AIRFIX EXPANSION VESSELS. Airfix. Expansion vessels for potable water systems AIRFIX A AIRFIX D AIRFIX D-E. 2007 edition / UK

Similar documents
FLEXCON EXPANSION VESSELS. Flamco FLEXCON Flexcon. Expansion vessels FLEXCON FLEXCON M. Flamco FLEXCON V-B.

Flamco Stainless steel mountings

AIR AND DIRT SEPARATORS. Flamco FLEXVENT. Air and dirt separators FLAMCOVENT FLAMCOVENT CLEAN FLEXAIR FLAMCO CLEAN FLAMCO A-S.

EXPANSION AUTOMATS. Flamco. Compressor and pump expansion automats, pressurisation units FLEXCON M-K FLAMCOMAT ENA.

Flamco. Flexcon M. Installation and operating instructions Flamco

Flamco Diaphragm pressure expansion vessels

SISTO-16TWA/HWA/DLU. Type Series Booklet

PRESSURISATION UNITS EXPANSION VESSELS ELECTRONIC FILLING DEVICE (EFD) MAXI MAXI PLUS EXPANSION VESSELS

Automatic Bypass Control AVDO

Thermostatic actuator RAVV - for 2-way valves RAV-/8 (PN 10), VMT-/8 (PN 10), VMA (PN 16)

MFP14, MFP14S and MFP14SS Automatic Pumps

Thermostatic actuator RAVI - for 2-way valves RAV-/8 (PN 10), VMT-/8 (PN 10), VMA (PN 16) - for 3-way valves KOVM (PN 10), VMV (PN 16)

ITE. Indirect calorifier ITE - 400/500/600/750/1000. Installation, User and Service Manual. Innovation has a name.

2-Port Self-acting Temperature Control Valve Selection for Heating and Cooling Applications

Diaphragm Seal with flush diaphragm and flange acc.to SMS. Completed with pressure gauge in stainless steel, liquid filled or pressure transmitter

Materials : Cast iron body

Piston Accumulators. SK Series. Accumulator Catalog. Piston Types. Description. Sealing Systems. End Cap. O-ring. Sealing System. Piston.

Pilot Operated Pressure Reducing Valve PRV 47 (Steel) PRV47I (St.Steel)

Accumulators, Accessories and Spares

RAPID RESPONSE Model RSV-1 Residential Shut-Off Valve, 1 Inch and 2 Inch (DN25 and DN50) for Dual-Purpose Residential Water Supply General Description

EVAC ONLINEVAC TECHNICAL DATA EVAC ONLINEVAC 16, 24 V DC. Required maintenance space 700 mm. Required maintenance space 200 mm 360 Ø13

Description of functions

Laddomat Charging unit

solarplus solar systems general features

Electric Flow Boiler

Solar Collector Series. Product List

Price List Rev.2. AGUIDROVERT S.L. c/ Cervantes 20, Zaragoza (Spain) Tel.: Fax:

CRN A-F-G-E-HQQE 3x400D 50 HZ

Flow controller with integrated control valve (PN 16, 25, 40*) AFQM, AFQM 6 - return and flow mounting

SUPRApak S Series Filter Housings SUPRApak Filtration For Small Batch Depth Filtration

CSF16 and CSF16T Stainless Steel Steam Filters

Thermostatic actuator RAVK - for 2-way valves RAV-/8 (PN 10), VMT-/8 (PN 10), VMA (PN 16) - for 3-way valves KOVM (PN 10), VMV (PN 16)

Flexcon ASME Tanks. Flexcon Industries Ph: Pond Street Fax:

Thermostatic valve Type AVTA

Self-operated Temperature Regulators Temperature Regulator Type 1u

Duplex Filters 40 FLDK 0008(C)-0120(C)

Seated valves (PN 16) VF 2 2-way valve, flange VF 3 3-way valve, flange

Thermostatic actuator RAVK - for 2-way valves RAV-/8 (PN 10), VMT-/8 (PN 10), VMA (PN 16) - for 3-way valves KOVM (PN 10), VMV (PN 16)

Speedflow Undersink Unvented Water Heater. Models SF10K and SF15K. Instruction Manual

ThermoSorb Desiccant Dryers

CALEFFI. Compact automatic flow rate regulator with polymer cartridge. 127 series 01166/09 GB

