Permanent Magnet Generator (PMG) User s Manual

Similar documents
Automatic Voltage Regulator User s Manual

Mounting Instructions. Torque Transducer. A en

1000-LB. TRAILER JACK OWNER S MANUAL

PANCAKE CAPACITOR GENERATOR Installation, Operation and Maintenance Manual

Step 1. Item 6. Item 1

Strut Spring Compressor

DO NOT OPERATE LANCELOT OR SQUIRE WITHOUT FIRST ADJUSTING THE SAFETY GUARD. ( See Below)

Single-Phase AC Synchronous Generator

Permanent Magnetic Generator Construction Manual

Operation manual. drill rig KERN-DEUDIAM KBS-Series K100

Loewe GK Installation and operating manual

Tri-Homo Style Operation and Maintenance Instructions

Machine needle shut-off nozzle type HP

PM734F - Technical Data Sheet Winding 28

Welcome to Linear Controls Quarterly Training

Pet hair clipper. Model Diagrams within this manual may not be drawn proportionally.

INSTALLATION AND MAINTENANCE INSTRUCTIONS FOR THREE PHASE INDUCTION MOTORS

A.V.R. R250. Installation and maintenance R250 0V E+ E- VOLT STAB FREQ. & L.A.M. CONFIG. 50Hz. 47.5Hz. 57Hz LAM 1 13% 2 25% OFF LAM OFF 9

PTO OWNER S MANUAL ALLISON FAMILY CODE. pag.1

Preview of Period 16: Motors and Generators

LUCCI AIRFUSION QUEST II CEILING FAN

IEC Three Phase AC Motors (Aluminum Frame) Installation & Operating Manual

Alfra Rotabest 100 Metal Core Drilling Machine. Operation Manual

lamp post light Set up and Operating Instructions

HCM434F - Winding 311 APPROVED DOCUMENT. Technical Data Sheet

Achat 115MA full-range speaker. user manual

TECHNICAL SUPPORT MANUAL 3 Phase Air Conditioner Component R2A3**GHR

DM-PD (English) Dealer's Manual PD-MX80

Installation and safety instructions for AC/DC built-in devices

PI734D - Technical Data Sheet

PI734B - Technical Data Sheet

8" BENCH GRINDER OWNER'S MANUAL

Series Hose Reels

Mini Pallet Jack OWNER S MANUAL

MBSAW. Meat Cutting Band Saw With Meat Grinder Assembly & Operating Instructions

National- Spencer Inc.

UCI274C - Technical Data Sheet

aseries A13B Mini Bullet Camera User Manual

UCI274H - Technical Data Sheet

Replacement of 600-Ampere Bushing and 200-Ampere Bushing-Well Adapters

WARNING: Important: Keep these instructions for future reference. Gate Instructions (1) Assembly and Installation Instructions

Equipment: Power Supply, DAI, Wound rotor induction motor (8231), Electrodynamometer (8960), timing belt.

Outdoor 33.6W Dual Port Passive Power-over-Ethernet Midspan For External Security Cameras and Wireless Access Points

Day / Night IR Color Camera User Manual V2.1.0

This instruction is valid for all ACD pump models shown on page 2

Model 1756 Test Lead Kit

Motor Fundamentals. DC Motor

Allen-Bradley HP AC Line Filter Kit

GGS 27 GGS 27 C PROFESSIONAL

Owner s Manual & Safety Instructions

OPERATOR S MANUAL 18 VOLT, 1 HOUR CHARGER

Adjustment functions for both span and shift have been incorporated

Tube-Line Accumul8/+2/+4

33.6W Power over Ethernet Waterproof Adapter PoE Plus Single Port Injector for Outdoor Application

IMPORTANT SAFETY NOTICE

POSEIDON 2-29, 2-25 & 2-22 POSEIDON 2-29, 2-25 & 2-22 XT

Cable Drum Machine. Operation Manual BC260 SERIES. Cleans 1 1/4" to 3" lines up to 50'

INSTALLATION, SERVICE AND MAINTENANCE MANUAL

CAT AVR V2.3. Instruction Manual. Voltage regulator for generators. March 2008

ST Style Generator. Owners/Operators Manual

Industrial Process Pump Safety Manual IMPORTANT SAFETY NOTICE

PowerFlex 700H and 700S AC Drives Frame 11 Main Fan Capacitor Replacement Kit

804 Ti Stand. Manual EN

Excitation.

60 WATT LED TRIPLE BEAM WORKLIGHT

R448 & R448 V50 A.V.R.

Compensation Unit in X-, Y-, and Z-Direction AGE-S-XYZ

Installation instruction

Wiring Instructions and Operating Manual 12 POINT ULTRABEAM REMOTE MONITORING SYSTEM

HYDRAULIC LIFT TABLE CART 2200-LB.

