aquatherm black Ecological and economical the modern way to heat

Similar documents
Rainwater Harvesting

Pioneer Floor Heating: Hydronic Underfloor Heating

We have been working in an ideal climate for thirty years.

Module 2.2. Heat transfer mechanisms

Solar Homes Catch the Sun. Are you planning a new house? Discover how you can apply solar architecture principles to:

SIM Spartherm Installation Modules NEW

ROTEX gas hybrid heat pump. A strong team.

Industrial infrared heater IR For premises with large volumes and high ceilings

CONDENSATION IN REFRIDGERATED BUILDINGS

Introduction. 1. Heat Transfer. In Townsville s climate it is essential to choose building materials that perform well in our local conditions.

Advice to consumer Reference 50.1 May Condensation. Some causes, some advice.

The Warm Edge for insulating glass

CONDENSATION - THE BASICS

Integrated Solar Radiant Systems

BUILDING ASSESSMENT QUESTIONNAIRE. B. TENANTS Is there more than one tenant in the building? YES

RESSÒ: energy efficiency urban rehabilitation

We care about. Environmentally-Friendly Building Products from Renewable Resources. natural building products. Product range overview

Owner s Manual

Energy efficient windows, doors and conservatories. Make a better choice

Humidity, Condensation, Clouds, and Fog. Water in the Atmosphere

CERTIFICATE NAME OF PRODUCT MANUFACTURER PRODUCT DESCRIPTION CERTIFICATION PROCEDURE. No VTT C Date of issue , Updated July 1, 2011

Opening the Bonnet. Prof Darren Woolf WYSINWYG 1

FACTORS AFFECTING ENERGY CONSUMPTION OF BUILDINGS

Mapei systems for radiating floor heating with high thermal efficiency

COMPARISON OF THE THERMAL ENVIRONMENT IN ROOMS WITH CHILLED BEAM AND RADIANT PANEL SYSTEMS

AND MEMBRANES ROOFING UNDERLAYS.

Radiant Heating and Cooling Systems BY KWANG WOO KIM, ARCH.D., MEMBER ASHRAE; BJARNE W. OLESEN, PH.D., FELLOW ASHRAE

Rockwool Flexi Insulation Application Guide

Radiant Panels and Chilled Sails.

Solar air collectors for industry and larger halls S Ø. Efficient dehumidification and air heating for free...

DISTRIBUTED GENERATION AND ENERGY EFFICIENCY FOR ACHIEVING ENERGY SELF-SUSTAINING INDUSTRIAL AREAS

Conservatory warm roof conversion system

NEW CEILING MODULE DS-W1 WAVE : SUBSTANTIALLY HIGHER CAPACITY AND ENERGY EFFICIENCY

Molds and mildew are fungi that grow

2 STEPS TO CONDUCTING YOUR HVAC ASSESSMENT

Energy Company Obligation (ECO): Technical Monitoring Questions

The Concept. How Cassettair can benefit you. Applications. Selecting Cassettair

HDA

Cast Iron Radiator Heating Capacity Guide

Housing Services Guidance for tackling condensation, damp and mould in your home

VITOSOL r 200-T SP2A. VITOSOL 200-T Type SP2A

What a good idea! Turn your conservatory into an all-year-round living space.

AIR CONDITIONERS ROOF TOP & UNDERBUNK INSPIRED BY COMFORT NEW RELEASE DOMETIC FRESHJET

Post-insulation of cellar ceiling and cellar walls

19 Examples of Wall Insulation

Vicot Solar Air Conditioning. V i c o t A i r C o n d i t i o n i n g C o., l t d Tel: Fax:

Report Date: 04/03/2014. Assessor: John Doyle Address: BLOCK K APT 108 SANDYFORD VIEW DUBLIN 18 BER: MPRN:

Managing Heat Stress in Poultry

Dealing with damp and mould growth

Thermal environments. Tel

Acoustic Design Practices for Sustainable Buildings

CHAPTER CONTENT PAGE. Hybrid: The perfect solution for all systems. Explanation of the - Heat Exchanger 4. Finishes 12

Natural geothermal energy.

Advisers for real building

Pellet Fires Tasmania 108 Gormanston Rd Moonah TAS

5 Things. You Must Know. Before Buying. Radiant Barrier

Dealing with damp, condensation and mould growth in your home.

