Thermocouple Thermometer Models

Similar documents
Thermistor Thermometer MODEL NO

Thermocouple Thermometer

Barnant Company THERMOCOUPLE THERMOMETER. Dual J-T-E-K MODEL NO Barnant Company

Instruction Manual Temp 4/5/6 Temperature Meter Series

Manual Ranging MultiMeter

AutoRanging Digital MultiMeter

Temperature Humidity Meter

Hygro-Thermometer + InfraRed Thermometer Model RH101

Microwave Meter. Instruction Manual

10 Multimeter. Users Manual

HVAC Clamp Meter. Users Manual

EPM3. Phase Sequence and Motor Rotation Tester. Users Manual

Model UT33A: OPERATING MANUAL Table of Contents (1)

12 Volt 30 Amp Digital Solar Charge Controller

Ground Resistance Clamp On Tester

Ground Resistance Clamp-On Tester

62 Max/62 Max + Infrared Thermometer

Instruction Manual HI Refractometer for Refractive Index and Brix Measurements

Model UT201/202: OPERATING MANUAL. Table of Contents

Instant Ear Thermometer

RS DIGITAL THERMOMETER

Model HPX10 Series Automatic Battery Charger User s Manual Rev. 1.0 October 17, 2006

User s Manual Before using the inverter, you need to read and save the safety instructions.

Dual Laser InfraRed (IR) Thermometer

Instructions A Amp AC/DC Current Probe

Dual Laser InfraRed (IR) Thermometer

The table below lists the symbols used on the Clamp and/or in this manual. Important Information. See manual.

EM90 INFRA-RED THERMOMETER & THERMOCOUPLE METER

Milwaukee USER MANUAL. Milwaukee. Smart DO Meter PORTABLE DISSOLVED OXYGEN METER MODEL: SM600. Authorized Dealer: ISMIL600 11/01

Rosemount 5300 and 5400 Series Terminal Compartment Spare Part Instruction

ExStik TM ph Waterproof Meters

Instruction Manual ph 5+ ph 6+ Ion 6+ Technology Made Easy...

Model 1756 Test Lead Kit

Milwaukee USER MANUAL

Dual Laser InfraRed (IR) Thermometer with Color Alert

Pocket Tach 99 (PT99) Non-Contact Tachometer

How To Use A Cdm250 Digital Multimeter

IDEAL INDUSTRIES, INC. TECHNICAL MANUAL MODELS:

User's Guide. True RMS Industrial Multimeter

7 FUNCTION DIGITAL MULTIMETER

INSTRUCTION MANUAL. NC-500 NETcat Pro Wiring Tester

BC-5000 OPERATIONS MANUAL BATTERY CAPACITY TESTER COFKO LLC.

digital fever alert ear thermometer suitable from birth instruction manual

Instruction Manual HI Refractometer for Sucrose Measurements

OPERATOR S MANUAL 18 VOLT, 1 HOUR CHARGER

Auto-ranging Digital Multimeter INSTRUCTION MANUAL

User Guide. 4 wire Earth Resistance Tester Model GRT300

Ultrasound Technologies. PD1v. vascular pocket doppler. Operating Instructions

IN-OUT Thermometer with Cable Free Sensor and Clock

UT202A Operating Manual. Contents

323/324/325. Calibration Manual. Clamp Meter

el-720 Carbon Dioxide Gas Leak Detector User s Guide

Operating Instructions Bedienungsanleitung Mode d'emploi Instrucciones de manejo Istruzioni d'uso

Seven function digital multimeter

Model RPM10 Laser Photo / Contact Tachometer with IR Thermometer Patented

RomiApex A-15. APEX LOCATOR User Manual

User's Manual. Heavy Duty Dissolved Oxygen Meter Model

User s manual FLIR VP50/VP52 Non-contact AC voltage detector

Instruction Manual. T3111 T3111L T3111P T3111Ex

Instant Ear Thermometer

1. SAFETY INFORMATION

DX-395. FM/AM/SW1/SW2 PLL Synthesized Receiver OWNER S MANUAL. Cat. No Please read before using this equipment.

