HVA200 High Voltage Amplifier



Similar documents
DUAL%CHANNEL BROADBAND%LINEAR%AMPLIFIER Model&A800D

64-CHANNEL INTEGRATED AMPLIFIER

INSTRUCTION MANUAL MODEL PCD-88

The table below lists the symbols used on the Clamp and/or in this manual. Important Information. See manual.

User Manual. CFG253 3 MHz Function Generator

±15 V Current-Limited Power Supply

BroadBand PowerShield. User Manual

User's Manual. Research Isometric Transducer 0 to 5 grams and 0 to 50 grams

TWO/FIFTY/TWO STEREO POWER AMPLIFIER

Daker DK 1, 2, 3 kva. Manuel d installation Installation manual. Part. LE05334AC-07/13-01 GF

user guide Meridian 558 Multi Channel Power Amplifier

How To Use A Cdm250 Digital Multimeter

12-Volt 10-Amp Regulated Power Supply

BXR 300C BXR 300R. Owner, s Manual P/N

EPM3. Phase Sequence and Motor Rotation Tester. Users Manual

USER MANUAL Stand Alone Power Supply PSQ 2909 / PSQ 3909 / PSQ 4909 PSQ 2920 / PSQ 3920 / PSQ 4920

Infrarot-Bewegungsmelder IP44

Contents. Safety Warnings... 1

CX Zoner Installation & User Guide

Congratulations! Thank you!

Operating Manual UWAPS-TINY Series

Antenna Splitter ASA 1. Instruction manual

Installation and Operation Manual Back-UPS BX800CI-AS/BX1100CI-AS

Perseus. Owner s Manual. Vacuum Tube Preamplifier. Rogue Audio, Inc. 3 Marian Lane Brodheadsville, PA Issue date: 02/01/06

i410/i1010 AC/DC Current Clamp

DAB+ / FM Tuner Model: TU-201

Voltech DC1000. Precision DC Bias Current Source

Manual Ranging MultiMeter

Agilent 87421A/87422A Power Supply

Amplified High Speed Fiber Photodetectors

Ground Resistance Clamp On Tester

External Hard Drive esata & USB 2.0 Combo. User Guide English

USER S MANUAL. MaxPower UPS. Uninterruptible Power System 28-2MAXPO0018

user s manual Battery Case model #: SPB3200 Battery Case Charger for Samsung Galaxy S 4

AutoRanging Digital MultiMeter

How To Use A Power Supply Unit (Upu)

LOXONE 12 Channel Amplifier

Achat 115MA full-range speaker. user manual

OPERATION MANUAL. VDA-106A Video Distribution Amplifier. 1 st Edition - Rev.1

Owner s Manual channel amplifier

KEYBOARD EXTENDED RANGE. Sixty Owner, s Manual P/N

Current Probes. User Manual

User s Manual Before using the inverter, you need to read and save the safety instructions.

INSTRUCTION MANUAL for UNIBLITZ MODEL DM412 SHUTTER DRIVE MODULE

TIG INVERTER INSTRUCTION MANUAL

PERF10 Rubidium Atomic Clock

FMT600BT Transmitter

User's Guide. True RMS Industrial Multimeter

aseries A13B Mini Bullet Camera User Manual

Model UT33A: OPERATING MANUAL Table of Contents (1)

************* OWNER'S MANUAL BAMF800/2 BAMF1250/2 BAMF1800/2 BAMF2200/2 BAMF2600/2 BAMF1200/4 BAMF1600/4 BAMF2000/1D BAMF4000/1D BAMF5500/1D

Keysight N4877A Clock Data Recovery and Demultiplexer 1:2

AXIS T81B22 DC 30W Midspan

Mini Power Bank and Charger

STEREO PREAMPLIFIER INSTRUCTIONS FOR USE

Mercury Helios 2 ASSEMBLY MANUAL & USER GUIDE

REGULINE 600VA / 1000VA REGULATOR USER MANUAL

Mini-HDMI Series MINIATURE MULTIMODE FIBER OPTIC HDMI TRANSMISSION SYSTEM

MODEL 2202IQ (1991-MSRP $549.00)

HCS-3300/3302/3304 USB Remote Programmable Laboratory Grade Switching Mode Power Supply

User s Manual AURORA 1.2K/2.2K

Nest Learning Thermostat Installation Guide. Installation step-by-step

CMP30. User Manual.

