How To Build A Wall System



Similar documents
SPECIFICATIONS FOR PRECAST MODULAR BLOCK RETAINING WALL SYSTEM (revised 11/5/13)

Design Ideas by Allan Block

CONCRETE SEGMENTAL RETAINING WALL SYSTEM

RETAINING WALL CONSTRUCTION DETAILS 2006 ESTIMATING AND INSTALLATION MANUAL. Featuring Highland Stone. anchorwall.com

Specification Guidelines: Allan Block Modular Retaining Wall Systems

CONCRETE SEGMENTAL RETAINING WALL SYSTEM

Interlocking Concrete Paving Stones

State of Illinois Department Of Transportation CONSTRUCTION INSPECTOR S CHECKLIST FOR STORM SEWERS

Note: All dimensions are nominal. All weights are for shipping purposes only. Availability is subject to change.

Seven. Easy Steps. Your Own Walkway, Without Mortar. or Concrete. to Installing. Driveway and Patio

DESIGN GUIDELINES FOR EARTH RETENTION

Interlocking Concrete Paving Stones

AB Courtyard Collection

Gas Meter Clearances and Service Installation Requirements

How to Install Pavers

How to build raised beds page

SECTION 55 PIPE FOR STORM DRAINS AND CULVERTS (FAA D-701)

The Verdura Wall check with your local building department

Guidelines for Rights of Way

SECTION CONCRETE SEGMENTAL RETAINING WALL SYSTEM

CITY OF VAUGHAN SCHEDULE O LOT GRADING DESIGN FOR RESIDENTIAL DEVELOPMENT

How to Build a Dry Stone Wall

Installation PowerPoint for Grasscrete Formers

SIENA STONE GRAVITY RETAINING WALL INSTALLATION SPECIFICATIONS. Prepared by Risi Stone Systems Used by permission.

1 yard per sq. 2 Depth. Color is a personal choice. Dye fades due to sunlight. Although color remains, fading begins to occur

Dimensional and Structural Data for Elliptical Pipes. PD 26 rev D 21/09/05

Hydraulic Excavators

Storm Drain Inlet Protection - IP

Specifications for Residential Property Owners Connection to New Public Sewer

SECTION CONCRETE SEGMENTAL RETAINING WALL SYSTEM

Free-Form Concrete Pool

Team Skills Challenge Event # 1 Plant Layout Score Sheet

Watershed Works Manual

1. ASTM C Sampling and Testing Concrete Masonry Units 2. ASTM C 1372 Standard Specification for Dry-Cast Segmental Retaining Wall Units

Index. protection. excavated drop inlet protection (Temporary) Block and gravel inlet Protection (Temporary)

Gas Meter Clearances and Service Installation Requirements

SECTION GRAVITY SANITARY SEWERS

CW 3110 SUB-GRADE, SUB-BASE AND BASE COURSE CONSTRUCTION TABLE OF CONTENTS

SECTION EARTH MOVING

DRAINAGE MATS For Vertical: Flow 15-P For Horizontal: Flow 18-H

MOBILE HOME LAW. Revised November 2001

Building Your Interlocking Concrete Pavement to Last a Lifetime

INSTALLATION GUIDE. americanwick.com WICK (9425)

SHAFT CONSTRUCTION IN TORONTO USING SLURRY WALLS

Basic Elements of Reading Plans

SOMETIMES the cost of installing a landscape plan

RESIDENTIAL FOUNDATION GUIDELINE Johnson County, KS

Block and Gravel Inlet Protection (BIP)

Metropolitan Builders Association Masonry & Concrete Standard

THE OBJECTIVES OF ROUTINE ROAD CUTS AND FILLS

Chapter 3 Pre-Installation, Foundations and Piers

RIPRAP From Massachusetts Erosion and Sediment Control Guidelines for Urban and Suburban Areas

Fiberstars Mini Lighted Laminar Flow Fountains

SECTION PERMEABLE INTERLOCKING CONCRETE PAVEMENT

3. Contractor shall ensure that all permits are obtained prior to any construction. Contractor shall be responsible for all utility fees.

