No stress implantology

Similar documents
NARROW DIAMETER implant

RESTORING STRAUMANN IMPLANTS WITH LOCATOR ABUTMENTS

Straumann Dental Implant System. Fax Order Form Collection.*

Implant Systems MAX LOGIC MONO. Today s name in tomorrow s implant technology

DESS. Screws. Tijuana Ventas: (664) /95 For all major implant systems!!

Standard Internal Hex

More than a fixed rehabilitation.

Replacement of the upper left central incisor with a Straumann Bone Level Implant and a Straumann Customized Ceramic Abutment

Gl GinGival level implant

GINGIVAL LEVEL implant

Restoration of a screw retained single tooth restoration in the upper jaw with Thommen Titanium base abutment.

Dental Implant Options in Atrophic Jaws

Restorative Guidelines

BEGO IMPLANT SYSTEMS PRODUCT CATALOGUE 2015 / Partners in Progress

Regular C/X Prosthetics. Prosthetics

Contents. Cement retained restoration. Screw retained restoration. Overdenture retained restoration. TS Implant System. 70 ComOcta Gold Abutment

Taking the Mystique out of Implant Dentistry. Dr. Michael Weinberg B.Sc., DDS, FICOI

PROSTHETIC PROCEDURE. for HG IMPLANT SYSTEM

ORTHODONTIC MINI IMPLANTS Clinical procedure for positioning. Orthodontics and Implantology

GIVE YOUR PATIENTS THE FREEDOM TO EAT, SPEAK AND LAUGH AGAIN.

ALL-CERAMIC DENTAL IMPLANT SOLUTIONS

ExFeel Internal Excellent Feeling, Excellent Implant!

BASIC INFORMATION ON THE STRAUMANN VARIOBASE ABUTMENT. Straumann Variobase Abutment

ITI Small Diameter (SD) external hex 3.25 / 3.3 external hex. ITI Standard 4.8 internal non-octagon Morse taper 4.

Modern Tooth Replacement Strategies & Digital Workflow

Implant Parts. A Radford Heath Guide 1

Implant systems Systematically perfect

Legacy3 System Overview Catalog. alog. 3.2mmD 3.7mmD 4.2mmD. Legacy mmD 5.2mmD 5.7mmD

IMPLANT DENTISTRY EXAM BANK

Smile Confidently With DIEM 2. Immediate Full Arch Rehabilitation

Don t Let Life Pass You By Because Of Oral Bone Loss

Implants of high-performance ceramic. vk-lange :44 Uhr Seite 1. One-piece precision implant. Made in Germany

What is a dental implant?

Straumann Dental Implant System. Implant Selection Guide.

Guidance for implant removal. Straumann Dental Implant System

The LOCATOR concept. Simplicity and versatility for prosthesis fixation

Implants in your Laboratory: Abutment Design

The SATURN implant by Cortex Dental Industries

. Simplification. High Performance. Safety and Longevity. The fundamental goal is to restore the quality of life of patients.

Contact: Steve Hurson VP, R & D Nobel Biocare Savi Ranch Pkwy Yorba Linda, CA (714) steve.hurson@nobelbiocare.

TRI-CAM Implant System

Implant Bar Overdenture Utilizing Locator Attachments

About DENTSPLY Implants

SCD Case Study. Treatment Considerations for Implant Rehabilitation

All-on-4 treatment concept with NobelSpeedy Groovy

Product Catalog. ERA Mini TM Dental Implant System

MS SA Implant - Narrow Ridge MS SA Implant - Denture. MS Implant - Provisional MS KIT