Agilent P940xA/C Solid State PIN Diode Switches

AMU PROFESSIONAL VIDEO AND AUDIO MONITORING UNIT OPERATOR'S HANDBOOK ISSUE A3

1.44 kw Programmable DC Power Supplies XLN Series

Conference Phone UserÕs Manual. Part No R1 Printed in Korea Bogen Communications, Inc.

Features, Benefits, and Operation

EVOLUTION Thermal Imaging Camera Remote Wireless Video Receiver System

BXR. Owner, s Manual. One hundred BASS EXTENDED RANGE P/N

Operation Manual. 150 Watt Halogen Light Source for Endoscopy Model # s ESS-150, ESS-150A ESS-220, ESS-220A

ST122VGAU. Instruction Manual. VGA Video Switch. 2-Port Automatic VGA Video Switch

INSTALLATION GUIDE. AXIS T8133 Midspan 30W

Berkeley Audio Design Alpha USB

Instructions & Safety Information Models A220-20D and A220-20L Version 2

REB 1 REB 3 REB 5 REB 6 REB 8 REB 10 REB 12 REB 16

Uninterruptible Power Supply

Benchtop Computer Monitor Generator

OWNER'S MANUAL. AtlasSound.com PA601 COMMERCIAL AMPLIFIER. PA601 Commercial Amplifier. Power. Master

Targus Wireless Remote Presenter USER S GUIDE. Making Your Mobile Life Easier. Making Your Mobile Life Easier.

Brio-Rmanual:Cursamanual.qxd 08/04/ :25 Page1

MIC-WKT and MIC-WKT-IR

Ground Resistance Clamp-On Tester

VIEW. SLX300 SpeakerLinX IP Zone. Amplifier Installation and Setup Guide. AVoIP

3000W Power Inverter

DR 70 Portable Digital DAB+ and FM Radio Receiver User Manual English Please read carefully before using this product

FLUORESCENT UV- RING LIGHT OPERATING INSTRUCTION

Instruction Manual. This manual covers models: 8-125E 60-18E 20-50E 80-13E 33-33E 150-7E 40-25E E 50-20E E

Analog Servo Drive 25A8

Tone Hammer 500. Owners Manual. Manual Version 1.0

2-Disk RAID USB and esata External Hard Drive. User Guide English

EVOLUTION Thermal Imaging Camera Remote Wireless Video Receiver System

Model: Manual DC: WIRELESS COLOR FORECAST STATION

User and Installation Guide

Stretch DisplayPort TM

ASP-DTH. DVI & Audio to HDMI Converter. User Manual. Manual Number:

Tina 2A/B Adaptor unit

3 WATT LED SPOTLIGHT Model No. SLM

MCA Series Multi-Channel Amplifiers. Operation Manual

Table Of Contents

Transcription:

HVA200 High Voltage Amplifier Operating Manual

Table of Contents Part 1. Important Safety Notice... 3 Part 2. Product Overview... 4 Part 3. Setup and Operation... 5 3.1. HVA200 Controls and Features... 7 Part 4. HVA200 Specifications... 8 Part 5. Maintenance... 10 5.1. Fuse Replacement... 10 5.2. Ventilation... 10 5.3. Troubleshooting... 10 Part 6. Warranty Information... 11 Part 7. Declaration of Conformity... 12 Part 8. Regulatory... 13 Part 9. Thorlabs Worldwide Contacts... 14 Table of Figures Figure 1: HVA200 Front Panel Features... 7 Figure 2: HVA200 Rear Panel Features... 7 Figure 3: Typical Gain Bandwidth... 9 18014-D02 Rev B, Jan 26, 2009 Page 2 www.thorlabs.com

Part 1. Important Safety Notice Danger High Voltage The HVA200 can produce hazardous voltages and currents which may be harmful or even lethal. Use caution and exercise preventative safety measures to prevent contact between these high voltages and any personnel. Warning! The line switch and fuse must be set to the correct mains voltage. The unit is shipped ready to operate on 115 V. To operate on 230 V, the line switch and fuse must be changed. See Section 5.1: Fuse Replacement. Do Not Open Housing! The HVA200 has no user-serviceable parts. Service should only be performed by trained service personnel. 18014-D02 Rev B, Jan 26, 2009 Page 3 www.thorlabs.com

