Important Things to Know



Similar documents
EXERGEN. English. TemporalScanner TM. Accurate Temperature with a Gentle Forehead Scan. Operators Manual for TAT-5000

EXERGEN. TemporalScanner TM 2000 Series. A kinder, gentler way to take temperature. More accurate than ear thermometry 1

Reference Manual EXERGEN. A kinder, gentler way to take temperature. TemporalScanner TM. Model TAT *Compared to cold-tip thermometers

How To Use A Thermometer

RT-1261A Ear and Forehead Thermometer Owner s Manual

Owner s Manual

Dr.Karima Elshamy Faculty of Nursing Mansoura University Egypt

ThermoScan Instant Thermometer IRT 1020 Type 6005 Home Model

Thermal protection in neonates

THERAPEUTIC USE OF HEAT AND COLD

Brief Caregiver Testing Protocol and Data Collection Procedure

Arterial Thermometry Via Heat Balance at the Ear

Instant Ear Thermometer

CPR/AED for Professional Rescuers and Health Care Providers HANDBOOK

digital fever alert ear thermometer suitable from birth instruction manual

Forehead. Use and Care Manual. Thermometer IMPORTANT! READ AND SAVE THESE INSTRUCTIONS. Model V977

INSTRUCTIONS FOR USE HUMIRA 40 MG/0.8 ML SINGLE-USE PEN

INSTRUCTIONS FOR USE HUMIRA 40 MG/0.8 ML, 20 MG/0.4 ML AND 10 MG/0.2 ML SINGLE-USE PREFILLED SYRINGE

Forehead Thermometer INSTRUCTION MANUAL. Model MC-720

Touchless Forehead Thermometer

Tympanic Thermometer

Year 10 Investigation. What Makes Ice Melt Fastest? By Rebecca Hogan

Name of Child: Date: Fever

Feed a Fever..., or How long should I leave a thermometer in my mouth to take my body temperature accurately?

Heat Production and Loss. Environmental Emergencies. Heat Regulation. Body Temperature Ranges. Focused Assessment: Your Patient: Heat Production

PICCs and Midline Catheters

Caring for Your PleurX Pleural Catheter

MINI - COURSE On TEMPERATURE CONTROL IN THE NEWBORN

SCRIPT NUMBER 123 HEATSTROKE - 2 (ONE SPEAKER)

Temperature Assessment via the Temporal Artery: Validation of a New Method

MEASURING VITAL SIGNS TRAINING CHECKLIST

Single Lens Reflex (SLR) Camera

HEAT-RELATED ILLNESS AND STUDENT ATHLETES. Diana L. Malone, Ph.D. Training & Consultation Coordinator

Health Technician skills checklist Health Services Department Lincoln Public Schools TEMPERATURE

Body Temperature Regulation

Project 4.2.1: Heart Rate

HEAT ILLNESS PREVENTION PLAN FOR SUTTER COUNTY SUPERINTENDENT OF SCHOOLS

INSTRUCTION MANUAL Contactless Clinical Infrared Thermometer GT-101

Managing Heat Stress in Poultry

Symptoms of Hodgkin lymphoma

PR 50 Frymaster Universal Holding Cabinet (UHC)

Instant Ear Thermometer

Success Manual and Cheat Sheet Notes to Pass Your Basic Life Support (BLS) Course

Frequently Asked Questions: REDEFINE ACUTE CARE Skincare for Expression Lines

Safety FIRST: Infection Prevention Tips

Safety Point: Preparing Your First Aid Kit

Futuristic Beauty. Buyers Guide

All About Your Peripherally Inserted Central Catheter (PICC)

Individualized Care Plans Fully Developed

Fact Sheet: Working in hot temperatures

MRC Medical Jeopardy Feud List of Treatments for Possible Injuries/Conditions

Body Temperature Regulation. Amelyn R. Rafael, MD

Chapter 26. Metabolic Rate, Body Heat, and Thermoregulation

Convection, Conduction & Radiation

Heat and Temperature: Front End Evaluation Report. Joshua Gutwill. October 1999

STANDARD OPERATING PROCEDURE #201 RODENT SURGERY

Sanitary Food Preparation & Safe Food Handling

Tell your doctor about all the medicines you take, including prescription and nonprescription medicines, vitamins, and herbal supplements.

Biliary Drain. What is a biliary drain?

Your Recovery After a Cesarean Delivery

FOLFOX Chemotherapy. This handout provides information about FOLFOX chemotherapy. It is sometimes called as FLOX chemotherapy.

PATIENT GUIDE. Care and Maintenance Drainage Frequency: Max. Drainage Volume: Dressing Option: Clinician s Signature: Every drainage Weekly

TEMPERATURE SENSORS AND PROBES FOR BIO-MEDICAL APPLICATIONS

CYGNAL Application Note

Administration of Meropenem For Child

Contents. Introduction... A Note About Heatsinks... Precautions...

Instructions for Wearing your Scoliosis Brace

Femoral artery bypass graft (Including femoral crossover graft)

Peripherally Inserted Central Catheter (PICC) Patient Instructions

Adult First Aid/CPR/AEd. Ready Reference

call 811 to get advice from a nurse, or have someone drive the patient to a hospital Emergency Department. Patients should NOT drive themselves.

EEG Cap Instructions

American Red Cross First Aid EXAMPLE ANSWER SHEET

Peripheral Vascular Bypass Surgery

Heated throw User manual

The human body core temperature is constant around 37.1±1.0 o C ( degree Fahrenheit = degree Celsius )

Ear Infections Fever fever

Electronics and Soldering Notes

RELEVANT HACCP CHARTS: Preparation, Service

SOUTHERN HEALTH & SOCIAL CARE TRUST. Children & Young People s Directorate Procedure/Guidelines/Protocol Checklist & Version Control Sheet

Be Safe! Manage Heat Stress. Be Safe! Manage Heat Stress.

Off to the best start. Important information about feeding your baby

Ancillary Staff Training

Humidity the story for teachers

Section 4: Your Vascular Access. What is vascular access?

Endovascular Abdominal Aortic Aneurysm Repair Surgery

How to Do Self Lymphatic Massage on your Upper Body

Department of Nursing Policy and Procedures Regarding Temporal Artery Thermometry

How to Prepare Formula for Bottle-Feeding at Home

Bydureon 2 mg powder and solvent for prolonged-release suspension for injection in pre-filled pen How to use Bydureon pre-filled pen

LESSON OVERVIEW. Objectives: By the end of the lesson, the Lay Health Worker will be able to:

Your Hearing Aids A guide for helping children and their families understand and take care of their hearing aids

Order of the Weather Experiments

Purpose: To determine the dew and point and relative humidity in the classroom, and find the current relative humidity outside.

Automatic Wrist Blood Pressure Monitor with

Body Heat and Temperature Regulation

CARESCAPE VC150 Vital Signs Monitor. Connecting intelligence and care.

Gallbladder Surgery with an Incision (Cholecystectomy)

SCRIPT NUMBER 123 HEATSTROKE - 2 (TWO SPEAKERS)

GoFit Platinum Power Vibe

Transcription:

EXERGEN TemporalScanner Important Things to Know TA temperature is real time temperature Just like pulmonary artery temperature, TA temperature identifies changes in your patient s temperature sooner than axillary, oral, or rectal temperature. Measure only exposed area Measure only the up-side Anything covering the area to be measured would insulate and prevent the heat from dissipating, resulting in falsely high readings. Brush the hair aside if covering the TA, or the area behind the ear. Measure only the up-side on a patient in a lateral position. The down-side will be insulated preventing the heat from dissipating, resulting in falsely high readings. Measure straight across the forehead, from the center to the hairline (or start at the hairline) ending with a touch on the neck behind the earlobe Slide the thermometer midline straight across the forehead (think of a sweatband), and not down the side of the face. Midline, the temporal artery is about 2mm below the surface, but can go deeply below the surface on the side of the face. Sequential Measurements Result in Variability Sequential measurements cool the tissue, resulting in variable temps. Wait 30 seconds or so for skin to recover, or use the opposite side if exposed. One Measurement TA Temperature on an Infant One measurement, preferably at the temporal artery area, is all that is required on an infant as the perfusion rate is normally strong... If visibly diaphoretic, push aside any clothing or blankets covering the neck area for ~30 seconds or so, and make the measurement on the neck behind the ear. Preferred site is the temporal artery area. Here, behind the ear could be alternate site, as both are exposed. Temporal artery area is the only option here, as the neck area is not exposed. Low Readings Can be Caused by a Dirty Lens Biweekly cleaning of the lens is a good procedure. To clean, simply twirl a cotton tipped swab (Q-Tip) dampened in alcohol on the lens, deep in the center of the probe. Questions? 617-923-9900 x6202

Exergen Temporal Artery Thermometry FAQ s What should I do if I get an abnormally high reading? Repeat the reading with the same thermometer; a correct reading will be reproducible Repeat the reading with another Exergen TA Thermometer; 2 thermometers with the same reading will confirm the reading What should I do if I get an abnormally low reading? Causes of a low or abnormally low reading are: Debris on the lens will cause a low reading. To resolve, dampen a Q-Tip with an alcohol prep pad. Gently twirl on lens, use another Q-Tip to dry. This should be done routinely on a biweekly basis. Premature release of the button. Measuring when an ice pack or wet compress is on the forehead Measuring a completely diaphoretic patient but in this case, the temp is rapidly dropping and fever is not a concern. Wait until the patient is dry and repeat the measurement. Scanning down the side of the face where temporal artery could be embedded under fat or cartilage. Scan straight across forehead. The temporal artery is closest to skin in that area. If you had to remove your patient s glasses, you incorrectly went down the side of the face. If none of the above applies, proceed as with high readings above to confirm the reading. The green area is cool, as the temporal artery can go deep at that point. What are alternative sites because I cannot access the forehead? Femoral Artery Area Scan across the femoral artery in the crease of the groin, keeping button depressed until scan is completed. The femoral artery is a strong artery and has a long history as a temperature measurement site

Lateral Thoracic Artery Area Scan in a zigzag pattern about 4 inches wide from an imaginary line in between the axilla and the nipple, scanning down to the waist and back up to the level of the nipple, keeping the button depressed until scan is completed. Imaginary Line Lateral Thoracic Artery What are alternative sites because of diaphoresis? Area on the Neck behind the Earlobe: Sweat Cools (Green/Blue) If this area is dry, this site can be used alone on a diaphoretic patient or on a patient with head trauma (surgical or accidental), as the neck area is certain to be vasodilated in these two conditions (red area designates heat). We sweat first on the forehead, then the palms of the hands and soles of the feet, then the T-zone on the back, and finally, everything is wet, but the neck area is one of the last places to get wet. If the neck is not accessible, and if dry, the femoral or lateral thoracic artery areas can be used. If all sites are wet, the patient s temperature will be rapidly dropping and fever is not an issue. Return in about 15 minutes when the patient should be dry and take a standard temporal artery temperature. Wiping the sweat will not work as the sweat glands secrete too quickly and the area will still show the effect of evaporative cooling If it is alright to spot check behind one ear, why should I scan the forehead as well? The area behind the ear only works as a sole site if there is 100% vasodilation. In the absence of diaphoresis or head trauma, vasodilation in the neck area is uncertain, making this area too variable to be reliable as a sole site. The woman at the right has normal, constant blood flow in the temporal artery, but she is vasoconstricted in her neck area, which makes it cool (green).

How long should I wait if the scanable area is covered or patient lying on that side. About 30 seconds will be sufficient for the area to equilibrate to the environment How long should I wait between readings? Sequential readings on the same patient in rapid succession will cool the skin, it is best to wait 30 seconds for the skin to recover from the cold probe. How do oral temperatures differ from arterial? Oral temperatures are affected by patient activity such as mouth breathing, coughing, snoring, eating, drinking, etc. Oral temperatures can vary 2-3 degrees depending on the placement of the probe (blue/green = cold, red/yellow = hot). Oral temperatures can seriously mislead the clinician because of the resulting artifactual errors. Temporal artery temperature is not affected by any of these activities. How does this technology work, i.e. how does the device measure heat? The instrument uses an infrared sensor in the center of the probe head to measure the heat naturally emitting from the body The instrument also uses a thermistor (like the electronic thermometers) that is embedded in the back of the probe to automatically measure ambient temperature. This controls for any affect on the skin from ambient temperature. The computer in the instrument then synthesizes the two temperatures to provide a core temperature as accurate as a temperature measured by a pulmonary artery or esophageal catheter. How does this relate to core temperature? Temporal artery temperature, because it has been demonstrated as accurate as the temperature measured by a pulmonary artery and esophageal catheter, and as accurate as a rectal temperature on a stable patient, is considered a core temperature. Rule of thumb: Rectal temperature is about 1 F (0.5 C) higher than an oral temperature and 2 F (1 C) higher than an axillary temperature. It will be easy to remember if you think of core temperature as a rectal temperature, and apply the same protocol you would use for a rectal temperature.

What makes my patient feel hot yet get a normal temperature? Body heat is produced in the deeper core tissues of the body, which is insulated by the subcutaneous tissues and skin to protect against heat loss. Vasoconstriction decreases the transport of core heat to the skin surface, and vasodilation increases transport. During vasodilation, circulating blood transports heat to the skin surface, where it dissipates into the surrounding environment. This is the body s way of maintaining a normal temperature, but the skin can feel warm to the touch, especially if the hand is cool. If no heat is dissipated, body temperature would rise about 1.8 F (1 C) per hour Vasoconstriction does the opposite by decreasing the transport of core heat to the skin surface, keeping it within the deeper core tissues of the body. This allows a fever to increase, but the skin will feel cold to the touch even though the fever is present. Why shouldn t I compare this to an oral with our old devices? The first reason is because your old devices measuring oral temperature are subject to all the patient activities mentioned above. The second reason is because your old thermometers are not measuring an actual temperature but are predicting what the temperature should be if the probe remained in position several minutes. The temporal artery thermometer is measuring an actual temperature. It has been proven in peer-reviewed published studies to be as accurate as temperatures measured by pulmonary artery and esophageal catheters, and as accurate as a rectal temperature on a stable patient. It has also been proven to identify changes in temperature long before rectal temperature, even on infants. Should I use this device with radiant warmers? No, not unless the temporal artery thermometer has been left under the radiant warmer for 30 minutes so it equilibrates to that environment. When equilibrated, the warmer can either be turned off for the short time the temperature is taken, or the temperature can be taken in an area not exposed to the radiant warmer. In the Neonatal Intensive Care Unit, because of all the radiant warmers, nursing staff sometimes prefer to use the Exergen instant axillary thermometer. What about use of bair-huggers or other warming devices? How should we take temperatures? As long as the warming devices are not covering the area being measured, they will not interfere with the use of the temporal artery thermometer.

Do I need to take the temperature of an infant at both the temporal artery area and on the neck behind the earlobe? No, one measurement, preferably at the TA, is all that is required Measurement site must be exposed, push hat up if present Do not use if infant is under a radiant warmer* Above, preferred site is the temporal artery area. Behind the ear could be alternate site, as both are exposed. Above, the temporal artery area is the only option, as the neck area is not exposed. *Use Exergen Neonatal Instant Axillary Thermometer (LXN) under the warmer