EasyStart R + Operating instructions. Comfort radio remote control with integrated timer for parking heaters and more.



Similar documents
Operating instructions TSE Wireless Software Home

AN500T, AN1000, AN1000T, AN1500, AN1500T AN2000, AN2000T

Operating Instructions Thermo Call TC3. General Information. Use. Dear Webasto customer,

User Manual THR840DUK Digital Thermostat

Air conditioning, electrical testing

MAKING MODERN LIVING POSSIBLE. living connect. Installation and User Guide. Danfoss Heating Solutions

Operating instructions TSE Wireless Software Business +

Troubleshooting and Repair Instructions. The troubleshooting and repair instructions are applicable to the following unit versions only

B/S/H/ Error codes and service programmes PH

GB/DAS User Instruction

Antenna Splitter ASA 1. Instruction manual

The Parts of the System

Weather Station TE 529EL USER MANUAL

Installation instructions. For the competent person. Installation instructions. VRT 350f. VRT 350f GB, IE

INTRIC E. D Vers. 02 SELF-LEARNING ROLLING-CODE EXTERNAL RECEIVER

REMOTE TERMOMETER TE 219 LED USER MANUAL

VIVA 4G LTE Mini Router. Quick Start Guide

evohome Wireless Radiator Zoning Kit Installation & User Guide

Quick Reference Guide

User Guide. Temperature and Humidity Datalogger. Model 42280

Aurora UPC ZS Zone Sensors User Guide

Rousseau 10. User Guide

MAKING MODERN LIVING POSSIBLE. living connect. Installation and User Guide. Danfoss heating

Table of Contents. Introduction. Radio Frequency Control. Initial setup Setting the time. Setting the temperature

SCORPION. micron security products

DR 70 Portable Digital DAB+ and FM Radio Receiver User Manual English Please read carefully before using this product

GeyserWise TSE. thermostat instruction manual. SANS 181 compliant

BlueSolar Pro Remote Panel For BlueSolar PWM-Pro charge controllers 12/24V 5, 10, 20, 30A Article number SCC

LUCCI AIRFUSION QUEST II CEILING FAN

O. Gas boiler. Gaz 6000 W WBN H-E-N/L-S2400. Operating instructions for the end customer (2014/07) en

DAB+ / FM Tuner Model: TU-201

Wireless Remote Controller YB1FA

User's Guide. Integrating Sound Level Datalogger. Model Introduction

General notes: To avoid problems, always use:

UniTec-868, UniTec-915 Nr , Nr

TABLE 1: Wiring Terminals. Connect to... 1C 1H 2C 2H 1H1C 2H1C 2H2C 3H2C

USER MANUAL OPERATION AND USE OF CAR WITH. Diego G3 / NEVO SEQUENTIAL GAS INJECTION SYSTEM

Windows XP Pro: Basics 1

GSM Alarm System User Manual

IN-OUT Thermometer with Cable Free Sensor and Clock

Operating Manual Color Changing Fountains

Owner s Guide Guide du propriétaire Guía para el usuario TH115-AF-GB-10. Programmable thermostat Thermostat programmable Termostato programable

Remote Engine Start System User s Information Manual

ODYSSEY. Security System Owner s Manual. Kit No. 08E51-SHJ E55-SHJ American Honda Motor Co., Inc. - All Rights Reserved.

Owner s Manual FULL PREPARATION PACKAGE MOBILE PHONE

BUSINESS. Elektronisches Türschloss. Installation and User Manual. Ingeniously safe. Ingeniously simple.

Drayton Digistat +2RF/+3RF

On-line Manual Video Capture Software

Sensi TM. Wi-Fi Programmable Thermostat MANUAL OPERATION. Version: March Emerson Electric Co. All rights reserved.

15 Digital Photo Frame Instructional Manual

RADIO CONTROLLED DIGITAL CLOCK MODELS / 88906

Mini Timer Owner's Manual. Model MT13A

New GSM Alarm System. User s Manual. Profile For a better understanding of this product, please read this user manual thoroughly before using it.