1..GENERAL DATA 2. CLIMATIC DATA. Location

Energy efficient home design

Key energy-efficient features of your new home

Facility Operations Physical Safety Guidance Document

Life cycle cost comparison of TAB vs. other HVAC (UK) TECHNICAL BROCHURE

Creating the Ideal Environment for Accelerated Drying Times on Construction and Restoration Projects

1/9/2013. Terminology Calculating Heat Transfer Code Requirements Design Examples and Sustainability

Planning Information. Passenger and Freight Elevators.

Solar Thermal Systems

WALLS Three common wall types are described below, with their insulation solutions.

AIR CONDITIONING EFFICIENCY F8 Energy eco-efficiency opportunities in Queensland Foundries

BER Assessors Dwellings Technical Bulletin

High-efficient gas boiler CompactGas

Condensation. Some Causes, Some Advice

Choosing better, more energy efficient windows. A homeowners guide

Daikin Altherma Hybrid Heat Pump

Making heating systems efficient and cost-effective: boilers, heating controls & more

Energy Efficiency HOSPITALITY.

Building Energy Systems. - HVAC: Heating, Distribution -

Condensing Boiler Efficiency

UV Disinfection Systems A Series. Main Applications: Drinking Water, Process Water, Warm Water / Legionellae. IT T Industries Engineered for life

Tsawwassen BC Arena Before & After installation of the Low-E ceiling

Under sill units. Type FSL-B-ZAS

HOW AN ENERGY EFFICIENT HOME CAN HELP THE ENVIRONMENT

Federation of European Heating, Ventilation and Air-conditioning Associations

A few good reasons to have a conservatory. The conservatory structure

IEA SHC Task 47 Renovation of Non-Residential Buildings towards Sustainable Standards

COOLING AND HEATING OF BUILDINGS BY ACTIVATING THEIR THERMAL MASS WITH EMBEDDED HYDRONIC PIPE SYSTEMS -

HS-Steel-Classic. Curing chambers for the concrete block industry in a proven steel version

BBS/13. Redcliffs 1: Build Back Smarter Case Study

CoolTop. A unique water cooled air-conditioning unit for server room cooling from the top AC-TOPx-CW-240/60

KONRAD. Hybrid Fancoil Series

*Trademark of The Dow Chemical Company A business unit of The Dow Chemical Company and its subsidiaries Copyright 2003 The Dow Chemical Company.

Hamilton-Wentworth Catholic District School Board Event Listing By Ascending Event Year

Name: Class: Date: 10. Some substances, when exposed to visible light, absorb more energy as heat than other substances absorb.

A Code Review for Emergency Generators and Indoor Use of Portable Generators

Energy - Heat, Light, and Sound

50 St Mary Axe London EC3

Can old buildings be just as energy-efficient as new ones?

NAIOP OF SOUTHERN NEVADA SUSTAINABILE DEVELOPMENT COMMITTEE - EDUCATION SERIES

LG Electronics AE Company, Commercial Air Conditioning

SOLAR ENERGY FUNDAMENTALS

Vapor Chambers. Figure 1: Example of vapor chamber. Benefits of Using Vapor Chambers

Transcription:

aquatherm black Ecological and economical the modern way to heat 1

2

aquatherm black Ecological and economical the modern way to heat High heating costs, raisings of dust, allergies, unfavorable distribution of temperature, high flow temperatures, required space for radiators all this can be resolved by the aquatherm black system! The system is in a compact grid construction for heating, cooling as well as heating and cooling of rooms across ceiling, wall and floor areas. At a large extent, an individual s satisfaction and productivity depends on the basic environmental conditions of the surroundings. Working efficiency and comfort is considerably determined by the personal sense of well-being, which as a matter of priority is influenced by the ambient temperature. The ingenious aquatherm black system delivers pleasant room conditions without any draught. Depending on the water temperature chosen, heating or cooling is simply controlled with this technology. Automatic designed change-over of heated or chilled water completes the system, from the single room control to the perfect control engineering. Advantages: Energy saving in operation Noiseless No additional dust exposure No draught, thus highest climatic comfort Constant distribution of temperature Suitable for later installation Fast assembly To a large extent architectural freedom of designing Low construction height 3

