Electroblotting Systems

Similar documents
EZ-PAGE Electrophoresis System USER MANUAL

The table below lists the symbols used on the Clamp and/or in this manual. Important Information. See manual.

3 WATT LED SPOTLIGHT Model No. SLM

Western Blotting For Protein Analysis

About this Manual. Support for Your Product

MODEL G300 BRAKE BLEEDER

Instructions A Amp AC/DC Current Probe

i410/i1010 AC/DC Current Clamp

STANDARD OPERATING PROCEDURE

EPM3. Phase Sequence and Motor Rotation Tester. Users Manual

el-720 Carbon Dioxide Gas Leak Detector User s Guide

Instruction Manual. Image of SP-3015 & SP Important Safeguards. Automatic Dispensing Hot Water Pot with Reboil Function

Ultrasonic Jewelry/DVD Cleaner. make jewelry, dvds and more sparkle like new

UNIVERSAL LUMBAR INSTALLATION INSTRUCTIONS

Propane Conversion Kit PROPANE CONVERSION KIT INSTALLATION MANUAL

Important Operating Instructions and Warranty Information On Your New Electronic AMSEC Safe

MIC-WKT and MIC-WKT-IR

Western Blotting: Mini-gels

FLUORESCENT UV- RING LIGHT OPERATING INSTRUCTION

DNA SPOOLING 1 ISOLATION OF DNA FROM ONION

Important Operating Instructions and Warranty Information On Your New Electronic AMSEC Safe

CappController Pipette Controller. Operation Manual Version:

ClearView 100. Instruction Manual

64-CHANNEL INTEGRATED AMPLIFIER

Instruction Manual. AWK-115S

BroadBand PowerShield. User Manual

15GAL STEEL OIL DRAIN WITH 110V PUMP

323/324/325. Calibration Manual. Clamp Meter

804 Ti Stand. Manual EN

Bathroom faucets. 10 Year Limited Warranty INCLUDED

6 & 12 Volt Battery and Systems Tester with 100 Amp Load

Hydraulic Punch Driver Kit

Digital Fingerprint safe

For safety information, see the ABI PRISM 310 Genetic Analyzer User s Manual (PN or ).

Portable Air Conditioner

Product name Company Cat # PowerPac Basic Power supply Bio Rad Mini Protean electrophoresis system Mini trans blot cell Bio Rad

NFC Communication Tray Model: HHX-IT3-Z

DUSTTRAK AEROSOL MONITOR SOLAR POWER KIT MODEL

Hot Water Urns. all models. Helpline. v3.0

Geocontrol PRO INSTALLATION AND OPERATION MANUAL. Rev. 1 03/18/04 Part #

TT TOYS TOYS - OWNER S MANUAL. We are delighted that you have decided to purchase this TT Toys Toys children s car.

Pocket Tach 99 (PT99) Non-Contact Tachometer

CoolDrive 5. User s Manual

How To Use The Visifault Visual Fault Locator

AMU PROFESSIONAL VIDEO AND AUDIO MONITORING UNIT OPERATOR'S HANDBOOK ISSUE A3

CompacVideo Otoscope. Model (NTSC) and 23120P (PAL) Operating Instruction Manual

NewAir AC-10000E, AC-10000H Portable Air Conditioner Owner s Manual PLEASE READ AND SAVE THESE INSTRUCTIONS

Advantium 2 Plus Alarm

In this experiment, we will use three properties to identify a liquid substance: solubility, density and boiling point..

MAP COFFEE MIA CAPSULE COFFEE MACHINE INSTRUCTION MANUAL MODEL: CM4725. Read this manual thoroughly before using and save it for future reference

Milwaukee USER MANUAL

Pet hair clipper. Model Diagrams within this manual may not be drawn proportionally.

