High Pressure Dryer HLP-MSD 0055 to 0870, PN 100 to PN 400

Similar documents
High Pressure Adsorption Dryer HLP PN 25, 0040 to 0125 HLP PN 40, 0050 to 0155

Technical Data Sheet Page 1 of 5

Kompressoren. Adsorption Dryer AD

ultrafilter HEATLESS HL Adsorption Dryer

ThermoSorb Desiccant Dryers

ultrafilter VARIOBLO Heat Regenerated Adsorption Dryer

Adsorption air dryers ADS 1 215

Desiccant Air Dryers Heatless, Heated and Heated Blower

HYDRYER TYPE P Heat Regenerative Dryers ISO 9001 CERTIFIED

Refrigeration Air Dryers ADQ. Capacity: m 3 /h

Refrigeration Air Dryers. Catalogue

DRYPOINT AC HP PREMIUM HIGH-PRESSURE DRYING

Refrigerated Air Dryers. Catalogue

ZPA Heatless Regeneration ZHA Heated Regeneration ZBA Heated Blower Regeneration

Externally Heated Desiccant Compressed Air Dryers PNEUMATIC PRODUCTS. PHD Series. pneumaticproducts-spx.com

HeatSink TRUE-CYCLING TM REFRIGERATED COMPRESSED AIR DRYERS 150 2,400 SCFM. Independently Verified Performance ( scfm models)

Innovative to the Core

Kompressoren. Compressed Air Filters PF/DF/MF/SF/AF

Concept WVM Brief description. Effi cient compressed-air adsorption dryer with vacuum regeneration. NEW! Now with improved ZDMC2

Filter Housing SG Standard

HR Heated HB Blower. Smart Solutions for Drying Compressed Air. Dual Tower Heat Reactivated Desiccant Air Dryer

Kompressoren. Oil Water Separators OWS

Atlas Copco Compressed air dryers. CD series Heatless adsorption dryer series HIGH QUALITY DRY AIR

ULTRA.DRY HRE Heat Regenerated Adsorption Dryer

TABLE OF CONTENTS. SECTION 1 General Information: Pg 2 Description of Operation

PRICE LIST. 1 st September Service Intervals Preventative Maintenance.

Pro Dry Heatless dessiccant compressed air dryers

On request of Akzo Nobel Dynamo Project Team we ve surveyed the energy efficiency of the compressed air system in the Barcelona Deco & A/AS plant.

clean and quiet dental

Rotary screw compressors kw 5,5 7, , bar MODULO

Refrigeration Compressed Air Dryer Buran Ultrapulse

Ingersoll Rand. Heat-Of-Compression Air Dryers

ThermoStar Refrigeration Air Dryers

4/2-Way Pneumatic Solenoid Valve

Atlas Copco Quality Air Solutions. Compressed Air Filters

CPX/HT Series. REFRIGERATED AND HIGH TEMPERATURE DRYER 12 to 2400 CFM. High-performance products. Designed for you!

BID SPECIFICATION QHD SERIES HEATLESS REGENERATIVE AIR DRYER

Medical Air Systems: Scroll

CONDENSATE MANAGEMENT

Water Separator. Main Line Filter. Mist Separator. Micro Mist Separator 150C 250C 350C 450C AMG 550C 2C 4C 8C 11C AFF 22C 37B 75B 150C 250C 350C 450C

MEDICAL AIR STATIONS FOR MEDICAL GAS PIPING SYSTEM. Key features: NOVAIR quality and service:

DRYPOINT RA REFRIGERATION DRYER RANGE

Compressed air conditioning

SELECT SERIES DHA/CDA HEAT-LES DESICCANT COMPRESSED AIR & GAS PURIFICATION SYSTEMS. Value and Performance Through Advanced Technology

Atlas Copco. On-site Industrial Gases Nitrogen & Oxygen Generators

Series IDU/IDF. Refrigerated Air Dryer

Basic Hydraulics and Pneumatics

In-Line Filters and Coalescers with Automatic Drains

Condensate Treatment Solutions. CTS Series Eliminator II Oil-Water Separators

REFRIGERATED TYPE COMPRESSED AIR DRYERS INSTRUCTION MANUAL. For Sales & Service please contact:

Ultra-Filter. Compressed Air Filter. DF Series

Compressed Air and Gas Drying

Dryaire Desiccant System

Electronic Condensate Drains ECO-DRAIN Series

ROTARY SCREW COMPRESSOR. RMD kw

Atlas Copco Stationary air compressors

VdS en. VdS Guidelines for water extinguishing systems. Non-return valves. Requirements and test methods. VdS en : (01)

