FIXED DISPLACEMENT HYDRAULIC VANE PUMPS BQ SERIES

Similar documents
FIXED DISPLACEMENT HYDRAULIC VANE PUMPS BQ SERIES

FIXED DISPLACEMENT HYDRAULIC VANE PUMPS BQ SERIES

Variable Displacement Pump AA10VSO

Fixed displacement vane pumps

PUMP AND MOTOR DIVISION

SCP ISO. Other advantages: SCP ISO is a series of piston pumps with a fixed displacement for mobile and stationary hydraulics.

Series PVP Variable Volume Piston Pumps

Mobile Hydraulic Pumps T6*M. Denison Vane Technology, fixed displacement

VARIABLE DISPLACEMENT AXIAL PISTON PUMPS. For truck applications

Series TMM Axial Piston Motor. Technical Information

Vickers Vane Pumps Single and Double Vane Pumps. Model Series V10, V20, V2010, and V2020 for Industrial Equipment

Vane Pump & Motor Design Guide

Hydraulic Motor/Pump. Series F11/F12 Fixed Displacement. parker.com/pmde

VHO/VQ Single, Double & Triple Vane Pumps

PVH131/141 Variable Displacement Piston Pump - 11 Design


Rexroth Hydraulic Pump A10VO Series User Manual

Extremely compact in size to allow direct flange-mounting on vehicle engine or gearbox PTOs.

Rickmeier Solutions. Gear pumps for superior Lubrication

Unit 24: Applications of Pneumatics and Hydraulics

USA Headquarters. Dynex/Rivett Inc. 770 Capitol Drive Pewaukee, WI U.S.A. Tel: FAX:

A10VSO Nominal size 18 see RD A10VSO Nominal size see RD 92711

Unit 24: Applications of Pneumatics and Hydraulics

Table of Contents. M Series Variable Displacement Piston Pumps

Radial piston pumps type R and RG

P2/P3 Series Piston Pumps Variable Displacement zp09. Catalog HY CD/US

Truck Hydraulics. Series GPA, GP1, F1, F2, T1, VP1, Fixed and Variable Displacement Pumps, Motors and Accessories. parker.com/pmde

Steering unit. Table of contents. Features RE 11872/ Type LAGL. Frame sizes 500 to 1000 Component series 1X Maximum flow 80 l/min

Vickers Vane Pump & Motor Design Guide For Mobile Equipment

BOWIE PUMPS OPERATION - MAINTENANCE

3-Way heavy duty flow control, with pressure compensated and solenoid controlled priority flow

PM10 VARIABLE DISPLACEMENT PUMP CLOSED LOOP CIRCUIT

Truck Hydraulics. Series GPA, GP1, F1, F2, T1, VP1, Fixed and Variable Displacement Pumps, Motors and Accessories

HYDRAULIC MOTORS HYDRAULIC SYSTEMS DIVISION. Outstanding Hydraulic Products, Service and Expertise, Worldwide

Truck Hydraulics. F1 F2 T1 VP1 PTO info Accessories. Fixed and Variable Displacement Pumps, Motors and Accessories. Catalogue HY /UK March 2004

Hydraulic Pump/Motor Division Hydraulic Pump/Motor Division

Pressure Relief. Pressure Control Valve R(C)G(O)-03, 06 and 10; R(C)T(O)-03, 06 and 10 VICKERS. Basic Characteristics. Sectional Illustrations

Series PAVC Variable Displacement Piston Pumps zp01. Catalog HY CD/US

PVM Piston Pumps Service Manual

Vickers. Piston Pumps

2-Way heavy duty flow control, with pressure compensated, solenoid and load sensing controlled priority flow

300 Series PA Pump and Cooler Assemblies

Vickers Vane Pumps V Series - Low Noise Vane Pumps. High Performance Intravane Pumps For Industrial Applications

Vickers PVM Piston Pumps

Q Series Piston Pumps Variable Displacement, Quiet Series for Industrial Applications

Eurovacuum EV Series. Single Stage Oil Sealed Rotary Vane Pump

QPM3 Low pressure pump for circulation of oil in hydraulic and lubricating systems

*Rated to 207 Bar/3000 PSI with Aluminum Body. Denotes New Winner s Circle Product Line. Catalog HY /US