PRESSURE REDUCING VALVES

Technical data. Danfoss DHP-A

Range Tribune HE Solar Unvented Direct and Indirect Cylinders

Thermostatic element RAVV for 2-way valves

ecomax Instructions for use Wall hung room sealed fan assisted condensing boilers For the user

PRO-CLEAN. Technical Description. Specifications. Space-saving design with minimum heat loss (melamine resin insulation)

maximise the sun s energy with warmflow solar Warmflow Solar

Questionnaire Pure Media Systems

NIBE ACCESSORIES. NIBE Accessories A NEW GENERATION OF HEAT PUMPS


Installation and User Instructions Unvented Electric Storage Water Heater Models: S10UNV, S15UNV.

Blowdown vessels Meeting the requirements of HSE PM60

Instruction Manual. Alfa Laval SB Membrane Sample Valve ESE02963-EN

Self-operated Pressure Regulators Universal Pressure Reducing Valve Type 41-23

When Safety Comes First. Emergency Safety Shower and Eye Wash Catalogue

save water, save money, save the environment Monsoon domestic rainwater harvesting systems

Confidential. Proportional reducer D386 ATEX. Male base connector View from weld side

Size : Ends : Min Temperature : Max Temperature : Materials : Cast iron body

ECOCIAT. Domestic hot water heat recovery unit

SF15K SF05KSS, SF10KSS

Stainless steel process fittings

VDL 53 - Vacuum drying oven for flammable solvents

MAKING MODERN LIVING POSSIBLE. Thermostatic valve AVTA. Technical brochure

VIESMANN. Datasheet Part numbers and prices: see pricelist VITOSOL 200-F. Flat-plate collector for the utilisation of solar energy

SELECTION, APPLICATION & MAINTENANCE

2CP. Twin-impeller pumps PERFORMANCE RANGE INSTALLATION AND USE APPLICATION LIMITS OPTIONALS AVAILABLE ON REQUEST CONSTRUCTION AND SAFETY STANDARDS

Bypass level indicator With magnetic display Model BNA

Valve systems Base plates, according to standard ISO Brochure

Shut-off & Lockout Valves 1/4" to 1-1/2" port size

FVA/A1 saturated-steam sterilizer

Ergo-Pro Single Line Solar Station Installation and Operating Instructions

BERMAD Waterworks. Pressure Relief/Sustaining Valve. 700 Series. Model 730. Features and Benefits. Major Additional Features

S GATE KNIFE GATE VALVE WITH PNEUMATIC ACTUATOR

ISORIA. Centered disc butterfly valves with AMRING elastomer liner. 240 PSI: 1½ to PSI : 10 to 24

series Materials Body: 1/2, 3/4 and 1 : dezincification resistant alloy brass EN CW617N

When Safety Comes First. Emergency Safety Shower and Eye Wash Catalogue

British Standard Underground Hydrant Range

Butterfly Valves PN 6/10/16 for flanged connection

BROEN UNiFlEx FiTTiNgs FOR BURNiNg gases OEN OEN ifl ifl FOR FOR BURN BURN gas gas

EXPANSION AUTOMATS. Flamco. Flamco. Compressor and pump expansion automats, pressurisation units FLEXCON M-K FLAMCOMAT ENA. Flamco Edition / EXP

INNOVATIVE SOLUTION OF DOMESTIC HEATING SPLIT TYPE SPLIT DHW INTEGRATED TYPE MONOBLOC TYPE

Stove-boiler for solid fuels KW Directions for use and assembling

Vacuum Gate Valve DN 100 and DN 150

Steam Generator Boilers Compact Steam Boilers. Rapid Start-Up Safe in Operation

Hot water supply, distribution and use

SPARE PARTS EXPLODED VIEW GAS WALL BOILERS Model GENUS PREMIUM FS CUENOD. R EN - Edition 01-26/10/2009

Integrated Presetting Valves - for Normal Volume Flows RA-N and for Small Volume Flows RA-U

