Automatic Minimum Flow System SMA 63 and SMA 64

Similar documents
Mustang Series PRESSURE REDUCING CONTROL VALVE WITH PRESSURE SUSTAINING FEATURE. M115-2 (Globe) M (Angle) Schematic. Standard Components

Vertical selfpriming Side-Channel Pumps Type WPV

PRESSURE REDUCING CONTROL VALVE

API Flanged Safety Relief Valves Series 526 CATALOG

VAD. Variable Area Desuperheaters

VAD Variable Area Desuperheaters

Pneumatic Control and Shut-off Butterfly Valve Pfeiffer Type BR 14b/31a and Type BR 14c/31a

Instructions Manual. Electromagnetic sensor Series FLOMID FX. instrumentation for fluids. R-MI-FlomidFX Rev.: 0 English version

VdS en. VdS Guidelines for water extinguishing systems. Non-return valves. Requirements and test methods. VdS en : (01)

Ergo-Pro Single Line Solar Station Installation and Operating Instructions

CRN5-5 A-FGJ-G-E-HQQE 3x230/400 50HZ

3", 4", 6" & 8" Model H Series Alarm Check Valve Installation and Maintenance Guide

PBX Series Quick Fit Connector Bimetallic Steam Traps

Flow controller with integrated control valve (PN 16, 25, 40*) AFQM, AFQM 6 - return and flow mounting

CRANE. Σελίδα 1 από 2. Dimensions and Weights. Weight (kg) Size

BPW32 DN15, DN20 and DN25 Balanced Pressure Wafer Steam Trap

The conditions below apply to the curves shown on the following pages.

BERMAD Waterworks. Pressure Relief/Sustaining Valve. 700 Series. Model 730. Features and Benefits. Major Additional Features

S GATE KNIFE GATE VALVE WITH PNEUMATIC ACTUATOR

Installation and Commissioning Manual Solar Stations FlowCon Max Evolution II

MFP14, MFP14S and MFP14SS Automatic Pumps

Buy Karcher Parts Online: Need Technical Help? Call: Requests to:

Direct Operated Regulator for 6.0 MPa (Relieving Type) How to Order. Body size 30 40

ZOP, ZOT SIGMA PUMPY HRANICE GEAR PUMPS

M A N U A L

CRN A-F-G-E-HQQE 3x400D 50 HZ

Self-contained valve functions as integral check valve, flow sensing element and bypass control valve.

Installation and Operating Instructions Installation Instructions for SS EPE-316L Series

4" SUBMERSIBLE PUMPS

! WARNING. Before using product, read and understand instructions.

FIXED DISPLACEMENT HYDRAULIC VANE PUMPS BQ SERIES

OPERATING AND MAINTENANCE INSTRUCTIONS PUMP TYPE

FIXED DISPLACEMENT HYDRAULIC VANE PUMPS BQ SERIES

Chapter 5: Flow Valves

Proportional pressure regulators VPPE

Max. Head (m) LVR V , Hz ~ 220 V Oval Flange G1. LVR V , Hz ~ 380 V Oval Flange G1

Grooved gaskets. Types of gaskets

FIXED DISPLACEMENT HYDRAULIC VANE PUMPS BQ SERIES

Spira-trol TM Two-port Control Valves EN Standard KE, KF and KL DN15 to DN300 and ASME Standard KEA, KFA and KLA ½" to 12"

Why and How we Use Capacity Control

Assisted lift operated 2/2-way solenoid valves Type EV250B

SunMaxx Solar Filling Station Operating Instructions

slide flange slide ring

Ball valve C 16 valve ball completely moulded in place, extremely low clearance volume, high k v value

RUBBER SLEEVE KNIFE GATE VALVE

Self-operated Temperature Regulators Temperature Regulator Type 1u

GS-General Service Control Valves

Valve series MN-06 acc. to NAMUR, 3/2-way G1/4 750 Nl/min (0.762 Cv)

27 July 2009 I /08. Klenk GmbH Eichelstraße 15, D Bodnegg-Rotheidlen

Signature and ISX CM870 Fuel System

Automatic Bypass Control AVDO

SCP ISO. Other advantages: SCP ISO is a series of piston pumps with a fixed displacement for mobile and stationary hydraulics.