H1 Axial Piston Pump, Size 078, Single Technical Information Dimensions

Vickers. Overhaul Manual. Vane Motors. Vane Motors. 25M, 35M, 45M, 50M Series -20 Design

Flow Control Valves. Note: Also see R04C3 on page DC1. Denotes New Winner s Circle Product Line. Catalog HY /US

Vickers. Overhaul Manual. Steering. Power Steering Pumps. VT16 & VT17 Series

1.Booklet. Hydraulic Motors. General Purpose MotorsR Series

Pumps: Convert mechanical energy (often developed from electrical source) into hydraulic energy (position, pressure and kinetic energy).

Pressure reducing valve, direct operated, Type ZDR 6 D

ZOP, ZOT SIGMA PUMPY HRANICE GEAR PUMPS

Internal gear pump PGF Series 2X and 3X

Dual Path Mobile Pump

PART 2 FORKLIFT HYDRAULIC SYSTEM

Design and Modeling of Fluid Power Systems ME 597/ABE 591 Lecture 5


Vertical selfpriming Side-Channel Pumps Type WPV

PVQ 40-B2/M2 * *** - ** * * - 10 C** *** *** * - 10/11/12/20 PVQ 45-B2/M2 * *** - ** * * - 10 C**

Vickers. Check Valves. Check Valves. Inline, right angle, manifold mounted, and pilot operated designs. Released 9/93

Rotary screw compressors kw 5,5 7, , bar MODULO

HOW THE CONTAMINATION IS MEASURED CONTAMINATION CLASSES ACCORDING TO ISO 4406:1999

220 Series Piston Pump Typical Applications Features and Benefits

Mechanical shaft seal types and sealing systems

E4E PILOT OPERATED DIRECTIONAL CONTROL VALVE WITH ELECTRIC PROPORTIONAL CONTROL SERIES 51

High Torque Vane Motors MV015, MV037, MV057, MV125

ECOCIAT. Domestic hot water heat recovery unit

Reusable contamination basket prevents loss of retained contaminants into the reservoir during element replacement.

NORMAN FILTER COMPANY PRODUCT OVERVIEW

Maintenance and Service Instruction

HYDRAULIC MOTORS Concentric AB

VERTICAL TURBINE AND PROPELLER PUMPS

MONO BLOCK DIRECTIONAL CONTROL VALVE TS1120TSLB

COUNTERBALANCE VALVES

Check Valves Valve locator

BSM MOTOR DRIVEN CENTRIFUGAL PUMPS

Delta Power Company 4484 Boeing Drive - Rockford, IL 61109

Hydraulic Control Solutions

BoWex SD, SD1 and SD2 Operating-/Assembly Instructions

ROTEX SD shiftable jaw coupling

Air Eliminators and Combination Air Eliminators Strainers

HMC Series Dual Displacement Staffa Motor

Hydraulic Trouble Shooting

*Rated to 207 Bar/3000 PSI with Aluminum Body. Catalog HY /US SERIES CAVITY DESCRIPTION FLOW PRESSURE PAGE NO.

Table of Contents. Overview 1. Pump Disassembly 2. Control Disassembly / Reassembly 7. Pump Reassembly 13. Adjustment Procedures DR Control 19

Pipe Cutting and Beveling Clamshells

Flow divider (flow distributor), type TQ

300 SERIES 331, 332, 333, 344, 356 AND 367 MODELS

STEERING SYSTEM - POWER

Energy Recovery Device isave 21-40

Chapter 5: Flow Valves

The conditions below apply to the curves shown on the following pages.

Presented by Rory S. McLaren. SAFE by DESIGN

CENTRIFUGAL PUMP OVERVIEW Presented by Matt Prosoli Of Pumps Plus Inc.