LK Electric Boiler - 4,5

Integrated Presetting Valves for Normal 013G0372 and Small 013G0373 Volume Flows

Geberit Mapress Catalogue 2008 / Valid from 1 April 2008

BRAZED PLATE INSTALLATION MANUAL

ECOplus Solar Cylinder

Vacuum drying oven for non-flammable solvents

CRN5-5 A-FGJ-G-E-HQQE 3x230/400 50HZ

Automatic control equipment for HVAC systems

Select Radiators Installation Guide

Data Sheet VITOSOL 100. Flat collectors for the utilisation of solar energy. Vitosol 100. Part nos. and prices: see price list

Zenith Solar thermal 4.5m pump station Installation manual

Baumann Flexsleev Sanitary Control Valve

Transcription:

AIRFIX EXPANSION VESSELS 4 Airfix Expansion vessels for potable water systems AIRFIX A AIRFIX D AIRFIX D-E 2007 edition / UK

Flamco offers you a wide choice of expansion vessels for potable water Airfix are specially constructed incorporating a flow through design that regularly rinses the vessel with fresh mains water. By specifying Airfix you can be assured of clean water. AIRFIX A The Airfix A expansion vessel enlarged here is supplied with a flow divider. This flow divider can be fitted between a T-piece and the Airfix A vessel (T-piece not supplied with the vessel). The Airfix A expansion vessel and T-piece can be fitted in the cold-water system of the boiler and flow through is established. USER ADVANTAGES AIRFIX A Very easy to fit. Covered inside and out with an anti-corrosion coating. The water is not contaminated by the material of construction and has been CE and WRAS approved. Can be used with any storage water heater or pressure boosting system. 4.2

AIRFIX D AIRFIX D-E AIRFIX D-E-B Airfix D-E Pressure expansion vessels with exchangeable diaphragms, suitable for use in hot-water, water-booster and watermanagement systems. The Airfix D-E is a floor standing and easy to install unit. Featuring a flow-through vessel with two flange connections which has an exchangeable butyl diaphragm. Airfix D-E vessels are fitted as standard with an electronic diaphragm-rupture sensor. USER ADVANTAGES AIRFIX D-E Complete flow-through from the vessel, with a choice of flow direction. Low pressure loss. The diaphragm-rupture sensor can be configured for remote reading. Simple installation and long service life. The Airfix D-E diaphragms come with a WRAS certificate. With the flow-through design they are the best choice. Ensure that the double system connection is directly connected with the main flow in the drinking water installation. 4.3

Airfix technology offers the user significant On unvented potable applications an expansion vessel is required to take up thermal expansion. Only Airfix can offer partial (Airfix A) or full flow through designs (Airfix D) that guarantee no stagnant water in your installation. AIRFIX D Airfix A and Airfix D vessels are white in colour. Both diaphragm and vessel coating are internationally approved for use in combination with drinking water, meeting the CE standards (2002/16/EC) and WRAS approved. The unique clench ring design damages neither the diaphragm nor the two halves of the vessel. Airfix D vessels use a special T-piece (supplied) which directs water flow through with its internal divider to ensure full flow-through in the vessel. AirfixControl (not supplied) optional. The vessel pre-charge must be 0.2 bar lower than the pressure on the downstream side of the pressure-reducing valve. Directions on how to fit the Airfix pressure expansion vessel Airfix A or Airfix D expansion vessels should always be used as part of a standard system component kit. Airfix A or D 4.4

advantages The Airfix D-E expansion vessel can be used in pressure boosting systems, on either the intake or compression sides of the pumps. These installations are intended to overcome excessively low supply pressure and help prevent excessive pressure changes at low flow speeds. The Airfix D-E expansion vessel can be used on water storage systems. AIRFIX D-E Inspection port (from 600 litres). Pressure gauge with self-sealing valve case. Diaphragm-rupture sensor display with red LED. Maximum permissible gas pre-charge on delivery: 6 bar. Maximum working pressures 10 and 16 bar. Expanzní nádoby Airfix D-E jsou potažené zelenou barvou. Airfix P potable expansion vessels for use on domestic and commercial hot water systems. WRAS approved and covered by the CE mark for design safety on pressure equipment. Suitable for unvented hot water, pressure boosting, sealed heating and chilled systems, suitable for glycol (anti-freeze) concentrations of 50% by volume (non potable systems). Maximum working pressure typically 10 bar(g), conforming to the Pressure Equipment Directive 97/23/EC and WRAS approved up to 500 litres. Airfix P Airfix D-E-B For pressure boosting, drinking water, processing or fireextinguishing installations. Single steel threaded connection (without flow-through function). Airfix D-E Double system connection. The contoured design allows for greater strength at the supported ends of the diaphragm, providing an extended life and highly efficient vessel. The pre-charge is nitrogen gas and is used for its low permeability across the EPDM diaphragm. 4.5