MAP COFFEE MIA CAPSULE COFFEE MACHINE INSTRUCTION MANUAL MODEL: CM4725. Read this manual thoroughly before using and save it for future reference

User Guide. Model Insulation Tester / Megohmmeter

Instruction Manual HI Portable Waterproof Microprocessor Dissolved Oxygen Meter

EzFlex Combustible Gas Leak Detector Model EZ40

CO-220 Carbon Monoxide Meter

aseries A13B Mini Bullet Camera User Manual

Wireless Indoor/ Outdoor Thermometer

Owner s Manual

INSTRUCTION MANUAL Contactless Clinical Infrared Thermometer GT-101

ELECTRONIC THERMOSTAT AND THERMOMETER With SPEED CONTROL

REMOTE TERMOMETER TE 219 LED USER MANUAL

TABLE OF CONTENTS 11.0 WARRANTY

User Guide. Heavy Duty Dissolved Oxygen Meter. Model

Integrating Sound Level Meter and Datalogger

How To Use The Visifault Visual Fault Locator

RS Stock No Instruction Manual RS-1340 Hot Wire Anemometer

XP Series Balances Operation Manual

K Standard Grade Ni-Cr vs Ni-Al (Chromel vs Alumel)

804 Ti Stand. Manual EN

Global Water Instrumentation, Inc.

Model 349KLX Remote Display Digital Scale User Instructions

Model UT33B/C/D: OPERATING MANUAL Table of Contents (1)

User Guide. ExStik TM ph (PH100 & PH110) and ORP (RE300) Waterproof Series Pens. Patent Pending

162 CB CABLE TRACER. Filter Probe & Tone Generator INSTRUCTION MANUAL

G670 Intermittent Pilot Ignition Controls

4.3-inch Back-Up Camera

TC-9102 Series Surface Mount Temperature Controllers

DSM155 Digital LED Light Meter User s Manual DSM155

Model UT713 OPERATING MANUAL

User's Guide. Digital Psychrometer. Model RH390. F C WBT Dew Point MAX MIN

FLUORESCENT UV- RING LIGHT OPERATING INSTRUCTION

How To Use A Meter

Wide Range InfraRed (IR) Thermometer with Type K input and Laser Pointer

High Temperature InfraRed Thermometer with Laser Pointer

OPERATION MANUAL. Pen type, separate electrode SOIL PH METER Model : PH-220S

Transcription:

Technology Made Easy... Thermocouple Thermometer Models 60010-00 (Type J) 60010-10 (Type K) 60010-20 (Type T) 68X309905 Rev 1 04/04

TABLE OF CONTENTS 1. INTRODUCTION 4 2. SAFETY PRECAUTIONS 6 3. SPECIFICATIONS 7 4. BATTERY INSTALLATION AND REPLACEMENT 10 5. SELF TEST 12 6. CONNECTING A THERMOCOUPLE 12 7. SELECTING TEMPERATURE SCALE 16 8. HOLD FUNCTON 17 9. CALIBRATION 17 10. CANCELING A FIELD CALIBRATION 18 11. FIELD CALIBRATION LOCKOUT AND RE-ENABLE 19 12. LOCKOUT PROCEDURE 19 13. RE-ENABLE PROCEDURE 20 14. MAINTENANCE 20 15. CLEANING 21 16. BATTERIES 21 17. ACCESSORIES 22 18. SERVICE 24 19. WARRANTY 25 20. PRODUCT RETURN 25

1. INTRODUCTION This versatile hand-held instrument provides highly accurate temperature measurements. The instrument is designed for easy operation and includes the following features: Operator selection of Celsius or Fahrenheit scale Resolution of 0.1 from 99.9 to 299.9 Four-digit LCD Hold feature for temporarily retaining a reading Field calibration capability 4