DENT IMPLANT restoring qualit S: of LIfE

IMPLANT SYSTEM BRIDGE RESTORATIONS WITH THE CAMLOG CROWN AND. a perfect fit

ATLANTIS abutments design guide CAD/CAM patient-specific abutments

Procedures & Products Powered by Procera. All-on-4

Simpl Implant Abutments with Atlantis CAD CAM Technology

Understanding Dental Implants

Crown and Bridge Restorations. Straumann synocta Prosthetic System

SURGICAL MANUAL. Step By Step Techniques

CAD/CAM technology supporting successful implant therapy

How To Use A Cresco

Multi-unit abutment bar overdenture

Straumann Bone Level Tapered Implant Peer-to-peer communication

Choosing the right type of abutment

High-Tech Ceramics Dental Implant System: Two Part Metal-Free Natural. User Manual. swiss made. giving nature a hand

A New Beginning with Dental Implants. A Guide to Understanding Your Treatment Options

State-of-the-art for your prostheses

Summary of Benefits. Mount Holyoke College

screw-retained single crowns using custom-cast abutments

Dott Bruno Fornengo Laurea in Medicina e chirurgia 1980 Specialista in ORTOGNATODONZIA 1984 Insegnante a contratto Università di Torino dipartimento

March 20, Dear Mr. Chen:

Sinterstation. Pro Direct Metal SLM System

COMPLETE CHOICE GUIDE

Tooth Replacement Options

The SKY Locator family

Accelerated Patient Rehabilitation

PROSTHETICS. Crown and bridge restorations with the synocta prosthetic system.

New features DWOS 3.2

Eastman Dental Hospital. Dental implants - general information for patients. Department of Restorative Dentistry

Implanting Brilliancy

Ceramics on Implants Fixed Zirconium Dioxide-Based Restorations in the Rehabilitation of the Edentulous upper Jaw

Full Crown Module: Learner Level 1

ARCS Pre-Implantology

LOMAS / MONDEFIT ORTHODONTICS. The most innovative anchorage method for tooth correction

ball abutment overdenture: chairside pick-up using existing denture

Ridge Reconstruction for Implant Placement

Like natural teeth. Treatment with dental implants is a safe, reliable and well-proven solution for permanently replacing one or more missing teeth.

BICON DENTAL IMPLANTS

The IMZ Implant System

Abutment fracture in a bridge supported by natural teeth and implants

STEP-BY-STEP INSTRUCTIONS ON TEMPORARY ABUTMENTS. Straumann Temporary Abutments, VITA CAD-Temp

Dental Implants - the tooth replacement solution

PROSTHETICS. Crown and Bridge Restorations with the synocta Prosthetic System DENTAL IMPLANT SYSTEM

NobelActive. procedures and products

Final Result 1 year later. Patient Case 19. Preoperative: Main Complaint:

procedures & products NOBELESTHETICS including Procera

While the prosthetic rehabilitation of

Another Implant Option for Missing Teeth with Challenging Symmetry Patrick Gannon, DDS and Luke Kahng, CDT

CENÍK produkce CORTEX dental implants pro rok Cat.No. Název položky: Cena bez DPH: Cena s DPH:

IMPLANT CONSENT FORM WHAT ARE DENTAL IMPLANTS?

Renaissance of One-Piece Implants


T1 LINE. Handpieces. T1 LINE supreme ergonomics in titanium.

Transcription:

2011 PRODUCTS CATALOG No stress implantology Extended range Non-contractual photos www.idcam.fr www.idisystem.fr

A word from the President Always innovating... Dear Doctor, Since 1987, IDI continues to develop new products in oral implantology. IDI was a pioneer in creating state of surface SMA Ti02, which is copied and used by other leading implantology companies around the world. Ten years later, IDI continues its advances in loading the RBS (Recovering Bone System) stop drill and bone recuperation that starts the Osteosinus technique, which is the most secure for raising the sinus path of the bone crest. This technique is accessible to all clinicians. 2010 marks the launch of the ID CAM range of implants in the United States after being successful in more than 30 countries. This new generation of implants is special because of its exterior geometric and interior connection. In the next decade, we will see a number of innovations created by our Research and Development department. Always innovating for you and with you The President ISO 9001 ISO 13485 SCC Accredited CB MS Taiwan 2 www.idcam.fr Please consult us for more information www.idisystem.fr