DARTMOUTH COLLEGE DESIGN January 3, 2012 & CONSTRUCTION GUIDELINES

This instruction is valid for all ACD pump models shown on page 2

SJT / SJM / SJP Large Vertical Pumps

Air Eliminators and Combination Air Eliminators Strainers

Pneumatic actuators The Original! Technics of the top class.

AIR OPERATED OIL PUMPS AND KITS

Control blocks for two-hand start ZSB

The Axial Flow Valve. Class 300/ SERIES

Unit 24: Applications of Pneumatics and Hydraulics

3-Way heavy duty flow control, with pressure compensated and solenoid controlled priority flow

IMPORTANT SAFETY NOTICE

Self-operated Pressure Regulators Universal Pressure Reducing Valve Type 41-23

Butterfly Valves PN 6/10/16 for flanged connection

How To Use A Flowmeter

PVH131/141 Variable Displacement Piston Pump - 11 Design

- CONSTRUCTIONS 300 SECTIONAL VIEW 300 MECHANICAL SEAL DIMENSIONS AND WEIGHT 400 PUMP 400 PACKING 401

ENGINE Dinli 904 D

Overview. Introduction Cooling Tower Basics Principles of Operation Types of Cooling Towers Common Applications Design Considerations

Industrial Process Pump Safety Manual IMPORTANT SAFETY NOTICE

Thermostatic actuator RAVV - for 2-way valves RAV-/8 (PN 10), VMT-/8 (PN 10), VMA (PN 16)

SUPRApak S Series Filter Housings SUPRApak Filtration For Small Batch Depth Filtration

Seated valves (PN 16) VF 2 2-way valve, flange VF 3 3-way valve, flange

PRESSURE REDUCING VALVES

BOWIE PUMPS OPERATION - MAINTENANCE

Pilot Operated Pressure Reducing Valve PRV 47 (Steel) PRV47I (St.Steel)

Valves dimension of pressure (lbs) ANSI2500 ANSI1500 ANSI900 ANSI600 ANSI300 ANSI150. Inch. from 1/2 up to 6

PART 2 FORKLIFT HYDRAULIC SYSTEM

2-Way heavy duty flow control, with pressure compensated, solenoid and load sensing controlled priority flow

BERMAD Waterworks. Pressure Reducing Valve. 700 Series. Model 720. Features and Benefits. Major Additional Features

Buy Karcher Parts Online: Need Technical Help? Call: Requests to:

Art.S001-S002 SOLAR MODULE WITH DELIVERY AND RETURN CONNECTIONS

Type and Type Pneumatic Control Valves. Type (left) and Type (right) Mounting and Operating Instructions EB 8026 EN

Hose and Tube Fittings Series 1-3

Ve-Lock manufactures Needle Valves from Solid bar stock Materials & all parts details are as below:

AURORA AND 1040 Series SUCTION DIFFUSERS, COMBINATION AND TRIPLE DUTY VALVES

Hydraulic multidisc Brake H420

SPERRYN GAS CONTROLS DELTA FLUID PRODUCTS LIMITED

Pneumatic Shut-off Butterfly Valve Type 3335/31a SRP or DAP

SUPRApak M Series Filter Systems SUPRApak Filtration For Medium Batch Depth Filtration

Digital inductive conductivity transmitter

Rexroth Hydraulic Pump A10VO Series User Manual

PVM Piston Pumps Service Manual

Nozzle Check Valves. NOREVA nozzle check valves are used

300 Series PA Pump and Cooler Assemblies

Type 3353 Angle Seat Valve

T U R B I N E G A S M E T E R

ball valves Flomite 71 Series 2-way Integral Panel Mount Ball Valves

Pressure regulating valve with modulating kit, type DRV

Transcription:

Figure 1 Automatic Minimum Flow System SMA 63 Advantage and Utility assurance of the required pump minimum continuous safe flow no inadmissible temperature increase in the pump; avoidance of cavitations in the pump; avoidance of pump and plant damages integrated non-return valve in the main delivery stream avoidance of reverse operation of the pump; allows parallel pump operation favorable NPSH-value of the plant (NPSH A) and the pump (NPSH R) lower capacity in operating point because of automatic closure of the minimum flow line lower prime mover power requirement lower facility costs Application The Automatic Minimum Flow System SMA 63/64 (AR-Valve) is a pump protection device. It automatically protects centrifugal pumps from damage which might occur through partial evaporation of the fluid content during low load operation. Power Stations, Nuclear Power Stations Chemical industry Petrochemical industry Off-Shore-Industries Steel works Paper industry Special Features wear resistant On/Off bypass regulation for high pressure applications with a pilot operated plunger non-return-function in main direction to the process multistage reduction of pressure and flow rate in the bypass - low cavitations and of low noise without additional auxiliary energy and measuring technique less pressure loss mounting position vertical* or horizontal all internal parts are made out of stainless steel reliable and durable Design and Operation For the main flow - to the process - the valves have an inlet flange DN 1 and an outlet flange DN 2. The minimum flow is going out through an additional branch DN 3 back to the reservoir. As soon as the pump capacity drops below a predetermined flow rate, the AR-valve opens complete the bypass to maintain the pump minimum flow rate. This rate is maintained even if the flow in main direction to the boiler or process is completely shut off. The Automatic Minimum Flow System automatically opens and closes the bypass corresponding to the main flow rate. This flow controlled function operates without additional auxiliary energy. Through actuation of the bypass via a pilot operated plunger (15) the bypass can be opened resp. closed completely. This On-Off- Regulation of the Bypass makes it possible to increase the load limit from 220 bar to 400 bar. The preferred duty is in the range of nominal pressure 250 to 400 bar resp. ANSI 2500 lbs. The pressure and flow reduction to the minimum flow requirements in the bypass line takes place through a multistage throttle system. The pilot unit utilizes the medium and the pump pressure for actuation of the piston (15). Two pilot valves control the pump pressure in front of resp. behind the piston and consequently the position of the piston is ON resp. OFF regulated. The pilot valves are actuated depending on the main flow through the cone (3) position via the lever (32). With the integrated fine throttle (37) a cushioned move of the piston (15) is achieved. Technical Data SMA 63 / SMA 64 Medium Fluids without solids Viscosity 150 cst Temperature -10 C up to +300 C* -14 F up to +572 F* Nominal width DN main direction 80 up to 200 mm; (3 up to 8 )* bypass 32 up to 100 mm (1,25 up to 4 )* Pressure rate PN 250 up to PN 400* ANSI 1500 up to ANSI 2500 lbs* Bypass-control On/Off regulated with throttle Material casing parts 1.0460 (A105)* ASME in () 1.0566 (A350-LF2); 1.4301 (A182-F304); 1.4541 (A276-321); 1.4571 (A276-316TI); 1.4404 (A182-F316L); 1.4462 (A182-F51); further materials by request Connection Flanges according to DIN / ANSI* Sealing and connection parts are not scope of supply Mounting position vertical* or horizontal Operating Condition Pressure difference between inlet (DN 1) and Bypass branch (DN 3) Flow rate main direction max. 400 bar max. 5800 psi 140 m³/h up to 900 m³/h* 618 USgpm up to 3965 USgpm* Flow rate bypass up to 250 m³/h* (1100 USgm)* Max. 35% of main flow rate is advised* Flow velocity max. 10 m/s (flange) Pressure loss in the valve 0,8 bar * standard version, more by request 1/5