REFRIGERATED COMPRESSED AIR DRYERS


TECHNICAL SPECIFICATION. StirLIN-1 Economy Liquid Nitrogen System

SIX REASONS TO DRY BIOGAS To A LOW DEWPOINT BEFORE COMBUSTION IN A CHP ENGINE STEVEN SCOTT MARKET DEVELOPMENT MANAGER ALTERNATIVE ENERGIES

Rotary Screw Compressors SK Series

DHA & DBA Series. Heat Reactivated Desiccant Dryers

ETC -SV. Class 0 oil-free compressed air through catalysis

CONTINUOUS FLOW BREATHING AIR PURIFIERS

Service Catalog False economy, can cost you dearly!

BOEING CANADA WINNIPEG RECOGNIZED FOR COMPRESSED AIR PROJECT

GAS HANDLING SYSTEMS VACUUM INSTRUMENT CORPORATION

CNG / CBG. your high pressure solution. compressors for turn-key refuelling stations. CNG/CBG

Backflush filter R8-30W

CoolTop. A unique water cooled air-conditioning unit for server room cooling from the top AC-TOPx-CW-240/60

Compressor Service & Maintenance Manual

Automatic Bypass Control AVDO

Meeting Your Compressed Air Treatment Needs

How To Remove A Large Particle From A Large Tank

Valve systems Base plates, according to standard ISO Brochure

Laboratory Gas Generators. LABGAS Pure & Simple

Valve Proving System VPS 504 Series S06 (120 VAC) Series S05 (24 VDC)

OPERATING AND MAINTENANCE MANUAL

Portable Compressors MOBILAIR M 270 With the world-renowned SIGMA PROFILE Free air delivery 20.0 to 26.9 m³/min.

Type 3353 Angle Seat Valve

Owners Manual. Refrigerated Air Dryer. HX75 thru HX2400

Heavy Fuel Oil supply units. The world s best selling HFO supply unit. The right choice for any conditions

Thermostatic valve Type AVTA

Nirvana. Cycling Refrigerated Dryers

AIRROLLAIR COMPRESSORS E

PRESSURE REDUCING VALVES

OIL-X EVOLUTION Compressed Air Filters ENGINEERING YOUR SUCCESS. TECNI-AR Ltda - Tel: w.tecni-ar.com.br

Atlas Copco Industrial Aluminium Piston Compressors. L Series Oil-lubricated & oil-free ( kw / 2-20 hp)

FUTURE AIR SOLUTIONS OIL FREE SCROLL COMPRESSORS

Compressed Air Filters KAESER FILTER Flow rate 0.60 to m³/min

Compressed Air Filters

Vacuum drying oven for non-flammable solvents

AdSORPTION CHILLER NAK

Membrane air dryers MS-LDM1, MS series

Refrigeration Dryers SECOTEC Flow rate 0.6 to 14.3 m³/min

Control blocks for two-hand start ZSB

Air Eliminators and Combination Air Eliminators Strainers

BLASTING SYSTEMS. Turbine blasting systems. Air blasting systems. Automatic Painting plants

EASIDEW PORTABLE HYGROMETER INSTALLATION, OPERATION AND MAINTENANCE MANUAL

Transcription:

Technical ata Sheet Page 1 of 6 igh Pressure ryer -MS 0055 to 0870, PN 100 to PN 400 igh pressure adsorption dryer, heatless regenerating, pre-, and afterfilter included Compressed air is lead through the inlet of the dryer () and across the prefilter (3) t this stage, the air is cleaned from particles and condensate The condensate is removed via a manually operated drain (5) or optional via a automatic condensate drain (16) Via a 4/2-way ball valve (1), the air is lead into the adsorption vessel (1), in which the air is dried down to the required pressure dewpoint Via a non-return valve (7), the air is let into an afterfilter (4), in which possibly released particles from the desiccant are retained Via the outlet (), the clean and dry air is lead into the compressed air network and to the point of use While one vessel is in the drying phase (adsorption), the other vessel is being dried again (regeneration) Regeneration of the moisture-laden desiccant is achieved with a partial flow of the dried medium t the start of regeneration, the 4-way ball valve (2) is switched to the position depressurizing n this way the adsorber is brought down to atmospheric pressure The compressed air passes out of the system through the silencer (10) n the 2nd step the 2-way ball valve is opened partial flow of the dried medium flows through a bypass in the upper piping and through the regenerating adsorber out to the atmosphere across a silencer (10) 3 5 1 162 161 16 ption automatischer automatic ondensatableiter condensate ption automatic drain condensate drain o 11 P 01 7 P 02 8 8 9 2 2 1 1 2 2 6 XX2 o XX1 2 10 1 XX2 7 3 igh pressure adsorption dryer L-MS 11 4 141 153 152 bei PN400 152 152 at at PN PN400 400 15 142 ption ption Steuerluft-ruckminderer 14 Control ption Control air air-pressure - Pressure reducer reducer 152 MT 101 151 tmosphere tmosphäre atmosphere ption Superplus Ultraconomy Ultraconomy incl inkl ption Steuerluft-ruckminderer Control incl ption air Control - Pressure air-pressure reducer reducer Control Steuerluft Control air air 1 M 02 101 M 01 101 Technical alterations reserved (R05/ 2007/04/24) onaldson iltration eutschland mb ndustrial iltration Solutions üssingstraße 1-42781 aan Telefon +49/2129/569-0 Telefax +49/2129/569-100