Fiberstars Lighted Laminar Flow Fountain Installation Manual

The better way to build TM. Installation Manual. FOUNDATION SIPs & FROST WALLS SIPs

Table 4.9 Storm Drain Inlet Protetion Applicable for

Florida Building Code 2004 SECTION 1009 STAIRWAYS AND HANDRAILS

SECTION STORM DRAINAGE STRUCTURES. 1. Trench excavation, backfill, and compaction; Section

The work of this Section includes furnishing and installing Reinforced Concrete Pressure Pipe as shown on the Drawings and as specified.

Emergency Spillways (Sediment basins)

SPECIFICATION FOR PIPE SUBSOIL DRAIN CONSTRUCTION

Module 7 (Lecture 24 to 28) RETAINING WALLS

Lighthouse Engineering, L.L.C.

DESCRIPTION OF WORK:

Sheet Metal Bending. By- Prem Mahendranathan

Division 2 Section Section 02795

BMP-7. A sediment filter or an excavated impounding area around a storm drain drop inlet or curb inlet.

Chapter 3 Installing Over-the-Post Railing on an L-Shaped Stair

Storm Drain Inlet Protection

Soakage Trenches. A better way to manage stormwater. Thinking Globally and Acting Locally

glass & Glazing Products

Storm Drain Inlet Protection

40-9 PERMEABLE INTERLOCKING CONCRETE PAVEMENT

APPLICATION FOR DEMOLITION & RIGHT-OF OF-WAY PERMIT

PERMEABLE INTERLOCKING CONCRETE PAVEMENT

SECTION PERMEABLE INTERLOCKING CONCRETE PAVEMENT (1995 MasterFormat Section 02795)

Installation Guidelines for Segmental Block Wall. Contents 1. INTRODUCTION MATERIALS... 2

Permeable Pavement Construction Guide

SE-10 STORM DRAIN INLET PROTECTION. Objectives

SEPTIC SYSTEM CONSTRUCTION REQUIREMENTS ST. MARY S COUNTY HEALTH DEPARTMENT

Section 2 Specification 2.18 Concrete and/or Corrugated Steel Storm Sewer TABLE OF CONTENTS

Precast Modular Block (PMB) for Retaining Wall Systems

Safe & Sound Bridge Terminology

Residential Deck Safety, Construction, and Repair

SANITARY SEWER SERVICE CONNECTION INSTRUCTIONS

SPECIFICATIONS. INTERLOCKING CONCRETE POROUS PAVING UNITS or Permeable Interlocking Concrete Pavers (PICP)

301.7D. Mini Hydraulic Excavator

STANDARD AND SPECIFICATIONS FOR STORM DRAIN INLET PROTECTION

LAYING BLOCK AND BRICK

COMMONLY USED RESIDENTIAL BUILDING CODES

Stair Parts Installation. Tricks

LS 2540 SEWER LATERALS AND INSPECTION TEES

Caltrans non-standard Special Provisions Pervious Concrete. David Akers Feb 28, 2012

C. Section TESTING LABORATORY SERVICE.

PART TWO GEOSYNTHETIC SOIL REINFORCEMENT. Martin Street Improvements, Fredonia, Wisconsin; Keystone Compac Hewnstone

General (1) This Section applies to the design and construction of interior and exterior stairs, steps, ramps, railings and guards.

