ph meter Care and use guide

Similar documents
Care and use guide. Contents. page

Care and use guide. Contents. a handy solution made easy. page

Bluelab Soil ph Meter Instruction Manual

Care and use guide. Contents. a handy solution made easy. page

Instruction Manual Temp 4/5/6 Temperature Meter Series

Milwaukee USER MANUAL. Milwaukee. Smart DO Meter PORTABLE DISSOLVED OXYGEN METER MODEL: SM600. Authorized Dealer: ISMIL600 11/01

ExStik TM ph Waterproof Meters

Instruction Manual HI Refractometer for Refractive Index and Brix Measurements

MODEL 430 PORTABLE ph/conductivity METER OPERATING MANUAL

Please read and keep these instructions. Run water through your machine before first use

el-720 Carbon Dioxide Gas Leak Detector User s Guide

OPERATION MANUAL. Pen type, separate electrode SOIL PH METER Model : PH-220S

User Guide. ExStik TM ph (PH100 & PH110) and ORP (RE300) Waterproof Series Pens. Patent Pending

Milwaukee USER MANUAL

Electric Kettle. Model: SK-1717 INSTRUCTIONS MANUAL

Measuring ph in Water or CaCl2 Using a ph Meter. Compiled by Darren Murray, June 30, 2011 TABLE OF CONTENTS OVERVIEW 3

digital fever alert ear thermometer suitable from birth instruction manual

AIRMoN, ph and Conductivity Field Measurement

RT-1261A Ear and Forehead Thermometer Owner s Manual

User Guide. Heavy Duty Dissolved Oxygen Meter. Model

Tympanic Thermometer

USER INSTRUCTIONS FOR 10 LITRE PORTABLE DEHUMIDIFIER MODEL NO. DHMD102

Instruction Manual HI Refractometer for Sucrose Measurements

Thermistor Thermometer MODEL NO

Wolverine Data PASS Portable Scanner User Manual V1.0

Instruction Manual ph 5+ ph 6+ Ion 6+ Technology Made Easy...

SINGLE RANGE DS METERS Operation Instructions

DX-395. FM/AM/SW1/SW2 PLL Synthesized Receiver OWNER S MANUAL. Cat. No Please read before using this equipment.

PROCEDURE COVERSHEET. Document Section: CHEMISTRY Author: JOANNE WONG Date Authored: JAN In Use Date: 2/1/2011 Discontinued Date:

The Determination of an Equilibrium Constant

ThermoScan Instant Thermometer IRT 1020 Type 6005 Home Model

San josé OWNER S MANUAL

User's Guide. ExStik DO600. Dissolved Oxygen Meter RECALL. Dissolved Oxygen DO600

UltraBasic Benchtop ph Meter Operation Manual

Instruction Manual HI Portable Waterproof Microprocessor Dissolved Oxygen Meter

LASER DIAGRAM TABLE OF CONTENTS. SKY Technologies Inc. Laser Diagram. Technical Specifications. Laser Operation.

Hygro-Thermometer + InfraRed Thermometer Model RH101

MAINTENANCE & TROUBLESHOOTING

USER MANUAL. Bottom Loading Bottled Water Dispenser SAVE THIS MANUAL FOR FUTURE USE. Model #

3 WATT LED SPOTLIGHT Model No. SLM

Thermocouple Thermometer Models

SECUREPAK DIGITAL TORQUE TESTER

INSTRUCTIONS FOR ANALOGUE QUARTZ AND MECHANICAL WATCHES

Refer to page 6 to page 19 for detailed instructions.

Direct Measurement Method Method to 20.0 mg/l (or 0 to 200% saturation) O 2 Clark-type Amperometric Sensor

Introduction 1 The system 1 The meter 2 The display 3 The mode 3 The measurement 4 Coding the meter 4 How to obtain a drop of blood 6 Application of

BASIC BODY COMPOSITION SCALE

FARMEX HT-PRO OPERATING INSTRUCTIONS PORTABLE MOISTURE AND TEMPERATURE TESTER FOR BALED HAY

MAP COFFEE MIA CAPSULE COFFEE MACHINE INSTRUCTION MANUAL MODEL: CM4725. Read this manual thoroughly before using and save it for future reference

EASIDEW PORTABLE HYGROMETER INSTALLATION, OPERATION AND MAINTENANCE MANUAL

Instruction manual. VWR unstirred water baths

NewAir AC-10000E, AC-10000H Portable Air Conditioner Owner s Manual PLEASE READ AND SAVE THESE INSTRUCTIONS

