Test report No. 2016-1400

Similar documents
Test report No

BS 476: Part 7: Method For Classification Of The Surface Spread Of Flame Of Products. A Report To: Gurit (UK) Ltd. Document Reference:

BS 476: Part 7: Method For Classification Of The Surface Spread Of Flame Of Products. A Report To: Eco-Sol Ltd. Document Reference:

CERTIFICATE OF APPROVAL No ME 5078

fr fire retardant MARMOLEUM

Introduction. Facade Fire Test on PUR External Thermal Insulation Composite System (ETICS)

Test Report: ICL/H11/979. BS 7837: 1996 Flammability performance for textiles used in the construction of marquees and similar textile structures.

Out - Ecrano / White Charcoal

EVALUATION ACCORDING TO ASTM F

How To Test For Premer Retardant

Out - Serge 600 / White Yellow

Technical Data Sheet. Plasterboard MSZ EN 520

CLASSIFICATION OF REACTION TO FIRE PERFORMANCE IN ACCORDANCE WITH EN :2007+A1:2009

TECHNICAL BULLETIN

Fire Testing of Recycled Materials for Building Applications

BRE Global Test Report

CLASSIFICATION OF REACTION TO FIRE IN ACCORDANCE WITH EN :2007

furnishings flammability characteristics

Test report P 7013-E. InoPaz H2O. Pazkar LTD. Alon Tavor Industrial Zone AFULA / Israel. J. Magner Dipl.-Ing. N. Machill.

CLASSIFICATION OF REACTION TO FIRE PERFORMANCE IN ACCORDANCE WITH EN :2007+A1:2009

DECLARATION OF PERFORMANCE NO. HU-DOP_TN _001

DECLARATION OF PERFORMANCE NO. HU-DOP_TD-25_001

Safety Data Sheet Aluminium profiles Apply for alloys Sapa EN AW 6060, 6063, 6005, 6005A, 6082, yellow chromated, with or without powder coating.

Flying imposes considerable physiological demand

Data sheets Material characteristics 1.2/1

CLASSIFICATION OF REACTION TO FIRE PERFORMANCE IN ACCORDANCE WITH EN :2007

Flammability testing is arguably one of the most important testing procedures within the textile industry

Certification of Plastic Materials

Recommendations Regarding the Handling of Norit GL 50 in Flue Gas Clean up Systems

Safety Data Sheet according to (EG)1907/2006

EUROPEAN STANDARDS PERSONAL PROTECTIVE CLOTHING FOR FLAME RESISTANT. Alexander Gstettner, Lenzing AG Austria

TIGER Drylac U.S.A., Inc Swenson Avenue St Charles, IL T F office.us@tiger-coatings.us

UNLIMITED VARIETY OF CREATIVE SHEET MATERIAL.


OWAplan1. The seamless acoustic ceiling. Pure acoustics. Pure design.

>

EXPANDED POLYSTYRENE (EPS) INSULATION BOARD SPECIFICATIONS

Technical Information DF30

Likely performance of Breezway aluminium framed glass window assembly incorporating alternative steel mesh screens

Quality Assurance Agreement with Production Material Suppliers. History of revisions

Pipe Clamps and Accessories

18 June 2001 GUIDELINES ON FIRE TEST PROCEDURES FOR ACCEPTANCE OF FIRE-RETARDANT MATERIALS FOR THE CONSTRUCTION OF LIFEBOATS

EN Export Manager Pulastic Sports Surfaces The Netherlands

Requirements for Fire Protection of Light Weight Floor Systems **Act 1 Revisited**

CLASSIFICATION OF REACTION TO FIRE PERFORMANCE IN ACCORDANCE WITH EN : 2007

Additional Requirements

Classification of reaction to fire of glass products Recommendation from Glass for Europe