Low battery warning Built-in tilt stand for easy hands-free operation Two blade female ANSI miniconnector input Operates with a wide selection of probes 2 5

2. SAFETY PRECAUTIONS WARNING: THIS INSTRUMENT IS DESIGNED TO ACCEPT LOW LEVEL SIGNALS SUPPLIED BY STANDARD THERMOCOUPLES. UNDER NO CIRCUMSTANCES SHOULD THE INPUT VOLTAGE EXCEED THE SPECIFIED 50V RMS. CAUTION: DO NOT USE OR STORE THIS INSTRUMENT IN MICROWAVE OVENS OR ANY ABNORMALLY HOT OR COLD AREAS. CAUTION: WEAK BATTERIES SHOULD NOT BE LEFT IN THE INSTRUMENT. DEAD BATTERIES CAN LEAK AND CAUSE DAMAGE TO UNIT. DANGER: VOLTAGES PRESENT AT THE THERMOCOUPLE MAY ALSO BE PRESENT AT THE BATTERY TERMINALS. ALWAYS DISCONNECT THE THERMOCOUPLE WHEN CHANGING BATTERIES. WARNING: TO PREVENT IGNITION OF A HAZARDOUS ATMOSPHERE, BATTERIES MUST ONLY BE CHANGED IN AN AREA KNOWN TO BE NON-HAZARDOUS. 6

3. SPECIFICATIONS THERMOCOUPLE PROBES Type Temperature range Type J 200 C to 1000 C ( 328 F to 1832 F ) Type K 250 C to 1372 C ( 418 F to 2501 F ) Type T 250 C to 400 C ( 418 F to 752 F ) Out of range display: - - - - Resolution 0.1 /1 autoranging, 0.1 from 99.9 to 299.9, 1 outside this range. Accuracy > 99.9 : +(0.2% of reading +0.5 C) +(0.2% of reading +0.9 F) < 99.9 : +(0.25% of reading, +1 C) +(0.25% of reading +2 F) Display 4-digit LCD with 0.5 in high numerals. Display update rate 0.6 sec per update. Input One thermocouple with ANSI connector. 7

Input Protection 50V rms Battery Two AA, 1.5V alkaline ANSI-L40, IEC- LR6. Battery Life: 750 hours continuous, typical. Low battery indication Battery Symbol on when 8 to 10 hours of battery life remains. Battery symbol blinking: replace battery Operating Conditions Stated accuracy: 18 C to 28 C (64 F to 82 F) Useful range: 0 C to 40 C (32 F to 104 F) Storage: 40 C to 65 C ( 40 F to 149 F) Humidity (non-condensing): 10% to 90% 4 Dimensions 3 cm D x 8.4 cm W x 15.8 cm H (1.2 in x 3.3 in x 6.2 in) Weight with batteries 227 grams (8 ounces) 8

Ingress protection Meets IEC-529 IP-54 for dust and water resistant enclosures. Intrinsic safety This product is energy limited for intrinsically safe operation in hydrogen atmospheres per Class I, Division 1, Groups A, B, C and D hazardous(classified) locations for UL per UL913 and CSA per C22.2 No. 0- M1982 and No. 157-M1987. Maximum surface temperature: 135 C (T4); UL file No. E182612 (1997). Electromagnetic Compatibility (For CE Mark) EN61326-1/1A: 1998 (EU EMC Directive) 9

4. BATTERY INSTALLATION AND REPLACEMENT If battery indicator turns on, battery life is approximately 8 to 10 hours. The battery indicator will start blinking with less than 1 hour of life remaining. Selected settings are stored in memory and will remain in memory even after power is turned off, or while batteries are being replaced. 1. Before changing battery, turn instrument off and disconnect thermocouple. 2. Loosen screw and lift battery cover off back of case. 3. Remove the two AA batteries. 4. Insert two new batteries observing polarity. 5. Install cover and tighten screw. 10

