Pipeline Current Mapper



Similar documents
Pipeline Current Mapper

improved Best in class advanced pipe and cable location

Cable avoidance reaches a new level

Next Generation Cable Avoidance Tools

Utility cable and pipe locator

RD2000: SuperC.A.T + SuperC.A.T TL SuperC.A.T S SuperC.A.T CPS T1 Transmitter User Guide

Water leak detection products

Water leak detection products

Loc-1Tx/Loc-5Tx/Loc-10Tx Data Sheet V3.3

Dynatel 2273 Advanced Cable and Fault Locator

TDR900. Hand-held Time Domain Reflectometer/Cable Length Meter TDR900. Hand-held Time Domain Reflectometer/Cable Length Meter

Multi-Function Ground

Leica DIGISYSTEM TM Safe and fast location of underground services

Handheld portable appliance testers

APC Matrix-UPS 5kVA 208V/240V In 120/208/240V Out

User's Guide. Integrating Sound Level Datalogger. Model Introduction

VOLTAGE/CURRENT CALIBRATOR ISO-TECH ILC-421

Advanced Systems Tester 900AST

German Cathodic Protection REMOTE MONITORING AND CONTROL

5000V Graphical Megohmmeter Model 5070

Everything you need for protection scheme testing

Perimeter Security System

Ground Resistance Clamp On Tester

PowerGem Pro Uninterruptible Power Supply

Cable And Pipe Signal Receiver

DC Electronic Loads 8500 series

Microwave Meter. Instruction Manual

Digital Ground Resistance Tester. Models 4620 & Digital Ground Resistance Tester

Agilent N2717A Service Software Performance Verification and Adjustment Software for the Agilent ESA Spectrum Analyzers Product Overview

Instruments for the oil & gas industry

Using R&S NRP-Z Power Sensors with Android TM Handheld Devices. Application Note. Products:

INTREPID Perimeter Intrusion Detection System

FiberBasix 50 Handheld Testers Series comprising the els-50 light source and epm-50 power meter

Agilent E363xA Series Programmable DC Power Supplies. Data Sheet

Guide. Installation. Signal Booster. Wilson. In-Building Wireless Smart Technology Signal Booster. Contents:

INSTRUCTION MANUAL PLEASE READ ALL THE INSTRUCTIONS COMPLETELY BEFORE USE AND SAVE THIS MANUAL FOR FUTURE REFERENCE

CellAdvisor. JD725A Dual-Port Cable and Antenna Analyzer

AGRI-ALERT 128 TOUCH AGRI-ALERT 800EZE ALARM SYSTEMS

1587/1577. Insulation Multimeters. Technical Data. Two powerful tools in one.

BASIC SOUND LEVEL METERS

Agilent 4338B Milliohm Meter

USB Smart Power Sensor

HDMI over Cat5 Video Extender with RS232 and IR Control

PAT120, PAT150 and PAT150R Handheld portable appliance testers

LTR Series Uninterruptible Power Systems 700 VA KVA. General Specification

Agilent 8753ET/8753ES Network Analyzers

DRTS 33. The new generation of advanced test equipments for Relays, Energy meters, Transducers and Power quality meters

T-BERD 107A. T-Carrier Analyzer

GSM Alarm System User Manual

Model UT713 OPERATING MANUAL

DM70 Hand-Held Dewpoint Meter for Spot-Checking Applications

USB Smart Power Sensor

Wahl C50 Calibrator FEATURES

Ron 3025 Crane Scale with 1"/25mm Display

G-PORTER. Portable GPS Tracker GP-102 User s Manual

Hand-held thermometer Model CTH7000

PSM 900 and PSM 1000 Personal Monitor Systems TWO SYSTEMS. INFINITE POSSIBILITIES.

MicroScanner 2. Cable Verifier. Getting Started Guide

Agilent 87421A/87422A Power Supply

LT-82 Stationary IR Transmitter

PowerCommand iwatch 100

AIS 3000 APC AIS kVA 208V w/2 Batt. Module Exp. To 4, Start-Up 5X8, Internal Maintenance Bypass

ARES II ADVANCED MULTI - CHANNEL AUTOMATIC RESISTIVITY & IP SYSTEM

User Guide. Soft-Touch TM Bluetooth Laser Mouse N2953

Tower Mounted Amplifiers, Diagnostics and Isolation Measurements

etrex 10 quick start manual

Poor quality welds Machine downtime High maintenance costs Lost revenue

Digital Transformer Ratiometer DTR Model 8500

DDX 7000 & Digital Partial Discharge Detectors FEATURES APPLICATIONS

Industrial-Grade UPS System Heavy-duty power protection for harsh industrial environments

Voltech DC1000. Precision DC Bias Current Source

MASTR III RF Package, VHF

PHANTOM 2 Product Release Notes

Electro-Magnetic Flowmeters COPA-XT 2-Wire DT43

How To Sell A Talan

2.4G Bluetooth Datalink & ipad Ground Station User Guide V1.02

A full range of monitoring solutions for surge arresters Answers for energy.