Cooling system components, removing and installing

Quiz On Information Learned From Chapter 1

Transcription:

BQ FIXED DISPLACEMENT HYDRAULIC VANE PUMPS BQ SERIES Versatility, power, compactness and low running costs are the main characteristics of B&C vane pumps. All the components subject to wear are contained in a cartridge unit that can be easily removed for inspection and/or replacement without disconnecting the pump from the circuit, drastically reducing expensive machine down time. The cartridge contains a rotor, vanes and inserts, a cam ring, two flexible plates and two covers. During operation the rotor is driven by a splined shaft coupled to the drive unit. As the rotation speed increases, centrifugal forces, in combination with the pressure generated behind the vanes, push the vanes outwards, where they follow the profile of the cam with a sufficient contact pressure to ensure adequate hydraulic sealing. The two opposed pumping chambers formed by the elliptical profile of the cam cancel out radial loads on the shaft bearings, thereby giving them extremely long lifetimes. The design characteristics of the BQ series pumps make them particularly suited to applications in the mobile field. The special design of the flexible plates enables any thermal expansion in the rotor to be compensated for and to adequately cope with any sudden change in pressure. Furthermore, the counterpressure chambers positioned between the flexible plates and the cartridge covers balance the internal pressure; this ensures that the correct clearance between the rotor and the flexible plates is always maintained so guaranteeing maximum volumetric efficiency (see drawing). Flexible side plates Counter-pressure chambers The BQ series is available in five versions of single pump (from 8 to 23 at 12 rpm) and seven versions of double pump (from 55 to 37 at 12 rpm), with maximum powers of over 3 HP. The BQ series pumps are extremely compact and are supplied with ISO norm mechanical couplings and SAE norm hydraulic fittings. This makes them very easy to install and guarantees their interchangeability with other similar pumps. 1

BQ3 Cartridge Series A3 A3 Model 24 28 24 28 A3243 A3287 A3244 A3288 Screw M829 Torque to 12 Nm (91 lb. in.) Pump rotat. right hand left hand Id. codes of pump components Model 1 11 86 9 Shaft kit M8361 M83611 M83686 M8369 Model 1 11 86 9 Shaft Key K31 K311 K386 K39 M811 - M8286 - Body M831 Bearing M823 M826 M8265 M8261 M8266 Shaft seal Type primary in NBR primary in FPM secondary in NBR secondary in FPM Cover M832 Seeger M825 Seeger M824 M82131 M82132 M82133 M82134 Pump seal kit Parts seals + 1 shaft seal seals + 2 shaft seals seals + 1 shaft seal seals + 2 shaft seals Type NBR NBR FPM (Viton ) FPM (Viton ) 22

BQ4 General description Fixed displacement vane pump, hydraulically balanced, with capacity determined by the type of cartridge used and the speed of rotation. The pump is available in five versions with capacities from 8 to 14 (from 21 to 38 gpm) at 12 rpm and 7 bar. Technical characteristics Cartridge model Geometric displacement Rated Rated Maximum capacity capacity pressure at 12 rpm 7 bar at 15 rpm 7 bar with mineral oil Speed range rpm cm 3 /g (in 3 /r) (gpm) (gpm) bar (psi) min max A4-21 69, (4.2) 79,5 (21) 11,4 (26.8) 21 (35) 6 25 A4-25 81,6 (5) 94, (25) 12,1 (31.7) 21 (35) 6 25 A4-3 97,7 (6) 113,8 (3) 141,2 (37.3) 21 (35) 6 25 A4-35 112,7 (6.9) 131,6 (35) 167,2 (44.1) 21 (35) 6 24 A4-38 121,6 (7.4) 139,9 (38) 177,3 (46.8) 21 (35) 6 24 Hydraulic fluids: mineral oils, phosphate ester based fluids. Viscosity range (with mineral oil): from 13 to 86 cst. (13 to 54 cst. recommended). Filtration: for the inlet - 149 micron abs., for the return line - 25 micron abs. or better (with synthetic fluids: for the return line - 1 micron abs. or better). Inlet pressure: (with mineral oil): from -,17 to +1,4 bar (-2.5 to + 2 psi) Operating temperature: with mineral oil -1 C +7 C (+3 C to +6 C recommended). Drive: direct and coaxial by means of a flexible coupling. 23