Design The construction is according to specification AD 2000 and particularly to EN 13445. As per Pressure Equipment Directive 97/23 EC the products are provided with the CE marking and the Declaration of Conformity. Certified according to the Module H1 (Pressure Equipment Directive 97/23 EC) all dangerous material classes of category 1 to 4 are covered. Installation and Connection The Automatic Minimum Flow system is produced and tested only for the ordered data according the customer data sheet. Following points have to be alluded: Mounting direct on the pump discharge branch (advised) Pipes have to be connected free of stress, without offset, mismatch or longitudinal shifting The pipe system must be cleaned and free of soiling Installation has to be in the ordered mounting position To maintain the valve and to calm down the flow a piece of straight pipe with a length of 1 meter (40 ) has to be installed at the bypass branch DN 3 and at the outlet branch DN 2 The bypass pipe has to be filled with medium anytime The supplied installation and operating instructions has to be followed L = 5 x admissible! Right! Figure 2 Mounting with straight pipe piece Q q2 not admissible! False! not admissible! Suction Tank False! Note of Application The operator of these fittings is responsible for suitability, proper use and corrosion resistance of the used materials with regard to the used fluid. It must be ensured that the materials selected for the fitting parts in contact with the medium are suitable for the used process media. The fitting may only be used for the application specified in the operating instructions and the data sheets. Provide a touch guard for surface temperatures of < -10 C or > +50 C. This touch guard must be designed in a way that the max. allowable ambient temperature on the unit is not exceeded. Before replacing the valve, check that the unit is free of hazardous media and pressures. Type Designation of the Valves The designation of the valve specifies the type, nominal width and pressure rate, the flange sizes and the mounting position. Example: S M A 6 3-8 0 / 3 2 0-8 0 / 8 0 / 4 0 / 0-1 S M A 6 3-3 ANSI2500-3 / 3 / 1,5 / 0-1 Valve type for not speed controlled pump 63 for speed controlled pumps 64 Valve size DN 80 mm 80 DN 3 (ANSI) 3 Pressure rate 320 bar 320 2500 lbs. (ANSI) ANSI2500 Flange sizes inlet DN 1 80 mm 80 inlet DN 1 3 (ANSI) 3 outlet DN 2 80 mm 80 outlet DN 2 3 (ANSI) 3 bypass DN 3 40 mm 40 bypass DN 3 1,5 (ANSI) 1,5 additional branch no additional branch 0 mounting (applied to main flow) vertical 1 horizontal 2 2/5 Qmin q1 Handoperating branch q3 SMA 64 for speed controlled pumps The type SMA 64 corresponds technically with the SMA 63 and has to be used for pumps with a speed control device. For using the SMA63 the minimum discharge pressure of the pump has to be at least 70 bar. DN4 Bypass with multistage throttle for speed controlled pumps Q Main Pump Booster Pump Figure 3 Bypass Return with additional hand operated branch (optional)

Marking of the Valve The Automatic-Recirculation-Check Valve has the following name plate with all relevant valve data. Figure 4 Name plate mounted to the fitting Accessories Pressure gauge at the bypass for preventive maintenance of the function and the wear of the Minimum Flow System. The hand operating branch with multiport-throttle is fitted at the casing below the cone seat and serves to pass off the minimum flow via a hand-operated valve combination. We recommend the branch for protection of the internal bypass parts at extreme operating conditions, e.g. at frequent operation in the range of bypass flow as well as for filling and start-up of the plant. Warm-up branch, pressure gauge branch, draining branch etc. can be provided, if required. The pressure device SPD avoids cavitations and flashing in piping. The function corresponds to a variable throttle which adjusts oneself to the flow rate. The damping valve SRV will be applied to absorb pressure shocks during recurrent on/off operation e.g. for descaling facilities at steel mills. The SRV has to be mounted direct to the AR-Valve. Filtering installation to provide filtered medium for the pilot control of the bypass, e.g. for descaling plants. Parts List SMA 63/64 Part-# Designation Materials 1 Lower body 2 Upper body 3 Cone 4 Cone guide 5 Cone guide 11 Bypass body 12 Closing plate 13 Multiport throttle 14 Ring seat 15 Piston 16* Disc 17* Piston guide 18 Spacer ring 19 Disc 30 Valve block 31 Control plunger 32 Lever 33 Connection piece 35 Connection piece 36 Valve needle 37 Adjustment throttle 38 Spacer ring 39 Bearing pinn 40 Connection piece 70.1-4 Impulse pipes 73.1 Pipe coupling 78.1 O-Ring 79.1 Seal ring set 79.2 Seal ring set 79.3 Gasket 90.1 Locking screw 91.1 ff Socket screw 92.1* Hexagonal nut 92.2* Lock washer 95.1 Coil spring 95.3 Coil spring 95.4* Coil spring 98.1 Name plate * for SMA 64 only according to operating conditions and valid standards 3/5

4/5 Figure 5 SMA 63 On/Off-regulated AR with multistage pressure and flow reduction in the bypass

5/5 Figure 6 SMA 64 On/Off-regulated AR for speed controlled pumps with multistage pressure and flow reduction in the bypass