Encoding Monitor Operations Manual

Similar documents
EQUIPMENT MANUAL, ENCODER: ,

VS-0202 VS User Manual

USER MANUAL VS92A / VS94A / VS98A

AXIS 291 1U Video Server Rack Installation Guide

HDMI Matrix Switch USER MANUAL VM0404H

=============================== WARNING

8-Port HDMI Switch USER MANUAL VS0801H

DELORME. Getting Started with. Earthmate GPS BT-20. Bluetooth

CAUTION RISK OF ELECTRIC SHOCK DO NOT OPEN

9,'(2 #6(3$5$725 8VHU V#0DQXDO 96043;

4 Port VGA Video Audio Switch with RS232 control

HDMI Switch USER MANUAL VS481A

9,'(2 #6(3$5$725 8VHU V#0DQXDO

Business Audio System: Music & Messaging MP3 Player. by Grace Digital Audio. User Guide. Model No. GDI-USBM10

When you switch off your system, or mute the sound, the red indicator light appears immediately, indicating that the subwoofer is not in use.

Serial ATA Hard Drive Docking Station

Video Splitter VS-104 / VS-108 User's Manual

ES-3305P V2 / ES-3308P V2. Quick Installation Guide / v1.0

StructureScan HD Module. Installation Guide ENGLISH

QUICK INSTALLATION. 8-Port Telephony Gateway. Model: SPA8000

BroadBand PowerShield. User Manual

HDMI over Cat5 Video Extender with RS232 and IR Control

Digital Satellite Receiver

Mercury Helios 2 ASSEMBLY MANUAL & USER GUIDE

READ FIRST! Universal Car/Air Adapter User Manual

BPM Series. Metered Rack Mount PDUs. Quick Start Guide. Models Covered:

INSTALLATION GUIDE ConnectLine TV Adapter Getting started

SATA and SAS Hard Drive Backplane

Daily use. Never use alcohol or other solvents to clean any part of the loudspeakers!

This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of the FCC Rules.

Advantium 2 Plus Alarm

Model 70A00-1. GSM Cellular Communications Center

PrintPAD CN3/4/3e/4e. User Guide

PIR-1 Owner s Manual

Square D Clipsal DIN-Rail Four-Channel Auxiliary Input Unit

DVI Video Splitter USER MANUAL VS-162 / VS-164

DMX USB PRO. User Manual.

PCXpocket 440. Professional Digital Audio Card. User s manual. DU IS=A

USB to IDE or SATA Adapter

CX Zoner Installation & User Guide

CONSOLE REMOTE I /O AC 9V

Residential Gateway (RG) Battery Backup REV B

AVerMedia AVerKey imicro User s Manual

USER MANUAL. Model U ForeFront Alarm Card SALES OFFICE (301) TECHNICAL SUPPORT (301) An ISO-9001 Certified Company

Manual. Simrad StructureScan LSS-1 Sonar Module. English

VK-250 WARRANTY REGISTRATION FORM

For the US-market only! CAUTION: To reduce the risk of electric shock, do not remove cover (or back). No User-serviceable parts

MCA Series Multi-Channel Amplifiers. Operation Manual

IMPORTANT SAFETY INSTRUCTIONS

ST122VGAU. Instruction Manual. VGA Video Switch. 2-Port Automatic VGA Video Switch

XTEND 900 MHZ WIRELESS MODEM For use with VEEDER-ROOT EMR³ DATALINK INSTALLATION INSTRUCTIONS Manual , Rev. B

MCR1900 Media Converter 19-Slot Chassis

HP UPS R1500 Generation 3

RC8021 Indoor Camera Installation Guide

VoiceTone T1 USER S MANUAL

2.5/3.5 SATA HDD Docking Station

CAUTION RISK OF ELECTRIC SHOCK DO NOT OPEN

C24-CAMANL Video Server/Encoder

3M Wrist Strap and Footwear Tester 740. User s Guide

USB-to-Serial RS-232 Hub USB-to-Serial RS-422/485 Hub USER MANUAL UC2322 / UC2324 / UC4852 / UC4854

user s manual Battery Case model #: SPB3200 Battery Case Charger for Samsung Galaxy S 4

Package Checklist. Overview. Features. USB Data Link Cable User s Manual. USB Data Link Cable User s Manual 1

Technical Manual. For use with Caller ID signaling types: Belcore 202, British Telecom, & ETSI

MoCA Adapter MC1001 v2 Installation Guide

External Hard Drive esata & USB 2.0 Combo. User Guide English

AXIS T81B22 DC 30W Midspan

How To Use A Ves-0116 Video Splitter With Audio And Video From A Computer Or Tv Aten (Ves-116)

Universal Host. Desktop Digital Hybrid. User Guide. JK Audio

Broadband Telecommunications Drop Amplifier

MB169B+ USB Monitor. User Guide

QNAP RAID Expansion Enclosure Hardware User Manual QNAP Systems, Inc. All Rights Reserved.