DC REFRIGERATORS 12/24 VOLTS INSTALLATION AND OWNER S MANUAL

Omega Pipettor. Operating Instructions

staple gun with 5/16 Long staples

EVAPORATIVE AIR COOLER INSTRUCTION MANUAL

DTM04 TANK MONITOR DTM08 TANK MONITOR Dtm12 TANK MONITOR. Installation and Operation Manual

INFRARED QUARTZ WALL HEATER

Bathroom Sinks. 10 Year Limited Warranty INCLUDED

2. Cut 6 sheets of Whatman 3MM paper and 1 sheet of blotting membrane to the size of the gel, or slightly smaller.

ACE. PIVOT AND BI-FOLD DOOR Installation and User Guide. These instructions must be left with the user W2-D

PIPELINE INSPECTION COMPANY LTD. Portable Holiday Detectors. OPERATING INSTRUCTIONS SPY PORTABLE HOLIDAY DETECTORS Models 780, 785, & 790

Nest Learning Thermostat Installation Guide. Installation step-by-step

SBC90. Abrasive Blast Cabinet Assembly & Operating Instructions

HVAC Clamp Meter. Users Manual

ATS Overhead Table Shelf System INSTRUCTION MANUAL

OPERATING INSTRUCTIONS

62 Max/62 Max + Infrared Thermometer

6 H2O + 6 CO 2 (g) + energy

ExStik TM ph Waterproof Meters

Safety Notices 安 全 通 知 和 标 签. Securite, Consignes et etiquettes. P/ACE MDQ plus Capillary Electrophoresis System

Leak Detection System

1 Ton Telescoping Gantry Crane

COMPACT ELITE MAT CUTTER

VACUUM CLEANER INSTRUCTION MANUAL

Owner s Manual & Safety Instructions

MIC-BP4 Bi-Phase Converter Card For the MIC400 series camera


tire inflator with pressure gauge

Instructions & Safety Information Models A220-20D and A220-20L Version 2

IMPORTANT INFORMATION

Portable Holiday Detectors

RZ Guardrail System Installation Manual

NewAir AC-10100E / AC-10100H Portable Air Conditioner Owner s Manual PLEASE READ AND SAVE THESE INSTRUCTIONS

Tipping Bucket Rain Gauge Models 6011-A 6011-B

LUCCI AIRFUSION QUEST II CEILING FAN

ROTOR LOADER OWNER S MANUAL

Operating instructions in the back. PD1020L

Bottom Loading Water Dispenser

Introduction 1 The system 1 The meter 2 The display 3 The mode 3 The measurement 4 Coding the meter 4 How to obtain a drop of blood 6 Application of

Global Water Instrumentation, Inc.

Global Water Instrumentation, Inc.

Home Owners Guide HR SERIES HEAT RECOVERY VENTILATOR (HRV) Models HR100V, HR160H & HR220H RESIDENTIAL USE ONLY HR160H & HR220H

USER INSTRUCTIONS FOR 10 LITRE PORTABLE DEHUMIDIFIER MODEL NO. DHMD102

SUB Universal water baths SBB Boiling baths JB, PB Unstirred water baths

Auxiliary Rams USERS MANUAL

ALPs (Automated Labware Positioners)

1 / 4 IN. FFL x 4 FT. 9 IN. 1 / 2 IN. ACME x 4 FT. 9 IN. Gauge Accuracy +/-2% Set includes Quick Disconnect Valves

When you switch off your system, or mute the sound, the red indicator light appears immediately, indicating that the subwoofer is not in use.

Transcription:

user manual Electroblotting Systems Complete Electroblotting System for 10 10 cm Mini Gels, Cat. No. E4103 Complete Electroblotting System for 20 20 cm Standard Gels, Cat. No. E4203 um DNTV100-EBK-IM/Rev. A0/08-11

Contents Safety Warnings and Precautions ii General Information 1 Packing Lists 2 System Details 3 Using the Denville Electroblotting Units 4 A. Attaching Electrode Leads to the Lid 4 B. Care and Maintenance 5 C. Tank and Cassette Preparation 6 D. Final Assembly and Transfer 7 Ordering Information 8 Warranty 9 Disposal 10 pi