FMT600BT Transmitter

Mounting and operating instructions. Surface-mounted hands-free feature home station

Time Recorder. User Manual. PDF created with FinePrint pdffactory trial version

Water Tank Level Monitor

WIRELESS WEATHER STATION Model USER'S INSTRUCTIONS

in.k600 TechBook Giving full control to wet fingers! series of full-function keypads with streamlined interfaces

G-100/200 Operation & Installation

Nokia Wireless Keyboard (SU-8W) User Guide

Hotline

1. Overview. WPT Wireless Range Tester Kit User Manual Doc No Rev Components Prerequisites for Site Survey

ENGLISH. Installation video Operating video Settings video.

My home. Mobile phone application. Instructions for use and installation. For DELTA DORE GSM transmitters and transmitter control units.

GSM Remote control. Version W-BUS v9.x. Operating manual

OPERATING INSTRUCTIONS SECURITY SYSTEM KIT NO.: 08E51-EP American Honda Motor Co., Inc. - All Rights Reserved. 1

Operating instructions IV / 2007

Article: Version:

AIR CONDITIONER REMOTE CONTROLLER ILLUSTRATION CS457-R14A

Manual. PC-Software Save`n carry PP 50 pro

body fat scale + Instruction Manual complete body analysis scale HEALTH

CR Band Auto Set Dual Alarm Clock Radio ROBERTS. Sound for Generations. Please read this manual before use

Security System. User Guide for the LED Command Center

Operator Manual. Franking machine T 1000 Trend

BLU Vivo 4.3 User Manual

8 Digital Photo Frame Instructional Manual

HiPath HiPath 1120 HiPath 1130 HiPath 1150 HiPath Instruction Manual System Telephone Profiset 3030

Please refer to the chapters below for detailed information about all aspects of the products usage.

PUSH BUTTON START INSTALLATION MANUAL

1 Safety instructions. 2 Device components. Facility Pilot Server. Art. No. : FAPV-SERVER-REG Art. No. : FAPVSERVERREGGB. Operating instructions

Tiny Audio C3. English TINY AUDIO C3. Please read carefully before using this product

DVR GUIDE. Using your DVR/Multi-Room DVR WAVE-123 wavebroadband.com

Product Information Sheet UH36 Hi Pot Tester

Tebis application software

My home Mobile phone application

TC-9102 Series Surface Mount Temperature Controllers

Quick Reference Guide

Electronically Controlled Air Suspension (ECAS) for Trucks

Mold Alert... Operation Manual P0270

Android Dongle. User Manual TL869

AM/FM PLL Clock/Table Radio

Operating instructions Diffuse reflection sensor with background suppression O1D101 O1D / / 2012

Owner s Guide. ca6554

Backup Tab. User Guide

CM921 - User Guide. Description. Features. 1 day Wireless Programmable Room Thermostat with LoT technology WHAT IS A PROGRAMMABLE ROOM THERMOSTAT?

Product information and manual for SensLab BT-Adapter (Model type: BT060721) for wireless data transfer of measurement data of Lactate Scout-handheld

Point of view HDMI Smart TV dongle Mini RF Keyboard

OWNER S OPERATION GUIDE English

Transcription:

EasyStart R + Operating instructions. Comfort radio remote control with integrated timer for parking heaters and more. 22 1000 32 80 06 03.2009

Contents Introduction Please read first... 3 Purpose... 3 Safety information... 3 Statutory regulations... 3 General information... 4 Overview Mobile unit of the radio remote control... 5 Displays... 6 Operation and Adjustment Basic operation and adjustment rules... 7 Activate mobile unit... 8 Set weekday, time and operating time... 9 Switch on heater... 10 Switch off heater... 11 Switch on ventilation... 12 Switch off ventilation / General information on ventilate mode... 13 Switch on add-on unit... 14 Switch off add-on unit / General information on the add-on unit... 15 General information on programming the preset time... 16 Program preset times... 17 18 Delete preset times... 19 Heizstufe einstellen bei Wasserheizgeräten... 20 Heizstufe einstellen bei Wasserheizgeräten... 21 Maintenance Battery charge status... 22 Replace battery... 22 What to do if? Displays... 23 25 Service Hotline... 26 2