% correction factor for the max speed RPM single pump BQ4 Main operating data max pressure / hydraulic fluid 25 3625 2 29 15 1 2175 145 5 725 Antiwear industrial hydraulic oil Syntetic fire resistant fluid max pres. peack pres. (,5 sec.max) 25 max speed / hydraulic fluid (with bar in the intake pipe) 2 15 1 5 Antiwear industrial hydraulic oil Syntetic fire resistant fluid cart. 21, 25, 3 cart. 35,38 If the intake pressure is not zero bar, use the graph below to find the percentage correction factor to apply to the maximum speed -2,9-1,45 11% 18% 16% 14% 12% 1% 98% 96% 94% 92% max speed / intake pipe pressure 1,45 2,9 4,35 -,2 -,1,1,2,3,4 intake pipe pressure () 5,8 24

BQ4 18 16 14 12 1 8 6 4 2 flow / pressure 725 145 2175 29 3625 25 rpm 18 rpm 15 rpm 12 rpm 1 rpm 6 rpm 42 31,5 21 1,5 GPM KW Cartridge A4-21 power / pressure 725 145 2175 29 3625 8 18,8 7 25 rpm 6 81,6 5 18 rpm 4 15 rpm 54,4 12 rpm 3 1 rpm 2 27,2 6 rpm 1 HP 5 1 15 2 25 Oil viscosity: 25 c.st.(1w) Temperature: 45 C Inlet pressure: NM input torque / pressure 5 1 15 2 25 725 145 2175 29 3625 3 2 1 5 1 15 2 25 flow / pressure 725 145 2175 29 3625 25 66 9 Cartridge A4-25 power / pressure 725 145 2175 29 3625 2 25 rpm 52,8 8 7 25 rpm 18,8 15 1 18 rpm 15 rpm 12 rpm 1 rpm 5 13,2 6 rpm 5 1 15 2 25 Oil viscosity: 25 c.st.(1w) Temperature: 45 C Inlet pressure: NM 4 3 2 1 39,6 26,4 GPM KW 4 1 input torque / pressure 18 rpm 15 rpm 12 rpm 1 rpm 6 rpm 5 1 15 2 25 725 145 2175 29 3625 5 1 15 2 25 6 5 3 2 81,6 54,4 27,2 HP 25

BQ4 flow / pressure 725 145 2175 29 3625 25 66 2 25 rpm 52,8 15 18 rpm 39,6 15 rpm 1 26,4 12 rpm 1 rpm 5 13,2 6 rpm GPM KW 4 2 Cartridge A4-3 power / pressure 725 145 2175 29 3625 12 1 8 6 25 rpm 18 rpm 15 rpm 12 rpm 1 rpm 6 rpm 136 18,8 81,6 54,4 27,2 HP 5 1 15 2 25 Oil viscosity: 25 c.st.(1w) Temperature: 45 C Inlet pressure: 1 NM input torque / pressure 725 145 2175 29 3625 6 4 2 5 1 15 2 25 flow / pressure 725 145 2175 29 3625 3 79,2 25 66 2 15 5 24 rpm 18 rpm 15 rpm 12 rpm 1 rpm 6 rpm 5 1 15 2 25 Oil viscosity: 25 c.st.(1w) Temperature: 45 C Inlet pressure: NM 52,8 39,6 26,4 13,2 GPM KW 12 5 1 15 2 25 Cartridge A4-35 power / pressure 725 145 2175 29 3625 24 rpm 8 18,8 18 rpm 4 input torque / pressure 5 1 15 2 25 725 145 2175 29 3625 6 4 2 5 1 15 2 25 1 6 2 15 rpm 12 rpm 1 rpm 6 rpm 136 81,6 54,4 27,2 HP 26

BQ4 flow / pressure NM 4 725 145 2175 29 3625 3 79,2 2 5 24 rpm 25 66 15 rpm 15 39,6 8 1 1 rpm 6 rpm 5 1 15 2 25 6 2 18 rpm 12 rpm input torque / pressure 725 145 2175 29 3625 Oil viscosity: 25 c.st.(1w) Temperature: 45 C Inlet pressure: 5 1 15 2 25 52,8 26,4 13,2 GPM KW 4 2 Cartridge A4-38 power / pressure 725 145 2175 29 3625 14 19,4 12 163,2 1 6 24 rpm 18 rpm 18,8 15 rpm 81,6 12 rpm 1 rpm 54,4 6 rpm 5 1 15 2 25 136 27,2 HP Installation dimensions mm (inches) Approx. weight: 23 Kg. (5 lbs.) 27