WIRELESS INSTRUMENTATION TECHNOLOGY

Distance-To-Fault (DTF) Measurement in 75 Ohm Systems with the R&S FSH3-TV

Dialight Control and Monitoring System for Vigilant LED Based Obstruction System for High Intensity Installations. FAA Type B FAA Type C FAA Type F

R&S EFL110/ R&S EFL210 Cable TV Analyzer and Leakage Detector Detecting interference in cable TV and LTE networks

HDCATS-100. Installation Guide

DREXELBROOK. USonic-R Series. Ultrasonic Level Measurement System. User Friendly

A-307. Mobile Data Terminal. Android OS Platform Datasheet

Agilent 4339B/4349B High Resistance Meters

RISH CON - Hz. Salient Features : Application : Product Features: FREQUENCY TRANSDUCER

SP1790JK 900MHz Wireless Indoor/Outdoor Speakers. User Manual INTRODUCTION FEATURES IMPORTANT SAFETY INFORMATION

i5000 Utility Locating System 10W Transmitter SERVICE CENTER, SALES AND TECHNICAL SUPPORT INFORMATION

S a f e G u i d a n c e. Single Lamp Control and Monitoring

Light Meter (Foot Candles)

Alarm Systems. Peace of Mind. Agri-Alert alarms have been protecting swine operations across the world since automated production systems

Multifunction devices

HDTV Anywhere USER MANUAL / HDTV Anywhere ALL RIGHTS RESERVED MARMITEK

Insulation resistance testing. A complete solution for every person.

Nardalert S3 Non-Ionizing Radiation Monitor

Mobile Communications DC Sources W

MN1010 Evaluation Kit v3 User Guide

Fiber Optic and Isolation Solutions for Renewable Energy Applications

FC6 FOOT CONTROLLER OWNER S MANUAL

Spectrum Analyzer Two models available: OGR-24 (24 GHz) and OGR-8 (8 GHz)

Transcription:

Pipeline Current Mapper

Fast locate and effective diagnosis of faults in cathodic protection systems Worldwide, concerns on protecting the environment are getting more media coverage. Utilities are rescheduling their capex giving existing pipelines a longer and longer life. There is now a legal requirement for operators to accurately map the locations of pipelines and periodically assess their condition and integrity. The location and measurement of centrelines using electromagnetic detection devices (Locators) are increasingly being linked with GIS systems and GPS information derived from commercially available equipment, to provide an accurate record of the centerline of pipes and the x,y,z and time co-ordinates for post mapping analysis this requirement is the basis of the PCM +... The PCM + System consists of a portable transmitter and a hand held receiver. The transmitter connected at the CPS station, applies a special near DC signal to the pipeline. The receiver locates this unique signal at distances up to 30km (19 miles) identifying the position and depth of the pipe. Once the pipe has been located then the technician can map the leakage currents along the pipe and displaying the signal s current magnitude and direction allowing coating defects to be quickly identified: Once the segment of pipeline where the fault lies has been identified, by using an A-frame, the fault position and depth can be further pinpointed to within 1 meter (3 feet). The PCM + accurately and easily locates and maps the pipeline even in areas where there is contact with other metallic structures, electrical interference, or congestion, providing simultaneous measurement of PCM current (ACCA) and Voltage Gradient (ACVG). This eliminates the need for the operator to perform current spans and manual calculations to determine CP currents along a pipeline that would usually require a direct connection. Each time the PCM + maps in any of the modes, as well as storing and displaying the information on the Receiver, all the data gathered can be sent via Bluetooth to either a PC or an optional PDA (with GPS), and displayed in a number of graphical formats for fast analysis. The PCM + and its accessory equipment provide any Pipeline technician with the latest in accurate, fast and reliable pipeline current mapping tools PCM + Receiver features n Precision Locator and PCM in one unit Accurate, high over-sampled measurements, 96000 Samples/sec 8kHz Fault Find Improves fault indication integrity Minimizes unnecessary excavations n Current mapping Quicker 3 second ACCA mapping and up to 1000 logs n Real time upload of mapped data via Bluetooth to PDA or PC n Key graph mapping modes Locate depth Locate current (ma and dbma) ACCA PCM current (ma and dbma) Phase ACVG n Unique features to improve data integrity ASA Automatic Signal Attenuation ACD Advanced Current Direction AGC Adaptive Ground Compensation n Identification of pickup/discharging from 3rd party CP Systems n Free analysis software for PDA and PC Integrates with standard GIS software n Low power for full day survey n Backlight n Real sound PCM-Tx Transmitter features n One portable case n Easy to use n High power 150 Watt n 30km (19 miles) range @ 4Hz n New programmable, digital processor based for reliability n Improved overload protection n Negative drive voltage n Optional switch around zero for full power limited duration n Improved environmental sealing T10 Transmitter features n One case n Easy to use n Low power 10 Watt n 5km (3 miles) range @ 4Hz n 8kHz Fault Find