aquatherm black system Ceiling heating Ready for use - in all four walls The system offers pipe grids in different lengths and widths so that the installation in suspended ceilings or concealed can be adjusted to the individual locations. The combination of various sizes of pipe grids is of course possible and ensures best heating and cooling results in old and new buildings. aquatherm black system Wall heating Basic idea of the wall heating is the occupant s well-being: A thermally balanced room is to be created. Therefore, the principle of technology is not air heating and circulation, but the output of heat radiation from tempered walls directly to the room and the person respectively. A comfortable warmth, since the temperature of heating surfaces can be low chosen because of the relatively large heating surfaces. This is an advantage compared to small hot surfaces, such as radiators. aquatherm black system Underfloor heating aquatherm black system, a plus for comfort. Used as underfloor heating system, the aquatherm black system allows walking barefoot in the house even in winter. Another advantage is the architectural freedom of designing the rooms. In addition to this, there are the hygienic aspects of an underfloor heating system. There are no raisings of dust. By the constant surface heat, the growth of house dust mites and formation of mould will be prevented. 4

5

24 C Old Heating Technology Convection heat 26 C 1 22 C 2 22 C 30 C 3 20 C 5 65 C 18 C 4 18 C Flow temperature 65 C Room temperature 22 C The convection heating with the old radiator 1 Energy loss 1: A high air temperature of at least 22 C is required to heat a room with air. Air is a bad heat carrier; therefore the energy costs are high. 2 3 4 5 Energy loss 2: Air heats the window. But the highest energy loss results from weak point of the insulation in the house - the window. Very high-quality windows are necessary. When airing the most energy-rich air escapes through the window. Health at risk: The air movement (warm air rises) kills the sense of well-being, too, since asthmatic and allergic persons have a primary problem with raising dust. This dust mixes with our breathing air and can lead to enormous burdens of the organism. An increase of the room temperature requires a reduction of the air humidity. Mucous membranes will dry out. The natural filtration system (nose) will be affected. Discomfort: Feet remain cold, as warm air rises up and is mainly in the upper area of a room. By that a feeling of discomfort is developed. The heating is adjusted to a higher level. The above effects will be increased. Formation of mould: Cold air strokes the wall, water condenses and creates the culture medium for the formation of mould. 6

New Heating Technology Radiant heat 20 C 20 C 2 1 3 Primary radiation 20 C 20 C 5 20 C 4 20 C Secondary radiation Flow temperature 35 C Comfort temperature 20 C The radiant heating with the new aquatherm black system 1 Energy saving 1: Comparable to the sun, the radiant heating first of all heats the solid and liquid materials in a room. Walls, ceilings and floors are constantly heated and the room temperature only in the second step. However, a high air temperature is not required for radiant heatings. An air temperature of 20 C is completely sufficient and provides a comfortable sense of well-being. 2 3 4 5 Energy saving 2: There are no losses through the window. Heat radiation is reflected by glass and given back to the room. Energy saving 3: The room temperature is low. Thus you will not have any big energy losses, even when airing. The low air temperature creates a natural and pleasant climate. Comfort: In case of radiant heat, there are no differences in temperature of the room air, like with convection heatings. The head remains cool and the feet warm. Dry walls: Since the walls are directly heated, there is no condensation and consequently no formation of mould. Rule of thumb: Reduction of room temperature by 1 C = 6 % energy saving Surface to be occupied = 60-100 % of the building area, depending on the building structure 7

aquatherm black system Heating element for dry construction Field of application: Lightweight partition walls in aluminium frames Heating capacity: 60W/m² at room temperature of 20 C Flow temperature 35 C Return temperature 31 C Delta T 13 K Type of wall: Dry-lined walls Covering: Fermacell board 12.5mm (can be painted, tiled or papered at once) Field of application: Renovation and new construction Possible dimensions for inner frame distance of 625mm: Width: 625mm length: 2,000mm # 5662200 Width: 625mm length: 1,000mm # 5662100 Pipe connection: aquatherm black system plug-in system / to be welded-fused 8

aquatherm black system Heating element for dry construction Field of application: Roof slope with dry construction Heating capacity: 60 W/m² at room temperature of 20 C Flow temperature 35 C Return temperature 31 C Delta T 13K Type of wall: Roof slopes Type of ceiling: Drywall ceiling Covering: Drywall 12.5mm, to be provided by the client Field of application: Renovation Possible dimensions for inner principal rafter of 360mm: Width: 360mm Length: 2,000/2,500 and 3,000mm Pipe connection: aquatherm black system plug-in system / to be welded-fused with 90 elbows 9