CAUTION: WEAK BATTERIES SHOULD NOT BE LEFT IN THE INSTRUMENT. DEAD BATTERIES CAN LEAK AND CAUSE DAMAGE TO UNIT. DANGER: VOLTAGES PRESENT AT THE THERMOCOUPLE MAY ALSO BE PRESENT AT THE BATTERY TERMINALS. ALWAYS DISCONNECT THE THERMOCOUPLE WHEN CHANGING BATTERIES. WARNING: TO PREVENT IGNITION OF A HAZARDOUS ATMOSPHERE, BATTERIES MUST ONLY BE CHANGED IN AN AREA KNOWN TO BE NON-HAZARDOUS. 11

5. SELF TEST Press the ON/OFF key. The thermometer performs a self-test and all display digits and indicators, as shown below, should remain on for approximately one second. 6. CONNECTING A THERMOCOUPLE Use the correct thermocouple type for your instrument. Using an incorrect thermocouple type will result in erroneous readings. Thermocouples are colour coded by type using the North American ANSI Color Code as follows: TYPE J K T COLOR Black Yellow Blue Thermocouple connectors have one wide blade and one narrow blade. Do not force connector in backwards. Connect thermocouple to receptacle at top of instrument as shown in the following illustration. 12

Thermocouple wiring polarity must be correct. If readings decrease as the temperature increases, the thermocouple wires may be reversed. The red wire is negative for thermocouple wires manufactured in North America. 13

14

15

If a thermocouple is not connected or if the thermocouple is defective, the display will indicate OPEn. Thermocouples are sensitive at the tip or measuring junction. When taking measurements, allow time for the reading to stabilize. Multiplying the time constant of the probe by 5 will give you the approximate time required. 7. SELECTING TEMPERATURE SCALE Select C or F by pressing the C/ F key. Each time the key is pressed the temperature scale will switch. Switching between C and F can be done at any time during operation. Each time you turn the instrument on, it will power up with the same settings that were set when the unit was last turned off. 16

8. HOLD FUNCTON Press the HOLD key to retain the reading on the display. Press the HOLD key again for normal operation. 9. CALIBRATION The thermometer is factory calibrated and does not require calibration before use. The CAL function allows single point calibration of the thermometer, at 0 C (32 F) to compensate for thermocouple off-set error. It is not necessary to perform a field calibration to obtain specified meter accuracy. Use the field calibration feature to improve thermometer/probe accuracy or to compensate for thermocouple drift.. 1. Pack sensing end of probe in a container tightly packed with crushed ice and filled with distilled water. Allow temperature to stabilize. 2. Press and hold the CAL key for 5 seconds to enter the calibration mode, the CAL annunciator on the display starts blinking. Release the CALkey. 3. If the measured temperature is from _10 C to10 C (14 to 50 F), when the 17

temperature reading is stable, press the CAL key. The CAL indicator will stop blinking and the reading will be set to 0 C (32 F). The CAL indicator will remain turned on, indicating a field calibration is active. If Err is displayed, either the displayed reading is outside the above limits or the batteries are weak. 10. CANCELING A FIELD CALIBRATION 1. Turn the thermometer off. 2. Hold the CAL key down while pressing the ON/OFF key. The field calibration is canceled and the thermometer reverts to the default factory calibration. The CAL annunciator is now turned off. 18

11. FIELD CALIBRATION LOCKOUT AND RE-ENABLE The calibration lockout feature prevents any field calibration changes. The lockout remains in effect until a lockout re-enable has been performed. Use the following procedures to lockout or re-enable the field calibration operation. 12. LOCKOUT PROCEDURE 1. Turn the thermometer off. 2. Simultaneously press and hold the CAL and the C/ F keys down and momentarily press the ON/OFF key. Continue to hold the CAL and C/ F keys for at least 5 seconds. 19