USB 2.0 USB 2.0 ETHERNET AUDIO JACK AND RCA VIDEO HDMI MICRO SD CARD MICRO USB POWER

USB to VGA Adapter USB2VGAE2. Instruction Manual. USB 2.0 to VGA Multi Monitor External Video Adapter

TELIKOU Intercom System. TM-200 Main Station. Instruction Manual

User Guide for the Wireless Headset (HS-11W) Issue 1

VOICE RECORDING SYSTEM ISDN PRI / BRI

ACRS 2.0 User Manual 1

Alarm Clock USER GUIDE

USB Port Hub with USB Power Cable. User s Manual

ALARMS-xx. Remote Alarm Unit Setup Guide RESET ALL

Laser Wireless Rechargeable Mouse. User s Manual

Wave/PC Interactive System USB Adapter Kit. Installation Guide

NFC Communication Tray Model: HHX-IT3-Z

SP1790JK 900MHz Wireless Indoor/Outdoor Speakers. User Manual INTRODUCTION FEATURES IMPORTANT SAFETY INFORMATION

ATTENTION RISQUE D ÉLECTROCUTION! NE PAS OUVRIR!

Universal Serial Bus (USB) to DH-485 Interface Converter

BeoLab 7-1 BeoLab 7-2. Guide

CelluLine CGW-TS GSM Cellular Gateway. Installation and Programming Manual

Model PS-4001 Power Supply User Instructions

BOSE. Link AL8 HOMEWIDE WIRELESS AUDIO LINK

Innkeeper PBX. Desktop Digital Hybrid. User Guide. JK Audio

PBXport. Rackmount PBX Digital Hybrid. User Guide. JK Audio

Model: Manual DC: WIRELESS COLOR FORECAST STATION

SoftRAID 5 QUICK START GUIDE. for OWC ThunderBay

BeoLab 1. User s guide

USB Serial Adapter ICUSB232SM3. Instruction Manual. 1-Port 3ft USB to RS232 DB9 Serial Adapter Cable

ECR Shelf System Installation Guide Centralized Rack Mount Call Recording

Composite/S-Video to HDMI Video Converter with Audio

Transcription:

2007 Arbitron Inc Date: June 2007 Document #: 1050-1081 Revision J For Arbitron Encoding Monitor Models: 1000-1135-xx Encoding Monitor 1000-1162-xx Encoding Monitor, RoHS Compliant

Table of Contents 1. CONTACTS...3 1.1. UNITED STATES...3 1.2. INTERNATIONAL...3 2. NOTICE...4 3. DISCLAIMER...5 4. WARNINGS...6 5. INTRODUCTION/OVERVIEW...7 5.1. SUGGESTED PLACEMENT IN AUDIO CHAIN...7 6. INSTALLATION...8 6.1. INSTALLING THE MONITOR...8 7. OPERATION...9 7.1. USING THE MONITOR...9 7.2. CONNECTOR DESCRIPTIONS...11 7.3. EXECUTING HYPER TERMINAL ON THE PC...14 7.4. HYPER TERMINAL SETTINGS...14 7.5. STATUS MESSAGE FORMATS...15 7.6. NO ENCODING MESSAGES...16 8. ELECTRICAL SPECIFICATIONS...17 8.1. ANALOG INPUT SPECIFICATIONS...17 8.2. ALARM (RELAY) SPECIFICATIONS...17 8.3. STATUS (RS-232) SPECIFICATIONS...17 8.4. POWER SPECIFICATIONS...18 9. GENERAL SPECIFICATIONS...19 9.1. PHYSICAL SPECIFICATIONS...19 9.2. ENVIRONMENTAL SPECIFICATIONS...19 FCC DISCLAIMER...20 2007 Arbitron Inc 2

1. CONTACTS If you need assistance or have any questions, please contact or call: 1.1. UNITED STATES EncodingOperations@arbitron.com For any questions regarding this manual, please call 410.312.8123. For any URGENT Encoding Equipment Issues, please contact our 24/7 Encoding Issues Hotline 866.767.7212 Arbitron Inc. 9705 Patuxent Woods Drive Columbia, MD 21046-1572 1.2. INTERNATIONAL internationalppm@arbitron.com Arbitron Inc. 9705 Patuxent Woods Drive Columbia, MD 21046-1572 2007 Arbitron Inc 3

