptor unless approved by the RVSS District Engineer. Connection to 30 inch diameter or larger interceptor shall be made by first tapping the interceptor with an 8 inch pipe, extending the 8 inch pipe a minimum of 10 feet from the interceptor at ninety degree angle, installing a manhole, and then installing 20 feet of 8 inch pipe upstream of the new manhole and parallel to the interceptor. Service line connections can then be made into the new 20 foot segment of 8 inch pipe. 5.3 Alignment: Service laterals shall be constructed perpendicular to the main line and shall intersect the property line a minimum of 1.55m (5') from the property corners. Exceptions will be made in the case of cul-de-sacs where perpendicular service lines are not practical. 12 Page of 14

5.4 Service Cleanouts: Service line laterals shall have cleanout installed in accordance with the latest revision of the Oregon State Plumbing Specialty Code. 5.5 Multiple Services: Multiple service laterals may be installed in a common trench provided that a minimum 0.31M (1 foot) clearance is provided between each pipe. 6. Pressure Sewer Systems: Pressurized sewer systems will be allowed only when topographic conditions preclude the use of traditional gravity systems. Pressure systems must meet all of the design review requirements outlined in RVSS Design Criteria for Septic Tank Effluent or Pressure Sewer Construction Plans as last revised. 13 Page of 14