Introduction Please read first Before you start to set and use the radio remote control, please ensure you carefully read through these operating instructions. These operating instructions contain important information, which you require to set and use the radio remote control. Please store these operating instructions in a safe place so you can refer to it at a later date. Safety information Important! Danger! Only the battery cover of the mobile unit may be opened. The battery and battery cover must be kept out of reach of children swallowed small parts. Before washing clothing, remove the mobile unit from pocket. Protect the mobile unit from adverse effects (impacts, extreme temperatures, moisture, rain, liquids). The mobile unit and heater must be switched off when refuelling. Dispose of the battery and mobile part according to the statutory regulations. Improper use and use outside the specified area of use cancels all liability and warranty. Only use the recommended battery and original spare parts. All information and notes, in particular the safety information in the heater s technical description must be observed at all times! Statutory regulations Return / disposal of electrical and electronic equipment in accordance with Art 4 Paragraph 1 Alt Fz-VO (End-of-Life Vehicles Regulations) As a part of the vehicle, when the vehicle is handed into a recognised waste collection body, a recognised returns body or a recognised dismantling firm, the radio remote control must be placed in the vehicle for return in accordance with Art 4 Paragraph 1 Alt Fz-VO. Purpose The bidirectional radio remote control EasyStart R+ (mobile unit in conjunction with stationary unit) is used for remote controlled switching on / off and presetting the switching on time, operating time and mode of the heater and/or add-on unit installed in the vehicle. Please note! Improper use and use outside the specified area of use cancels all liability and warranty. 3

Introduction General information The mobile unit of the radio remote control has a simple control structure. With only 4 keys, it is possible to set all functions, change them if necessary and program the preset times. The switching pulses of the mobile unit have an outdoor range (direct visual contact) of up to 1000 metres. External interference, local conditions and dense building development in the surrounding area shorten the range. The mobile unit should always be pointed towards the vehicle when activated or for data transmission. Depending on use and ambient effects however, displays can appear which are described in the chapter What to do if? from page 23. If you and the mobile unit are outside the range you do not have to do without the heater. The preset mode is then available as an alternative. If a vehicle was disconnected from the power supply (battery disconnected) and the power supply is reinstated, the time appears when the mobile unit is activated. This must then be adjusted. See description on page 9 Set weekday, time and operating time. Operation of the mobile unit is described in detail from page 7. 4

Overview Mobile unit of the radio remote control The mobile unit of the radio remote control can be used to make the necessary adjustments for operation of the heater and various units can be switched on and off. Please note! The number of symbols and displays differs depending on the installed heater and feature options. Menu bar Display bar Program bar Display of the active program memory and corresponding weekday Status display Back control key Select a function in the menu bar and adjust values Activation key Mobile unit ON / OFF Switch over in the display bar between Temperature Time Operating time Temperature setpoint value Switch back to the menu bar Next control key Select a function in the menu bar and adjust values OK key Select the flashing symbol or confirm inputs Key fob 5

Overview Displays Menu bar Heater ON / OFF Ventilation ON / OFF Add-on unit ON / OFF Program preset time Set the time / operating time Set heating level Display bar Numerical and text displays AM Time in the morning (English) PM Time in the afternoon (English) C Temperature in degrees Celsius F Temperature in degrees Fahrenheit Unlimited operating time Heating level is set Program bar Preset memory 1 Preset memory 2 Preset memory 3 Mo So Weekdays Mo Su English weekdays Status display Heating mode active Ventilation mode active Add-on unit active Communication between mobile unit and stationary unit Battery charge status Please note! If the program number is underlined, e. g. this program will be executed next. Ventilate mode is not possible in all heater models. The add-on unit function is not possible with all heater models and must be activated by the installation workshop. 6