An outstanding facility in Europe located in Paris, Montreuil, France. Founded in 1987, IDI (Implants Diffusion International) occupies a 10,000 square foot facility located in Paris. This facility is dedicated to implantology including : Research and Development Production Center Commercial and administrative Department Training, teaching and formation center 4 5 6 7 1 SUMMARY p.3 An outstanding facility in Europe located in Paris,Montreuil, France. p.4 ID CAM Implants p.8 ID CAM Prosthetic Kits p.10 Prosthetic elements 3 p.13 The Instruments 1. IDI Headquarter in Paris Montreuil (France) 2. IDI team in our booth during ADF 2009 (French Dental Association Exhibit in Paris) 3. Training 4. 5. 6. 7. IDI production and control center 2 3 p.14 The RBS C tapered drills p.16 ID Cam Prosthetic Approach Kits p.21 Surgical Technique Loading of an ID CAM implant p.22 Guarantees and Limitations (USA Market) p.23 Sales General Conditions (USA Market) 3

ID CAM implants Interest of CSO APEX The ID CAM implant is in the spot life due to its CSO apex*. Its apex has a concave area that acts as a bone reservoir for bone grafting. The a-traumatic «Securit» round-shaped end limits the risks of damaging the sinus membrane and the dental nerve. Its peripheral and wedging groove increases the apical bone retention surface. The ID CAM S type IM implant line benefits from the SMA Ti02 state of surface initiated by IDI and used since 1987. This self-condensing implant stands 75 N.cm screwing stress without being affected. The ID CAM S implant draws special attention to itself due to its Switching Cone neck and to its cylindro-tapered body identical to a dental root. The angulation, the state and the depth of the threads are specially studied to optimize the primary stabilization in any bone density and favor the immediate loading. Switching Cone Condensing high threads *CSO : Concave Securit Osseo-wedging Anti-unscrewing groove Non-contractual photos Maxillary Self-drilling low threads Mandible CSO APEX ) Implant ID CAM S features - cylindro-tapered-shaped - 2.5 morse taper - Titan alloy TAL6VELI - SMA Ti02 state of surface - Cam retention - Switching Cone - Anti-unscrewing grooves - Progressive and condensing threads - CSO apex 4

ID CAM S ID CAM S implants range SStandard TYPE Standard Ø 4,2 All the dimensions are in millimeters HEIGHT Color code* IDCS 0842 Standard Ø 5,2 8 IDCS 0852 NB : the 8mm ID CAM implants (P/N IDCS 0842 and IDCS 0852) do not have any CSO APEX. 8 Ø 3,5 Ø 4,2 Ø 5,2 LENGTH 8 Important considerations: The 3.5 mm diameter implants must be used only for lower and upper lateral incisors. The 8mm ID CAM implants do not have any CSO Apex. Standard Ø 3,5 10 IDCS 1035 Standard Ø 4,2 10 IDCS 1042 LENGTH 10 ID CAM implants are furnished with a closing and a healing cap. Standard Ø 5,2 10 IDCS 1052 To improve aesthetic quality, it is recommended to position the implant under 0.5mm of the bone crest. Standard Ø 3,5 12 IDCS 1235 Standard Ø 4,2 12 IDCS 1242 Standard Ø 5,2 12 IDCS 1252 LENGTH 12 It is recommended to set as many implants as lacking natural roots in the patient mouth in order to secure the durability of the prosthesis. Standard Ø 3,5 15 IDCS 1535 Standard Ø 4,2 15 IDCS 1542 LENGTH 15 The length choice and diameter of implant must be based on the volume and density of the bone, the position of the implant in the mouth and the scan reading. Standard Ø 5,2 15 IDCS 1552 *On each implant packaging there is a small colored sticker to match with the implant height. The code for each color is related to the one found on the RBS conical drills for the ID CAM implants : " Yellow : 08 mm length " Red : 10 mm length " Green : 12 mm length " Blue : 15 mm length Please consult us for more information www.idisystem.fr www.idcam.fr 5