BQ4 Pump type Cartridge type 21 25 3 35 38 Model code breakdown BQ 4 G * * * * * (L) * (A) Outlet port positions (outlet viewed from cover end) A = Outlet opposite end B = Outlet 9 CCW from inlet C = Outlet in line with inlet D = Outlet 9 CW from inlet Shaft options mm (inches) Mounting (omit if not required) Pump series Design Seals (omit with standard seals and one shaft-seal in NBR) V = seals and shaft-seal in FPM (Viton ) D = standard seals and double shaft-seals in NBR F = seals and double shaft-seals in FPM (Viton ) Rotation (viewed from shaft end) L = left hand rotation CCW (omit if CW) Shaft end options 1 = Straight with key (standard), 11 = Splined 86 = Heavy duty straight keyed, 9 = Splined SAE C Shaft 1 Shaft 11 Shaft 86 PORT ORIENTATIONS Spline data (Shaft 11 and shaft 9) Spline Involute side fit (ASA B5.15) Pressure angle 3 No. of teeth 14 Pitch 12/24 Major dia. 31.6-31.5 (1.244-1.24) Pitch dia. 29.634 (1.1667) Minor dia. 26.99-26.66 (1.627-1.5) Wildhaber 15.68-15.73 (.617 -.619) Shaft 9 28

BQ4 Cartridge Series A4 A4 Model 21 25 3 35 38 21 25 3 35 38 A4213 A4257 A4311 A43515 A43819 A4214 A4258 A4312 A43516 A4382 Screw M842 Torque to 225 Nm (21 lb. in.) Id. codes of pump components Shaft kit Shaft Key Body Pump rotat. right hand Model 1 11 86 9 M8461 M84611 M84686 M8469 Model 1 11 86 9 K41 K411 K486 K49 M841 - M8486 - M8414 left hand Bearing M8416 M8419 M84195 M84191 M84196 Shaft seal Type primary in NBR primary in FPM secondary in NBR secondary in FPM Cover M8415 Seeger M8418 Seeger M8417 M84241 M84242 M84243 M84244 Pump seal kit Parts seals + 1 shaft seal seals + 2 shaft seals seals + 1 shaft seal seals + 2 shaft seals Type NBR NBR FPM (Viton ) FPM (Viton ) 29

BQ 11 1 2 3 4 1 5 6 Id. codes of cartridge kit components 8 4 1 5 9 7 1 13

BQ 1 2 3 4 5 6 7 8 9 1 11 Cartridge Screw Series Model Pin Inlet support plate Seal pack (4+4 pcs) Flex. plate (2 pcs) Rotor Vane and insert kit (1+1 pcs) 2 L7292 L7293 L7293 L7292 Ring Outlet support plate Seal kit (12 pcs) Bushing ( * ) 5 L7292 L7293 L7291 L7295 8 L7292 L7293 L7291 L7298 9 L7292 L7293 L7291 L7299 A1 11 L729 L728 L722 L7213 L72715 L723 L7212 L72111 L721 L7211 L726 12 3,6 Nm L722 L723 L7212 L72112 L7221 (FPM) 14 (32 lb. in.) L722 L723 L7212 L72114 12 L725112 14 L725114 A2 17 L7259 L7258 L7252 L72513 L725715 L7253 L72512 L725117 L7251 L72511 L7256 19 5,5 Nm L725119 L72521 (FPM) 21 (49 lb. in.) L725121 A3 24 L739 L7258 L7252 L72513 L725715 L733 L7312 L73124 L7251 L72511 L7256 28 5,5 Nm L73128 L72521 (FPM) 21 L735121 25 L735125 A4 3 L7359 L7358 L7352 L73513 L735715 L7353 L73512 L73513 L7351 L73511 L7356 35 12,6 Nm L735135 L73521 (FPM) 38 (112 lb.in) L735138 42 L745142 47 L745147 A5 5 L7459 L7458 L7452 L74513 L745715 L7453 L74512 L74515 L7451 L74511 L7456 57 12,6 Nm L745157 L74521 (FPM) 6 (112 lb.in) L74516 ( * ) Note: the cover end cartridge of the double pump is without bushing 14