AutoRanging Digital MultiMeter

NESCAFÉ Solution 8/60 Beverage System. Operations Manual

Pro1030 USER MANUAL. English

Dissolved Oxygen Sensors

RS Stock No Instruction Manual RS-1340 Hot Wire Anemometer

Optical Power Meter. Specification & User Manual

DC REFRIGERATORS 12/24 VOLTS INSTALLATION AND OWNER S MANUAL

Portable Air Conditioner. OWNER S MANUAL Read these instructions before use. Model: MF08CESWW. Voltage rating: 115V~60Hz Power rating : 800W

WHEN TO CHANGE YOUR BRITA MAXTRA CARTRIDGE

Electrical Stability Tester, Model 23E Instruction Manual Manual No , Revision B Instrument No

Instruction Manual. Image of SP-3015 & SP Important Safeguards. Automatic Dispensing Hot Water Pot with Reboil Function

orlando OWNER S MANUAL

e I N S T RUC TION M ANU A L

MODEL 970 DISSOLVED OXYGEN METER OPERATING MANUAL

Forehead. Use and Care Manual. Thermometer IMPORTANT! READ AND SAVE THESE INSTRUCTIONS. Model V977

User's Manual. Heavy Duty Dissolved Oxygen Meter Model

SAFEGUARDING THE ENVIRONMENT

PR 50 Frymaster Universal Holding Cabinet (UHC)

ph Measurement and Control

Portable Air Conditioner. OWNER S MANUAL Read these instructions before use. Model: MN12CES / MN10CESWW

INSTRUCTION MANUAL DTH Fax: (503)

Tassimo The Art of the Perfect Cup

Portable Air Conditioner. OWNER S MANUAL Read these instructions before use. Model: MM14CCS. Voltage rating: 115V~60Hz Power rating : 1400W

4.3-inch Back-Up Camera

EXERGEN. English. TemporalScanner TM. Accurate Temperature with a Gentle Forehead Scan. Operators Manual for TAT-5000

Contents Contents Contents Overview Charging your headset Wearing the headset Powering on the headset Connecting your headset for dictation

DISSOLVED OXYGEN PROBE

White rust on galvanized and galvanized pre-painted steel. Technical Information

WS-9005TWC 915MHz WIRELESS RAIN GAUGE INSTRUCTION MANUAL

INVERTER GENERATOR OWNER S MANUAL FOR YOUR SAFETY PLEASE READ THESE INSTRUCTIONS CAREFULLY AND RETAIN THEM FOR FUTURE USE.

CQ-Series. User Manual. American Weigh Scales, Inc. CQ-350 (350x0.1g) CQ-500 (500x0.1g) Digital Pocket Scale . = + CALC AC CE % TARE OFF ON MC MR CALI

AN500T, AN1000, AN1000T, AN1500, AN1500T AN2000, AN2000T

LCD BacPac. User Manual + Warranty Info

Digital Photo Picture Frame. Operation Manual

EP ; WO2012/080751; GB

Ground Resistance Clamp On Tester

Operating Manual Color Changing Fountains

DryWeight BulkVolume

Campus Services Hints and tips for residents

Instant Ear Thermometer

Nokia Wireless Keyboard (SU-8W) User Guide

Operating Instructions Bedienungsanleitung Mode d'emploi Instrucciones de manejo Istruzioni d'uso

Mini Power Bank and Charger

Phoenix Body Fat Scale Manual

Underwater Housing for Sony RX100 III, RX100 IV

Transcription:

ph meter Care and use guide www.getbluelab.com

Low battery indicator Bluelab ph Meter The battery operated Bluelab ph Meter measures ph levels by using the Bluelab ph Probe connected to the electronic meter. The Bluelab ph Meter has a digital readout and consists of a case and Bluelab ph Probe. ph probe connection socket (BNC fitting) Display Power button ATTENTION If it dries, it dies! Features Measures 0.0-14.0 ph Successful ph calibration indicators Low battery indicator Calibration instructions on the back of the Bluelab ph Meter Lightweight and portable Auto off Bluelab ph Probe Calibrate button ph probe storage cap ph unit Successful ph calibration indicators Bluelab ph Probe The ph probe tip must not be allowed to dry out. Always place the storage cap back onto the ph probe after each use and ensure it contains either Bluelab ph Probe Storage Solution or fresh water. Simple push button ph calibration Replaceable Bluelab ph Probe Over range and under range indicators Fully guaranteed for 5 years *6 months for the Bluelab ph Probe Large easy to read LCD display Batteries included ( x AAA) 1.0 Introduction to the Bluelab ph Meter The Bluelab ph Meter has two press buttons; calibrate and power. The power button requires a short press; release in about one second. The calibrate button requires a long press; hold for at least three seconds and release when the display starts flashing. Turning the ph meter on and off A short press of the power button will turn the ph meter on. The ph meter automatically turns off after approximately four minutes if no buttons are pressed. If the ph meter turns off before the reading is taken, short press the power button to turn the ph meter on again..0 Preparing for use The following tasks must be performed before the Bluelab ph Meter is used for the first time. 1 3 4 Hydrate ph probe a) Remove the ph probe storage cap by gripping the top of the cap and gently twisting the base one rotation clockwise to loosen slightly. Next slowly slide the cap off the ph probe. DO NOT completely remove the base of the cap from the top of the cap. b) Soak the ph probe tip in fresh water for at least one hour. Soaking the ph probe tip for 4 hours will improve the ph probe s activity and is recommended if the ph probe tip has been allowed to dry. CAUTION: Do not use de-ionized or distilled water. When the ph probe is not in use, place a small amount of Bluelab ph Probe Storage Solution or fresh water into the storage cap. Then replace the cap and store in a secure place. Insert batteries. See section 5. Connect ph probe Connect the ph probe to the ph meter by lining up the lugs of the BNC fittings. Fasten securely by pushing the ph probe connector on and twisting one quarter turn. Removing ph probe storage cap Fresh water Hydrating the Bluelab ph Probe Inserting Twisting Attached Calibrate the ph Calibrate the ph meter by following the instructions in section 3 of this manual. This must be done before the ph meter is used for the first time.

3.0 Calibration ph calibration is required before first use and then monthly to ensure readings are accurate. For accurate ph readings the ph probe is cleaned and recalibrated when: The reading is different to what you were expecting. The ph probe is replaced with a new one or is The batteries have been removed or changed. disconnected from the ph meter. The calibration indicators have disappeared. When calibrating the ph after first use the ph probe needs to be cleaned. See ph probe cleaning in section 6. The ph probe does not need to be cleaned for initial calibration. For best ph calibration ph reading accuracy is dependant on the accuracy and age of the calibration solutions used, and use and cleanliness of the ph probe tip. Ensure the ph probe has been cleaned and rinse the ph probe tip with clean water between calibration solutions to reduce contamination of the ph solutions. Only fresh uncontaminated solutions should be used. Calibrate the ph at the same temperature as the solution to be measured. ALWAYS calibrate the ph probe with ph 7.0 then ph 4.0 or ph 10.0. The ph calibration involves cleaning the ph probe tip and then calibrating in TWO SOLUTIONS. If a reading below ph 7.0 is expected, use ph 7.0 and ph 4.0 calibration solutions. If a reading above ph 7.0 is expected, use ph 7.0 and ph 10.0 calibration solutions. Follow the steps below for ph meter calibration. Storage and use of calibration solutions Always place the lid back onto the bottle after use or evaporation will occur rendering the solution useless. Store in a cool place. DO NOT measure directly into the bottle. Tip a small amount into a clean container and discard after use. Never add water to solutions. ph reading accuracy is dependant on the accuracy and age of the calibration solutions used, and use and cleanliness of the ph probe tip. To calibrate the ph 1 Clean ph probe tip. See section 6.0. ph 7.0 calibration a) Turn ph meter on. Rinse ph probe tip in fresh water, shake off excess water and place in a ph 7.0 calibration solution. Wait for at least one minute or longer if required for reading to stablize to a constant value. b) Long press the calibrate button. When the display shows CAL release button. ph 7 indicator is displayed indicating a successful ph 7 calibration. The ph 4 indicator will now flash indicating ph 4.0 or ph 10.0 calibration is now required. c) If Err appears during the calibration process see section 9. d) The ph meter must be calibrated to two points. If after an hour the ph meter has not been calibrated with a second calibration point the calibration indicators disappear and the ph meter reverts to an uncalibrated state. Calibration is required. ph 7.0 calibration solution Successful ph 7 and ph 4 calibration 3.0 Calibration cont. 3 ph 4.0 / 10.0 calibration a) Rinse the ph probe tip in fresh water, shake off excess water and place the ph probe tip in either ph 4.0 or ph 10.0 calibration solution. b) Wait for at least one minute for reading to stabilize to a constant value. c) Long press the calibrate button. When the display shows CAL release button. ph 7 / ph 4 is displayed or ph 7 / ph 10 is displayed d) The ph meter is now calibrated and ready for use. e) After 30 days, the calibration indicators disappear to let you know calibration is required. 4.0 Measuring the ph value Taking a ph reading 1 Press the power button to turn the ph meter on. Remove the storage cap from the ph probe and place the ph probe into the solution. 3 Wait 1- minutes or longer for reading to stabilize to a constant value. The ph reading is displayed. 4 If the solution you are measuring is outside the measurement range of the ph meter, a Ur (under range) or Or (over range) will be displayed. 5 Store ph probe between measurements. See section 7. NOTE: If taking readings of more than one solution, rinse the ph probe tip thoroughly in fresh water between solutions to avoid cross contamination. 5.0 Battery replacement 1 Batteries are replaced in the Bluelab ph Meter when the low battery indicator appears on screen. The low battery indicator remains on and the Bluelab ph Meter continues to operate until the batteries die or are replaced. Open battery compartment by sliding the back cover down and insert x AAA batteries as shown on the battery holder. Slide cover back on. NOTE: Alkaline batteries are recommended. IMPORTANT: Check the batteries at least once every six months for signs of deterioration, rusting or swelling. If signs of deterioration are found, clean battery holder contacts and replace batteries. Battery cover 3