ID CAM implants The ID CAM M type IM implant line benefits from the SMA Ti02 state of surface initiated by IDI and used since 1987. This self-condensing implant stands 75 N.cm screwing stress, without being affected. The ID CAM M implant differentiates from the ID CAM S because of its mini threads neck, which favor immediate loading. Switching Cone Condensing mini threads Cone morse 2,5 Internal universal thread ISO Anchoring came Cone morse and identical anchoring for all ID CAM range. Condensing high threads Anti-unscrewing groove Non-contractual photos Self-drilling low threads Instructions for use CSO APEX ) 1. Use the screwdriver reference 0146, 1046, 0046, 0846 to screw the implant. 2. Use the screwdriver reference 0014, 1014, 1114, 0114 to screw the cover screw manually at 5N.cm while omitting the hinged ratchet. Implant ID CAM M features - cylindro-tapered-shaped - 2.5 morse taper - Titan alloy TAL6VELI - SMA Ti02 state of surface - Cam retention - Switching Cone - Anti-unscrewing grooves - Mini threads - Progressive and condensing threads - CSO apex 6

ID CAM M ID CAM M implants range MMini-threads TYPE Mini-threads Ø 4,2 All the dimensions are in millimeters HEIGHT Color code* IDCM 0842 Mini-threads Ø 5,2 8 IDCM 0852 NB : the 8mm ID CAM implants (P/N IDCM 0842 and IDCM 0852) do not have any CSO APEX 8 Ø 4,2 Ø 5,2 LENGTH 8 Important considerations: The 3.5 mm diameter ID CAM implants must be used only for lower and upper lateral incisors. The 8mm ID CAM implants do not have any CSO Apex. Mini-threads Ø 4,2 10 IDCM 1042 Mini-threads Ø 5,2 10 IDCM 1052 LENGTH 10 ID CAM implants are furnished with a closing and a healing cap. To improve aesthetic quality, it is recommended to position the implant under 0.5mm of the bone crest. Mini-threads Ø 4,2 12 IDCM 1242 Mini-threads Ø 5,2 12 IDCM 1252 LENGTH 12 It is recommended to set as many implants as lacking natural roots in the patient mouth in order to secure the durability of the prosthesis. Mini-threads Ø 4,2 15 IDCM 1542 Mini-threads Ø 5,2 15 IDCM 1552 LENGTH 15 The length choice and diameter of implant must be based on the bone density and the scanner reading. *On each implant packaging there is a small colored sticker to match with the implant height. The code for each color is related to the one found on the RBS conical drills for the ID CAM implants : " Yellow : 08 mm length " Red : 10 mm length " Green : 12 mm length " Blue : 15 mm length Please consult us for more information www.idisystem.fr www.idcam.fr 7

Prosthetic kits KIT A The screw-on burnout elements for any type of prosthetic reconstructions Implant analog retaining screw burnout rotational cylinder burnout anti-rotationally secured Connector bar Nylon clip 0223 0214 021801 022601 0931 0025 KIT The Fixed screw-on CoNe abutments C for an unitary implant (FMC) C300 Ø 3,5 Ø 4,2 and 5,2 C400 Non-contractual photos 0 C315 3500 0214 0223 0 C415 4200 0214 0223 15 15 C323 3515 0214 0223 C423 4215 0214 0223 23 23 3523 0214 0223 4223 0214 0223 Composition of kit C : Angled abutment including or straight anti-rotationally secured retaining screw implant analog 8