Technical ata Sheet Page 2 of 6 PN 100 - PN 400 eatures PN 100-400 Complete purification package including pre-, afterfilter and hand operated drain (optional automatic condensate drain) ptimally dimensioned filters ndication of operating status (adsorption, regeneration, pressurizing, service, alarm) via L display ntermittend operation as standard Use of pneumatically controlled seat valves enefits Turnkey-system; all components from one hand, technically perfectly matched to each other Safe separation of particle and aerosols (on adherence to the specified parameters), large filter surface causes low differential pressure of the unit, thereby low operating cost igh operating safety, all operating status can be easily detected at any time Coupling with the compressor with central applications possible, thus savings of regeneration air and operating cost igh operating safety, low pressure losses, low operating and maintenance costs Product description: Complete purification package with heatless adsorption dryer which works on the basis of pressure swing adsorption nclusive pre-, afterfilter, optional automatic condensate drain Medium: Compressed air/ nitrogen Pressure dewpoint: - 40 C at 100% load option package available lexibility in application; option package for economic and safe system integration in the compressed air network - dew point-dependent capacity control - automatic condensate drain - control air supply - starting valve perating pressure: PN 100: min 41 bar (ü), max 100 bar (ü) PN 250: min101 bar (ü), max 250 bar (ü) PN 400: min251 bar (ü), max 400 bar (ü) Medium temperature: PN 100 Volume flow in m 3 /h (1 bar, 20 C)* Regeneration air losses (average) m 3 /h (1 bar, 20 C) Volume flow out (min) m 3 /h (1 bar, 20 C) Pressure loss initial mbar 0055 55 2,2 52,3 80 0110 110 4,4 104,4 165 0185 185 7,3 175,5 430 0370 370 12,9 354,4 795 0655 655 21,6 629,8 860 PN 250 Volume flow in m 3 /h (1 bar, 20 C)* Regeneration air losses (average) m 3 /h (1 bar, 20 C) Volume flow out (min) m 3 /h (1 bar, 20 C) Pressure loss initial mbar 0090 90 3,8 85,4 90 0195 195 7,8 185,7 225 0310 310 12,3 295,2 560 0600 600 23,8 571,8 1120 1050 1050 41,2 1000,9 1320 min 5 C, max 55 C mbient temperature: min 4 C, max 50 C Power supply: 230 V/ 50-60z optional 115 V/ 50-60z 24 V C Power consumption: approx 40 W PN 400 Volume flow in m 3 /h (1 bar, 20 C)* Regeneration air losses (average) m 3 /h (1 bar, 20 C) Volume flow out (min) m 3 /h (1 bar, 20 C) Pressure loss initial mbar 0115 115 5,1 108,4 220 0215 215 9,3 203,2 630 0320 320 14,0 302,8 450 0500 500 22,3 472,0 1015 0870 870 38,0 822,9 885 esign, manufacture, testing dsorber and filter: acc to RL 97/23/ eclaration of conformity: acc to RL 97/23/ * related to 1 bar (abs) and 20 C at intake of compressor and 7 bar system pressure and 35 C inlet temperature into dryer