PCM + Receiver HIGH CONTRAST DISPLAY The hand held receiver unit is used to locate the pipeline, even in heavily congested areas, and then provides the operator with a measurement of depth current strength and direction of the near DC signal applied by the system s transmitter. The receiver makes the required calculations and instantaneously displays the results. This provides the operator with an improved method that accurately troubleshoots the CP system by pinpointing metallic contacts and locating areas of coating defects. SELF ORIENTING FOOT MULTI-FUNCTION TACTILE KEYPAD MULTI-SIGNAL RESPONSE Peak and null, left and right weather sealed Earphone and accessory ports choice of batteries Dry cells or rechargeable options REAL TIME graphical view of mapping results as mapping proceeds engineered PLASTICS Ergonomic, robust and all weather housing Real time mapping analysis (PDA or PC) using Radiodetection GML Survey software To provide faster analysis of mapped information, the PCM + connects wirelessly with a PDA or PC, uploading all the information immediately and linking it with GPS into a database using the Radiodetection GML Survey software. The database is updated after each mapping and can be seen immediately on the PC or PDA in either a database or a choice of graphical formats. The information can then be imported into most of the standard post processing software programs available. The GML software incorporates GPS information and shows the mapped data in a variety of formats as well as allowing comparisons between new and old mapping surveys. For more details go to www.radiodetection.com

PCM-Tx Transmitter The PCM + system s specialized constant current high-power transmitter allows for long range signal detection of up to 30km (19 miles). Significantly fewer pipeline connection points are needed thereby reducing the time required to evaluate a section of pipeline. The transmitter has three operating modes that enable both distribution and transmission pipeline systems to be effectively mapped. Connecting the PCM + is straightforward, and the transmitter s current reading DISPLAY and power indicating LED s help the operator to choose the best settings for the specific pipeline application. A-frame The accessory A-Frame is used with the PCM + receiver to precisely pinpoint coating defects and isolation faults. The PCM + receiver display indicates direction to the fault, using the CD direction arrows, and this makes fault position easy to locate. The PCM + also displays the db microvolts reading across the A-Frame spikes, and this allows a comparison to be made between different faults to determine the most severe. This numeric value is stored in the PCM s datalogging facility, and uploaded via Bluetooth to a PDA or PC. locate l measure l store l upload l review l analyse

Pipeline Current Mapper Data upload Interference rejection High power Tx 30 km (19 miles) Fast location with accurate mapping, minimizes unnecessary excavations Bluetooth link to PDA/PC for real time logging with GPS into Radiodetection GML Application DSP based algorithms enable filtering of false signals even in areas where there is contact with other metallic structures Fewer connection points speeds up survey time over long distances Technical Specifications PCM + Receiver MAPPING MODES ELF Extra Low Frequency 128Hz/98Hz LF Low Frequency 640Hz/512Hz 8 khz Standard locate frequency from battery powered Radiodetection transmitters NB: Current Direction ( FF) arrows are displayed only with the PCM measurement, and not in locate modes, unless the PCM is supplied with CD frequency. n Dynamic Range: n Selectivity: n Range from Tx: n Depth accuracy: 140dB 120dB/Hz 30km (19 miles) 2.5% to 3 meters (10ft); ± 5% to 10 meters (33ft) in good conditions n Current accuracy: ± 2.5% n Locate accuracy: ± 2.5% of depth n Weight: 3.3Kg (7.2lb) n Batteries: 2 D cells (Alkaline or NiMH) n Environmental: IP54 n Approvals: CE, Bluetooth compliant LOCATE MODES Detects 50Hz/60Hz from power cables CPS Detects 100Hz/120Hz ripple from CP transformer rectifier 8 khz Standard locate frequency from battery powered Radiodetection transmitters Peak/Null n Used to pinpoint target line n Simultaneous peak & null response n Gain control: Via keypad auto & manual PCM-Tx Transmitter Frequency Select The 4Hz output current is shown on the LCD. Applied mapping frequencies as follows: ELF maximum range ELF current direction LF current direction 4Hz* 4Hz* 4Hz* ELF (128Hz or 98Hz) 8Hz (current direction) 8Hz (current direction) ELF (128Hz or 98Hz) LF (640Hz or 512Hz) n Case construction: High impact engineered plastics n Weight: 15.2kg (34lb) n Size: 47 x 37 x 19cm (18.5 x 14.5 x 7.5 inch) n Environmental: NEMA 3R and IP55 lid open; NEMA 6 and IP67 lid closed n Approvals: CE *The 4Hz mapping frequency is always present. The operator has a choice of selecting the locate frequency and current direction indication if required for identification in congested areas or for fault finding. Current Select The six position (current select) rotary switch selects the following 4Hz current settings: 100mA, 300mA, 600mA, 1A, 2A, 3A. When the PCM Transmitter is in operation, the selected current will remain at a constant level, unless the input power supply limit is reached. PCM Attachment (A-frame ) A-frame for detection of sheath faults on buried pipes and cables (includes PCM + connection cable). n Weight: n Size: 1.55kg (3.4lb) 8.5 x 59 x 4.5cm (33 x 39.3 x 1.7 inch)