Prosthetic kits KIT B Fixed morse tapered elements to be screwed for an unitary implant. Morse tapered abutment to be screwed Abutment analog Impression full cap Burnout cap for the lab Cap for provisory tooth 0242 0142 4210 4212 4213 KIT D Fixed screw-on PLAN abutments for unitary or multiple implants (FMP) 0 D400 D415 Ø 3,5-4,2 and 5,2 420011 0214 0223 15 D423 421511 0214 0223 23 422311 0214 0223 Composition of kit D : Angled abutment including or straight anti-rotationally secured retaining screw implant analog Please consult us for more information www.idisystem.fr www.idcam.fr 9

Prosthetic elements All the dimensions are in millimeters Morse tapered abutment to be screwed Transgingival height 0,5 0242 Transgingival height 1,5 024202 Transgingival height 2,5 024203 Elements for morse tapered abutment, to be screwed Non-contractual photos Abutment analog 0142 Impression full cap 4210 Burnout cap for the lab 4212 Cap for provisory tooth 4213 10

Prosthetic elements All the dimensions are in millimeters Straight Anti-rotationally secured 15 angled Anti-rotationally secured 23 angled Anti-rotationally secured Morse tapered abutment (FMC) without shoulder retaining screw 3500 3515 3523 4200 4215 4223 Morse tapered abutment (FMC) with shoulder retaining screw Transgingival height 1,5 420001 421501 422301 Transgingival height 2,5 420002 421502 422302 Transgingival height 3,5 420003 421503 422303 Flat supported abutment (FMP) with shoulder retaining screw Transgingival height 1,5 420011 421511 422311 Transgingival height 3,0 420012 421512 422312 Please consult us for more information www.idisystem.fr www.idcam.fr 11

All the dimensions are in millimeters Additional prosthetic elements Healing screw 0213 021301 021302 021303 Burnout cylinders 021801 022601 022602 Rotational with shoulder Anti-rotationally secured, with shoulder for an unitary element Anti-rotationally secured, with shoulder, nylon for temporary tooth Impression cylinders 0221 2004 2004F Rotational Anti-rotationally secured, pick-up technique with screw Anti-rotationally secured, closed tray technique Spherical attachments 0222 Titan 022202 Titan 022203 Titan 0122 o'ring case Non-contractual photos Burnout elements 9222 0931 0025 0924 Burnout spherical attachment Burnout connector bar Nylon clip Nylon box for spherical attachment Additional elements 0212 0024 0940 Cover screw Magnetic screw Magnet 0208 0206 0214 0223 Titanium cylinder, rotational for temporary tooth Titanium cylinder, antirotationally secured for temporary tooth Retaining screw Implant analog 12

Instruments All the dimensions are in millimeters Ø 16 150 Hex-tipped screwdriver 0146 0046 0846 Long, to be used with the hinged ratchet Short, to be used with the hinged ratchet Manual screwdriver to screw the implant Screwdriver for relating instruments 0114 Long model 0014 Short model - for the cover & healing screws : 5N.cm screwing. - for the prosthetic and abutment screws : 25N.cm screwing. Hinged ratchet 415 414 416 Hinged ratchet Hinged ratchet central part Central part Instruments with dental shank 1014 22 30 22 30 1114 1046 1146 406 square-tipped instrument square-tipped instrument Hex-tipped instrument to screw the implant max. 35N.cm Hex-tipped instrument to screw the implant max. 35N.cm Instrument extension Please consult us for more information www.idisystem.fr www.idcam.fr 13

The RBS C tapered drills The bone-recovering RBS conical drills were developed and tested in several hospitals. They ease the implant setting of the ID CAM implant line. Drill head: The lower section incorporates a long cutting thread and tapers to a point at the drill head. Color coding: A colored ring on the depth stop indicates the maximum drill depth. Depth stop: The depth stop limits how deep the drill can be inserted, determining the maximum drilling depth. Non-contractual photos Markings: Markings on the shank indicate the diameter of the drill. Bone-harvesting channel: A channel between the cutting thread and depth stop is used to collect bone material for harvesting autogenous material for grafting. 14