Technical ata Sheet Page 3 of 6 PN 100 - PN 400 Sizing PN 100: PN 100 xample: nlet temperature V nom = 65 m 3 /h, nlet temperature = 40 C perating pressure = 85 bar (ü) Pressure dewpoint = -40 C perating pressure (bar) 45 50 55 60 65 70 75 80 85 90 95 100 30 C 0,48 0,53 0,58 0,63 0,69 0,74 0,79 0,84 0,89 0,95 1,00 1,05 35 C 0,46 0,50 0,55 0,60 0,65 0,70 0,75 0,80 0,85 0,90 0,95 1,00 40 C 0,36 0,39 0,43 0,47 0,51 0,55 0,59 0,63 0,66 0,70 0,74 0,78 45 C 0,28 0,31 0,34 0,37 0,40 0,43 0,46 0,49 0,52 0,55 0,58 0,61 50 C 0,22 0,24 0,27 0,29 0,31 0,34 0,36 0,38 0,41 0,43 0,46 0,48 55 C 0,17 0,19 0,21 0,23 0,25 0,27 0,29 0,30 0,32 0,34 0,36 0,38 V corr = V nom f 65 m 3 /h = = 0,66 98,5 m 3 /h Selected adsorption dryer: 0110 - PN100 Sizing PN 250: PN 250 xample: nlet temperature V nom = 80 m 3 /h, nlet temperature = 40 C perating pressure = 200 bar (ü) Pressure dewpoint = -40 C perating pressure (bar) 110 120 130 140 150 160 170 180 190 200 210 220 230 240 250 30 C 0,46 0,51 0,55 0,59 0,63 0,67 0,72 0,76 0,80 0,84 0,88 0,92 0,97 1,01 1,05 35 C 0,44 0,48 0,52 0,56 0,60 0,64 0,68 0,72 0,76 0,80 0,84 0,88 0,92 0,96 1,00 40 C 0,34 0,38 0,41 0,44 0,47 0,50 0,53 0,56 0,59 0,62 0,66 0,69 0,72 0,75 0,78 45 C 0,27 0,29 0,32 0,34 0,37 0,39 0,42 0,44 0,46 0,49 0,51 0,54 0,56 0,59 0,61 50 C 0,21 0,23 0,25 0,27 0,29 0,31 0,33 0,35 0,37 0,38 0,40 0,42 0,44 0,46 0,48 55 C 0,17 0,18 0,20 0,21 0,23 0,24 0,26 0,27 0,29 0,30 0,32 0,33 0,35 0,36 0,38 V corr = V nom f 80 m 3 /h = = 0,62 129 m 3 /h Selected adsorption dryer: 0195 - PN250 Sizing PN 400: PN 400 xample: nlet temperature V nom = 290 m 3 /h, nlet temperature = 40 C perating pressure = 350 bar (ü) Pressure dewpoint = -40 C perating pressure (bar) 250 275 300 325 350 375 400 30 C 0,66 0,72 0,79 0,85 0,92 0,98 1,05 35 C 0,63 0,69 0,75 0,81 0,88 0,94 1,00 40 C 0,49 0,54 0,59 0,63 0,68 0,73 0,78 45 C 0,38 0,42 0,46 0,50 0,53 0,57 0,61 50 C 0,30 0,33 0,36 0,39 0,42 0,45 0,48 55 C 0,24 0,26 0,29 0,31 0,33 0,36 0,38 V corr = V nom f 290 m 3 /h = = 0,68 426,5 m 3 /h Selected adsorption dryer: 0500 - PN400

C Technical ata Sheet Page 4 of 6 0055-0655, PN 100 N 1/4 o PN 100 Connection N C 0055 1/4 1245 590 500 650 410 485 390 550 500 13 0110 3/8 1385 615 500 650 420 490 390 575 505 13 0185 3/8 1435 650 500 750 430 505 390 610 520 13 0370 1/2 1830 730 580 860 485 560 445 690 580 17 0655 3/4 1875 820 580 930 520 590 445 780 625 17

C Technical ata Sheet Page 5 of 6 0090-1050, PN 250 N 1/4 o PN 250 Connection N C 0090 1/4 1280 570 500 650 405 480 390 530 495 13 0195 3/8 1340 615 500 630 420 495 390 575 505 13 0310 3/8 1300 670 500 610 440 510 390 630 515 13 0600 1/2 1755 730 580 850 485 560 445 685 580 17 1050 3/4 1890 835 580 940 520 595 445 795 640 17

C Technical ata Sheet Page 6 of 6 0115-0870, PN 400 N 1/4 o PN 400 Connection N C 0115 1/4 1205 590 500 620 410 485 390 550 500 13 0215 3/8 1275 605 500 625 420 495 390 565 490 13 0320 3/8 1330 660 500 650 430 505 390 620 525 13 0500 1/2 1470 730 580 745 485 560 445 690 580 17 0870 3/4 1540 835 580 790 520 595 445 795 640 17