Basic operation and adjustment rules Activate mobile unit Before each operation or setting, a connection must be established between the mobile unit and the stationary unit. To do this, press until the menu bar appears in the display, then release the key and continue with the operation or adjustment (see also page 8). Switch off mobile unit / protect mobile unit against involuntary actuation If is pressed for a long time the display disappears, i.e. the mobile unit is switched off and is therefore also protected against involuntary actuation. Flashing symbols Each flashing symbol in the menu, program and display bar can be changed with or and confirmed with. Confirm input The settings and changes must always be confirmed with, otherwise they are lost (exception: operating time). Terminate/quit settings You can use to terminate or quit entering settings in a menu. Display disappears If a setting/adjustment or confirmation is not made within 10 seconds the display disappears, i.e. the mobile unit returns to its normal condition. For renewed input you must press again. Set operating time (one-off or permanent) The operating time can be individually set with or. In preset mode from 10 120 minutes. In immediate operation from 10 120 minutes or continuous operation. See pages 9, 10, 12 and 14 for a description. Display during data transmission During data transmission (display SENd) the LED display lighting switches off. After the data transmission has finished the LED lighting is switched back on. 7

Activate mobile unit Use the mobile unit to establish the connection with the stationary unit. press until the menu bar appears in the display. The release the key. The symbol and text appear briefly, then the temperature is displayed. Display The radio remote control is activated. Please note! If the key is not released after the menu bar appears the mobile unit switches itself off. During data transmission (display SENd) the display lighting switches off. After the data transmission has finished the display lighting is switched back on. Possible displays such as, and are described in the chapter What to do if? from page 23. The following actions are possible: Switch over from temperature display to time and back, press. Select functions in the menu bar with or, confirm selection with. The further procedure is described in the relevant section for the selected function. 8

Set weekday, time and operating time Activate mobile unit with (see page 8). Display Select symbol with or. Confirm selection with. Select weekday with or. Confirm selection with. Set hours with or. Confirm setting with. Set minutes with or. Confirm setting with. Permanently set operating time for immediate operation with or. Confirm setting with. The set, current time is displayed. The adjustment is completed. The following action is possible: Select functions in the menu bar with or, confirm selection with. The further procedure is described in the relevant section for the selected function. 9

Switch on heater Activate mobile unit with (see page 8). Select symbol with or. Confirm selection with. Display Heater is switched on. The following actions are possible for the operating time: The operating time can be accepted with. The operating time can be changed as a one-off with or and then confirmed with. Please note! The operating time last displayed is adopted without confirmation. press to display the temperature, the last saved operating time remains valid. The following actions are possible: Call up display. press, the current heating level is displayed (in air heaters only). press to display the time. 10 press to display the operating time. See above for adjustment. Select functions in the menu bar with or, confirm selection with. The further procedure is described in the relevant section for the selected function.

Switch off heater Activate mobile unit with (see page 8). Display Select symbol with or. Confirm selection with. Heater is switched off. The following actions are possible: Switch over from temperature display to time and back, press. Select functions in the menu bar with or, confirm selection with. The further procedure is described in the relevant section for the selected function. 11

Switch on ventilation only possible if the menu bar (See page 13 for general information). symbol is displayed in the Activate mobile unit with (see page 8). Display Select symbol with or. Confirm selection with. Ventilation is switched on. The following actions are possible for the operating time: The operating time can be accepted with. The operating time can be changed as a one-off with or and then confirmed with. Please note! The operating time last displayed is adopted without confirmation. press to display the temperature, the last saved operating time remains valid. The following actions are possible: Call up display. press to display the time. press to display the operating time. See above for adjustment. Select functions in the menu bar with or, confirm selection with. The further procedure is described in the relevant section for the selected function. 12

Switch off ventilation only possible if the menu bar (See page 13 for general information). symbol is displayed in the Activate mobile unit with (see page 8). Display Select symbol with or. Confirm selection with. Ventilation is switched off. The following actions are possible: Switch over from temperature display to time and back, press. Select functions in the menu bar with or, confirm selection with. The further procedure is described in the relevant section for the selected function. General information on the ventilate mode If the symbol is not displayed in the menu bar, ventilate mode is not possible for the heater models used. In ventilate mode of HYDRONIC water heaters the vehicle blower is directly controlled by by-passing heating mode and in AIRTRONIC air heaters the heater s blower is directly controlled by by-passing heating mode. Please note! Ventilate mode is not provided for upgraded independent heaters. If you have any further questions regarding ventilate mode please contact your installation workshop or call the service phone number (see page 26). 13

