ON TRACK Reprocessing Inservice / Competency for GI Endoscopes (EVIS, EXERA, EXERA II)

Similar documents
Standard Operating Procedure

Christina Bradley Hospital Infection Research Laboratory Queen Elizabeth Hospital Birmingham, UK

National Endoscopy Programme. Decontamination Standards for Flexible Endoscopes

Administration of Meropenem For Child

Reprocessing. Critical & Semi-Critical Equipment

University of Kentucky / UK HealthCare Policy and Procedure. Policy # A03-030

For safety information, see the ABI PRISM 310 Genetic Analyzer User s Manual (PN or ).

Reprocessing Flexible Endoscopes Avoiding Reprocessing Errors Critical for Infection Prevention and Control

URGENT FIELD CORRECTION. REVISED ED 530XT OPERATION MANUALS: Cleaning, Disinfection and Storage, CODE 202B D Operation

Cleaning and High Level Disinfection of Semi-Critical Medical Devices

Standards of Infection Control in Reprocessing of Flexible Gastrointestinal Endoscopes

Standards of Infection Control in Reprocessing of Flexible Gastrointestinal Endoscopes

MANY OF TODAY S SURGERIES USE MINIMALLY INVASIVE

Operation Manual FOR & 14030

PATIENT GUIDE. Care and Maintenance Drainage Frequency: Max. Drainage Volume: Dressing Option: Clinician s Signature: Every drainage Weekly

Policy and Procedure Flushing and / or Blood withdrawal Aspiration Procedure For PICC Line and Midline Catheters

SCION tc DASH APPLIQUE Preparation

Artisan Thermostatic basin mixer. Fitting Instructions & Contents List

CARING FOR YOUR WATER HEATER

San josé OWNER S MANUAL

Electric Kettle. Model: SK-1717 INSTRUCTIONS MANUAL

Back to Basics: Flexible Endoscope Processing LISA SPRUCE, DNP, RN, CNS-CP, CNOR, ACNS, ACNP, FAAN

ENGINE FUEL FUEL FILTER... FUEL HEATER... INJECTOR... SUPPLY PUMP... COMMON RAIL... FUEL PRESSURE LIMITTER...

Outlines: Original Artwork: LeMaitre. Light Post Adapter. Light Post Adapter. Fits Olympus, Storz, and Stryker Equipment* English Instructions for Use

Instruction Manual. Image of SP-3015 & SP Important Safeguards. Automatic Dispensing Hot Water Pot with Reboil Function

100 Series Maxi Internal Filters. Instruction Manual

Standards of Infection Prevention in Reprocessing Flexible Gastrointestinal Endoscopes

REPROCESSING OF FLEXIBLE CYSTOSCOPES

B150 Series Commercial Brewer. Direct Plumb Kit

Your Guide to Peritoneal Dialysis Module 3: Doing Peritoneal Dialysis at Home

PICCs and Midline Catheters

Installation and Operating Instructions Installation Instructions for SS EPE-316L Series

AU680 Every Other Week or Every 3,000 Samples (ISE) Maintenance. AU680 Weekly (Analyzer and ISE) Maintenance

FLUSHOMETER - TANK SYSTEM

ClikSTAR - Important facts about your new insulin delivery device.

Instructions for Use. Components of the GENOTROPIN PEN 12

Ward 29 guide to the safe preparation and administration of intravenous (IV) antibiotics at home

- Do not immerse cords, pump or any electrical wire or device in water or other liquid.

orlando OWNER S MANUAL

CADD-legacy PCA pump Model ml Cassette

Patient Information Guide Morpheus CT Peripherally Inserted Central Catheter

Anti-decubitus Mattress 418E 516E - 820Z User's manual

MAP COFFEE MIA CAPSULE COFFEE MACHINE INSTRUCTION MANUAL MODEL: CM4725. Read this manual thoroughly before using and save it for future reference

Aseptic Technique. A GMP/GTP Training Module

July 24, Dear Health Care Professional:

ClearView 100. Instruction Manual

DASH KIT INSTALLATION

Line to Refrigerator Ice/Water Dispenser

Instructions and User Guide. Select Series: Vascular Access Ultrasound Training Models BPO100, BPBV110, BPP120, BPNB150. June 8, 2011 Rev 2.