15GAL STEEL OIL DRAIN WITH 110V PUMP

Installer s Guide WARNING: 18-GJ11D1-2. Ultraviolet (UV-C) Lamp Kit for 2-5 Ton Air Handlers HAZARDOUS VOLTAGE - DISCONNECT POWER BEFORE SERVICING

Andersen Electric Window Opener for Andersen Awning and Roof Windows

Wind Generator. NEMO400 Instruction Manual. Suzhou Shoot Power Equipment Co., Ltd. Serial number:

MICA HEATER INSTRUCTION MANUAL Model No: UHM V 50Hz 2200W

Subminiature Load Cell Model 8417

Trillium 40 Axis Spring Tensioner Wire Replacement Instructions

Heater Replacement Procedure

Service and Maintenance. SEW-EURODRIVE Driving the world

Operator s Manual POST HOLE DIGGER ACCESSORIES DOWN FORCE KIT. 5BPPHD002 (fits models PHD300 & 400) 5BPPHD005 (fits model PHD200) HOOKUP STAND

Unit 4: Electricity (Part 2)

ORTHOBLOC Drive systems. Installation. This manual is to be given to the end user en / k. R max - 5 mm.

Instruction Manual. Fun Pop 8oz. Popper

SIMATIC S Getting Started for First Time Users. Order No.: 6ZB5310-0NC02-0BA0 04/2007 A5E

120Volt 60-70A ARC WELDER Rev

Electric Meat Grinder

Mini-led spotlight with magnetic base

Motors and Generators

6 FUNCTION HAMMER DRILL

Flat Bottom Long Ram Hydraulic Jack

Rules for Classification and Construction Additional Rules and Guidelines

Operation Instructions. KleeBlower Compressor/Vacuum pumps. Models: KB129 KB8415

Unit 33 Three-Phase Motors

I nstallation. M100Q Series Proportional Actuator with R81Q Controller Board for Thermistor Sensor Applications. Tools Needed.

ROUTER TABLE INSERT ASSEMBLY AND OPERATING INSTRUCTIONS

Precision Miniature Load Cell. Models 8431, 8432 with Overload Protection

USER MANUAL. DriveMaster 2.5, 3.6 ELECTRIC PROPULSION SYSTEM

12 SOLAR PHOTOVOLTAIC POWER SUPPLY SYSTEMS by John Ware. PV modules are current-limiting

Owners & Installation Manual for the Sheridan, Mountainair, Pine Valley and Old Forge Ceiling Fan Family

Transcription:

Permanent Magnet Generator (PMG) User s Manual Type designation: Application: PMG 0120A08, PMG 0120B08, PMG 0120C08 PMG 0120D08, PMG 0120E08, PMG 0120F08 AMG 0200 04~AMG 0450 04 Prep. PEYA 07.02.2012 Permanent Magnet Generator (PMG) Appr. TUTU 09.02.2012 User s Manual 2 Resp. dept. R&D No. of sh. 8 8AMG 5856731 en D 1

1 GENERAL INFORMATION 1.1 SAFETY Carrying out certain operations, maintenance procedures and some operation procedures can be dangerous or harmful if the correct safety precautions are not observed. Before attempting to set up, operate or adjust synchronous machines, operators and maintenance people must be technically qualified and must have received the appropriate training. Before carrying out any operations and maintenance for the PMG, personnel must go through the User s Manual- AMG Synchronous Generator Industrial Application Series, which is attached with each machine supplied by ABB, and follow all the safety instructions. Symbols and decals Personnel must be familiar with all the warning symbols and decals fitted to the machinery. Failure to recognize a warning and read the associated safety instructions may result in injury or death. Electrical hazard The PMG will induce high voltage when the rotational speed is on certain level. During PMG installation, maintenance or setting-up, prevent touching all voltage parts without protective insulation. Moving parts Covers must only be removed by qualified personnel as part of an installation, maintenance or setting-up procedure. They must be re-fitted as soon as possible. Keep hands and loose clothing clear of all moving parts. High temperatures PMG will reach high temperatures. Avoid contact with them. Always wear protective gloves when working in the vicinity. Magnetic fields There is a magnetic field presence in the immediate area surrounding PMG, even it is not under operating. Ensure that devices that can be influenced or wiped (e.g. magnetic disks, credit cards, watches etc.) by the effects of electro-magnetism are removed from the area. The magnetic field from PMG may affect the operation of some medicine device (e.g. pacemaker). Therefore, personnel with this kind of devices should avoid operating close to the PMG. 1.2 DESCRIPTION The PMG (Permanent Magnet Generator) is a system which is used for secondary exciting. The PMG provides stable and reliable electric energy for AVR regardless the generator s terminal voltage. The generator with PMG excitation system can provide 300 % rated current during short-circuit, which occurs for 5-10 seconds. 1.3 TYPE DESIGNATION ABB PMG type designation is defined as follows: 8AMG 5856731 en D 2