Safety Warnings and Precautions Important user information Please read this entire manual to fully understand the safe and effective use of this product. The exclamation mark within an equilateral triangle is intended to alert the user to the presence of important operating and maintenance instructions in the literature accompanying the instrument. Should you have any comments on this manual, we will be pleased to receive them at: Denville Scientific, Inc. P.O. Box 4588 Metuchen, NJ 08840-4588 Denville Scientific, Inc. reserves the right to make changes in the specifications without prior notice. When used correctly, these units pose no health risk. However, these units can deliver dangerous levels of electricity and are to be operated only by qualified personnel following the guidelines laid out in this instruction manual. The unit must never be used without the safety lid correctly in position. The unit should not be used if there is any sign of damage to the external tank or lid. These units comply with the statutory CE safety directives: 73/23/EEC: low voltage directive: IEC 1010-1:1990 plus amendment 1:1992 EN 61010-1:1993/BS EN 61010-1:1993 pii

General Information The Denville Electroblotting Systems provide a cost-effective, safe, and easy to use system for the transfer of proteins and nucleic acids from 10 10 cm mini and 20 20 cm standard gels. Both units are supplied with four asymmetric color-coded cassettes as a unique design feature to prevent them from being inserted into the tank in the wrong orientation, against the direction of transfer. Operational Model Buffer Volume Maximum Voltage E4103 2 L 100 V E4203 6.3 L 200 V p1

Packing Lists The packing lists should be referred to as soon as the unit is received to ensure that all components have been included. The unit should be checked for damage when received. Be sure to keep all packaging material for damage claims for to use should it become necessary to return the unit. Please contact your supplier if there are any problems or missing items. Complete Electroblotting System for 10 10 cm Mini Gels Package includes: Cooled tank, lid, a black cable, a red cable, 4 electroblotting cassettes, and 8 fiber pads. Complete Electroblotting System for 20 20 cm Standard Gels Package includes: Cooled tank, lid, a black cable, a red cable, 4 electroblotting cassettes, and 8 fiber pads. p2

System Details Usage guidance and restrictions Maximum altitude 2000 m. Temperature range between 4 C and 60 C. Maximum relative humidity 80% for temperatures up to 31 C decreasing linearly to 50% relative humidity at 40 C. Not for outdoor use. This apparatus is rated POLLUTION DEGREE 2 in accordance with IEC 664. POLLUTION DEGREE 2, states that: Normally only non-conductive pollution occurs. Occasionally, however, a temporary conductivity caused by condensation must be expected. p3

Using the Denville Electroblotting Units A. Attaching Electrode Leads to the Lid 1 Note the position of the lid on the unit. This shows the correct polarity and the correct orientation of the cables, black is negative and red is positive. 2 Remove the lid from the unit. Note if the lid is not removed, fitting the cables may loosen the gold plug and cause damage to the electrode. 3 Screw the cables into the tapped holes as fully as possible so that there is no gap between the lid and the leading edge of the cable fitting. 4 Refit the lid. p4

B. Care and Maintenance Units are best cleaned using warm water and a mild detergent. Water at temperatures above 60 C can cause damage to the unit and components. The units should not be left in detergents for more than 30 minutes. The tank should be thoroughly rinsed with warm water and distilled water to prevent build up of salts but care should be taken not to damage the electrode. Vigorous cleaning is not necessary or advised. Air drying is recommended before use. Caution! The units should never come into contact with the following cleaning agents, these will cause irreversible and cumulative damage: Acetone, Phenol, Chloroform, Carbon tetrachloride, Methanol, Ethanol, Isopropyl alcohol, Alkalis. Caution! DEPC is a suspected carcinogen. Always wear gloves and safety glasses. p5