World leaders Technical support Servicing and repair Training Radiodetection is a proud member of the SPX group of companies, which provide technical products and service solutions worldwide. Radiodetection and its associated companies specialize in the design and manufacture of products for the location and maintenance of underground pipes and cables. Our aim is to be viewed as the supplier of choice of high performance quality equipment using advanced product technologies. We are also committed to both design innovation and customer support. Radiodetection equipment users have easy access to technical support. A call to your regional representative, or the Radiodetection head office, will put you in contact with our team of field-experienced technical experts. Radiodetection has a team of factory-trained service technicians and dedicated service facilities accredited to ISO 9000. Turnaround is fast, and costs are very competitive. All repairs carry a six month warranty. Product training for your operators and training personnel is available on your site, or at Radiodetection s headquarters. Training is with qualified instructors and each trainee receives a certificate to confirm they have received the training. America Radiodetection 154 Portland Road Bridgton, ME 04009, USA Tel: +1 (207) 647 9495 Toll Free: +1 (877) 247 3797 Fax: +1 (207) 647 9496 Email: bridgton@radiodetection.spx.com Pearpoint Inc 72055 Corporate Way Thousand Palms CA 92276, USA Tel: +1 800 688 8094 Tel: +1 760 343 7350 Fax: +1 760 343 7351 Radiodetection Canada Ltd. Unit 34, 344 Edgeley Blvd. Concord, Ontario, Canada L4K 4B7 Tel: +1 (905) 660 9995 Toll Free: +1 (800) 665 7953 Fax: +1 (905) 660 9579 Europe Radiodetection Ltd. Western Drive Bristol BS14 0AF, UK Tel: +44 (0) 117 976 7776 Fax: +44 (0) 117 976 7775 Email: sales.uk@radiodetection.spx.com Radiodetection Sarl 13 Grande Rue, 76220 Neuf Marché, France Tel: +33 (0) 232 8993 60 Fax: +33 (0) 235 9095 58 Radiodetection CE, Continental Europe Industriestraat 11, NL 7041 GD s-heerenberg, Netherlands Tel: +31 (0) 314 66 47 00 Fax: +31 (0) 314 66 41 30 Email: info@radiodetection.nl Asia-Pacific Radiodetection (Asia-Pacific) Room 708, CC Wu Building 302-308 Hennessy Road, Wan Chai Hong Kong SAR, China Tel: +852 2110 8160 Fax: +852 2110 9681 Email: chinasales@radiodetection.spx.com Radiodetection (China) Hong Fu Group Office Building Room 322-326 Bei Qi Jia Township, Changping District Beijing 102209, China Tel: +86 (0) 10 8975 5540 Fax: +86 (0) 10 8975 5640 Email: china.service@radiodetection.spx.com Mactek Pty. Limited A Subsidiary of Radiodetection Ltd. Unit 14, 5-7 Prosperity Parade Warriewood NSW 2102, Australia Tel: +61 (0) 2 9979 8555 Fax: +61 (0) 2 9979 7733 Email: mactek@mactek.com.au To see the full range of products and services provided by Radiodetection visit: www.radiodetection.com Radiodetection products are under continuous development and are subject to change, we reserve the right to alter or amend any published specification without notice. PCM + is a Trademarks of Radiodetection Ltd. Copyright 2007 Radiodetection Limited. All rights reserved. Radiodetection Ltd. is a subsidiary of SPX Corporation. 90/PCMPlus/ENG/01