Transcription:

KEYSTONE RETAINING WALL SYSTEMS HARDSCAPE PRODUCTS CONSTRUCTION SUPPLIES CONCRETE BLOCKS PRECAST PRODUCTS MAIN OFFICE 28 Old Rt. 27 Rd. Belgrade, ME 04917 (800) 339-3313 270 Riverside Drive Auburn, ME 04210 (800) 339-1132 70 Warren Avenue Westbrook, ME 04092 (800) 339-9184 195 North Street Saco, ME 04072 (800) 244-2742 15 Route 236 Kittery, ME 03904 (800) 439-9504 293 Lewiston Road Topsham, ME 04086 (800) 227-5776 96 Roosevelt Trail Naples, ME 04055 (207) 693-5355

INTRODUCTION GAGNE & SON has been family owned and operated since its establishment in 1945. Our company manufactures concrete products and provides extensive hardscape and construction product lines for Northern New England. Our recent recognition from the Kennebec Valley Chamber of Commerce as the "2007 Business of the Year" demonstrates our dedication and drive to provide you with quality products and outstanding service. KEYSTONE RETAINING WALL SYSTEMS, INC. has set the standard for excellence and innovation within the segmental retaining wall industry for over 20 years. Keystone represents the global benchmark in soil retention, erosion control, and landscape systems. Holding over 50 patents, Keystone symbolizes cutting-edge design, performance, and aesthetics. TABLE OF CONTENTS Keystone Compac Unit................... 3 Keystone Mini Unit...................... 4 Keystone Accessories..................... 5 Keystone Verazzo Stone................. 6-7 Keystone Arbor Stone.................... 8 Product Installation...................... 9 Corners & Curves.................... 10-11 2

KEYSTONE COMPAC UNIT Keystone Compac Unit As a gravity wall or reinforced structure, the Keystone Compac Unit provides a structurally sound, aesthetically appealing and economically beneficial solution. The Keystone Compac Unit features an open core design and high strength pin connection system. Its light weight and short tail design make it easy for installers to handle. 8" Compac Rockface Dimensions: 8" x 12" x 18" #430710 Natural #430700 Brown #430720 Charcoal 8" Compac Straightface Dimensions: 8" x 12" x 18" #430750 Natural #430730 Brown #430740 Charcoal 3

KEYSTONE MINI UNITS Keystone Mini Unit The Keystone Mini Unit is a great solution for smaller, non-critical applications. It is easy to handle and install, and makes for an attractive wall on its own or as an accent when integrated with the 8" high Compac units. The proportion and scale of the Mini units blend well with brick and ledge stone typically found in residential construction. 4" Mini Rockface Dimensions: 4" x 10.5" x 18" #430570 Natural #430590 Brown #430580 Charcoal 4" Mini Straightface Dimensions: 4" x 10.5" x 18" #430600 Natural #430610 Brown #430620 Charcoal 4

KEYSTONE WALL ACCESSORIES Universal Cap 8" Corner Unit 4" Corner Unit Dimensions: 4" x 10.5" x 18" #430420 Natural #430430 Brown #430440 Charcoal Dimensions: 8" x 9" x 18" #430810 Natural #430820 Brown #430800 Charcoal Dimensions: 4" x 9" x 18" #430630 Natural #430640 Brown #430650 Charcoal 8" Step Tread 4" Step Tread Dimensions: 8" x 18" x 18" #430830 Natural #430840 Brown #430850 Charcoal Dimensions: 4" x 18" x 18" #430660 Natural #430670 Brown #430680 Charcoal AVAILABLE COLORS Keystone Natural Keystone Chestnut Brown Keystone Charcoal 5