2. NOTICE For the 1000-1135-xx Encoding Monitor: The two cylindrical ferrite cores, Fair Rite part #0431164281 or its functional equivalent, supplied as part of the package, must be installed on the two audio cables in close proximity to the Neutrik XLR connector, close to the connection point at the rear of this Encoding Monitor. (See Figure 1) To install these devices, simply open the core s hinged case and fit the sectioned cores over the cables; once the case is snapped closed, the cores will be firmly secured (see picture on next page). The installation of these ferrite cores is not necessary for the 1000-1162-xx Encoding Monitor, RoHS Compliant. Figure 1: Ferrite Cores 2007 Arbitron Inc 4

3. DISCLAIMER It is the responsibility of the Installer to scrupulously adhere to the above-cited instructions; Arbitron cannot be held accountable for any infringement. All the information contained within is copyrighted by Arbitron and may not be reproduced, copied or distributed to any third party without written consent of Arbitron. NOTWITHSTANDING ANYTHING CONTAINED IN THIS MANUAL OR ANY OTHER AGREEMENT, THE SOLE AND EXCLUSIVE REMEDY, AT LAW OR IN EQUITY, FOR ARBITRON S AND/OR ANY THIRD PARTY S BREACH OF ANY WARRANTY, EXPRESS OR IMPLIED, INCLUDING WITHOUT LIMITATION ANY WARRANTY OF MERCHANTABILITY OR FITNESS, AND THE SOLE AND EXCLUSIVE REMEDY FOR ARBITRON S AND/OR ANY THIRD PARTY S LIABILITY OF ANY KIND, INCLUDING WITHOUT LIMITATION LIABILITY FOR NEGLIGENCE OR DELAY WITH RESPECT TO THE ENCODING MONITOR, SHALL BE LIMITED TO $100 IN THE AGGREGATE. IN NO EVENT SHALL ARBITRON AND/OR ANY THIRD PARTY BE LIABLE FOR SPECIAL, INCIDENTAL, CONSEQUENTIAL OR PUNITIVE DAMAGES. 2007 Arbitron Inc 5

4. WARNINGS To reduce the risk of personal injury, electrical shock, fire, or damage to the MONITOR, DO NOT expose this unit to rain or moisture. Due to the danger of personal injury, electrical shock, or damage to the instrument, ONLY Arbitron authorized service personnel shall gain access to the inside of the MONITOR. DO NOT disconnect the earth ground from the power cord since this is a very important safety feature. The MONITOR should be mounted securely in a rack. The sides must be free of obstructions to provide adequate airflow through the instrument. The installation of the ferrite cores is of paramount importance for maintenance of compliance to the FCC part 15 and CISPR 22 Radiated Emission Class B Normative. CAUTION: FAILURE TO INSTALL THE ENCODING MONITOR IN ACCORDANCE WITH THE SPECIFICATION IN THIS MANUAL AND/OR FAILURE TO MAINTAIN BROADCAST SIGNALS IN ACCORDANCE WITH GENERAL INDUSTRY STANDARDS AND SPECIFICATIONS MAY RESULT IN THE ENCODING MONITOR NOT OPERATING PROPERLY. 2007 Arbitron Inc 6

5. INTRODUCTION/OVERVIEW The Arbitron Studio Grade Encoder (SGE) inserts inaudible symbols into the audio of broadcasts according to Arbitron patented algorithms. The instrument described in this document, the Encoding Monitor (MONITOR), is used to detect encoded audio program material. The station engineer can use this instrument to validate that their station is transmitting encoded program material. Arbitron strongly advises the station engineer to use air return audio when connecting to the MONITOR, to detect cases where the SGE has been accidentally patched out of the audio stream. RoHS Compliance (Restriction of Hazardous Substances) is the nickname given to the European Union's directive 2002/95/EC on the restriction of the use of certain hazardous substances in electrical and electronic equipment. RoHS seeks to reduce the amount of hazardous materials entering electronic products. The Arbitron 1000-1162-xx Encoding Monitor, RoHS Compliant is designed to meet the requirements of the European Union's directive 2002/95/EC. All of the other Arbitron Encoding Monitors listed on the title page of this manual have not been designed to meet the requirements of the European Union's directive 2002/95/EC. 5.1. SUGGESTED PLACEMENT IN AUDIO CHAIN Arbitron recommends that the MONITOR be installed such that it receives program material that has exited the transmitter or over-the-air broadcasts. This will insure that your media consumers are exposed to encoded program material. The MONITOR operates optimally with a nominal average audio input level of +8 dbu. 2007 Arbitron Inc 7