The RBS C tapered drills All the dimensions are in millimeters RBS C drill range DRILLING LENGTH Color code* Set for ID CAM implants Ø 2,0 8 0820 Ø 3,5 8 083522 Ø 4,2 8 084227 Ø 5,2 8 085230 Ø 2,0 10 1020 Ø 3,5 10 103522 Ø 4,2 10 104223 Ø 5,2 10 105225 Ø 2,0 12 1220 Ø 3,5 12 123522 Ø 4,2 12 124223 Ø 5,2 12 125225 Ø 2,0 15 1520 Ø 3,5 15 153522 Ø 4,2 15 154223 Ø 5,2 15 155225 *On each implant s packaging there is a small colored sticker to match with the implant height. The code for each color is related to the one found on the RBS conical drills for the ID CAM implants : " Yellow : 08 mm length " Red : 10 mm length " Green : 12 mm length " Blue : 15 mm length Contents of ID CAM 2 implant set 16 drills 12 relating instruments Relating instruments Hinged ratchet 414 Instrument extension 406 Depth Tester 408 Implant paralleling help 409 Hand piece screwdriver for 30mm long prosthetic 0114 Hand piece screwdriver for 22mm short prosthetic 0014 Contra-angle screwdriver hand piece for 30mm long prosthetic 1114 Contra-angle screwdriver hand piece for 22mm short prosthetic 1014 Hand piece screwdriver for screwing the implant: 30mm long 0146 Hand piece screwdriver for screwing of the mplant:22mm short 0046 Contra-angle screwdriver hand piece for screwing the implant:30mm long 1146 Contra-angle screwdriver hand piece for screwing the implant:22mm short 1046 Non-contractual package Please consult us for more information www.idisystem.fr www.idcam.fr 15

Prosthetic approach The screw-on burnout elements for any type of prosthetic reconstructions KIT A L N O P Q S Description of kit A : L : Implant analog ref 0223 N : Burnout cylinder, rotational ref 021801 O : Burnout cylinder, anti-rotationally secured ref 022601 P : Retaining screw ref 0214 Q : Burnout connector bar ref 0931 S : Nylon clip ref 0025 Excluded from Kit A T : Impression cylinder incl. screw, ref 2004 anti-rotationally secured Pick-up technique U : Impression cylinder, rotational ref 0221 T U Non-contractual photos Screw-on unitary element - Impression taking with cylinder (ref 2004) - the model is plastered over T X P O L X Setting with the burnout element ref : 022601 16

Prosthetic approach Connector bar with clip - impression taken with impression cylinders (ref 0221 or 2004) - the implant analogs are screwed in the impression cylinders; the model is plastered over (P/N 0223) Connector bar with spherical attachments - impression taken with impression cylinders (ref 0221 or 2004) - the implant analogs are screwed in the impression cylinders and plastered over P P S N N L L Setting Screw-on solidarized abutments solidarized framework - impression taking with the impression cylinder (ref 0221) - the model is plastered over - conception of the framework with references 021801 and 0214 - realization of the ceramic work on telescopic framework U P N X L Please consult us for more information www.idisystem.fr www.idcam.fr 17

Prosthetic approach Fixed morse tapered elements to be screwed for an unitary implant. KIT B E F G H I Description of kit B :DESCRIPTIF DU KIT B : E : Morse taper abutment to be screwed ref 0242 F : Abutment analog ref 0142 G : Impression cap, full ref 4210 H : Burnout cap for the lab ref 4212 I : Cap for provisory tooth ref 4213 Non-contractual photos G Ceramic crown Temporary tooth in resin I E Impression I E X F X Example of morse taper abutment to be screwed ref :0242 18

Prosthetic approach Fixed screw-on CoNe for an unitary implant (FMC) KIT C K P L Description of kit C : K : Screw-on machined abutment 6 ref.* P : Retaining screw ref 0214 L : Implant analog ref 0223 Excluded from Kit C T : Impression cylinder including screw, ref 2004 anti-rotationally secured Pick-up technique T *Different types of abutments for implant ø 3,5 : - Straight abutment : réf 3500-15 angled abutment : réf 3515-23 angled abutment : réf 3523 *Different types of abutments for implant ø 4,2 et 5,2 : - Straight abutment : réf 4200-15 angled abutment : réf 4215-23 angled abutment : réf 4223 K X Please consult us for more information www.idisystem.fr www.idcam.fr 19

Prosthetic approach Fixed screw-on PLAN abutments for unitary or multiple implants (FMP) KIT D M P L Description of kit D : M : Flat supported abutment 6 ref.* P : Retaining screw ref 0214 L : Implant analog ref 0223 Excluded from Kit D T : Impression cylinder incl. screw, ref 2004 anti-rotationally secured Pick-up technique T Non-contractual photos *Different types of abutments for transgingival height 1.5 mm for all types of implants : - Straight abutment : ref 420011-15 angled abutment : ref 421511-23 angled abutment : ref 422311 *Different types of abutments for transgingival height 3.0 mm for all types of implants : - Straight abutment : ref 420012-15 angled abutment : ref 421512-23 angled abutment : ref 422312 M X 20

Technique for the surgery Drilling sequence for the ID CAM ( loading of an ID CAM implant IDCM 1242 ) implant 1 2 3 1 - Pilot drill of a 2mm diameter & 12mm length. 250 rounds/minute 2 - Drill at 150 rounds /minutes. drill of a 3.5mm diameter & 12mm length 3 - Drill at 150 rounds/minutes. drill of a 4.2mm diameter & 12mm length 4 5 6 4 - Screwing of the Implant : -with the help of a contra-angled hand piece and a screwdriver ref:1046 or 1146 Finish the screwing up to 1mm below the bone crest with the help of a screwdriver ref:1146 or 1046 and a hinged ratchet ref:415 5 - Screwing of the cover screw at 5N.cm DRILL TO BE USED LENGTH Color code 6 - Suture ID CAM IMPLANTS Important Considerations : ID CAM implants of 3,5 mm have only to be used for the upper lateral and lower incisors. ID CAM implants of 8mm length do not have Apex CSO. ID CAM implants come with a cover screw and healing screw. In order to optimize the aesthetic, it is recommended to set the 0,5mm implant in a sub-crestal position. It is recommended to set as many implants as lacking natural roots in the patient s mouth, in order to secure the durability of the prosthesis. All the dimensions are in millimeters Ø 4,2 Ø 5,2 Ø 3,5* Ø 4,2 Ø 5,2 Ø 3,5* Ø 4,2 Ø 5,2 Ø 3,5* 8 8 10 10 10 12 12 12 15 IDCM et S 0842 IDCM et S 0852 IDCS 1035 IDCM et S 1042 IDCM et S 1052 IDCS 1235 IDCM et S 1242 IDCM et S 1252 IDCS 1535 The choice of length and diameter of the implant must be based on the volume and density of the bone as well as the reading of the scan. Ø 4,2 Ø 5,2 15 15 IDCM et S 1542 IDCM et S 1552 Please consult us for more information www.idisystem.fr www.idcam.fr 21