COMMERCIAL ITEM DESCRIPTION PACKAGING MATERIAL, SHEET

Guide Specification STAYFLEX CORROSION CONTROL AND THERMAL INSULATION SYSTEM

E-newsletter 1 st edition, December 09

Fire Retardant Cladding

Control and Indicating Equipment

A NEW GENERATION OF FLAME RETARDED POLYAMIDES BASED ON PHOSPHINATES

The Quality Connection. BETAflam Fire Resistant Safety Cables

Flameproof Audible Signal 115 db (A) Series YA90

National Technical Test Certificate (Allgemeines bauaufsichtliches Prüfzeugnis - AbP)

1.5. UL flammability ratings. *Nylon 6.6 = Polyamide 6.6 is Halogen-free and Silicone-free.

Loss Prevention Standard

A new approach to the Danish guidelines for fire protection of combustible insulation

St. John s University Fire Safety Plan

Report Test Report

Guardian Fire Safety Solutions FIRE RISK CONTROL IN WELDING FUME EXTRACTION SYSTEMS

SCHOTT PYRANOVA Planline System

5SV Residual Current Protective Devices

Rules for Classification and Construction Additional Rules and Guidelines 3 Machinery Installations

Initial Type Testing Report

SVR 12/24V and SVR Akku 12V Installation instructions

Dubai Municipality Standard DMS 1: Part 5: 2004

High Pressure Water Mist Systems: Alternative Solution For Critical Civil Applications

Nightwear Advisory Note

pinta ACOUSTIC PANEL [1/7]

BRÖCKSKES D-VIERSEN PV1-F 4,0 mm BRÖCKSKES D-VIERSEN PV1-F 4,0 mm d d 2 2 C VDE-REG.-Nr /2009

Solutions for nuclear technology

SPORT TABLE TENNIS -ENG-

THERMAL INSULATION MATERIALS TEST METHOD SELECTION LIST

VdS en. VdS Guidelines for water extinguishing systems. Non-return valves. Requirements and test methods. VdS en : (01)

Fire-resistant barriers: background on requirements and determination method. Reading guide for test reports.

Safety Data Sheet according to 1907/2006/EC, Article 31 Printing date: Revision:

screens that fit you COLLECTION

Polyurea Coatings in Secondary Containment with National Technical Approval. Jürgen Magner Kiwa Polymer Institut Flörsheim / Germany

LOW COST PREFABRICATED CONSTRUCTION SYSTEM

fulfils all requirements for medium protection of the criteria catalogue The appendix is part of the certificate and consists of 4 pages.

European technical approval

SURFACE PREPARATION STANDARDS

EUROPEAN STANDARDS AND MARKINGS FOR HAND AND ARM PROTECTION

Optimal 5zon. Product information - Optimal 5zon 06/11/13. Pressure redistributing foam mattress. Clinical and performance information

Fire Life Safety ORC Review Guidelines for PPD Experimental Installations

COMMERCIAL ITEM DESCRIPTION CUSHIONING MATERIAL, PACKAGING, CLOSED CELL FOAM PLANK

1-085 Fire safety performance of materials

HFM Heat Flow Meter Thermal Conductivity Analyzer

Development of Seismic-induced Fire Risk Assessment Method for a Building

Paint Test Equipment. Holitech DC Holiday Tester Data Sheet

Prefabricated building PVC vertical sliding window

VdS Guidelines for the Certification of quality management systems

Description of mechanical properties

Colorcoat Technical Paper Fire performance of pre-finished steel cladding systems

Transcription:

Exova Warringtonfire, Frankfurt Industriepark Höchst, C369 Frankfurt am Main D-65926 Germany T : +49 (0) 69 305 3476 F : +49 (0) 69 305 17071 E : EBH@exova.com W: www.exova.com Test report No. 2016-1400 issued 18.05.2016 Applicant: Vescom B.V. Sint Jozefstraat 20 5753 AV Deurne Date of order: 29.04.2016 Date of sampling: no official sampling of the specimen by a representative of Exova Warringtonfire, Frankfurt Date of arrival: 02.05.2016 Date of test: 18.05.2016 Order: Testing of the ignitability according to DIN EN 1021-1 and -2 (October 2014) With assessment according to DIN 66084 Description / designation of the test object Sample material designated as: Qualität Namal, Dess. 7043 (100% PES FR) Description of the relevant test procedure DIN EN 1021 1 (October 2014) DIN EN 1021 2 (October 2014) DIN 66084 Registered Office: Exova GmbH, Industriepark Höchst, C369, Frankfurt, D-65926, Registered Company No. HRB 83049 Ust-Id Nr. DE259957713

Test report no. 2016-1400 issued 18.05.2016 page 2 of 6 1. Description of the test material 1.1 Details of the customer: Sample material designated as: Qualität Namal, Dess. 7043 (100% PES FR) Quality Namal, Dess. 7043 (100% PES FR) Weight 360 g/m² 1.2 By Exova Warringtonfire, Frankfurt determined values: Fabric Construction: Colour: Square weight: Test foam: red 357 g/m² grey MA3032D, Fa. Metzeler, 30kg/m³ Before the test, the samples were conditioned at 23 C and 50% humidity.

Test report no. 2016-1400 issued 18.05.2016 page 3 of 6 2. Test results Testing of the burning behavior according to DIN EN 1021-1 (ignition source: cigarette) Specimen no. 1 2 Smoldering criteria: Unsafe escalating combustion no no Test assembly consumed no no Smolder to extremities no no smolder through thickness no no smolder more than one hour no no More than 100mm from source no no Flaming criteria: Unsafe escalating combustion no no Test assembly consumed no no Flames to extremities no no Flames through thickness no no Flames > 120 seconds no no Enter "yes" if criteria exceeded or "no" if criteria not exceeded Remarks: The cigarette 1 burn out after 18:25 (min.:sec.) The cigarette 2 burn out after 18:30 (min.:sec.) Test result:

Test report no. 2016-1400 issued 18.05.2016 page 4 of 6 Testing the burning behavior according to DIN EN 1021-2 (ignition source: gas flame) specimen no. 1 2 3 Smoldering criteria: Unsafe escalating combustion no no no Test assembly consumed no no no smolder to extremities no no no smolder through thickness no no no smolder more than one hour no no no More than 100mm from source no no no Flaming criteria: Unsafe escalating combustion no no no Test assembly consumed no no no Flames to extremities no no no Flames through thickness no no no Flames > 120 seconds no no no Enter "yes" if criteria exceeded or "no" if criteria not exceeded Remarks: none Test result:

Test report no. 2016-1400 issued 18.05.2016 page 5 of 6 3. Appearance of the specimen before and after the test

Test report no. 2016-1400 issued 18.05.2016 page 6 of 6 4. Assessment The material described in chapter one fulfils the requirements: according to DIN EN 1021-1 (October 2014): (ignition source: glowing cigarette) according to DIN EN 1021-2 (October 2014): (ignition source: gas flame ) The tested material passed only the requirements to class P-b and P-c according to DIN 66084. 5. Special note The fire test result is only valid for the material described in chapter 1. In the combination with other materials (for example coatings, deposits) the burning behaviour could be influenced unfavourable that the above classification is not any longer valid. The burning behaviour in combination with other materials has to be tested separately. Frankfurt, the 18.05.2016 H. Anders P. Scheinkönig Tester in Charge Deputy Head of Exova Warringtonfire, Frankfurt The results of the tests relate only to the behaviour of the test specimen which is designated on the top. Test reports are only allowed to be published or reproduced, not changed in form and tenor without permission of the Exova Warringtonfire, Frankfurt. The abridged account of a test report is only allowed with the agreement of the Exova Warringtonfire, Frankfurt. This test report is a translation of the German version 2016-1400 (issued 18.05.2016). In case of doubt only the German version is valid. This test report contains 6 pages.