6. INSTALLATION 6.1. INSTALLING THE MONITOR 6.1.1. Place instrument into a 19 rack in an indoor environment. 6.1.2. Install securely using screws in each of the four front panel corners. 6.1.3. See Figure 2. Slide switch S1 to 600 if 600 ohm input termination is desired or to HI if a 12k ohm input bridging impedance is desired. 6.1.4. Connect the power cord to the MONITOR and to the same plug strip that supplies power to the instruments that will be connected to the input of the MONITOR. The MONITOR has no power switch. The POWER indicator LED will be lit green. 6.1.5. DO NOT block or otherwise impede airflow through the sides of the instrument. 6.1.6. Connect the received program material signals into the connectors marked IN on the MONITOR. If the program material is always mono and only one audio cable is used (single channel mode), then the MONITOR can be configured for single channel operation. In single channel mode, the channel A analog input must be used. The default decoding mode is dual channel. 2007 Arbitron Inc 8

Figure 2: Rear-View, Monitor 7. OPERATION 7.1. USING THE MONITOR The station engineer has been provided several monitoring options: If desired, they can monitor the front panel LED. When the MONITOR is receiving the correct encoded material, the front panel LED will be a CONSTANT GREEN. When incorrectly encoded material is presented to the audio inputs, the front panel LED will FLASH RED (see notes below). 2007 Arbitron Inc 9

If the engineer cannot always visually monitor the MONITOR front panel, the engineer can use the rear panel ALARM connection. This connection provides both a normally open and normally closed relays which will energize when indicating a loss of encoding. This connection can be made externally to either an audible or visual indicator, or both. It is highly recommended that the monitor s ALARM connection should be used in conjunction with your station s current Air Fault Alarm system (or similar). Provision has also been made for connection to a remote monitor device via RS232. See below for specification of connection to both the ALARM and RS232 connections. Note: The MONITOR has been configured with a nominal alarm delay of approximately 3 minutes. In other words, the MONITOR will not assert an alarm condition until it fails to detect the specified code for approximately 3 minutes. At that time, the alarm relay will close (or open), the LED will turn RED, and a statement will be issued via the RS232 connection. When an encoded signal is applied to the input, the MONITOR will release the alarm condition immediately. Please see below for information on the specifics of the alarm assertion. 2007 Arbitron Inc 10

7.2. CONNECTOR DESCRIPTIONS 7.2.1. Analog Input Connector Description Input connectors on the MONITOR are female; thus, the mating XLR cable connector is required to be male. Balanced XLR pin-out for the Arbitron MONITOR is as follows: Pin 1- Shell or ground Pin 2- High Pin 3- Low 2007 Arbitron Inc 11

7.2.2. Alarm Connection Description On the rear panel of the MONITOR is a DB9 male connector labeled, ALARM CONNECTION. This connector provides a normally open and normally closed contact switch to monitor the presence of encoded program material and to monitor the status of the MONITOR itself. To allow remote monitoring of the MONITOR status, the following connections are detailed: CODE STATUS Status = CODES Status = NO CODES Pin 2 Open to pin 3 Shorted to pin 3 Pin 4 Shorted to pin 3 Open to pin 3 OPERATIONAL STATUS Status = MONITOR Normal Status = MONITOR Failure Pin 7 Open to pin 8 Shorted to pin 8 Pin 9 Shorted to pin 8 Open to pin 8 The pins are connected to an internal relay of the MONITOR whose relay contacts are rated at 0.3A max, 24VDC. If the front panel LED is SOLID RED and the Monitor failure alarm is asserted, then a system failure has occurred. 2007 Arbitron Inc 12

7.2.3. STATUS (RS-232) Description On the rear panel of the MONITOR is a DB9 female connector labeled, STATUS RS- 232. This is an RS-232 serial port that is output only. To allow remote monitoring of this MONITOR, the following connections are detailed: a. Pin 3 Transmit Data (TD) b. Pin 5 Chassis ground (Common) To communicate with the MONITOR, the following hardware is required. PC (Desktop or Laptop) running Windows 95 or later software, and that has a 9 pin D serial port. (Other computers/software configurations may work, but have not been tested.) RS-232 DB-9 Cable with a Null-Modem adapter Plug one end of the RS-232 DB-9 cable with a Null-Modem adapter into the STATUS PORT in the rear of the Encoding Monitor and the other end into the COM Port of the PC to allow remote monitoring. On the front panel of the MONITOR is a DB9 female connector labeled Service Port. THE SERVICE PORT CONNECTOR IS FOR AUTHORIZED USERS ONLY. Do not use this port unless authorized to do so by Arbitron. A RS-232 DB-9 Cable and a special adaptor/connector (per Arbitron drawing number 1002-0610) are required to use the features of the service port. 2007 Arbitron Inc 13

