Mycoplasma Testing Products & Services. M-175 CELLshipper Mycoplasma Detection Kit (In-house sample preparation and slide fixation)



Similar documents
Genomic DNA Extraction Kit INSTRUCTION MANUAL

FACULTY OF MEDICAL SCIENCE

About Our Products. Blood Products. Purified Infectious/Inactivated Agents. Native & Recombinant Viral Proteins. DNA Controls and Primers for PCR

MLX BCG Buccal Cell Genomic DNA Extraction Kit. Performance Characteristics

HOMEOPATHIC MEDICINAL PRODUCT WORKING GROUP (HMPWG) GUIDANCE ON MODULE 3 OF THE HOMEOPATHIC MEDICINAL PRODUCTS DOSSIER

TEST METHOD VERIFICATION AND VALIDATION

Fast, easy and effective transfection reagent for mammalian cells

The Facts on Equine Drug Testing

The Antimicrobial Susceptibility Testing Device Manufacturer: Development Process, Timelines, and Challenges

Development and Validation of In Vitro Diagnostic Tests. YC Lee, Ph.D. CEO

Principles of Microbiological Testing: Methodological Concepts, Classes and Considerations

Human CD4+T Cell Care Manual

50 g 650 L. *Average yields will vary depending upon a number of factors including type of phage, growth conditions used and developmental stage.

Risk-Based Environmental Monitoring. Marsha Stabler Hardiman Senior Consultant Concordia ValSource Wednesday September 17, 2014 FDA/PQRI

Human Peripheral Blood Mononuclear Cell (PBMC) Manual

Intended Use: The kit is designed to detect the 5 different mutations found in Asian population using seven different primers.

ABSTRACT. Promega Corporation, Updated September Campbell-Staton, S.

SCANTIBODIES Laboratory, Inc. Contract Monoclonal Antibody Production

Assay Qualification Template for Host Cell Protein ELISA

Especially developed for the transfection of mammalian cells with sirna or mirna

cgmp Challenges for Cord Blood Banks

IQCP GUIDELINES and TEMPLATE FOR GETTING STARTED

International GMP Requirements for Quality Control Laboratories and Recomendations for Implementation

Non-clinical development of biologics

Diane Kadidlo MT(ASCP) SBB University of Minnesota Joanna Stanson, M.S. University of Pittsburgh

Manufacturing Cellular Products for International Clinical Trials

Instructions. Torpedo sirna. Material. Important Guidelines. Specifications. Quality Control

Sutter Health Support Services Shared Laboratory Position Description. Incumbent: Laboratory Date: October 23, 2006 Written By: Michele Leonard

JOINT COMMISSION INTERNATIONAL ACCREDITATION STANDARDS FOR. 2nd Edition

European Medicines Agency

LABORATORY SUPERVISOR JOB CODE: 2701 DATE: 11/8/95

Validation Guide for the DNA IQ Reference Sample Kit for Maxwell 16 Printed in USA. 9/06 Part# GE181

Microbiological Best Laboratory Practices, USP <1117> Value and Recent Changes to a Guidance of Quality Laboratory Practices

FDA and the Compounding Pharmacy

CHAPTER 13. Quality Control/Quality Assurance

Transfection reagent for visualizing lipofection with DNA. For ordering information, MSDS, publications and application notes see

Cell Discovery 360: Explore more possibilities.

Preparing for the Pre-Approval Inspection What to do Before the FDA Arrives. Barry A. Friedman, Ph.D. Consultant

Medical Microbiology Culture Media :

TSI BIOTRAK REAL-TIME VIABLE PARTICLE COUNTER FACILITY MONITORING SYSTEMS

Prepublication Requirements

Human Umbilical Cord Blood CD34 + Progenitor Cell Care Manual

General Services Administration Federal Supply Service Authorized Federal Supply Schedule Price List

Biopharmaceutical Process Evaluated for Viral Clearance

Veterinary Testing. Classes of Test

4A. Types of Laboratory Tests Available and Specimens Required. Three main types of laboratory tests are used for diagnosing CHIK: virus

Luca Romagnoli, Ph.D. Business Development Manager

Raw Milk Quality Tests Do They Predict Fluid Milk Shelf-life or Is it time for new tests?

PCR and Sequencing Reaction Clean-Up Kit (Magnetic Bead System) 50 preps Product #60200

SERVICES FOR. Devices and Combination Products

IgM ELISA. For the quantitative determination of IgM in human serum and plasma. For Research Use Only. Not For Use In Diagnostic Procedures.

Guidance for Industry

Microbiology BIOL 275 DILUTIONS

Implementing New USP Chapters for Analytical Method Validation

AURAMINE O STAIN. Preanalytical Considerations

GMP Pharma BV. Netherlands

CHMP/BWP (COMMITTEE ABBREVIATION) GUIDELINE ON VIRUS SAFETY EVALUATION OF BIOTECHNOLOGICAL INVESTIGATIONAL MEDICINAL PRODUCTS

RUCDR Infinite Biologics Cell Culture and Stem Cell Center

Creating Standard Curves with Genomic DNA or Plasmid DNA Templates for Use in Quantitative PCR

Reconstituting and Diluting Primers and TaqMan Probes

Guidance for Industry Pyrogen and Endotoxins Testing: Questions and Answers

Blood, Plasma, and Cellular Blood Components INTRODUCTION

XV.Quality Assurance in the Blood Bank

ab Hi-Fi cdna Synthesis Kit

FastLine cell cdna Kit

CANADIAN RULE BASED CLASSIFICATION SYSTEM (IVDD) Life Sciences British Columbia NRC-Industry Research Assistance Program

TransIT Transfection Reagent

RECOMMENDATIONS FOR PRODUCTION AND CONTROL OF INFLUENZA VACCINE (INACTIVATED) Introduction General considerations

ENVIRONMENTAL TESTING & MONITORING: Deciphering Compliance Requirements for Pharmaceutical and Medical Device Manufacturers A WHITE PAPER

Description: Molecular Biology Services and DNA Sequencing

Best Practices for Maintaining Quality in Molecular Diagnostics Gyorgy Abel, MD, PhD

ASSURING THE QUALITY OF TEST RESULTS

ZR DNA Sequencing Clean-up Kit

Medical Laboratory Technology Program. Student Learning Outcomes & Course Descriptions with Learning Objectives

GENETICS CRIME SCENE DNA COLLECTION AND PRESERVATION FOR HUMAN IDENTIFICATION. Innovating Together. copanflock.com

FOOD FOR THOUGHT Topical Insights from our Subject Matter Experts UNDERSTANDING WHAT IS NEEDED TO PRODUCE QUALITY DATA

Algorithm for detecting Zika virus (ZIKV) 1

Guidance for Industry. Monoclonal Antibodies Used as Reagents in Drug Manufacturing

Contents. Abstract...i. Committee Membership... iii. Foreword... vii. 1 Scope...1

Department of Microbiology Vidyasagar University Midnapore West Bengal

Application Guide... 2

7- Doctoral Degree in Public Health and Public Health Sciences (Majoring Microbiology)

Biologic Air-Borne Particle Detection, Sampling, and Identification

Combination Products. Presented by: Karen S. Ginsbury For: IFF March PCI Pharma

PowerFecal DNA Isolation Kit

Transformation Protocol

ZR-96 DNA Sequencing Clean-up Kit Catalog Nos. D4052 & D4053

Molecular and Cell Biology Laboratory (BIOL-UA 223) Instructor: Ignatius Tan Phone: Office: 764 Brown

TransformAid Bacterial Transformation Kit

Streptococcus pneumoniae IgG AB (13 Serotypes), MAID... 7

RT-PCR: Two-Step Protocol

BaculoDirect Baculovirus Expression System Free your hands with the BaculoDirect Baculovirus Expression System

UltraClean Soil DNA Isolation Kit

MTT Cell Proliferation Assay

Metagenomics revisits the one pathogen/one disease postulates and translate the One Health concept into action

Transcription:

Cell Culture Testing M-1500 Real-Time PCR with Broth Enrichment A specific and sensitive method for the detection of mycoplasma using Real-Time PCR coupled with a pre-enrichment procedure to enhance method sensitivity. Each assay includes a comprehensive control panel to assure accurate results. Total Testing Time: 4-6 days Minimum Test Volume = 1.2 ml M-1500Q Real-Time PCR Matrix Qualification Any sample submitted for Real-Time PCR analysis should be qualified within the context of the assay to evaluate the effect of the sample matrix on the enrichment procedure and Real-Time PCR performance. This analysis would only need to be conducted once for any given sample unless there are changes in the test article components. Total Testing Time: 4-6 days Minimum Test Volume = 1.2 ml M-100 CELLshipper Mycoplasma Detection Kit Our exclusive CELLshipper DNA fluorochrome staining kit is a fast and convenient qualitative assay for the detection of mycoplasma contamination in cell cultures. Purchase the slides and store in your lab for use at your convenience. Simply add your cell culture sample, fix and dry. Return the (hazard-free) slides to our laboratory for diagnosis. Total Testing Time: Results within 48 hours of receipt. M-150 DNA Fluorochrome Staining Assay with Indicator Cell Line DNA fluorochrome staining assay with sample inoculation on an indicator cell line. This approach enhances the assay sensitivity by reducing background from genetically unstable cell lines (e.g. hybridomas, etc.) and amplifies the titer of mycoplasma contaminants. Developed for the detection of mycoplasma contamination in cell cultures and related samples, this test provides reliable and timely results. Total Testing Time: 3-5 days Minimum Test Volume = 1 ml M-175 CELLshipper Mycoplasma Detection Kit (In-house sample preparation and slide fixation) This test includes the use of our exclusive CELLshipper DNA fluorochrome staining kit. However, all the steps including the preliminary sample collection, slide preparation and fixation are performed by our expert Technical Staff. This test is designed to screen for mycoplasma contamination in a variety of cell culture samples (i.e. adherent and non-adherent cell lines.) Total Testing Time: 1-2 days Minimum Test Volume = 2 ml

Cell Culture Testing (Continued) M-250 Multi-Media Direct Culture Method with DNA Fluorochrome Staining Assay Multi-media direct culture procedure using three (3) mycoplasma media preparations combined with the indicator cell culture procedure. The DNA fluorochrome assay with indicator cell line enhances the detection of non-cultivable mycoplasma species. This is the optimum screening procedure for detecting mycoplasma contamination in cell cultures. Total testing time: 28 days Minimum Test Volume = 5 ml Culture Media & Sera Testing M-155 DNA Fluorochrome Staining Assay with Indicator Cell Line for Sera Products Mycoplasma screening of serum products by Total Testing Time: 3-5 days DNA fluorochrome staining assay with indicator cell line. The enrichment component of this method enhances Minimum test volume = 35 ml detection of non-cultivable mycoplasma species. M-300 Large Volume Barile Method Mycoplasma testing of sera, media and bioproducts by direct culture method described in the Large Volume Barile Method. Bionique enhances the test by utilizing three (3) mycoplasma media formulations to maximize detection of potentially fastidious cultivable mycoplasma species. Minimum test volume = 55 ml; 100 ml aliquot preferred GMP Service M-350 Large Volume Barile Method with DNA Fluorochrome Staining Assay This test consists of the Large Volume Barile Method (M-300 testing service) with the addition of the Indicator Cell Culture procedure and DNA fluorochrome staining assay (M-155 testing service). Advantages of this combined approach include detection of both the cultivable and non-cultivable mycoplasma species. Minimum test volume = 90 ml; 100 ml aliquot preferred

Lot Release Testing M-700 FDA Points to Consider Method (1993) Mycoplasma screening of biologicals and cell cultures used to produce biologicals by direct culture method and indicator cell culture procedure. This test is recommended for each lot of product harvest concentrate and the master cell banks,working cell stocks and cell substrates used for the manufacturing of biopharmaceutical products. Minimum Test Volume = 15 ml. GMP Service M-800 Mycoplasma Test for Human Vaccines and Biologicals Compliance with 21 CFR 610.30 Mycoplasma screening of vaccines and biologicals for human use in compliance with 21 CFR 610.30 Subpart D - Test for Mycoplasmas. Bionique enhances the regulatory required direct-culture based method by incorporating the DNA fluorochrome staining assay with indicator cell line to detect potentially non-cultivable mycoplasma species. Minimum Test Volume = 10 ml Test Article and 10 ml of Control Fluid M-1000 Mycoplasmastasis Validation Study Bionique offers Mycoplasmastasis studies to validate our M-700 or M-800 Assay for an individual test article. The qualification study is designed to determine the presence or absence of productspecific inhibition of mycoplasma growth within our assays. This test is recommended only once for any given final product unless changes within the test article matrix or manufacturing processes occur. M-1400 Harmonized USP <63> Mycoplasma Test Bionique offers mycoplasma testing in full accordance with USP <63> and harmonized with the U.S. FDA Points to Consider and European Pharmacopoeia methods. This test can detect both agar cultivable and non-cultivable mycoplasmas. The M-1400 USP <63> test may be applied for testing tissues and/or cell cultures used to produce test articles, digest broth, or any material in which mycoplasma contamination is suspected. Minimum Test Volume = 15 ml M-1450 Inhibition Testing for the Harmonized USP <63> Mycoplasma Test The M-1450 Test is designed to determine the presence or absence of product-specific inhibition of mycoplasma growth within Bionique s Harmonized USP <63> assay. USP <63> and EP 2.6.7 both require the testing for inhibitory substances in the test article. This qualification study is recommended only once for any given final product unless changes within the test article matrix or manufacturing processes occur.

\ Mycoplasma Clean Up and Elimination M-500 Antibiotic Sensitivity Testing This test determines the susceptibility of a mycoplasma isolate to a range of antibiotics. Resistance to antibiotics, whether inherent or acquired, is a well known characteristic of mycoplasma. Therefore, the antibiotic sensitivity profile developed in this assay provides information regarding potential therapeutic agents targeted for an individual mycoplasma species and strain. Sample must currently be on test by a direct culture method at Bionique. M-900 Mycoplasma Elimination Elimination of mycoplasmas from contaminated cell cultures. Cells are treated with an antibiotic cocktail specifically formulated for the isolated mycoplasma(s). Requires M-250 and M-500, preliminary testing. R&D Non-. Consultation with Technical Services required prior to sample submission. Other Products and Services M-100 CELLshipper Mycoplasma Detection Kit Our exclusive CELLshipper DNA fluorochrome staining kit Total Testing Time: Results within 48 hours of receipt. is a fast and convenient qualitative assay for the detection of mycoplasma contamination in cell cultures. Purchase the slides and store in your lab for use at your convenience. Simply add your cell culture sample, fix and dry. Return the (hazard-free) slides to our laboratory for diagnosis. _ M-600 Mycoplasma Control Slides Five (5) control slides are provided per order for in-house DNA fluorochrome staining. Each slide contains two negative and two positive mycoplasma controls, fixed and ready for staining. These Mycoplasma Quality Control slides are designed to verify the quality of reagents and staining methods used for the detection of mycoplasma contamination via DNA fluorochrome staining. For use as quality controls in your laboratory. _ Mycoplasma Antigen Preparations Custom service providing high quality, purified antigen for use as positive controls in bioassays.

Mycoplasma Reference Standards M-1200 Non-viable Mycoplasma Lysate Preparations Enumerated non-viable mycoplasma defined in GC/mL Avoids the introduction of viable microorganisms into the laboratory and facility Developed to optimize the mycoplasma DNA isolation process of PCR-based rapid microbial methods for mycoplasma detection May be used to evaluate all processes downstream of centrifugation Risk-free proficiency testing and personnel training on your isolation method and PCR assay M-1250 Genomic Mycoplasma DNA Preparations Quantitated mycoplasma DNA defined in GC/uL Avoids the introduction of viable microorganisms into the laboratory and facility Proof-of-Concept (POC) evaluations for your PCR assay Post-centrifugation spiking studies to evaluate analytical sensitivity and specificity Risk-free proficiency testing and personnel training on your PCR assay Validation and Consultancy Services Bionique Testing Laboratories also offers validation and consultancy services related to the evaluation and implementation of Rapid Microbiological Methods for the detection of mycoplasma. Our vast in-depth knowledge and experience with these technologies allows us to provide a wide range of services to include phase appropriate method development to validation studies for regulatory submission. Our expert personnel are able to customize the projects to ensure we are meeting the individual scientific needs and regulatory expectations of our clients. Contact Us: For further information or inquiries please contact us at info@bionique.com or call us directly at +1 518-891-2356. Bionique requests that you contact us 48 hours in advance of shipping your samples. Information can be forwarded either by contacting us directly by phone at (518) 891-2356, faxing your sample submission form to (518) 891-5753, or e-mailing your sample submission form to reporting@bionique.com. Please provide details on the number of samples shipped and the mycoplasma testing service requested by catalog #. This will assist us in meeting your needs for quality and timely service. Effective Date: May 2016