C. Tank and Cassette Preparation 1 Prepare the appropriate amount of transfer buffer (see General Information, page 1). 2 Fill the tank halfway with transfer buffer. 3 Connect the cooling water supply to the tank base hose connectors. Use hose clips to secure the tubing. 4 Add a magnetic stir bar to the tank to maintain uniform temperature and conductivity during electrophoretic transfer. Note: Use gloves when handling the compression cassette components. 5 Pre-wet nitrocellulose or nylon membranes with distilled water. Pre-wet PVDF membranes in methanol. Then soak all membrane types in transfer buffer. 6 Familiarize yourself with the interlocking hinge of the compression cassette. 7 Place the open cassette in a tray filled with transfer buffer so that molecules will migrate toward the membrane (see Figure 1). For negatively charged macromolecules (nucleic acids and most proteins) build the transfer stack on the red half of the cassette. 8 Place a fiber pad on the red half of the transfer cassette and press until all air is expelled. 9 Place a sheet of blotting paper on the fiber pad and then place the membrane on the blotting paper. 10 Place the gel which contains a sample that has been electrophoretically separated and equilibrated (if required) with transfer buffer on the membrane. 11 Use a clean glass rod soaked in transfer buffer to roll out any trapped bubbles between the membrane and gel. 12 Cover the gel with a sheet of blotting paper and then a second fiber pad, again pressing to gently expel any trapped air. 13 Close the cassette and slide the clamping clip into place. p6

Figure 1. Cassette Assembly. Compression cassette Fiber pad Blotting paper Gel Compression cassette Fiber pad Blotting paper Membrane Direction of transfer D. Final Assembly and Transfer 1 Insert the cassette into one of the tank slots with the transfer membrane facing the positive side of the tank. Repeat for all cassettes being used for transfer. 2 Add additional transfer buffer to the tank to reach the max fill line. 3 Place the lid onto the tank and connect the leads to a power supply. 4 Set the voltage and current to suit the transfer application. p7

Ordering Information Product Complete Electroblotting System for 10 10 cm Mini Gels Cat. No. E4103 Replacement parts and accessories: Hinged 10 10 cm cassette with 2 fiber pads E4136 10 10 cm fiber pads, pkg/4 E4137 Complete Electroblotting System for 20 20 cm Standard Gels E4203 Replacement parts and accessories: Hinged 20 20 cm cassette with 2 fiber pads E4236 20 20 cm fiber pads, pkg/4 E4237 p8

Warranty Denville warrants that the unit you have received has been thoroughly tested and meets its published specification. This unit (excluding all accessories) is warranted against defective material and workmanship for a period of twelve (12) months from the date of shipment ex factory. Denville will repair all defective equipment returned during the warranty period without charge, provided the equipment has been used under normal laboratory conditions and in accordance with the operating limitations and maintenance procedures outlined in this instruction manual and when not having been subject to accident, alteration, misuse or abuse. No liability is accepted for loss or damage arising from the incorrect use of this unit. Denville s liability is limited to the repair or replacement of the unit or refund of the purchase price, at Denville s option. Denville is not liable for any consequential damages. Denville reserves the right to alter the specification of its products without prior notice. This will enable us to implement developments as soon as they arise. Denville s products are for research use only. A return authorization must be obtained from Denville before returning any product for warranty repair on a freightprepaid basis. p9

Disposal This equipment is marked with the crossed out wheeled bin symbol to indicate that it must not be disposed of with unsorted waste. Instead it is your responsibility to dispose of your equipment correctly at lifecycle-end by handing it over to an authorized facility for separate collection and recycling. It is also your responsibility to decontaminate the equipment in case of biological, chemical and/or radiological contamination, so that the persons involved in the disposal and recycling of the equipment are protected from any potential hazard. For further information about where you can drop off your waste equipment, please contact your local Denville representative. By doing so, you will help to conserve natural and environmental resources and you will ensure that your equipment is recycled in a manner that protects human health. Thank you p10

Denville Scientific, Inc. P.O. Box 4588 Metuchen, NJ 08840-4588 Toll Free: 1-800-453-0385 Phone: 1-908-757-7577 Fax: 1-908-757-7551 Email: info@densci.com Web: www.densci.com 2011 Denville Scientific, Inc. All rights reserved. Printed in the USA. p11