7.3. EXECUTING HYPER TERMINAL ON THE PC Go to Start/Programs/Accessories/Communications/HyperTerminal to start the program. It will then ask for a name on the Connection Description window. Type Local for the name to begin. 7.4. HYPER TERMINAL SETTINGS 8 data bits 1 stop bit no parity 9600 baud rate xon/xoff flow control Choose the serial port, COM1 COM4, where the Encoding Monitor is connected. 2007 Arbitron Inc 14

7.5. STATUS MESSAGE FORMATS 7.5.1. Boot-up Messages System boot-up starts when power is applied to the MONITOR. If the HyperTerminal is active during system power on, as the system is booted up the rear panel STATUS serial port sends out the following messages: <NOTE@P[Encoding Monitor Boot Loader][Vx.xx]> <NOTE@P[Main program checksum][valid]> to indicate self test pass or <NOTE@P[Main program checksum][invalid]> to indicate self test fail. <NOTE@P[Encoding Monitor Main][Vx.xx]> 7.5.2. Encoding Present Messages When the Monitor has determined that a valid code is present in the program material, the status port sends out the following messages: <NOTE@P[000x][station_name]> where x = 0-9. A new output line is displayed every 20 seconds. (Note: This is not indicative of the detection rate.) The number of each line ( e.g., 0001, 0002) is output to show activity on the line, since the first portion of this message may not change. 2007 Arbitron Inc 15

7.6. NO ENCODING MESSAGES If a valid code is not detected in the program material, the status port sends out the no code message: <NOTE@P[000x][Encoding not detected]> where x = 0-9. A new output line is displayed every 20 seconds. The number of each line ( i.e. 0001, 0002) is output to show activity on the line, since the first portion of this message may not change. If a code is detected in the program material, but the detected code is not one of the identification codes programmed into the unit, the status port sends out the unknown station message: <NOTE@P[000x][Unknown Station]> where x = 0-9. A new output line is displayed every 20 seconds. The number of each line ( i.e. 0001, 0002) is output to show activity on the line, since the first portion of this message may not change. 2007 Arbitron Inc 16

8. ELECTRICAL SPECIFICATIONS 8.1. ANALOG INPUT SPECIFICATIONS 8.1.1. Input Impedance User Selectable 600Ω, balanced terminated ( 600 ) or 12kΩ, balanced bridging ( HI ) 8.1.2. Analog Input Level Average Minimum: 0dBu over 20Hz-20kHz Average Nominal: +8dBu over 20Hz-20kHz Absolute Maximum: +20dBu over 20Hz-20kHz 8.1.3. Common Mode Rejection Ratio Better than 70dB @60Hz 8.2. ALARM (RELAY) SPECIFICATIONS 8.2.1. Absolute Maximum Voltage Input 24VDC or 24VAC 8.2.2. Absolute Maximum Current Input 300 ma 8.3. STATUS (RS-232) SPECIFICATIONS 8.3.1. Standard TIA/EIA-232-F 2007 Arbitron Inc 17

8.3.2. Minimum Output Voltage into 3kohm load ±5V 8.3.3. Baud Rate 9600 8.3.4. Parity None 8.3.5. Number of Data Bits 8 8.3.6. Number of Stop Bits 1 8.3.7. Recommended Flow Control XON/XOFF 8.4. POWER SPECIFICATIONS 8.4.1. Voltage 100 240 VAC 8.4.2. Current 1.4 Amps maximum 8.4.3. Frequency 50/60Hz 8.4.4. Connector Type IEC 2007 Arbitron Inc 18

9. GENERAL SPECIFICATIONS 9.1. PHYSICAL SPECIFICATIONS 9.1.1. Dimensions 48 x 16.5 x 4.5 cm (L x D x H) 9.1.2. Weight 2.7 kg 9.2. ENVIRONMENTAL SPECIFICATIONS 9.2.1. Temperature Range Operating: 0-45 C Storage: 0-70 C 2007 Arbitron Inc 19

FCC DISCLAIMER This equipment has been tested with the limits for a Class A digital device, pursuant to Part 15 Subpart B of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment. This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the instruction manual, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures: Reorient or relocate the receiving antenna. Increase the separation between the equipment and receiver. Connect the equipment into an outlet on a circuit different from that to which the receiver is connected. Consult the dealer or an experienced radio/tv technician for help. 2007 Arbitron Inc 20