Switch on add-on unit only possible if the symbol is displayed in the menu bar (See page 15 for general information). Activate mobile unit with (see page 8). Display Select symbol with or. Confirm selection with. Add-on unit is switched on. The following actions are possible for the operating time: The operating time can be accepted with. The operating time can be changed as a one-off with or and then confirmed with. Please note! The operating time last displayed is adopted without confirmation. press to display the temperature, the last saved operating time remains valid. The following actions are possible: Call up display. press to display the time. 14 press to display the operating time. See above for adjustment. Select functions in the menu bar with or, confirm selection with. The further procedure is described in the relevant section for the selected function.

Switch off add-on unit only possible if the displayed in the menu bar. symbol is Activate mobile unit with (see page 8). Display Select symbol with or. Confirm selection with. Add-on unit is switched off. The following actions are possible: Switch over from temperature display to time and back, press. Select functions in the menu bar with or, confirm selection with. The further procedure is described in the relevant section for the selected function. General information on the add-on unit An add-on unit can be e. g. a second heater or parking air conditioning. It is also possible to combine a heater with a blower. The blower is used to circulate air within the inside of the vehicle. The heaters or blower can be operated simultaneously or independently of each other. The add-on unit function must be activated by the workshop. 15

General information on programming the preset time The mobile unit of the radio remote control can be used to program 3 preset times. The 3 preset times can either all be spread over one weekday or be spread between different weekdays. In water heaters and a temperature sensor connected to the stationary unit the heater start is automatically calculated depending on the measured ambient temperature and the selected heating level (ECO or HIGH). The operating time can be between 5 and 60 minutes before the programmed departure time, whereby operation is always stopped 5 minutes after the programmed departure time. Therefore the minimum possible operating time is 10 minutes and the max possible operating time is 65 minutes. The operating time set in the set time menu (page 8) is ineffective in this case. In all other configurations the start takes place according to the preset operating time. Please note! The preset times are always departure times, even if runtime calculation is deactivated. You cannot program more than 3 preset times. The maximum operating time of 65 minutes for automatic runtime calculation is a factory setting. If necessary, this can be reduced by the installation workshop to a minimum of 15 minutes. Identical preset times If several identical preset times are programmed for a specific weekday in programs 1, 2 or 3 the last entered preset time is valid. When the mobile unit of the radio remote control is activated the saved identical preset times are deleted. If identical preset times are programmed for different weekdays there is not conflict. Overlapping of preset times Example: You have set heat mode for your departure time on a weekday to 13 hrs. At the same time ventilate mode has been programmed for 12.45 hrs on the same day and with an operating time of 15 minutes. What happens? The radio remote control calculates the heater start for heat mode which, depending on the ambient temperature measured, can lie between 5 and 60 minutes before the programmed departure time. If the calculated heater start is after 12.45 hrs, the vehicle is ventilated between 12.30 hrs and 12.45 hrs and is then heated. If the calculated heater start is before 12.45 hrs, the vehicle is heated until 12.30 hrs, then the heater is stopped and the heater switches to ventilate mode. After the set operating time for ventilate mode has expired the heater switches off. 16

Program preset times Activate mobile unit with (see page 8). Display Select symbol with or. Confirm selection with. Select preset memory 1, 2 or 3 with or and confirm with. Select weekday Mo Su with or and confirm with. Set hours with or and confirm with. Set minutes with or and confirm with. Select the required function, or with or and confirm with. Continued on page 18 17

Program preset times When selecting (heater with deactivated runtime calculation), or the operating time is displayed and can be adopted with or with or adjusted and confirmed with. Display The adjustment is completed. Please note! The assigned preset memory locations appear in the display. The preset memory activated as next is underlined in the display and the corresponding weekday is also displayed. The same procedure is required to program preset times in the preset memory 2 and 3. The following actions are possible: Switch over from temperature display to time and back, press. Select functions in the menu bar with or, confirm selection with. The further procedure is described in the relevant section for the selected function. 18