1.4 TYPE SPECIFICATION There are 6 types of PMG which are designed for standard industrial generators AMG 0200 04~AMG0450 04: PMG 0120A08 for AMG 0200 04 PMG 0120B08 for AMG 0250 04 PMG 0120C08 for AMG 0280 04 PMG 0120D08 for AMG 0315 04 PMG 0120D08 for AMG 0355 04 PMG 0120E08 for AMG 0400 04 PMG 0120F08 for AMG 0450 04 1.5 STRUCTURE All the PMG consist of a PMG rotor, a PMG stator, a retainer and a cover (see: Figure 1) Figure 1: PMG structure. 1.6 OPERATION TEMPERATURE Since the performance of permanent magnet is sensitive to the high temperature, pay attention to storage and operational conditions as follows: Operation temperature -20 to +75 Storage temperature -55 to +85 8AMG 5856731 en D 3

2 CONNECTION ABB PMG 0120A08 PMG 0120F08 devices running with the AVR. Before carrying out any adjustment, maintenance or operation, please go through the AVR User s Manual and Main connection diagram, which is attached for each machine delivered by ABB. Attention! Incorrect setting of the AVR may damage the generator or generating set. Make sure the personnel who do changes in the AVR-setting are technically qualified and go through the user s manual carefully. The principle of PMG excitation system is shown in Figure 2. Figure 2: Principle of generator with PMG excitation system 8AMG 5856731 en D 4

3 TECHNICAL CHARACTERISTICS The PMG technical characteristics are shown in Table 1: PMG technical characteristics. Table 1: PMG technical characteristics Stator L-L resistance at 20 ] No-load voltage at 1500 rpm/[v RMS ] No-load voltage at 1800 rpm/[v RMS ] PMG 0120A08 2,3 130 155 PMG 0120B08 2,5 135 160 PMG 0120C08 2,5 155 185 PMG 0120D08 2,5 155 185 PMG 0120E08 2,5 175 215 PMG 0120F08 2,5 175 215 8AMG 5856731 en D 5

4. Installation 4.1 Mounting the PMG 0120A08 Remove the ND-end shield grille. Install the retainer of PMG stator on the NDE shield, then tighten 4 pcs of hexagonal M8 screws (Figure 3). Use the spanner to fasten the PMG rotor on the main shaft. Tighten the screw connecting the PMG rotor to the main rotor ND-end. Using 2 M6 threaded rods to lead the stator (Figure 4). Once the stator is in position, tighten 2 pcs of hexagonal M6 screws. Remove the M6 threaded rods (Figure 4), tighten the other 2 pcs of hexagonal M6 screws. Connect the PMG outlet wire to the AVR. Cover the PMG with the NDE shield grille. Figure 3: PMG retainer attached to the NDE-shield Figure 4: Using 2 M6 threaded rods the stator is led to the assembly. 8AMG 5856731 en D 6

4.2 MOUNTING of PMG 0120B08, 0120C08, 0120D08, 0120E08 Remove the ND-end shield grille. Install the retainer of PMG stator in the NDE shield, then tighten 4 pcs of hexagonal M8 screws (see: Figure 3). Hammer the cylindrical pin in the ND-end of the shaft (see: Figure 5). Install the shaft of PMG rotor in main shaft, then tighten the long hexagonal M10 screw (see: Figure 6). Use 2 pcs of M6 threaded rods to lead the stator in correct position (see: Figure 4). Once the stator is in right position, tighten 2 pcs of M6 hexagonal screws. Remove the M6 threaded rods (Figure 4), and tighten the other 2 pcs of M6 hexagonal screws. Connect the PMG outlet wire to the AVR. Cover the PMG with the NDE shield grille. Figure 5: Cylindrical pin attached to the shaft ND-end. Figure 6: The PMG shaft pressed in and attached with main rotor with the hexagonal M10 screw. 8AMG 5856731 en D 7

4.3 Mounting the PMG 0120F08 Remove the ND-end shield grille. Install the retainer of PMG stator and end cover in the NDE shield, then tighten 4 pcs of socket M12 screws and 4 pcs of hexagonal M6 screws (see: Figure 7). Install the shaft of PMG rotor in main shaft, then tighten the 3 pcs of hexagonal M8 screw (see: Figure 7). Use 2 pcs of M6 threaded rods to lead the stator in correct position (see: Figure 4). Once the stator is in right position, tighten 2 pcs of M6 hexagonal screws. Remove the M6 threaded rods (Figure 4), and tighten the other 2 pcs of M6 hexagonal screws. Install the grease box with 2 pcs of hexagonal M6 screws. Connect the PMG outlet wire to the AVR. Cover the PMG with the NDE shield grille. Figure 7: The PMG shaft pressed in and attached with main rotor with 3 pcs hexagonal M8 screw. Attention! Pay attention to intense magnetic field of PMG unit in every assembling step described above in this Chapter 4. Installation. 8AMG 5856731 en D 8