6.0 Cleaning and maintenance Cleaning the Bluelab ph Probe To ensure accurate readings the ph probe tip needs to be rinsed in water after each use and cleaned prior to calibration using the following instructions. The storage cap must always be put back on after cleaning. 1 3 4 Rinse ph probe tip under fresh water. Fill small container with clean water. Add a small amount of Bluelab ph Probe Cleaner or mild detergent (dish washing liquid). Gently stir the ph probe in the mixture. Ensure that you do not knock the ph probe on the side of the container as this may cause damage to the glass of the ph probe. Rinse well under fresh running water to remove all traces of the detergent mixture. If the ph probe tip requires removal of heavy contamination: Gently brush around the glassware with a few drops of Bluelab ph Probe Cleaner or mild detergent (dishwashing liquid) and a soft toothbrush. 7.0 Storing the Bluelab ph Meter 1 Store the ph meter in a cool, dry and clean place when not in use. Keep out of direct sunlight. Keep the ph meter out of direct sunlight to prevent irreparable damage to the LCD reading display. 3 The ph meter is not waterproof but will withstand occasional water splashes. If the ph Meter is splashed, wipe dry as soon as possible. 4 Remove batteries if the ph meter is to be stored for a prolonged period. 5 Remove ph probe if storing the ph meter without use for longer than two to three weeks and check regularly that the ph probe tip has not dried out. When storing the ph probe, the ph probe tip must be kept moist. To prepare the ph probe for storage, place a small amount of Bluelab ph Probe Storage Solution or fresh water (never distilled or deionised water) into the storage cap. Then replace the cap and store in a secure place. 8.0 Bluelab ph Probe replacement The Bluelab ph Probe is the only part of the Bluelab ph Meter (except batteries) that requires replacing. ph probes do not last forever. They age through normal use and will eventually fail. To ensure you receive a long life from your Bluelab ph Probe please read the instructions provided with it. When the time comes to replace your Bluelab ph Probe all you have to do is order a replacement from your supplier! 5 Rinse ph probe tip well under fresh running water to remove all traces of the detergent mixture. 6 Calibration of the ph probe is required after every clean. See the ph calibration in section 3. When finished, always place the storage cap back onto the ph probe. 4