BQ Operating instructions Maximum speed: the maximum speeds given in this catalogue are valid for an atmospheric pressure of 1 bar (14.7 psi) and with ambient temperature in the range of +3 C to +5 C. Higher speeds than those given cause a reduction in the volumetric efficiency, due to cavitation phenomena in the inlet area inside the pump. Sustained excess speed causes a rapid deterioration of the internal components reducing the lifetime of the cartridge. Minimum speed: In general, the min. speed for all pumps is 6 rpm. However, it is possible to operate at lower speeds with certain pump configurations and with appropriate operating temperatures. Inlet pressure: the inlet pressure, measured at the inlet port, should remain within the prescribed limits. Note that pressures lower than minimum limit cause cavitation and pressures above the maximum limit cause abnormal loads on the shaft and the bearings. In both cases this causes a significant reduction in the lifetime of the cartridge. Maximum outlet pressure: the maximum outlet pressure is different for each type of fluid used as can be seen from the corresponding diagrams. With optimal temperature and filtration conditions a pressure peak of +1% is permissible for a maximum time of.5 sec. Mounting and drive connections: consider the following indications when preparing the installation drawings for the system: the pump is designed to operate with keyed shaft coupled axially and by means of a flexible coupling to the drive; the clearance between the keyed shaft and the corresponding sleeve coupling has to be between.4 and.3 mm; avoid axial and radial loads on the shaft; the mounting flange has to be perpendicular to the drive shaft, with a maximum error of.18 mm every 1 mm; when mounting onto a gearbox, or other component without a flexible coupling, it is advisable to order pumps with splined shaft. In this case the clearance between splines has to be between.13 and.51 mm on the pitch diameter. Hydraulic circuit: always install a pressure relief valve on the supply line to prevent the pressure from exceeding the allowed maximum. Normally, it is set in accordance with the weakest component in the system. (In the case where it is the pump, set the valve to a pressure 15% higher than the maximum pressure rating of the pump.) Inlet line tubing should have a section equal to or greater than that of the inlet port of the pump. It is advisable to keep the tube connecting the pump to the reservoir as short possible. Particular care has to be taken with the inlet line which has to be hermetically sealed to avoid entraining air into the circuit; this varies the characteristics of the hydraulic fluid causing the operating parts to become damaged. Filtration: the inlet line filter must have a flow rate capacity that is higher than that of the pump at its maximum operating speed. The filtration requirements for individual models are given in this catalogue. The use of a filter by-pass is recommended for cold starts and should the filter become clogged. Proper maintenance of the filter element is essential for the correct operation of the entire system. In normal conditions replace the filter element after the first 5 hours of operation. Subsequently, replace it at least every 5 hours. Regarding the filter on the return line, the same general conditions apply as for the inlet line and it should be positioned in an accessible location for ease of maintenance. Tank: if possible, the reservoir should be positioned above the pump. Otherwise, ensure that the minimum level of the fluid contained in it is higher than the pump inlet line opening. It is important to avoid draining the inlet line with the pump at standstill. The opening of the return line into the reservoir must remain below the minimum level of the fluid in the reservoir. It must not be positioned too close to the opening of the inlet line to avoid the possibility of any air bubbles passing into the inlet line. Baffles inside the reservoir may be useful in avoiding the problem. Rapid temperature changes can cause condensation on the underside of the lid of the reservoir with the formation of droplets of water that can fall into the oil. To avoid this problem it is recommended that the lid should have small vents so that the air space in the reservoir is ventilated. The vents have to be screened, though, to prevent the entry of dust or the sudden expulsion of fluid. Start-up: use the following procedure when the pump is started-up for the first time: completely fill the pump and the inlet line with fluid; start the engine for approximately one second a number of times at regular intervals of approximately 2 or 3 seconds until the noise level reduces, thereby confirming that it has been primed; with a manometer check to ensure that the outlet pressure increases slightly; once the pump has been primed, maintain low pressure levels activating all parts of the circuit a number of times until air bubbles disappear completely from the return line to the reservoir. This procedure should be carefully as any residual air inside the pump can quickly cause the rotor to seize. Cold starting: when starting the pump, especially with low ambient temperatures, operate with moderate speed and pressure until the average temperature in the entire circuit is within the given limits. The information provided in this catalogue is subject to change without notice 28 B&C 15