Part 2. Product Overview The Thorlabs HVA200 High Voltage Amplifier is designed to directly drive the Thorlabs Electro-Optic Modulators. The amplifier features: a large, ±200 V output, a continuous current output of 100 ma, a wide, 1 MHz bandwidth, and low noise. The voltage gain of -20 boosts the input up to the high voltages needed to drive our lithium niobate broadband modulators. An adjustable bias allows for precise DC offset control. The HVA200 uses a high voltage, wideband, high slew rate output amplifier to achieve an output range of ±200 V at a bandwidth up to 1 MHz. The input amplifier includes a summing junction which allows an adjustable DC bias to be added to the input modulation. This composite signal is then boosted by a fixed voltage gain of 20 by the output amplifier. For added safety, a front panel HV Enable button must be pressed to connect the HV output to the output BNC. The output is automatically disabled each time the HVA200 is powered on. The DC Bias control consists of a rotary encoder which allows precise control and repeatability. The bias adjustment is typically used to shift the DC level of the output as needed by the application. A voltage monitor output is provided to allow real-time monitoring of the high voltage output. The monitor has a scaling of 20:1 so that an output of 200 V results in a 10 V monitor voltage. 18014-D02 Rev B, Jan 26, 2009 Page 4 www.thorlabs.com

Part 3. Setup and Operation Warning Before plugging the amplifier into an AC outlet, check that the line switch voltage matches your AC outlet. The amplifier is configured from the factory to operate on 115 V by default. The fuse and line switch will need to be changed for 230V operation. See Section 5.1: Fuse Replacement. To setup the unit, refer to Figures 1 and 2, and the legend table on the preceding page and perform the following steps: 1. See the warning above. Attach the supplied AC power cord to the AC connector on the rear panel and plug into a suitable AC outlet. 2. Connect an EO-modulator to the HV Output connector (6) on the front panel. HV Output Warning The HV output is capable of producing hazardous voltages and currents. The HV output will handle an accidental short circuit without damage, but the output should not be shorted continuously. The current is internally limited to 100 ma. 3. (Optional) Connect the HV monitor (4) to an oscilloscope or volt meter. The input impedance must be at least 50Ω; however, at this value the ratio will be 40:1. The true HV Output to monitor ratio can be calculated with the following equation: V out 20V = monitor ( R + 50Ω) 18014-D02 Rev B, Jan 26, 2009 Page 5 www.thorlabs.com R input input Where: V out is the HV output V monitor is the HV Monitor output R input is the input impedance of the measurement device For impedance values of 50Ω, the equation becomes: Vout = 40V monitor For impedance values of greater than 10 kω, the internal impedance is insignificant and the equation becomes: Vout = 20V monitor

HV Output Monitor Warning The HV Output Monitor requires a minimum load of 50Ω. The port will handle an accidental short circuit without damage, but must not be shorted for more than 5 sec to prevent excessive heating of the output resistor. The output will source up to 200mA when a short circuit is applied. 4. If a modulating signal is to be used, connect it to the Modulation Input connector (2) on the front panel. This signal will be amplified by a fixed voltage gain of -20. 5. Turn the power switch (1) on. At this point the amplifier is powered up but the HV Output is disabled. The power indicator should be illuminated. If not, check the AC fuse (see page 10). Confirm that the HV Enable LED (5) is off. 6. After confirming that all connections are correct, the amplifier output can be enabled by pressing the HV Enable button on the front panel (5). 7. Adjust the amplitude of the modulation signal as needed. 8. The DC level of the output can be shifted by adjusting the DC Bias Adjust control (3). Legend Table for Facing Page Legend Description 1 Main Power Switch 2 Modulation Input Signal - BNC 3 DC Bias Adjust Knob & Indicator Dial 4 HV Output Monitor - BNC 5 HV Enable Button 6 HV Output BNC (DANGER, High Voltage) 7 AC Input Connector IEC and Fuse Drawer 8 Cooling Fan 9 Line Voltage Selector Switch 18014-D02 Rev B, Jan 26, 2009 Page 6 www.thorlabs.com

3.1. HVA200 Controls and Features Figure 1: HVA200 Front Panel Features Figure 2: HVA200 Rear Panel Features 18014-D02 Rev B, Jan 26, 2009 Page 7 www.thorlabs.com