Airfix A and Airfix D expansion vessels The maximum temperature in Airfix A and D vessels is 70 C. WRAS approved. Versions and dimensions Airfix A Type Gas charge Capacity Max. operating pressure Connection (male thread) Dimensions in mm Weight Code number in bar in litres in bar D Ø A H in kg Airfix A 8 4 8 10 3 /4 245 301 4.4 FCAF 008 Airfix A 12 4 12 10 3 /4 286 334 5.8 FCAF 012 Airfix A 18 4 18 10 3 /4 328 325 6.7 FCAF 018 Airfix A 25 4 25 10 3 /4 358 378 8.9 FCAF 025 Airfix A 35 4 35 10 3 /4 396 437 11.1 FCAF 035 Versions and dimensions Airfix D Type Gas charge Capacity Max. operating pressure Connection (male thread) Dimensions in mm Weight Code number in bar in litres in bar D Ø A H in kg Airfix A 8 4 8 10 3 /4 245 301 4.4 FCAF D 008 Airfix A 12 4 12 10 3 /4 286 334 5.8 FCAF D 012 Airfix A 18 4 18 10 3 /4 328 325 6.7 FCAF D 018 Airfix A 25 4 25 10 3 /4 358 378 8.9 FCAF D 025 Airfix A 35 4 35 10 3 /4 396 437 11.1 FCAF D 035 4.6