NEW! KEYSTONE VERAZZO STONE Rugged look and feel Design Versatility Easy Installation Units are angled on both sides Ability to blend in with any landscape Unmatched Strength & Stability WALL LENGTH (measured at wall face including curves) ONE-PIECE SYSTEM 6" H x 10.5" D x 16/12-5/16" W Total Pallet = 45 Units Sold by the unit 1.5 units/sq. ft. Single-sided wall = 16"/unit Double-sided wall = 14"/unit 2 molded pins required per unit 2-3/8" (60 mm) total length 1" (26 mm) shoulder length WALL HEIGHT* 4' 8' 12' 16' 20' 24' 6" (1 course) 4 8 12 16 20 24 12" (2 courses) 8 16 24 32 40 48 18" (3 courses) 12 24 36 48 60 72 24" (4 courses) 16 32 48 64 80 96 30" (5 courses) 20 40 60 80 100 120 36" (6 courses) 24 48 72 96 120 144 Maximum Height Vertical Position Maximum Height Setback Position *Notes: Maximum wall height not to exceed 36". The maximum height is based on a level grade, total granular soil, wall built in setback position, and no surcharge. Contact your local Keystone representative for design options on wall heights exceeding 36" or supporting surcharges and backslope. Change in color on chart denotes maximum wall height for vertical and setback positions. Keystone recommends cap units as the top course and/or caps of freestanding walls secured with Keystone KapSeal adhesive. Step 1» Prepare the site. Step 2» Set the base course. Step 3» Pin, stack, and fill. Start by digging a shallow trench 12" deep by 24" wide. Cut through and remove any sod, roots or large rocks. Place 6" leveling pad of compacted sand or gravel in the trench to receive the first course of Keystone Verazzo Stone. Place and level the first Keystone Verazzo Stone unit. Level each additional unit on the base course as you place it, making sure that the outside edges touch. If your wall contains both straight and curved areas, start with a straight area and build into the curves. Complete the base course before proceeding to the second course. *Note: For straight line walls, unit faces can be alternated to create a more random look. Starting with straight areas first, begin placing the second course. Center each Keystone Verazzo Stone unit over the pins on the joints of the course below in a running bond pattern as shown. Now proceed to the next layer, backfilling as you go. For drainage between units and behind the wall, clean gravel or crushed stone is recommended. 6

KEYSTONE VERAZZO STONE 6" THREE-PIECE SYSTEM 6" H x 10.5" D x 16/13.83" W 6" H x 10.5" D x 10/7.9" W 6" H x 10.5" D x 6/3.9" W 2 molded pins required per unit 2-3/8" (60 mm) total length 1" (26 mm) shoulder length Total Pallet = 30 sq. ft. 5 rows of 6 sq. ft./pallet Sold by the layer Fieldstone Blend 3" THREE-PIECE SYSTEM Granite Hill Blend 3" H x 10.5" D x 16/13.83" W 3" H x 10.5" D x 10/7.9" W 3" H x 10.5" D x 6/3.9" W 2 molded pins required per unit 2-3/8" (60 mm) total length 1" (26 mm) shoulder length Total Pallet = 24 sq. ft. 8 rows of 3 sq. ft./pallet Sold by the layer 7

KEYSTONE ARBOR STONE Easy to Install Adds Beauty Offers Design Versatility Long-Lasting & Durable Perfect for Patio, Lawn or Sidewalk Edging Unit Dimensions: 12"L x 9"W x 4"D Each Keystone Arbor Stone unit weighs approximately 29 pounds, making it fast and easy to install by yourself. WALL WALL LENGTH (measured at wall face including curves) HEIGHT 5' 10' 15' 20' 25' 30' 4" (1 course) 5 10 15 20 25 30 8" (2 courses) 10 20 30 40 50 60 12" (3 courses) 15 30 45 60 75 90 16" (4 courses) 20 40 60 80 100 120 20" (5 courses) 25 50 75 100 125 150 24" (6 courses) 30 60 90 120 150 180 Please Note: Maximum wall height not to exceed 2'. This chart is based on site conditions which include a level grade, granular soil and no surcharge. Contact Keystone Retaining Wall Systems for design options and patented soil reinforcement guidelines on wall heights exceeding 2'. Add beauty to any home or garden landscape in 3 easy steps! Step 1» Prepare the site. Step 2» Set the base course. Step 3» Stack and fill. Start by digging a shallow trench 4" deep by 12" wide. Cut through and remove any sod, roots or large rocks. For organic loam soils, dig 4" deeper and add a leveling pad of sand or gravel. Compact and level the soil to receive the first course of Keystone Arbor Stone. Place and level the first Keystone Arbor Stone unit. Level each additional unit on the base course as you place it, making sure that the outside edges touch. If your wall contains both straight and curved areas, start with a straight area and build into the curves. Complete the base course before proceeding to the second course. Starting with straight areas first, begin placing the second course. Center each Keystone Arbor Stone unit on the seams of the course below in a running bond pattern as shown. Now proceed to the next layer, backfilling as you go. For drainage behind the wall, clean gravel or crushed stone is recommended. 8