Guarantees and Limitations (USA Market) Guarantees and Limitations The dentist using the IDI system including the ID CAM range must follow an in-depth training in oral implantology, integrating the proper use of the specific surgical material of this implantology system. In order to use the system, the clinician is required to: 1) Conduct an in-depth and detailed medical examination of the patient 2) Conduct oral pathology 3) Control the bone physiology 4) Study the oral anatomy 5) Control pre-medication and additional exams 6) Master the reading of the scan 7) Control the root treatments 8) Control the periodontal state and then perform the surgical and/or non-surgical periodontal treatment 9) Control the occlusion 10) Respect the bio-mechanic rules 11) Be aware of the new techniques of implant treatment in order to avoid peri-implantits. 12) Control the titanium non-allergy of the patient 13) Be informed about the failure reasons in implantology worldwide recognized by the medical world world. All implants of the ID CAM series use surgical titanium alloy (Ti6AL 4V). They present the same surface state for the last 23 years: sandblasted with a compatible titanium powder, etched with acid and thermal treatment. The clinical studies have been completed for several years. These studies confirm the biocompatibility of the surface of the IDI dental implants. Consequently, IDI nor IDA (Implants Diffusion Americas LLC) shall not be responsible for any kind of implant and prosthesis failure. IDI nor IDA does not authorize any third party to guarantee either the ID CAM (S or M) implant or the entire IDI line. IDI shall allow the distributor to exchange a defective product provided the product is in its original "packaging" for the implants, the prosthetic kits and surgical materials. If the product has been returned to IDI or IDA within eight (8) months from its delivery date, the replacement of the product may only be applicable under the conditions of submitting fully paid bills and after agreement from the Quality Department of the IDI Corporation IDA shall not be responsible for any product damaged due to the shipping. Neither patient nor clinician can blame IDI products for not meeting expectations. IDI or IDA does not guarantee the distortions or failures of the IDI range of implants if: - the patient had a trauma - the patient s jaw was used for anything else other than masticate and phonation - the occlusion rules were not respected ID CAM implants of 3,5mm diameter must be exclusively used for the replacement of the upper and lower lateral incisors due to their weak resistance to rupture. 22

Sales General Conditions Sales General Conditions (USA Market) Prices: These terms and conditions apply to all IDI products sold to its clients by IDA. In case of a conflict with the client, these conditions will prevail unless there is a separate agreement from IDA and (Implants Diffusion Americas LLC) notified in writing to the client. IDA has the right to modify the implant prices without notice, even during the period of validity. All our prices are in US dollars. Orders: Every order received, either directly or through one of our representative, must be confirmed by our US head office. Shipping charges are calculated for each order and are not included in the price of the product. For any order worth $300 or more, the shipping charge will be paid by IDA. For any order under $300, it will be paid by the client. Delivery: An approximate delivery date will be given when an order is placed with IDA. IDA shall not be subject to any penalty fees of any kind, as a result of a delay in the delivery. The client must verify the package and its contents prior to accepting delivery. If there is a problem with the product, the client will have to inform immediately the delivery company and notify it in writing on the delivery note. For any claim about the product, IDA must be informed within the first 48 hours subsequent to delivery. If an incident occurs that will affect the delivery of the product from IDA for more than 3 months, IDA reserves the right to cancel the order without paying any additional compensation and shall not be responsible for non-delivery. All our deliveries will be subject to invoices payable to IDA. IDA has the right to suspend any delivery for any payment delay by the client. Returns: Before any product can be returned to IDA, a written request explaining the reason must be submitted to and approved by IDA. Only new, non opened and unused materials could be returned within 30 days. A product with a defect shall be returned according to the guarantee terms of our company. In case of defective product, the client has to complete and file a simple report and submit to IDA s head office. Shipping cost will be at the client s responsibility. The shipping costs are the responsibility of the client. Payment: The payment of the products must be received within 15 days by the client from the billing date. Non-payment will result in putting the order on hold and late penalty fees will be assessed based on 1.5% rate interest, limitation or suspension of the client's credit or the shipping costs paid by client. No discount is authorized except with a written notice from IDA. Rights and Property: The product is considered property of IDA until final payment is received. In case of non-payment total or partial, IDA will be able to put the client on formal notice to pay and will be authorized to collect the sold products, non-used by the client. IDA will keep, as damages, the fund that may have been already paid by the client. Dispute: Other dispute conditions are only valid with our written notice Please consult us for more information www.idisystem.fr www.idcam.fr 23

Every 15 minutes an IDI implant is set in the world. Thank you for your trust and confidence Distributed by: made in France