Airfix D-E, D-E-B and Airfix P expansion vessels Airfix D-E and D-E-B vessels from 50 3000 litres with a maximum operating pressure of 10 or 16 bars and a maximum operating temperature of 70 C. Vessels with model approval in compliance with pressure equipment directive 97/23/EC. Diaphragm-rupture sensor, Directive 89/336/EC-compliant. Stainless steel flow-through flange or single point connection available on request. When sizing these vessels, the vessel efficiency must not exceed 60%. 10 bar WRAS approved. Airfix P vessels with a maximum operating pressure of 8 or 10 bar and a maximum operating temperature of 100 C. Versions and dimensions Airfix D-E Type Capacity Dimensions in mm Flanges Weight in kg Code number in litres Ø D H a e Ø d PN 16 10 bar 16 bar 10 bar 16 bar Airfix D-E 50 50 450 836 320 190 470 DN 40 60 70 FCAF DE 050 FCAF DE 050S Airfix D-E 80 80 450 1016 320 190 470 DN 40 70 80 FCAF DE 080 FCAF DE 080S Airfix D-E 120 120 450 1271 320 190 470 DN 40 80 95 FCAF DE 120 FCAF DE 120S Airfix D-E 180 180 550 1227 320 185 535 DN 40 110 135 FCAF DE 180 FCAF DE 180S Airfix D-E 240 240 550 1487 320 185 535 DN 40 130 160 FCAF DE 240 FCAF DE 240S Airfix D-E 300 300 550 1827 320 185 535 DN 40 150 190 FCAF DE 300 FCAF DE 300S Airfix D-E 600 600 750 1840 390 140 680 DN 50 230 300 FCAF DE 600 FCAF DE 600S Airfix D-E 800 800 750 2230 390 140 680 DN 50 270 350 FCAF DE 800 FCAF DE 800S Airfix D-E 1000 1000 750 2730 390 140 680 DN 50 320 415 FCAF DE 1000 FCAF DE 1000S Airfix D-E 1600 1600 1000 2663 370 260 690 DN 80 550 610 FCAF DE 1600 FCAF DE 1600S Airfix D-E 2000 2000 1200 2412 370 280 840 DN 80 620 680 FCAF DE 2000 FCAF DE 2000S Airfix D-E 3000 3000 1200 3312 370 280 840 DN 80 805 890 FCAF DE 3000 FCAF DE 3000S Versions and dimensions Airfix D-E-B Type Capacity Dimensions in mm Female-thread Weight in kg Code number in connection litres Ø D H a Ø d ISO 228/1 10 bar 16 bar 10 bar 16 bar Airfix D-E-B 50 50 450 836 300 470 G 1 1 /2 60 70 FCAF DEB 50 10B FCAF DEB 50 16B Airfix D-E-B 80 80 450 1016 300 470 G 1 1 /2 70 80 FCAF DEB 80 10B FCAF DEB 80 16B Airfix D-E-B 120 120 450 1271 300 470 G 1 1 /2 80 95 FCAF DEB 120 10B FCAF DEB 120 16B Airfix D-E-B 180 180 550 1227 300 535 G 1 1 /2 110 135 FCAF DEB 180 10B FCAF DEB 180 16B Airfix D-E-B 240 240 550 1487 300 535 G 1 1 /2 130 160 FCAF DEB 240 10B FCAF DEB 240 16B Airfix D-E-B 300 300 550 1827 300 535 G 1 1 /2 150 190 FCAF DEB 300 10B FCAF DEB 300 16B Airfix D-E-B 600 600 750 1840 280 680 G 2 230 300 FCAF DEB 600 10B FCAF DEB 600 16B Airfix D-E-B 800 800 750 2230 280 680 G 2 270 350 FCAF DEB 800 10B FCAF DEB 800 16B Airfix D-E-B 1000 1000 750 2730 280 680 G 2 320 415 FCAF DEB 1000 10B FCAF DEB 1000 16B Airfix D-E-B 1600 1600 1000 2663 390 690 G 2 1 /2 550 610 FCAF DEB1600 10B FCAF DEB 1600 16B Airfix D-E-B 2000 2000 1200 2412 390 840 G 2 1 /2 620 680 FCAF DEB2000 10B FCAF DEB 2000 16B Airfix D-E-B 3000 3000 1200 3312 390 840 G 2 1 /2 805 890 FCAF DEB 3000 10B FCAF DEB 3000 16B Versions and dimensions Airfix P Type Capacity in Dimensions in mm Connection Weight in kg Code number litres Ø D H Airfix P 2 2 120 235 1 2 M 1.0 24850 Airfix P 3 3 170 240 3 4 M 1.3 24851 Airfix P 5 5 170 275 3 4 M 1.4 24852 Airfix P 8 8 220 305 3 4 M 1.8 24853 Airfix P 12 12 260 310 3 4 M 2.4 24854 Airfix P 16 16 260 345 3 4 M 3.0 24855 Airfix P 18 18 260 375 3 4 M 3.2 24856 Airfix P 24 24 260 485 3 4-1 M 3.6 24857 Airfix P 35 35 380 470 1 M 5.8 24858 Airfix P 50 50 380 720 1 M 8.4 24859 Airfix P 60 60 380 830 1 M 10.7 24860 Airfix P 80 80 460 760 1 M 12.2 24861 Airfix P 100 100 460 880 1 M 13.5 24862 Airfix P 150 150 510 1030 1 M 23.4 24863 Airfix P 200 200 590 1070 1 1 4 M 33.0 24864 Airfix P 300 300 650 1250 1 1 4 M 44.5 24865 Airfix P 500 500 750 1600 1 1 4 M 58.5 24866 Airfix P 750 750 800 1820 2 F 153.5 24867 Airfix P 1000 1000 800 2130 2 1 2 F 183.5 24868 4.7

AIRFIX EXPANSION VESSELS AIRFIX A CONTENTS PAGE Advantages of Airfix vessels 4.2/4.3 Airfix technology means the best in flow-through 4.4/4.5 Tables and technical data 4.6/4.7 Flamco UK Limited Unit 4, St. Michael s Road Lea Green Industrial Estate St. Helens, Merseyside WA9 4WZ Tel.: +44 (0) 1744 818100 Fax: +44 (0) 1744 830400 info@flamco.co.uk www.flamco.co.uk AIRFIX D There is more information on the CD that accompanies this brochure. AIRFIX D-E Copyright Flamco UK Limited. No part of this publication may be reproduced or published in any way without explicit mention of the source. The data listed are solely applicable to Flamco products. Flamco UK Limited shall accept no liability whatsoever for incorrect use, application or interpretation of the technical information. Flamco UK Limited reserves the right to make technical alterations Flamco UK Limited conditions of sale apply. 18502655