aquatherm black system heating element for plaster work (Walls and ceilings) Field of application: heating element for the installation for plastered walls Heating capacity: 76 W/m² at room temperature of 20 C Flow temperature 35 C Return temperature 31 C Delta T 13 K Type of wall: Wall with plaster work Type of plaster work: gypsum clay or lime cement plaster 10mm covering Field of application: renovation and new construction Example dimension: width: 600mm length: 2,000mm Pipe connection: to be welded-fused 10

aquatherm black system Heating element for suspended paneled ceilings Field of application: Heating element for thermal activation of paneled ceilings Heating capacity in drywall panels: Cooling capacity in drywall panels: Heating capacity in metal panels: Cooling capacity in metal panels : 78 W/m² at dt = 13 K (T medium T room) (drywall-climafit) 67 W/m² at dt = 9 K (T medium T room) (drywall-climafit) 79 W/m² at dt = 13 K (T medium T room) 78 W/m² at dt = 10 K (T medium T room) Type of ceiling: Covering: for suspended paneled ceilings panels made of metal or drywall to be provided by the client and as requested by the architect/building owner Field of application: New construction and renovation Dimensions: Width: individually according to specifications 11

1 2 12

aquatherm black system Use in Shower Comfortable warmth in the shower area No cold emitting tiles Simple assembly Independently adjustable to size of shower and shower fitting Applicable in combination with existing radiator system via single room control Suitable for connection to all standard underfloor heating systems Residual heat demand can be covered by it Installation possible in new and old buildings aquatherm black system Use in Mirror Non-fogging mirror Thanks to the use of aquatherm black system grids behind the mirror, the warmed mirror cannot be fogged up Simple assembly Independently adjustable to any size of mirror Applicable in combination with existing radiator system through single room control Sutiable for connection to all standard underfloor heating systems Perfect addition to the wall heating in showers Example of installation Shower 1 m x 1 m with concealed fitting 1 2 Article number: 5060160 (width 0.60 m / length 1.60 m) Quantity: 1 Use in the wall without fitting Article number: 5036160 (width 0.36 m / length 1.60 m) Quantity: 2 Concealed fitting is placed between pipe grids, plus connection pipes and if necessary single room control 13

1 2 3 4 aquatherm black system compatible with any heating system By the possibilities of combination with various types of heating, such as 1 2 3 4 Oil heating Pellet heating Gas heating Heat pump aquatherm black system offers the best solution for the renovation of old buildings or the designing of new buildings what ever heating system you decide for, the highest compatibility will be given and compromises in designing your new heating system will be avoided. 14

aquatherm black system becomes the design air-conditioning system h2c Perfect room climate looks as good as this. Together with aquatherm, HJE Systembau Eickhoff GmbH & Co. KG developed the individually designable air-conditioning system h2c Aluframe. H2C hot to cool stands for an intelligent surface heating and cooling system. h2c is an air-conditioning and heating system rolled into one. Developed on the basis of the aquatherm black system, the design air-conditioning system is integrated in a textile stretcher and can subsequently be provided on walls or under ceilings. Besides, h2c is also available as detached stand element, for example as partition. The system is connected to the normal heating supply. On the occasion of the EuroShop fair, the h2c ALUFRAME has already been honored with the innovation award for architecture and presentation in the category of products of high architectural quality. For further information on this system, please visit www.hje-gruppe.de 15

INFORMATION MATERIAL aquatherm green & aquatherm blue pipe systems for potable water, hydronic and industrial applications Order No. E10101 aquatherm red sprinkler pipe system Order No. E40000 aquatherm lilac pipe pipe system for recycled water Order No. E18201 aquatherm orange surface heating systems Order No. E90001 aquatherm black surface heating and cooling system for ceiling & wall Order No. E97060 aquatherm grey potable water and radiator connection system Order No. E70001 aquatherm - product catalogue aquatherm - references aquatherm ti - for underground pipe systems Order No. E54152 Order No. E57002 Order No. E30000 For detailed information, please get in touch with our info service calling 00492722 950-0 or visit the download area of our website www.aquatherm.de Stamp of dealer Management System ISO 9001:2008 ISO 14001:2004 ISO 50001:2011 www.tuv.com ID 0091005348 aquatherm GmbH Biggen 5 D-57439 Attendorn Phone: +49 (0) 2722 950-0 Fax: +49 (0) 2722 950-100 Wilhelm-Rönsch-Str. 4 D-01454 Radeberg Phone: +49 (0) 3528 4362-0 Fax: +49 (0) 3528 4362-30 info@aquatherm.de www.aquatherm.de Order No.: E 20100 Edition: 04/2013 16