PRODUCT INSTALLATION The Keystone Retaining Wall System was developed with simplicity of construction in mind. These step-by-step instructions will guide you through the basic process from start to finish. If more detailed information is required to meet your specific site situation, consult your local Keystone representative. Step 1» Prepare the Base Leveling Pad. Start the leveling pad at the lowest elevation of the wall. Level the prepared base with 6" of well-compacted granular fill (gravel, road base, or 1 /2" to 3 /4" [13-20 mm] crushed stone). The base trench should be wide enough to allow for the Keystone unit and drainage zone. Step 4» Install and Compact Backfill. Fill in all voids in and between Keystone units using 1/2" to 3 /4" (13-20 mm) crushed stone or clean, well-draining granular fill. Place drain zone behind the units as required to achieve total 2 ft. (0.6 m) depth of drainage zone from unit face. Peagravel should not be used. Sweep off any pebbles or debris so the next Keystone units rest evenly upon the layer below. Step 2» Install the Base Course. Place the first course of Keystone units side by side (with sides touching) on the prepared base, with the paired pin holes facing up. Make sure each unit is level side to side and front to back. The first course is critical for accurate and acceptable results. Step 5» Install Additional Course. Place the next course of Keystone units over the fiberglass pins, fitting the pins into the kidney-shaped recesses. Center the unit over the two underlying units as shown.visually sight down in the kidney-shaped recess for pin positioning. Pull the Keystone unit toward the face of the wall until it makes full contact with both pins. For each remaining course, repeat Steps 3-6. Step 3» Insert Interlocking Fiberglass Pins. Place the reinforced fiberglass pins into the paired holes (2) of each Keystone unit. (Pins of adjoining units should be 12" [305 mm] on center.) Once placed, the pins create an automatic setback for the additional courses. Step 6» Install Keystone Caps. Complete your wall with Keystone Caps. In areasof high public usage, apply Keystone KapSeal (a construction adhesive for masonry units) on the top surface of the last course before applying cap units. Place the Keystone Cap unit over the pins on the underlying unit. Pull the Cap unit forward to the automatic setback position. GEOGRID INSTALLATION For taller or more critical walls that require use of geogrid, continue with the following installation process after Step 4. Step 7A» Excavate Reinforced Soil Area. Remove existing soils in the reinforced soil area to the maximum embedment length of the geogrid design. Provide a generally level soil condition behind the wall units for the placement of each geogrid layer. Step 7B» Cut Geogrid. Cut sections from geogrid roll to the specified length (embedment depth). Geogrid roll direction is from the wall toward the embankment. Check manufacturer s criteria for biaxial or uniaxial geogrids. In most cases correct orientation is to roll the geogrid perpendicular to the wall face. Step 7C» Install Geogrid. Hook geogrid over the Keystone fiberglass pins to ensure a positive mechanical connection between the unit and geogrid. Step 7D» Secure Geogrid. Pull the pinned geogrid taut to eliminate loose folds. Stake or secure back edge of geogrid before and during backfill and compaction. Remove stakes, if desired, once backfill is placed. Place additional sections of geogrid, abutting each other, for continuous coverage at each layer. Step 7E» Install Next Course of Keystone Units. Step 7F» Place Compacted Backfill Over Geogrid in 8" Lifts. Provide a minimum of 6" (150mm) reinforced fill coverage prior to driving equipment over the geogrid with tired equipment. Avoid driving or turning vehicles directly on geogrid to avoid excessive damage. 9

CORNERS & CURVES 90 OUTSIDE CORNER USING NEAR VERTICAL SETBACK The following information will provide a general explanation of construction techniques for building retaining walls with these conditions. INSTALLATION PROCEDURES: Follow standard installation instructions for preparation of sub grade and leveling pad. Construction can start at the corner and work away from this point or with the method shown below, the wall can be started elsewhere and worked into the corner. This detail gives the builder flexibility. 3-PLANE SPLIT UNITS FIRST COURSE SECOND COURSE CAP COURSE STRAIGHT SPLIT UNITS FIRST COURSE SECOND COURSE CAP COURSE 10

CORNERS & CURVES QUESTION: ANSWER: When building an inside 90 corner, how much should be cut off the first course? A good place to start is approximately at the half unit range. This will result in field cutting the caps to finish the top of wall in the corner. If it is important to finish the wall with full cap units versus a cut unit as shown below, you will need to know how much setback occurs in your wall from base course to cap course to determine the starting location of the last full unit (uncut) at the base. To determine setback, follow this simple method: Place 3 units on a smooth level surface. Place fiberglass pins in desired setback option. Place next course of units in running bond pattern over base units. Pull upper unit forward towards face of wall. Now measure distance from tail surface of lower and upper courses. This is your setback dimension! Multiply this measurement times the total number of vertical courses. This will then give you the projected horizontal shift required to handle the setback of the two 90 walls away from the starting point. QUESTION: ANSWER: EXAMPLE: How do I determine the smallest concave radius I can construct before unacceptable gapping between units may occur? Multiply the height of wall by two. The result is the smallest radius dimension. Wall Height (4') (1.2m) x 2 = Smallest Radius (8') (2.4m) NOTE: This formula applies to installations using the 8.8 batter. For the 4.4 batter use a multiple of 1.5. For the near vertical batter, no radius limitations are expected. No minimum radius applies. The near vertical batter is recommended for walls with multiple curves. QUESTION: ANSWER: EXAMPLE: How do I determine the smallest convex radius I can construct before binding between units may occur? Multiply the height of wall by two. The result is the smallest radius dimension. Wall Height (4') (1.2m) x 2 = Smallest Radius (8') (2.4m) NOTE: This formula applies to installations using the 8.8 batter. For the 4.4 batter use a multiple of 1.5. For the near vertical batter, no radius limitations are expected. Minimum overall radius is 3.5' (1m). QUESTION: ANSWER: EXAMPLE: How do I determine how many Keystone units will be required for a given radius or for a complete circle? Multiply the diameter of the circle (the measurement of a line passing through the center from one side of the circle to the other or 2 x the radius) by 3.146. Divide the result by 1.5. The result is the number of units for a complete circle. Diameter (10') x 3.146 = 31.46 1.5 = 21 units for a 10' circle or 5 units for a 90-5' radius arc within a wall (3.05m x 3.146 = 9.6m x 2.19 units/m = 21 units) 11

DISTRIBUTED BY: The information contained herein has been compiled by Keystone Retaining Wall Systems, Inc. and to the best of our knowledge, accurately represents the Keystone product use in the applications which are illustrated. Final determination of the suitability for the use contemplated and its manner of use are the sole responsibility of the user. Structural design and analysis shall be performed by a qualified engineer. GAGNE & SON 28 Old Rt. 27 Rd. Belgrade, ME 04917 (800) 339-3313 fax (207) 495-3451 www. Keystone Retaining Wall Systems, Inc. A CONTECH Company 4444 West 78th Street Minneapolis, MN 55435 (952) 897-1040 www. HARDSCAPE PRODUCTS CONSTRUCTION SUPPLIES CONCRETE BLOCKS PRECAST PRODUCTS