Appendix J IBC Biohazard Spill Management Plan

LifeASSURE PFS Series Filter Cartridge Integrity Testing

Underwater Housing for Sony RX100 III, RX100 IV

Promoting safer use of injectable medicines

National- Spencer Inc.

PATIENT GUIDE. Care and Maintenance Drainage Frequency: Max. Drainage Volume: Dressing Option: Clinician s Signature: Every drainage Weekly

III-701 Urinary Catheterization/Bladder Irrigation Original Date: 3/1/1977 Last Review Date: 10/28/2004

In use test of a Washer-disinfector reprocessing of flexible endoscopes

GenStore Archive Cabinet

Operator Quick Guide EC SENSOR

Make sure oven is OFF. Never remove parts or touch the fan unless the oven is OFF.

CDS TROUBLESHOOTING SECTION I. VACUUM Weak vacuum at wand. Gauge reads normal (10hg to 14hg)

EVANS ELECTRONIC TEMPERATURE CONTROL TROUBLESHOOTING GUIDE for systems equipped with electric coolant valve and external PC board.

Med-Aire 8 Alternating Pressure Mattress Replacement System With Low Air Loss

Installation Instructions S

ETD3 the new standard in endoscope reprocessing.

Cidex OPA Solution Training Checklist and Competency for Semi-Critical Medical Devices

How to Change a Foley Catheter Step-by-step instructions for the caregiver

FASCINATION 700 HVLP TANNING PRO SYSTEM USER MANUAL

CHROME FRONT BRAKE MASTER CYLINDER KIT

rainbowsystem.com Rexair LLC Troy, Michigan 2011 Rexair LLC R14388A-0 Printed in U.S.A.

Super Cascade Filtration Systems (CE)

Archived. Gloves should be changed frequently during the analysis.

Caring for a Tenckhoff Catheter

Approval of this procedure is provided by signatory indicated in the approval block at the footer of Page #1, for and on behalf of Jabiru Pty. Ltd.

Quick Start Guide See Inside for Use and Safety Information

TROUBLESHOOTING FLOW CHART

Located On IV Pole Front of cart- Arrest Board

Cleaning Instructions, Pilot Replacement and Valve Change. Model No.: Natural Gas

I-140 Venipuncture for Blood Specimen Collection

Standard laryngoscope blade assemblies Directions for use

20 GALLON WET DRY VACUUM

Artisan Thermostatic bath shower mixer. Fitting Instructions & Contents List

Section 6: Your Hemodialysis Catheter

PUMP MAINTENANCE SCHEDULE AND CHECKLISTS

Changing Your Central Line Catheter Cap

Assembly and Installation Procedures

Pediatric Multi-Venous IV Arm Kit. Directions for Use

PERIPHERALLY INSERTED CENTRAL CATHETERS (PICC) Fong So Kwan APN, Haematology unit Medical Department, QMH

Operating Instructions & Maintenance Guidelines for Precision Vaporizers

Use and Disposal of Sharps

Dentalaire Owner s Manual for all Dental Stations

CATHETERISATION. East Lancashire Hospitals NHS Trust Eileen Whitehead 2010

Procenter Delivery System* Troubleshooting Charts

InfectIon PreventIon checklist for outpatient settings:

Expert Opinion. on the efficacy of. EndoDet and EndoDis + EndoAct. for cleaning and disinfection of. Olympus Gastroscope Type GIF-2T200.

Installation Operation Maintenance Troubleshooting

Chill 4 Hole Bath Shower Mixer

Private Water Supplies Sampling Manual. A Field Guide

Transcription:

THIS CHECKLIST IS DESIGNED FOR USE SOLELY AS A CUSTOMER EDUCATIONAL TOOL, AND IS NOT INTENDED TO REPLACE OR ANY WAY MODIFY THE OLYMPUS INSTRUCTION MANUAL/REPROCESSING MANUAL. BE SURE TO FOLLOW THE DETAILED STEPS OUTLINED IN THE REPROCESSING MANUAL THAT WAS INCLUDED WITH YOUR OLYMPUS EQUIPMENT WHEN PURCHASED. WHILE OLYMPUS TRAINING MAY BE USED IN SUPPORT OF A FACILITY S OVERALL COMPETENCY PROGRAM, IT SHALL NOT CONSTITUTE CERTIFICATION OF THE FACILITY S CDS PROTOCOL. OLYMPUS SHALL IN NO EVENT BE HELD RESPONSIBLE FOR A FACILITY S PROPER PERFORMANCE OF CDS PROTOCOL NOR STAYING CURRENT WITH ONGOING CDS INSTRUCTIONAL CHANGES AND CORRESPONDING TRAINING UPDATES. FACILITY OWNERS OF OLYMPUS EQUIPMENT ARE FULLY RESPONSIBLE FOR COMPLYING WITH INDUSTRY CDS STANDARDS AND MANUFACTURER S PROPER USE AND CDS INSTRUCTIONS. Attendance Sheet Facility Name: Endoscope Models: (List each model reviewed during this session) Date: Olympus Inservice Training (Olympus Instructor): Print Name Signature Title OR Facility-verified Competency (Authorized Facility Staff Member): Print Name Signature Title Print Name Signature Page 1 of 7

Precleaning Wear appropriate personal protective equipment Wipe down the insertion tube with a detergent soaked lint free cloth Immerse distal tip in detergent and depress suction valve to aspirate detergent for 30 seconds Remove distal tip from detergent solution and depress suction valve to aspirate air for 10 seconds Turn OFF suction pump and light source Attach air/water channel cleaning adapter and set the light source airflow to HIGH Immerse the distal tip in clean water Depress air/water channel cleaning adapter and feed water for 30 seconds Release the air/water channel cleaning adapter for 10 seconds or more to let air through the channel Turn OFF light source o Connect auxiliary water tube (MAJ-855) to auxiliary water inlet o Immerse distal end in a container of clean water o Use a 30 cc syringe to flush detergent solution through auxiliary water tube until no bubbles exit the distal end o Use a 30 cc syringe to flush clean water through auxiliary water channel several times o Use a 30 cc syringe to flush air through auxiliary water channel until steady stream of air bubbles exits distal tip o Attach washing tube (MH-974) to the elevator channel plug o Use 5 cc syringe to flush detergent solution through the elevator wire until no bubbles exit the distal tip o Use 5 cc syringe to flush water through elevator wire channel several times o Use 5 cc syringe to flush air through elevator wire channel until a steady stream of bubbles exits distal tip Disconnect all removable and reusable parts from the endoscope Confirm that water resistant cap is dry and free of debris and attach water resistant cap Transport to reprocessing area in covered container Demonstrated ( ) Comments Leakage Testing Demonstrated Comments Fill a basin with clean water Confirm that there is no water inside the leakage tester s connector cap Connect leakage tester to air source and confirm that air is being emitted Connect leakage tester to the endoscope and confirm bending section inflation Completely immerse the endoscope in water Observe for 30 seconds while angulating the bending section Remove endoscope from the water and turn OFF the air source Disconnect leakage tester from the air source Wait 30 seconds, or until bending section contracts to its pre-expansion size Disconnect leakage tester connector cap from venting connector Page 2 of 7

Manual Cleaning Demonstrated Comments Fill a basin with detergent solution prepared as recommended by the manufacturer Completely immerse the endoscope in detergent solution. Use a brush or lint-free cloth to thoroughly clean all external surface For JF/TJF model duodenoscopes and other endoscope models with elevator wire channel, brush around the forceps elevator Use endoscope model-specific brushes to brush channels/cylinders/ports until no visible debris remains o Brush the suction channel in the insertion tube o Brush the suction channel in the universal cord o Brush the suction cylinder o Brush the instrument channel port Attach the suction cleaning adapter to the instrument channel port Connect the suction tube from the suction pump to the suction connector on the endoscope Immerse the distal end and weighted end of suction cleaning adapter in detergent Ensure distal end of endoscope and distal end of suction cleaning adapter remain in detergent solution Cover the suction cylinder and aspirate detergent solution for approximately 30 seconds Turn OFF the suction source and disconnect the suction tube Disconnect suction tube and the suction cleaning adapter. Reprocess them as described in Olympus instructions, Cleaning, Disinfection and Sterilization Procedures for Removable Parts and Cleaning/Reprocessing Equipment o Immerse the distal tip in detergent solution and raise and lower forceps elevator 3 times o With forceps elevator raised, use 30 cc syringe to flush interior of forceps elevator with detergent solution Attach the channel plug Facilities Manually Flushing With a Syringe Attach the injection tube Immerse the suction port of the injection tube into detergent solution prepared as recommended by the manufacturer Attach a 30 cc syringe to injection tube. Inject 90 cc detergent solution into the each side of the injection tube o Attach the auxiliary water (MAJ-855) tube to auxiliary water inlet o Use a 30 cc syringe to flush 90 cc of detergent solution into the auxiliary water channel o Disconnect the auxiliary water tube from the endoscope and immerse in detergent solution o Attach the washing (MH-974) tube to elevator channel plug o Use a 5 cc syringe to inject 15 cc of detergent solution into elevator wire channel o Disconnect washing tube from endoscope and immerse in detergent solution Detach cleaning equipment Soak in detergent solution with the endoscope for time and temperature specified by the detergent manufacturer Wipe down the endoscope with a lint-free cloth while the endoscope is immersed in detergent solution Page 3 of 7

Manual Cleaning (cont.) Demonstrated Comments Remove the endoscope and equipment from the detergent solution Immerse endoscope and equipment in clean water and gently agitate to rinse Reconnect the connector plug and injection tube Use a 30 cc syringe to inject 90 cc of water through each side of the injection tube o Attach a 30 cc syringe to the auxiliary water tube (MAJ-855) and inject 90 cc of clean water : o Attach a 5cc syringe to the washing tube (MH-974) and flush the elevator wire channel with 5cc of clean water o Use a 30cc syringe to inject 90cc of air through the auxiliary water tube : o Use a 5cc syringe to flush 10cc of air through the elevator wire channel Disconnect cleaning equipment. Reprocess as described in Olympus instructions, Cleaning, Disinfection and Sterilization Procedures for Removable Parts and Cleaning/Reprocessing Equipment Use a lint-free cloth to dry all external surfaces, channel plug and injection tube Facilities Using the EFP250 Endoscope Flushing Pump to Replace Manual Flushing Fill two-liter container with detergent solution prepared as recommended by the manufacturer Connect inlet hose to EFP250 Connect main channel assembly (BLUE) to EFP 250 Press the blue START / STOP button For scopes with elevator wire or auxiliary water channel o Connect Special Channel Assembly (PURPLE) o Press the PURPLE START / STOP button Discard used detergent Rinse and fill containers and endoscope basin with clean water Press BLUE and PURPLE (if applicable) START / STOP button(s) Place screened end of inlet hose in empty container Press BLUE and PURPLE (if applicable) START / STOP button(s) Use a clean, lint-free cloth to thoroughly wipe and dry the external surfaces of the endoscope and reprocessing equipment and continue reprocessing Page 4 of 7

Automated Endoscope Reprocessor (AER) High-Level Disinfection* AER type: High-level disinfectant type: Test the potency of the disinfectant solution according to the manufacturer s instructions Inspect the connections according to the AER manufacturer s instructions Verify that the proper connector is being used for the endoscope being reprocessed Attach the endoscope connectors/adapters to the AER and endoscope as per the AER manufacturer s instructions Operate the AER according to the AER manufacturer s instructions Ensure the endoscope is soaked in disinfectant solution according to the liquid chemical germicide manufacturer s recommendations for time and temperature Remove the endoscope promptly after the AER cycle is completed Perform the terminal steps that the AER does not perform (for ex: alcohol and air purge) *FOR FACILITY INTERNAL USE ONLY! Olympus personnel are unable to demonstrate use of individual manufacturer s AER Page 5 of 7 Comments Manual High-Level Disinfection Demonstrated Comments Fill a basin with disinfectant solution Test the potency of the disinfectant solution according to the manufacturer s instructions Attach the channel plug and injection tube to the endoscope Completely immerse the endoscope and equipment in disinfectant solution Use a 30cc syringe to inject 90cc of disinfectant into each side of the injection tube. Confirm that no bubbles exit the distal tip o Attach the auxiliary water tube (MAJ-855) o Use a 30cc syringe to inject 90cc of disinfectant through the auxiliary water tube For JF model duodenoscopes and other model endoscopes with elevator wire o Attach the washing tube (MH-974) o Use a 5 cc syringe to flush 10cc of disinfectant solution through the elevator wire channel via the washing tube. Confirm that no bubble exit the distal tip o While immersed in disinfectant solution, raise the forceps elevator and flush with disinfectant using a 5 cc syringe Disconnect all equipment from the endoscope Remove any bubbles that adhere to the surfaces with a clean lint-free cloth Soak endoscope and equipment for the time and at the temperature recommended by the disinfectant manufacturer Reconnect the channel plug and injection tube to the endoscope Attach 30cc syringe to each port on the injection tube and inject 90cc of air o Reattach the auxiliary water tube (MAJ-855) o Use 30cc syringe to inject 90cc of air through the auxiliary water tube For JF/TJF model duodenoscopes and other model endoscopes with elevator wire: o Reattach the washing tube (MH-974) o Use 5cc syringe to flush 10cc of air through the elevator wire channel Remove the endoscope and equipment from disinfectant Disconnect equipment from endoscope

Rinsing Demonstrated Comments Fill a basin with sterile water, filtered water, or tap water Completely immerse the endoscope and equipment in the water Wipe all external surfaces with a lint-free cloth Attach the channel plug and injection tube to the endoscope Use a 30cc syringe to inject 90cc of water through each side of the injection tube o Attach the auxiliary water tube (MAJ-855) o Use 30cc syringe to inject 90cc of water o Attach the washing tube (MH-974) o Use 5cc syringe to flush 15cc of water through the elevator wire channel Remove the endoscope and equipment from the water Cover the distal tip with a lint-free cloth Use a 30cc syringe to inject 90cc of air through each side of the injection tube o Attach the auxiliary water tube (MAJ-855) o Use 30cc syringe to inject 90cc of air o Attach the washing tube (MH-974) o Use 5cc syringe to flush 15cc of air through the elevator wire channel Disconnect all equipment from endoscope Wipe all external surfaces with a lint-free cloth Alcohol Flush Demonstrated Comments Attach a reprocessed channel plug and injection tube to the endoscope Immerse suction port of injection tube in 70% isopropyl or ethyl alcohol Attach a 30cc syringe to each port of the injection tube and inject 90cc of alcohol Remove the suction port from the alcohol o Attach a reprocessed auxiliary water tube (MAJ-855) o Use a 30cc syringe to inject 90cc of alcohol For JF model duodenoscopes and other model endoscopes with elevator wire o Attach a reprocessed washing tube (MH-974) o Use 5cc syringe to flush 10cc of alcohol through the elevator wire channel Use a 30cc syringe to inject 90cc of air through each side of the injection tube o Attach a reprocessed auxiliary water tube (MAJ-855) o Use a 30cc syringe to inject 90cc of air For JF model duodenoscopes and other model endoscopes with elevator wire channel o Attach a reprocessed washing tube (MH-974) o Use 5cc syringe to flush 15 cc of air through the elevator wire channel Disconnect all equipment from the endoscope Use sterile cotton swabs to dry the inside of the air/water and suction cylinders and instrument channel port Page 6 of 7

Endoscope Storage Demonstrated Comments Remove all valves and removable parts from endoscope Ensure that angulation locks are in the free position For endoscopes with flexible adjustment mechanism, set the insertion tube to maximum flexibility Store endoscope in a well-ventilated cabinet Hang the endoscope so that the universal cord and insertion tube are hanging vertically and the distal tip of insertion tube is hanging freely Page 7 of 7