PH-2. ph Meter. Operator s Manual 4.24. ph 4.24. Newport Electronics, Inc.

Similar documents
DO-6. Dissolved Oxygen Meter. Newport Electronics, Inc. Operator s Manual

OME-SERIES DATA ACQUISITION CARDS

MFT Series INTRODUCTION UNPACKING FERRULES

User s Guide. y = mx+b. Shop online at. A Guide to Calibration and Unit Conversion

User s Guide OSXL-100-PE. Thermal Imaging Camera Enclosure. Shop online at omega.com SM


User s Guide DPF700-A. Analog Output Option Board for the DPF700 Meter. Shop on line at. info@omega.com

User s Guide HHAQ IN-1 Psychrometer With Enthalpy. Shop online at omega.com SM

ExStik TM ph Waterproof Meters

Shop online at: omega.com For latest product manuals: omegamanual.info

User Guide. ExStik TM ph (PH100 & PH110) and ORP (RE300) Waterproof Series Pens. Patent Pending

User s Guide. SOFTWARE FOR OMB-DAQ-2416 SERIES And OM-USB SERIES. Universal Library. Redistribution Guide. Shop online at

User s Guide EWS-RH. Relative Humidity/Temperature Transmitter. Shop online at omega.com

User s Guide HFS-3, HFS-4. Shop online at. Thin Film Flux Sensors. omega.com info@omega.com For latest product manuals: omegamanual.

Care and use guide. Contents. a handy solution made easy. page

User s Guide TL-WELD. Thermocouple and Fine Wire Welder. Shop online at omega.com SM

User's Manual. Heavy Duty Dissolved Oxygen Meter Model

User s Guide. SW DIN Series and OSW Series. Shop online at. Rotary Selector Switches

AIRMoN, ph and Conductivity Field Measurement

Instruction Manual Temp 4/5/6 Temperature Meter Series

OPERATION MANUAL. Pen type, separate electrode SOIL PH METER Model : PH-220S

User s Guide HHF81. Anemometer, Hygrometer, Light Meter, Thermometer. Shop online at omega.com

Bluelab Soil ph Meter Instruction Manual

ph Measurement and Control

Milwaukee USER MANUAL

Global Water Instrumentation, Inc.

Measuring ph in Water or CaCl2 Using a ph Meter. Compiled by Darren Murray, June 30, 2011 TABLE OF CONTENTS OVERVIEW 3

User s Guide MTC SERIES. Shop online at. Multi-Pin Thermocouple Connectors

Care and use guide. Contents. page

Model RPM10 Laser Photo / Contact Tachometer with IR Thermometer Patented

Duct Temperature Sensors

2-3 SAS/SATA II HDD Canister USER S MANUAL XC-23D1-SA10-0-R. Document number: MAN A

Pipe Temperature Sensors

UltraBasic Benchtop ph Meter Operation Manual

LCD5500Z / PKP-LCD v3.x Installation Instructions

Care and use guide. Contents. a handy solution made easy. page

Instruction Manual HI Refractometer for Refractive Index and Brix Measurements

Milwaukee USER MANUAL. Milwaukee. Smart DO Meter PORTABLE DISSOLVED OXYGEN METER MODEL: SM600. Authorized Dealer: ISMIL600 11/01

3 WATT LED SPOTLIGHT Model No. SLM

SenTix 950 SenTix 980

Part I - Installation

DICKSON PW4 DICKSON. Pressure Chart Recorders. Applications & Specifications. Product. Getting Started, Charts & Accessories.

User Guide. Heavy Duty Dissolved Oxygen Meter. Model

Warranty Terms. QLogic-provided cables, optics and other accessories are warranted for ninety (90) days from date of purchase.

Important Operating Instructions and Warranty Information On Your New Electronic AMSEC Safe

Refer to page 6 to page 19 for detailed instructions.

Mold Alert... Operation Manual P0270

INSTRUCTION MANUAL DTH Fax: (503)

Light Meter (Foot Candles)

Important Operating Instructions and Warranty Information On Your New Electronic AMSEC Safe

Microwave Meter. Instruction Manual

Dual Laser InfraRed (IR) Thermometer

el-720 Carbon Dioxide Gas Leak Detector User s Guide

User's Guide Integrating Sound Level Datalogger Model

Tipping Bucket Rain Gauge Models 6011-A 6011-B

Instruction Manual HI Refractometer for Sucrose Measurements

In-Situ Inc. Warranty / Terms & Conditions / Software License. This warranty policy applies to items that shipped prior to January 1, 2012.

TABLE OF CONTENTS 11.0 WARRANTY

Ground Resistance Clamp-On Tester

SINGLE RANGE DS METERS Operation Instructions

RT-200 HI-TEST ROPE TESTER

Intelli-Time Alarm Clock model 13027

Dual Laser InfraRed (IR) Thermometer with Color Alert

USER MANUAL. Bottom Loading Bottled Water Dispenser SAVE THIS MANUAL FOR FUTURE USE. Model #

Compact ph Measuring Instruments

TEMPERATURE SENSOR USER MANUAL

user s manual Battery Case model #: SPB3200 Battery Case Charger for Samsung Galaxy S 4

CM100. Carbon Monoxide Meter. Users Manual Mode d emploi Bedienungshandbuch Manual d Uso Manual de uso Användarhandbok

User's Guide. Integrating Sound Level Datalogger. Model Introduction

Thermistor Thermometer MODEL NO

Dual Laser InfraRed (IR) Thermometer

BC-5000 OPERATIONS MANUAL BATTERY CAPACITY TESTER COFKO LLC.

Temperature, Humidity & Dew Point Chart Recorder

Retractable Screen. Replacement Screen Instructions

Thermocouple Thermometer Models

Soil Sensor Reader PRODUCT MANUAL

Single Port T1/E1 Tap

Wolverine Data PASS Portable Scanner User Manual V1.0

ph Measurements of Common Substances

MTV-FS1 / FS1T / FSB375

DREAMLINE EXCLUSIVE LIMITED WARRANTY

User's Manual. Model Laser Photo / Contact Tachometer. Introduction

Start Here Series. All-in-One Printer. Print Copy Scan. Includes Information on the: ESP 3250 All-in-One Printer ESP 3260 All-in-One Printer

Touchless Forehead Thermometer

the Company will not warrant ANSI A156.2 Grade 2 lever Product installed in educational facilities and student housing.

EVAPORATIVE AIR COOLER INSTRUCTION MANUAL

Installation and Operation Manual. Digital Remote Meter for Monitoring System Performance. Version: RM-1

Commercial Cardiovascular Equipment

Instruction Manual. Fun Pop 8oz. Popper

American Dish Service

Ozone Generator Manual

NFC Communication Tray Model: HHX-IT3-Z

User Manual. Humidity-Temperature Chart Recorder. Model RH520

Data-Logging Rain Gauge PRODUCT MANUAL

User's Guide. ExStik DO600. Dissolved Oxygen Meter RECALL. Dissolved Oxygen DO600

Transcription:

Operator s Manual 4.24 ph 4.24 ON Newport Electronics, Inc.

Additional products from Newport Electronics, Inc. THE NEW STANDARD FOR QUALITY Clock/Timers Counters Flow Sensors Frequency Meters Multimeters On/Off Controllers ph Controllers ph Electrodes ph Pens PID Controllers Printers Process Meters Rate Meters Recorders Relative Humidity RTDs Soldering Iron Testers Strain Gauge Meter Thermistors Thermocouplers Thermowells Timers Totalizers Transmitters Voltmeters Wire In the USA and Canada: 800-NEWPORT In Mexico 95-800-NEWPORT Or call your local Newport Office. This documentation may not be copied, photocopied, reproduced, translated, or reduced to any electronic medium or machine readable form, in whole or in part, without prior written consent of NEWPORT ELECTRONICS, INC. 1995 Newport Electronics, Inc. All rights reserved. This product may be covered by one or more of the following patents: United States Patents Des. 336,895; 5,274,577 France Brevet No. 91 12756 Spain 2039150 United Kingdom Patent No. 2248954 and other international patents pending From the technical library of:

Warranty All Products from NEWPORT ELECTRONICS, INC. are warranted against defective material and workmanship for a period of one (1) year from the date of delivery. If the unit should malfunction, it must be returned to the factory for evaluation. NEWPORT s Customer Service Department will issue an Authorized Return (AR) number immediately upon phone or written request. Upon examination by Newport, if the unit is found to be defective it will be repaired or replaced at no charge. However, this WARRANTY is VOID if the unit shows evidence of having been tampered with or shows evidence of being damaged as a result of excessive corrosion; or current, heat, moisture or vibration; improper specification; misapplication; misuse or other operating conditions outside of NEWPORT s control. Components which wear or which are damaged by misuse are not warranted. These include contact points, fuses, and triacs. In addition to NEWPORT s standard warranty period, NEWPORT ELECTRONICS will extend the warranty period for one (1) additional year only if the warranty card enclosed with each instrument is returned to NEWPORT. Newport is glad to offer suggestions on the use of its various products. Nevertheless, NEWPORT warrants only that the parts manufactured by it will be as specified and free of defects. NEWPORT MAKES NO OTHER WARRANTIES OR REPRESENT- ATIONS OF ANY KIND WHATSOEVER, EXPRESSED OR IMPLIED, EXCEPT THAT OF TITLE, AND ALL IMPLIED WARRANTIES INCLUDING ANY WARRANTY OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE ARE HEREBY DISCLAIMED. LIMITATION OF LIABILITY: The remedies of purchaser set forth herein are exclusive and the total liability of NEWPORT with respect to this order, whether based on contract, warranty, negligence, indemnification, strict liability or otherwise, shall not exceed the purchase price of the component upon which liability is based. In no event shall NEWPORT be liable for consequential, incidental or special damages. Every precaution for accuracy has been taken in the preparation of this manual; however, NEWPORT neither assumes responsibility for any omissions or errors that may appear nor assumes liability for any damages that result from the use of the products in accordance with the information contained in the manual. SPECIAL CONDITIONS: Should this equipment be used in any nuclear installation or activity, purchaser will indemnify NEWPORT and hold NEWPORT harmless from any liability or damage whatsoever arising out of the use of the equipment in such a manner. Return Requests Direct all warranty and repair requests/inquiries to the NEWPORT Customer Service Department. BEFORE RETURNING ANY PRODUCTS(S) TO NEWPORT, PURCHASER MUST OBTAIN AN AUTHORIZED RETURN (AR) NUMBER FROM NEWPORT S CUSTOMER SERVICE DEPARTMENT (IN ORDER TO AVOID PROCESSING DELAYS). The assigned AR number should then be marked on the outside of the return package and on any correspondence. The purchaser is responsible for shipping charges, freight, insurance and proper packaging to prevent breakage in transit. NEWPORT s warranty does not apply to defects resulting from action of the buyer, mishandling, improper interfacing, operation outside of design limits, improper repair, or unauthorized modification. FOR WARRANTY RETURNS, please have the following information available BEFORE contacting NEWPORT: 1. P.O. number under which the product was PUR- CHASED, 2. Model and serial number of the product under warranty, and 3. Repair instructions and/or specific problems relative to the product. FOR NON-WARRANTY REPAIRS, consult NEWPORT for current repair charges. Have the following information available BEFORE contacting NEW- PORT: 1. P.O. number to cover the COST of the repair, 2. Model and serial number of product, and 3. Repair instructions and/or specific problems relative to the product.

For technical or application assistance please call: Newport Electronics, Inc. 2229 South Yale Street Santa Ana, CA 92704-4426 TEL: (714) 540-4914, (800) NEWPORT FAX: (714) 546-3022 Newport Technologies Inc. 976 Bergar Laval (Quebec) H7L5A1, Canada TEL: (514) 335-3183 FAX: (514) 856-6886 Newport Electronics Ltd. Unit 25 Swannington Road Cottage Lane Industrial Estate Broughton Astley Leicestershire England, LE9 6TU TEL: 44 (1455) 285998 FAX: 44 (1455) 285604 Newport Electronics B. V. Postbus 8034 1180 LA Amstelveen The Netherlands TEL: 31 (20) 6418405 FAX: 31 (20) 6434643 Newport Electronics Spol S.R.O. Ostravska 767 733 01 Karvina Czech Republic TEL: 42 (69) 6311899 FAX: 42 (69) 6311114 Newport Electronics GmbH Daimlerstrasse 26 D-75392 Deckenpfronn Germany TEL: 49 (07056) 3017 FAX: 49 (07056) 8540 Newport Electronics S.A.R.L. 9 rue Denis Papin 78190 Trappes France TEL: 33 (1) 30.62.14.00 FAX: 33 (1) 30.69.91.20 In Mexico TEL: 95-800-NEWPORT 12952ML-01

TABLE OF CONTENTS PH-2 Page Section 1 Unpacking... 2 Section 2 General Description... 3 Section 3 Setting Up the Meter... 4 Installing the Battery... 4 Section 4 Operating Instructions... 5 Section 5 Operating Tips...6 Section 6 Calibrating the Meter... 7 Section 7 ph Electrode Care...8 Section 8 ph Electrode Replacement...9 Section 9 Table of ph values...10 Section 10 Specifications/Accessories... 11 1

Unpacking Remove the Packing List and verify that you have received all equipment, including the following (quantities in parentheses):. 1 soft carrying case 1 9V alkaline battery 1 bottle of buffer solution (ph 7.00) 1 Operator s Manual The carrying case contains the following: 1 small screwdriver 1 PH-2 Meter. If you have any questions about the shipment, please call the OMEGA Customer Service Department. When you receive the shipment, inspect the container and equipment for signs of damage. Note any evidence of rough handling in transit. Immediately report any damage to the shipping agent. NOTE The carrier will not honor damage claims unless all shipping material is saved for inspection. After examining and removing contents, save packing material and carton in the event reshipment is necessary. 2

General Description The NEWPORT PH-2 meter is an ideal ph meter for general purpose measurements in the plant, production line or lab. The unit has a 3 1 /2" digit LCD display that gives a 0.01 ph resolution. The PH-2 meter is supplied with electrode, screwdriver, ph 7 buffer and vinyl case. An optional item for this meter are the replacement ph electrodes - NEWPORT part numbers PHE-8100/N and PHE-8136/N. Parts of the Meter ph electrode Do not immerse connector Electrode pivot hinge Display ph Lo Batt ON/OFF button ph 4.24 ON Adjustments potentiometers: Slope Temp.Comp. Cal Battery compartment 9V transistor battery Battery compartment door Figure 1. Parts of the Meter 3

Setting up the Meter Installing the Battery (Fig 2) Carefully remove the meter from the carrying case making sure you don t lose the small screwdriver and detergent in a small plastic bag. To install/change the battery, do the following: 1. Insert your thumb in the recessed area of the battery compartment door and pull it away from the display. 2. Snap the 9V alkaline battery into the battery clip. 3. Place the battery clip/battery assembly at the top of the battery compartment. 3. Replace the battery compartment door and snap into place. ON Battery Terminals Battery Compartment Battery 2 1 Battery Compartment Door Figure 2. Installing the Battery 4

Operating Instructions When you are ready to take your measurement(s), you must first remove the protective bottle. The ph electrode has the soaker bottle in place to protect the glass bulb from contamination and to prevent the electrode from drying out. 1. Hold part of the electrode shaft and the white cap with one hand, with thumb and forefinger of the other hand loosen the bottle a couple of turns and slide the bottle and cap off carefully. 2. Slide the battery compartment door open to the first stop and locate the TEMPCO (Temperature Compensation) screw. 3. Adjust the TEMPCO screw to the approximate temperature of the solution to be measured and close the battery compartment door. 4. Insert the ph probe into the test sample. SIDE VIEW 1 2 HOLD THIS AREA OF INSTRUMENT WITH ONE HAND 3 LOOSEN BOTTLE WITH OTHER HAND AND PULL OFF THE BOTTLE AND CAP Figure 3. How to Loosen Bottle 5

5. Press the ON button and hold to observe the ph reading. Allow 10 to 15 seconds for the reading to stabilize. 6. Remove the ph electrode and rinse thoroughly. 7. Replace the protective plastic bottle or the vinyl storage cap. Make sure the bottle or cap is filled with ph 4 buffer solution (preferably) or tap water. Operating Tips 1. ph electrode should be rinsed thoroughly in tap water after each test. 2. Make sure to keep the electrode in the plastic bottle between uses. 3. Keep these storage devices filled with 4 buffer (preferably) or tap water. DO NOT USE DISTILLED WATER. 4. Remove battery if the ph meter will not be used for an extended period of time. 5. For best results, perform a twopoint calibration using two buffers. One should always be a ph 7.00 buffer and the second buffer being used would depend on the application. (Buffer ph 4 for acidic solutions and Buffer ph 10 for basic solutions). 6. Do not immerse electrode in ph 10 buffer except when necessary for calibration. 6

Calibrating the Meter The meter is factory calibrated prior to shipping. However, since the electrode outputs change with age and condition it is important to calibrate with fresh ph buffers. For best results, calibrate ph with a buffer that is within 3 ph units of the test sample. 1. Rinse the ph electrode in tap water. 2. Insert ph electrode in a fresh ph buffer solution. 3. Slide back the battery compartment door to the first stop, exposing the adjustment screws. 4. Measure the temperature of the buffer solution. 5. Adjust the TEMPCO screw to the corresponding temperature value. 6. Observe the ph reading and adjust the "Cal" screw to ph 7 if required. 7. Remove ph electrode and rinse in distilled water. 8. Insert in a ph 4 if measuring an acid solution, or ph 10 buffer if measuring an alkaline solution. 9. Adjust the slope screw until the measurement value corresponds with the ph 4 or ph 10 buffer. 7

ph Electrode Care The ph Electrode supplied with the NEWPORT model PH-2 ph meter uses the industry standard BNC type connector. In addition to the "stick" electrode which comes standard with the meter, NEWPORT offers an electrode on a 36" cable which is ideal for table-top applications. The PH-2 ph meter can also be used with hundreds of special purpose ph electrodes available from NEWPORT. PH Electrodes must be kept moist. The ph electrode was shipped stored in a soaker storage bottle or vinyl cap, depending on model. The storage solution contained in the bottle is a potassium chloride solution. Do not be alarmed if white crystals form at the end of the electrode. It is simply potassium chloride. Rinse with water to dissolve the crystals before using the electrode. For storage, place the electrode back in the soaker bottle. If the potassium chloride solution evaporates or is lost, simply use ph buffer 4.0 or ph buffer 7.0 supplied for storage. DO NOT use distilled or deionized water as this will drastically reduce the electrode lifespan. If the ph electrode should dry out, soak the electrode up to 2 hours in ph buffer 4.0 solution. If the electrode is left dry for an extended period of time, rinse in a 10% HCl solution for 10 seconds. Rinse with tap water and store in a KCl solution overnight. This may regenerate the ph electrode. 8

ph Electrode Replacement Tilt Stand Even with the best of care, ph Electrodes do not last forever. As with batteries or light bulbs, exactly how long a ph Electrode will provide satisfactory performance depends largely on each user's application as well as the care taken in use and storage. Inaccurate or unstable ph readings, drift, slow response, and difficulty in calibration are usually indications that the ph electrode has exceeded its useful life. Replacement electrodes are available from NEWPORT Engineering. (Part number PHE-8100/N and PHE-8136/N. The vinyl coated wire tilt stand folds flat against the meter handle, or can be completely removed and later snapped back in place. It is particularly useful for benchtop applications with electrode cable extensions. 9

MID-POINTS OF ph RANGES FOR PROCESS CONTROL ph VALUES OF SOME COMMON SUBSTANCES EXTREMELY ALKALINE BOTTLE WASHING COPPER PLATING BRASS PLATING LIME-SODA SOFTENING SALT WATER AQUARIUM SWIMMING POOL WATER FRESH WATER AQUARIUM BREWING PROCESS NICKEL PLATING 14.0 13.0 12.0 11.0 10.0 9.0 8.0 7.0 6.0 HOUSEHOLD LYE BLEACH AMMONIA MILK OF MAGNESIA BORAX BAKING SODA SEA WATER BLOOD DISTILLED WATER MILK CORN FOOD PROCESSING PICKLE PROCESSING PHOTOENGRAVING 5.0 4.0 3.0 2.0 BORIC ACID ORANGE JUICE VINEGAR LEMON JUICE EXTREMELY ACID 1.0 0.0 BATTERY ACID Table of ph Values Common Industrial and Household products 10

Specifications Range: 0 to 14.00 ph Resolution: 0.01 ph Accuracy: ±0.2 ph Temperature Compensation: Manual 0 to 100 C Power: 9V battery Accessories PHE-8100/N PHE-8136/N Replacement ph stick electrode ph extension cable, triaxial connector 11

PHH-81A NOTES 12