9.0 Error messages An error message will only appear following ph calibration failure. Err will be displayed for a few seconds then the display will show the previous reading. Successful calibration indicators will disappear. The Bluelab ph Meter is in an uncalibrated state, therefore recalibration is required. See causes of Error messages below. Possible causes for an Err message: Calibration solutions contaminated Wrong solutions used ph probe contaminated ph probe not properly attached ph probe worn out or damaged Calibrate to ph 7.0 FIRST then to ph 4.0/10.0 10.0 Technical specifications Measurement range Resolution ph 0.0-14.0 ph 0.1 ph 11.0 Troubleshooting guide Trouble Reason Correction ph reading inaccurate ph reading does not change from solution to solution Displays low battery indicator No display Display shows Err Or Ur Displayed Contaminated ph probe. Clean ph probe (see section 6). Ensure calibration solutions are accurate. Replace if in doubt. Incorrect calibration. Wait longer for readings to stabilize before calibrating to a constant value. Calibration unreliable. Calibrate ph probe (see section 3). ph probe damaged or old. Replace ph probe. Broken glass bulb, tube or connector. Insufficient power to take a reliable reading. Batteries dead or inserted incorrectly. Problem with ph calibration. Over range ph. Under range ph. Check ph probe for damage. Replace ph probe. Replace the batteries. DO NOT use rechargeable batteries. Check batteries are inserted correctly. Replace if necessary. See error message descriptions in section 9 of this document. Solution > 14.0 ph. Solution < 0.0 ph. Check ph probe connection. ph probe could be faulty. ph meter could be wet inside. Accuracy (at 5 C/77 F) ±0.1 ph Calibration Two point ph 7.0 and ph 4.0 or ph 10.0 Temperature compensation Not applicable Operating environment 0-50 C 3-1 F Power source x AAA alkaline batteries Other functions Successful ph calibration indicator Low battery indicator Auto off function Over range and under range indicators 5

The instrument is only as accurate as the probe is clean! Bluelab cleaning kits Probe cleaning is one of the most important parts of owning and operating any Bluelab meter, monitor or controller. If the probe is contaminated (dirty) it affects the accuracy of the reading displayed. The probe surface is where the instrument takes the reading of the solution. The information is sent back from the probe to the electronic brain of the instrument. A calculation is then done in the instrument s brain or micro computer and a reading is displayed. If the information sent back from the probe is inaccurate due to probe surface contamination then the reading will be inaccurate. Cleaning the probes is a very easy task and will prolong the life of the probes. The Bluelab cleaning kits have it all there for you: Bluelab ph Cleaning and Calibration Kit: Bluelab Conductivity Probe Cleaning Kit: Full colour instructions Calibration solutions Decanter vessels Bluelab ph Probe Cleaner Toothbrush Full colour instructions Bluelab Conductivity Standard Solution Decanter vessel Bluelab Conductivity Probe Cleaner Bluelab Chamois (probe cleaning instrument)

Product guarantee Bluelab ph Meter Bluelab Corporation Limited guarantees this product for a period of 5 years (60 months) from the date of sale to the original purchaser. (This guarantee does not cover the Bluelab ph Probe. The Bluelab ph Probe is covered by a separate 6 month guarantee.) The product will be repaired or replaced should it be found faulty due to component failure, or faulty workmanship. The faulty product should be returned to the point of purchase. The guarantee is null and void should any internal parts or fixed external parts be tampered with or altered in any way, or should the unit have been incorrectly operated, or in any way be maltreated. This guarantee does not cover reported faults which are shown to be caused by any or all of the following: Contaminated measuring tip (see instruction manual for cleaning instructions), flat or damaged batteries or batteries that have been incorrectly inserted, or damaged battery contacts or connections caused by incorrect battery replacement, or ingress of moisture into the meter case. NO RESPONSIBILITY will be accepted by Bluelab or any of its agents or resellers should any damage or unfavourable conditions result from the use of this product, should it be faulty or incorrectly operated. Please register your guarantee online at: www.getbluelab.com Or fill out the form below and post, email or fax to: Bluelab Corporation Limited 8 Whiore Avenue, Tauriko Industrial Park, Tauranga 3110, New Zealand Phone +64 7 578 0849 Fax: +64 7 578 0847 Email: support@getbluelab.com Product details Product name Serial number Date purchased Purchaser details Purchaser s name Address City Country Email (optional) Purchased from (Dealers details) Purchased from Address City Country Phone number (optional)

Bluelab ph Meter guarantee. The Bluelab product range all come with a free repair or replacement guarantee for your added benefit. If you need assistance or advice - we re here to help you. Phone: +64 7 578 0849 Fax: +64 7 578 0847 Email: support@getbluelab.com Looking for specifications or technical advice? Visit us online @ www.getbluelab.com Bluelab Corporation Limited 8 Whiore Avenue, Tauriko Industrial Park, Tauranga 3110, New Zealand Under no circumstances shall Bluelab Corporation Limited be liable for any claims, losses, costs and damages of any nature whatsoever (including any consequential loss) that result from the use of, or the inability to use, these instructions. Instruction Manual, Version 0: 01041/00771_0711 Copyright 011, all rights reserved, Bluelab Corporation Limited