Part 4. HVA200 Specifications Physical Features Input Connector Specification HV Output Connector 2 Description BNC (± 10V, 10 ma) BNC (± 200V, 100 ma) HV Monitor Connector 3 BNC (± 10V, 200 ma, Min Load 50 Ω) Bias Adjustment Output Enable Output HV Indicator Power Switch Digital Encoder Front Panel Pushbutton Bright LED Rocker Switch Dimensions 9 x 5 x 12.5 228.6 mm x 127 mm x 317.5 mm Weight 11.6 lbs Other Tilting Rubber-Padded Feet Max Ratings: Max Output Current 100 ma DC Max Input Voltage Range -10 to 10 V Fuse Rating 630 ma @ 115 VAC (5x20 mm SLO-BLO) 400 ma @ 230 VAC (5x20 mm SLO-BLO) Operating Temperature Range 10 to 40 C, MAX 85% RH Electrical Characteristics Max. Input Voltage Range Input Impedance Output Voltage Output Impedance Slew Rate Output Noise -10 to 10 V 1 kω -200 to 200 V 50Ω 400 V/μs 1.5 mv RMS Voltage Gain 1-20 ± 2% DC Bias Adjust HV Monitor to Output Ratio: -200 to 200 V With Input Impedance of 50Ω 40:1 (Vout / 40 ± 6%) With Input Impedance of >10 kω 20:1 (Vout / 20 ± 6%) HV Monitor Output Impedance AC Power 50Ω 115V/230V, 50-60 Hz, 70 VA 1 The voltage gain is inverted to preserve the high slew rate of the output amplifier (i.e., a -1 V input results in +20 V output). 2 The HV output will handle an accidental short circuit without damage, but the output should not be shorted continuously. 3 The HV monitor output will handle accidental short circuits without damage, but must not be shorted for more than 5 sec to prevent excessive heating of the output resistor. The HV monitor output will source up to 200 ma when a short circuit is applied. 18014-D02 Rev B, Jan 26, 2009 Page 8 www.thorlabs.com

27 Typical Gain Bandwidth 24 18014-D02 Rev B, Jan 26, 2009 Page 9 www.thorlabs.com Voltage Gain (db) 21 Figure 3: Typical Gain Bandwidth 18 20 Vpp Input 10 Vpp Input 1 Vpp Input 15 10 100 1000 10000 100000 1000000 10000000 Frequency (Hz)

Part 5. Maintenance The HVA200 amplifier needs very little maintenance under normal operating conditions. There are no serviceable parts in the HVA200. The enclosure may be cleaned by wiping with a soft damp cloth. If you suspect a problem with your HVA200 please call Thorlabs and technical support will be happy to assist you. 5.1. Fuse Replacement The AC input is protected by a fuse located in a pull out compartment drawer on the rear panel AC connector. Refer to Figure 2 on page 7. If replacement is needed, disconnect the power cord from the back of the amplifier and pull the fuse compartment drawer out to expose the fuse. A small screwdriver may be used to pry the drawer open. Replace the fuse with the correct rating. Do not use a fuse with a current rating higher than the unit is rated for. The fuse ratings are as follows: 115V: 630 ma 5x20mm SLO-BLO 230V: 400 ma 5x20mm SLO-BLO 5.2. Ventilation For proper operation and protection of the output amplifier, it is important that the ventilation passages located on the sides and rear of the unit not be obstructed from free airflow. 5.3. Troubleshooting Problem PWR ON not illuminating, unit is not functioning Output will not enable, OUTPUT ON is flashing Solutions Check that the power switch in the on position, the mains connection is correct, and the fuse has not been damaged. The amplifier has gone into a protection mode because the circuitry has sensed that one of the HV supplies is not working correctly. 18014-D02 Rev B, Jan 26, 2009 Page 10 www.thorlabs.com