13. RE-ENABLE PROCEDURE 1. Turn the thermometer off. 2. Simultaneously press and hold the HOLD and the CAL keys down and momentarily press the ON/OFF key. Continue to hold the HOLD and CAL keys until the display blanks. 14. MAINTENANCE Properly used, the thermometer should maintain calibration indefinitely and not require service other than occasional cleaning of the housing and changing of the batteries. 20

15. CLEANING WARNING: TO PREVENT IGNITION OFA HAZARDOUS ATMOSPHERE BY ELECTROSTATIC DISCHARGE,CLEAN WITH DAMP CLOTH. Do not clean with abrasives or solvents. Use mild detergents, never immerse nor use excessive fluid. 16. BATTERIES If there is no display when the thermometer is turned on, check condition of the two AA batteries. Also check that the battery terminals are clean and batteries are properly installed. If replacement is necessary, refer to the BATTERY INSTALLATION AND REPLACEMENT section for replacement procedure. 21

17. ACCESSORIES Replacement Meter and Meter Accessories Item Ordering Code Type J 60010-00 Type K 60010-10 Type T 60010-20 Soft carrying case 08520-05 Replacement AA batteries, pack of 4 Certificate of Calibration 09376-01 Call for part number Traceable to NIST 22

General purpose probe (immersion Into liquids), type J Penetration probe (meat, semi-soft Materials), type J Surface probe (direct contact on Hot surfaces), type J Clip-on probe (surface contacts- Electronics), type J General purpose probe (immersion Into liquids), type K Penetration probe (meat, semi-soft Materials), type K Surface probe (direct contact on Hot surfaces), type K Clip-on probe (surface contacts- Electronics), type K EC-TPGLPJ- 01M/ 08517-55 EC-TPPENJ- 01M/ 08517-65 EC-TPSURJ- 01M/ 08517-60 EC-TPCLPJ- 01M/ 08469-00 EC-TPGLPK- 01M/ 08516-55 EC-TPPENK- 01M/ 08516-65 EC-TPSURK- 01M/ 08516-60 EC-TPCLPK- 01M / 08469-02 23

18. SERVICE WARNING SUBSTITUTION OF COMPONENTS MAY IMPAIR INTRINSIC SAFETY. There are no internal adjustments or user replaceable parts. If Err followed by the numbers 1 through 9 is displayed (see example below) return unit for service. Note that Err alone may be displayed during improper field calibration. Note: Serial number label is located inside battery compartment. 24

19. WARRANTY The Manufacturer warrants this product to be free from significant deviations from published specifications for a period of three years. If repair or adjustment is necessary within the warranty period, the problem will be corrected at no charge if it is not due to misuse or abuse on your part as determined by the Manufacturer. Repair costs outside the warranty period, or those resulting from product misuse or abuse, may be invoiced to you. 20. PRODUCT RETURN To limit charges and delays, contact the seller or Manufacturer for authorization and shipping instructions before returning the product, either within or outside of the warranty period. When returning the product, please state the reason for the return. For your protection, pack the product carefully and insure it against possible damage or loss. Any damages resulting from improper packaging are your responsibility. 25

NOTES

TECHNICAL ASSISTANCE If you have any questions about the use of this product, contact the Manufacturer or authorized seller. Trademarks bearing the symbol in this publication are registered in the U.S. and in other countries. For more information on Eutech Instruments/ OAKTON Instruments products, contact your nearest distributor or visit our web site listed below: Eutech Instruments Pte Ltd Blk 55 Ayer Rajah Crescent #04-16 Singapore 139949 Tel: (65) 6778 6876 Fax: (65) 6773 0836 Website: www.eutechinst.com Email: marketing@eutechinst.com OAKTON Instruments P.O. Box 5136 Vernon Hills, IL 60061, USA Tel (in U.S.): 888-462-5866 Tel (outside U.S.) 1-847-549-7600 Website: www.4oakton.com E-mail: info@oakton.com Fax: (1) 847-247-2984 Distributed by: