Classification report No. 2013-2175-K1-1

Similar documents
Test report No

BS 476: Part 7: Method For Classification Of The Surface Spread Of Flame Of Products. A Report To: Eco-Sol Ltd. Document Reference:

CLASSIFICATION OF REACTION TO FIRE PERFORMANCE IN ACCORDANCE WITH EN :2007+A1:2009

BS 476: Part 7: Method For Classification Of The Surface Spread Of Flame Of Products. A Report To: Gurit (UK) Ltd. Document Reference:

CLASSIFICATION OF REACTION TO FIRE PERFORMANCE IN ACCORDANCE WITH EN : 2007

CLASSIFICATION OF REACTION TO FIRE PERFORMANCE IN ACCORDANCE WITH EN :2007

CLASSIFICATION OF REACTION TO FIRE PERFORMANCE IN ACCORDANCE WITH EN :2007+A1:2009

CLASSIFICATION OF REACTION TO FIRE IN ACCORDANCE WITH EN :2007

Introduction. Facade Fire Test on PUR External Thermal Insulation Composite System (ETICS)

CERTIFICATE OF APPROVAL No ME 5078

pinta ACOUSTIC PANEL [1/7]

Classification of reaction to fire of glass products Recommendation from Glass for Europe

Test Report: ICL/H11/979. BS 7837: 1996 Flammability performance for textiles used in the construction of marquees and similar textile structures.

fr fire retardant MARMOLEUM

BRE Global Test Report

Out - Ecrano / White Charcoal

EN Export Manager Pulastic Sports Surfaces The Netherlands

FIRE BEHAVIOR CERTIFICATION OF THERMAL INSULATION MATERIALS

Test report P 7013-E. InoPaz H2O. Pazkar LTD. Alon Tavor Industrial Zone AFULA / Israel. J. Magner Dipl.-Ing. N. Machill.

MRK/ Page 1(9) 2 Description and assessment of the Production process. 3 Description and assessment of the Surface Treatment Methods

furnishings flammability characteristics

REACTION TO FIRE CLASSIFICATION REPORT No. RA ACCORDING TO THE EUROPEAN STANDARD NF EN A1:2013

Dubai Municipality Standard DMS 1: Part 5: 2004

CONE CALORIMETER A TOOL FOR MEASURING HEAT RELEASE RATE

How To Test For Premer Retardant

SURFACE PREPARATION STANDARDS

TIGER Drylac U.S.A., Inc Swenson Avenue St Charles, IL T F office.us@tiger-coatings.us

Out - Serge 600 / White Yellow

Naue GmbH&Co.KG. Quality Control and. Quality Assurance. Manual. For Geomembranes

CERTIFICATE NAME OF PRODUCT MANUFACTURER PRODUCT DESCRIPTION CERTIFICATION PROCEDURE. No VTT C Date of issue , Updated July 1, 2011

Sikagard -203 W (Steridex)

National Technical Test Certificate (Allgemeines bauaufsichtliches Prüfzeugnis - AbP)

SPREFIX SPRAY INSULATION _ in the marine market.

Approved. Property Test/Standard Description. gloss (70-85) Flash point ISO 3679 Method 1 30 C calculated VOC-US/Hong Kong. US EPA method 24 (tested)

: ARLIN - TEXTILE WALLCOVERING

EUROPEAN STANDARDS PERSONAL PROTECTIVE CLOTHING FOR FLAME RESISTANT. Alexander Gstettner, Lenzing AG Austria

Fire testing for BCA compliance

Understanding BS EN 771-3: Aggregate concrete masonry units

Annex of the certificate (Page 1/6) Accreditation Scope

REACTION TO FIRE CLASSIFICATION REPORT No. RA ACCORDING TO THE EUROPEAN STANDARD NF EN

EXPANDED POLYSTYRENE (EPS) INSULATION BOARD SPECIFICATIONS

PRODUCT DESCRIPTION 29/08/2014

PRODUCT DATA SHEET Sika Cable System

Approved. Property Test/Standard Description. matt (0-35) Flash point ISO 3679 Method 1 27 C calculated IED (2010/75/EU) (calculated)

Requirements for Fire Protection of Light Weight Floor Systems **Act 1 Revisited**

UNLIMITED VARIETY OF CREATIVE SHEET MATERIAL.

Fire Retardant Cladding

Guide Specification STAYFLEX CORROSION CONTROL AND THERMAL INSULATION SYSTEM

Technical Data Sheet. Plasterboard MSZ EN 520

18 June 2001 GUIDELINES ON FIRE TEST PROCEDURES FOR ACCEPTANCE OF FIRE-RETARDANT MATERIALS FOR THE CONSTRUCTION OF LIFEBOATS

Hexavalent Chrome Removal in Aircraft Painting Schemes

FDM Material Properties

Fire-resistant barriers: background on requirements and determination method. Reading guide for test reports.

EVALUATION ACCORDING TO ASTM F

SIGMAFAST 210. PRODUCT DATA SHEET December 12, 2014 (Revision of April 1, 2013) DESCRIPTION

BETON. CONCRETE EFFECT IMITATION CONCRETE FOR A PURE AND MODERN EFFECT Application instructions primer - base - finish

Squash Court Design general points

Report Number BTC 17755F

European technical approval

Fire Preventive and Fireproof Performance Test and Evaluation Procedure Manual

Data sheets Material characteristics 1.2/1

Loss Prevention Standard

A new approach to the Danish guidelines for fire protection of combustible insulation

1-085 Fire safety performance of materials

Mold Preventing I nterior System

Fire Testing of Recycled Materials for Building Applications

Power chip resistor size 2512 PRC221 5%; 2% FEATURES Reduced size of final equipment Low assembly costs Higher component and equipment reliability.

Material data sheet. EOS MaragingSteel MS1. Description

Fire 2This Technical Bulletin has been commissioned by the UK SIP Association in

ASTM E 90: Laboratory Measurement of Airborne Sound Transmission of Building Partitions and Elements

Elastic, 1-part-polyurethane, liquid waterproofing membrane

Approved. Property Test/Standard Description. matt (0-35) Flash point ISO 3679 Method 1 28 C calculated VOC-US/Hong Kong. US EPA method 24 (tested)

Properties of printing papers: Specifications, basic requirements for data generation and control of the printing process

Composite Panel Firewall Systems

MARTIN TESTING LABORATORIES (MTL) PAINTS AND COATINGS TESTING CAPABILITIES

Prefabricated building PVC vertical sliding window

This test may be carried out with the IGT printability testers A1-3, A2-3 and AIC2-5 with the accompanying inking unit AE.

RESTORATION + DECORATION OF BALCONIES AND TERRACES. Decorative, Easy to Maintain and Slip-Resistant Surfaces

Global Hybrid Roofing Solutions (Delaware) LLC

Construction. 3-part thixotropic epoxy patching mortar. Product Description. Tests

temperature needed to reach the sintering necessary to make the product frost-proof, non-absorbing and resistant to chemical attacks.

WATERPROOFING OF WET ROOMS

09990 MOLD REMEDIATION, LEAD-BASED PAINT ABATEMENT AND ENCASEMENT OF ASBESTOS

Physically Crosslinked Foam Insulation

Customer Services - 5, rue René Panhard LE MANS Cédex 2 FRANCE Tel.: (+33) p.ball@colart.fr

HFM Heat Flow Meter Thermal Conductivity Analyzer

Loss Prevention Standard

A NEW GENERATION OF FLAME RETARDED POLYAMIDES BASED ON PHOSPHINATES

Authorised and notified according to Article 10 of the Council Directive 89/106/EEC of 21 December 1988 on the

Material data sheet. EOS StainlessSteel GP1 for EOSINT M 270. Description, application

RAW INSTALLATION GUIDE

Flame Spread Performance of Wood Products

This document is a preview generated by EVS

Product Data Sheet PDS050: ArmourFX polished plaster and decorative paint panels

Steel radiators Quality assessment RAL-GZ 618

Tecnoepo Flooring System 185

LE MARAIS Series White Body Wall Tiles

TI 15/20: Selection criteria for conformal coatings and casting compounds used for LED protection

MILMAN & ASSOCIATES STRUCTURAL CONSULTING ENGINEERS/ PROJECT MANAGERS

Transcription:

Exova Warringtonfire, Frankfurt Industriepark Höchst, C369 Frankfurt am Main D-65926 Germany T : +49 (0) 69 305 3476 F : +49 (0) 69 305 17071 E : EBH@exova.com W: www.exova.com Classification report No. 2013-2175-K1-1 issued 04.09.2013 Applicant: Remmers Baustofftechnik GmbH Bernhard-Remmers-Str. 13 49624 Löningen Order: Classification of the burning behaviour according to DIN EN 13501-1 (2010-01) Date of order 24.05. + 28.08.2013 Notification number of the test laboratory NB 1378 Designation of the classificated building product Products designated as PUR FG-201 Filling Primer" "PUR SL-210 Finish" "PUR HL-211 / 90 High Gloss" This classification report lays down the classification of the building product above according to the procedures of DIN EN 13501-1. The classification report are only allowed to be published or reproduced, not changed in form and tenor without permission of the Exova Warringtonfire, Frankfurt The abridged account of a classification report is only allowed with the agreement of the Exova Warringtonfire, Frankfurt. This classification report is a translation of the German version 2013-2175-K1 (issued 04.09.2013). In case of doubt only the German version is valid. This classification report contains 5 pages. Registered Office: Exova GmbH, Industriepark Höchst, C369, Frankfurt, D-65926, Registered Company No. HRB 83049 Ust-Id Nr. DE259957713

Classification report No. 2013-2175-K1-1 issued 04.09.2013 page 2 of 5 1. Description of the material 1.1 Details of the customer: Products designated as Trade name: PUR FG-201 Filling Primer" "PUR SL-210 Finish" "PUR HL-211 / 90 High Gloss" PUR FG-201 Filling Primer, MV=10:1 PUR H-280-hardener PUR SL-210/10 Finish matt blunt, MV=10:1 PUR H-280-hardener PUR SL-210/50 Finish silk gloss, MV=10:1 PUR H-280-hardener PUR SL-211/90 High Gloss; MV=4:1 PUR H-280-hardener Sample material: coating Type of material: acrylic resin coating Method of production: Coated Total square weight: see coating log Colour: colourless Flame retardants: Manufacturer: Lanxess Type flame retardant: Phosphate Content flame retardants: 1.50% For composite (e.g. layered materials): Type of surface: coating Used substrate: Topan MDF FF FR, Glunz AG, class B-s2, do DIN EN 13501-1 raw density: 802,12 kg / m³, 19.2 mm thick Intended end use: Coating of wood-based materials Coating log: Nr. Lacquers / raw materials PUR FG-201Filling Primer (MV=10:1 PUR H-280- hardener) PUR SL-210/10 Finish matt blunt (MV=10:1 PUR H- 280_hardenerr) PUR SL-210/50 Finish silk gloss PUR SL-211/90 High Gloss (MV=4:1 PUR H-280- hardener) matt - gloss clear lacquer P1951-1 P1951-2 P1951-3 P1951-2 P1951-2 colourless colourless colourless colourless colourless 1x 200 g/m² 2x120ml/m² = 2x115g/m² 2x120ml/m² = 2x115g/m²

Classification report No. 2013-2175-K1-1 issued 04.09.2013 page 3 of 5 1.2 At the specimen preparation from the Exova Warringtonfire determined values: Painting on wood material, thickness: 19 mm (front surface and edges painted) sample No. material article colour total thickness total square weight 1 coating P1951-1 colourless 19 mm 14,7 kg/m² 2 coating P1951-2 colourless 19 mm 14,6 kg/m² 3 coating P1951-3 colourless 19 mm 15,0 kg/m² 4 coating P1951-2 colourless 19 mm 14,5 kg/m² 5 coating P1951-2 colourless 19 mm 14,6 kg/m² Test arrangement: Lacquered surface to the burner Material construction and fixing see fotos: picture: edge of the large sample wing fixing of specimen 1.3 Production and pretreatment of the samples for the tests according to DIN EN 13823 The samples were provided and delivered for the tests in the necessary sample dimensions, by the manufacturer. The test was conducted fully without joint. The test was conducted without a gap to the plasterboard substrate in accordance with DIN EN 13823, Point 4.4.10 (calcium silicate, gross density 800 ± 150 kg/m³, thickness 12 ± 3 mm). The samples were conditioned for more then 48 h to constant mass at a temperature of 23 ± 2 C and a relative humidity of 50 ± 5% prior to the testing. 1.4 Production and pretreatment of the samples for the tests according to DIN EN 11925-2 The samples were provided and delivered for the tests in the necessary sample dimensions, by the manufacturer. The samples were conditioned for more then 48 h to constant mass at a temperature of 23 ± 2 C and a relative humidity of 50 ± 5% prior to the testing.

Classification report No. 2013-2175-K1-1 issued 04.09.2013 page 4 of 5 2. Test reports and test results 2.1 Test reports Name of test laboratory Customer Report to form the basis Test procedure DIN EN 13823 (SBI) Exova Warringtonfire, Frankfurt Remmers Baustofftechnik GmbH 2013-2175 EN ISO 11925-2 (30s ignition time and edge surface ignition) 2.2 Test results Test results Test procedures Parameter / classes average DIN EN 13823 (SBI) DIN EN ISO 30s 11925-2 15s FIGRA 0,2MJ 120 [W/s] for class A2 FIGRA 0,2MJ 120 [W/s] for class B 175,25 FIGRA 0,4MJ 250 [W/s] for class C FIGRA 0,4MJ 750 [W/s] for class D 168,90 THR 600s [MJ] 7,5 MJ for class A2 THR 600s [MJ] 7,5 MJ for class B 3,91 THR 600s [MJ] 15 MJ for class C THR 600s [MJ] no requirement for class D SMOGRA-index 30 [m²/s²] für s1 SMOGRA-index 180 [m²/s²] für s2 5,88 TSP 600s 50 [m²] for s1 TSP 600s 200 [m²] for s2 55,18 LFS < edge of the specimen for class A2 LFS < edge of the specimen for class B LFS < edge of the specimen for class C no burning dripping off/dropping within 600s for class d0 FS 150 mm within 60 s for class B, C u. D FS 150 mm within 20 s for class E Explanations of table standing too above: Figra 02MJ: Heat release rate with consideration of the THR of threshold value of 0,2MJ [W/s] Figra 04MJ: Heat release rate with consideration of the THR of threshold value of 0,4MJ[W/s] THR 600s: Total Heat Release during 600s [MJ] SMOGRA: Smoke development rate TSP 600s: Total Smoke Production 600s [m²] LFS: Lateral Flame Spread

Classification report No. 2013-2175-K1-1 issued 04.09.2013 page 5 of 5 3 Classification and range of application 3.1 Reference The classification was carried out according to the chapter 11 of DIN EN 13501-1 3.2 Classification The tested material is ranked into the class C related to its behaviour in case of fire Concerning the smoke development the tested material is ranked into the class s2 Concerning the dripping off behaviour the tested material is ranked into the class d0. The classification of the tested material reads therefore: C s2 d0 3.3 Area of application The classification is only valid for the coatings described in chapter one, in the tested gloss levels, on the wood material FF FR Topan MDF, company Glunz AG, Class B-s2, do according to DIN EN 13501-1 (raw density: 802,12 kg / m³, 19.2 mm thick). According to the experience of the test laboratory are in the classification even in between gloss levels included. 4 Reservation This classification report replaces not a possible required type admittance or type certification of the product. This classification report replaces the English translation of the classification report 2013-2175-K1 issued 17.03.2014 (date of signature), which is invalid from now on. Frankfurt 26 th March 2014 P. Scheinkönig Dipl.-Ing. T. Zachäus Tester in charge Laboratory Supervisor