Part 6. Warranty Information General Product Warranty Thorlabs warrants that all products sold will be free from defects in material and workmanship, and will conform to the published specifications under normal use and service when correctly installed and maintained. Opto-Mechanics Lifetime Warranty: Thorlabs offers a lifetime warranty on all opto-mechanical components. Thorlabs will repair or replace any opto-mechanical product which after evaluation has failed to perform in the above conditions. Optical Tables and Breadboards Lifetime Warranty: We provide a lifetime guarantee that all of our passively damped optical tables and breadboards will meet all originally stated performance specifications under normal use and proper handling. We additionally guarantee that all our table tops and breadboards, both active and passive, will be free from defects in workmanship, including de-lamination of the skins under normal use and handling. Lasers and Imaging Systems Thorlabs offers a one year warranty on all lasers and imaging systems, with the exceptions of laser diodes. Some products are warranted for the number of hours specified in the operating manual of each laser. Opto-Electronics, Control Electronics, Optics, and Nano-Positioning Product Lines Thorlabs offers a two year warranty on the above mentioned product lines, provided normal use and maintenance of the products and when properly handled and correctly installed. Thorlabs shall repair or replace any defective or nonconforming product as detailed above. We ask that buyer contact Thorlabs for a Return Material Authorization number (RMA #) from our Customer Service/Returns department in order to most efficiently process the return and/or repair. Products returned for repair that are not covered under warranty, a Thorlabs standard repair charge shall be applicable in addition to all shipping expenses. This repair charge will be quoted to the customer before the work is performed. Warranty Exclusions The stated warranty does not apply to Products which are (a) specials, modifications, or customized items (including custom patch cables) meeting the specifications you provide; (b) ESD sensitive items whose static protection packaging has been opened; (c) items repaired, modified or altered by any party other than Thorlabs; (d) items used in conjunction with equipment not provided by, or acknowledged as compatible by, Thorlabs; (e) subjected to unusual physical, thermal, or electrical stress; (f) damaged due to improper installation, misuse, abuse, or storage; (g) damaged due to accident or negligence in use, storage, transportation or handling. 18014-D02 Rev B, Jan 26, 2009 Page 11 www.thorlabs.com

Part 7. Declaration of Conformity 18014-D02 Rev B, Jan 26, 2009 Page 12 www.thorlabs.com

Part 8. Regulatory As required by the WEEE (Waste Electrical and Electronic Equipment Directive) of the European Community and the corresponding national laws, Thorlabs offers all end users in the EC the possibility to return end of life units without incurring disposal charges. This offer is valid for Thorlabs electrical and electronic equipment: Sold after August 13, 2005 Marked correspondingly with the crossed out wheelie bin logo (see right) Sold to a company or institute within the EC Currently owned by a company or institute within the EC Still complete, not disassembled and not contaminated As the WEEE directive applies to self contained operational electrical and electronic products, this end of life take back Wheelie Bin Logo service does not refer to other Thorlabs products, such as: Pure OEM products, that means assemblies to be built into a unit by the user (e.g. OEM laser driver cards) Components Mechanics and optics Left over parts of units disassembled by the user (PCB s, housings etc.). If you wish to return a Thorlabs unit for waste recovery, please contact Thorlabs or your nearest dealer for further information. 8.1. Waste Treatment is Your Own Responsibility If you do not return an end of life unit to Thorlabs, you must hand it to a company specialized in waste recovery. Do not dispose of the unit in a litter bin or at a public waste disposal site. 8.2. Ecological Background It is well known that WEEE pollutes the environment by releasing toxic products during decomposition. The aim of the European RoHS directive is to reduce the content of toxic substances in electronic products in the future. The intent of the WEEE directive is to enforce the recycling of WEEE. A controlled recycling of end of live products will thereby avoid negative impacts on the environment. 18014-D02 Rev B, Jan 26, 2009 Page 13 www.thorlabs.com

Part 9. Thorlabs Worldwide Contacts USA, Canada, and South America Thorlabs, Inc. 435 Route 206 Newton, NJ 07860 USA Tel: 973-579-7227 Fax: 973-300-3600 www.thorlabs.com email: feedback@thorlabs.com Europe Thorlabs GmbH Hans-Böckler-Str. 6 85221 Dachau Germany Tel: +49-(0)8131-5956-0 Fax: +49-(0)8131-5956-99 www.thorlabs.com email: Europe@thorlabs.com Japan and Asia Thorlabs Japan Inc. 5-17-1, Ohtsuka Bunkyo-ku, Tokyo 112-0012 Japan Tel: +81-3-5977-8401 Fax: +81-3-5977-8402 www.thorlabs.jp email: sales@thorlabs.jp UK and Ireland Thorlabs LTD. 1 Saint Thomas Place, Ely Cambridgeshire CB7 4EX Great Britain Tel: +44 (0)1353-654440 Fax: +44 (0)1353-654444 www.thorlabs.com email: sales.uk@thorlabs.com Scandinavia Thorlabs Sweden AB Box 141 94 400 20 Göteborg Sweden Tel: +46-31-733-30-00 Fax: +46-31-703-40-45 www.thorlabs.com email: scandinavia@thorlabs.com 18014-D02 Rev B, Jan 26, 2009 Page 14 www.thorlabs.com

18014-D02 Rev B, Jan 26, 2009 Page 15 www.thorlabs.com

Thorlabs, Inc. 435 Route 206N Newton, NJ 07860 USA Phone: (973) 579-7227 Fax: (973) 300-3600 www.thorlabs.com