Delete preset times To display the preset times, the steps are the same as for adjusting/setting the preset time, until the current function flashes in the status bar. or press until appears in the display. Confirm with. Display The preset time is deleted. The following actions are possible: Switch over from temperature display to time and back, press. Select functions in the menu bar with or, confirm selection with. The further procedure is described in the relevant section for the selected function. 19

Set heating level of water heaters In water heaters you can choose between the ECO heating level (normal heating) and HIGH (comfort heating). The selected heating level is required to calculate the heat operating time depending on the measured ambient temperature. Please note! The heating levels ECO and HIGH are only effective in conjunction with a programmed preset time. Activate mobile unit with (see page 8). Select symbol with or. Confirm selection with. Display Select ECO or HIGH heating level with or and confirm with. The selected heating level (e.g. HIGH) is set. 20

Set heating level of air heaters Air heaters can be individually set to a heating level of 8 to 36 in immediate and preset mode. Please note! Heating levels 8 to 36 only approximately correspond to a temperature reading and therefore may differ from the actual temperature in the vehicle. Activate mobile unit with (see page 8). Select symbol with or. Confirm selection with. Display Change the heating level with or and confirm with. The new heating level is set. Function pushbutton The following activities can be executed with the button installed in the vehicle: Start heater mode, heating duration 30 minutes (LED on) Switch off all active units (LED off) 21

Maintenance Charged status of the mobile unit s battery (display in mobile unit) Battery ok Battery adequate Battery weak (replace soon) Emergency mode, change battery immediately If the status display of the mobile unit indicates a weak battery, purchase a CR 2430 type round cell battery made by Varta, Sony or Renata, as recommended by JE-Eberspächer. Replace battery Use a 1 Euro coin to turn the bayonet fastening of the battery cover in the direction of the arrow. Remove the battery cover. Check the cover seal for damage. Remove dead battery. Insert new battery. The battery has been correctly inserted if the plus pole symbol and the type designation of the battery can be read. Put on the battery cover. The dripshaped marking must point to the web between the recesses. Use a coin to turn the bayonet fastening of the battery cover in a clockwise direction until the slit reaches the vertical position. Activate mobile unit (see page 8). 22

What to do if? Displays Description Poor communication between the mobile unit and stationary unit. Data is received. However, it is faulty. Possible causes Remedy Distance between mobile unit and vehicle at the edge of the range. Dense buildings between mobile unit and vehicle? Several Easy Start radio remote controls are operated simultaneously. Change position relative to vehicle e. g. hold the mobile unit higher or move it to the side. Reduce distance from vehicle. Reduce distance. If possible, reinstate visual contact with the vehicle. Reactivate mobile unit after a pause. Description Communication between the mobile unit and stationary unit is not possible. Possible causes Distance between mobile unit and vehicle too large. Several Easy Start radio remote controls are operated simultaneously. Mobile unit has not been taught. Remedy Reduce distance. Reactivate mobile unit after a pause. Teach mobile unit as described in the installation instruction. Please note! If the messages and are displayed, no control / operation possible. A running heater can only be switched off using the button in the vehicle. 23

What to do if? Displays Description A fault occurs in the heater during operation (e. g. fuel shortage or interruption in the diagnostics cable). Remedy See heater s installation instructions for troubleshooting advice. Description Stationary unit is in learn mode. Remedy Teach mobile unit as described in the installation instruction. Description The mobile unit s battery is very weak. Data transmission is not possible. Remedy Replace battery (see page 22). Description The Set timer display appears after the mobile unit is activated. Possible cause Remedy Stationary part has been disconnected from the vehicle s battery. All Set time (see page 9). programmed preset times have been deleted. 24

What to do if? Displays The mobile unit cannot be activated Possible causes LED display button flashing Description Remedy Battery dead. Replace battery (see page 22). No battery inserted. Insert battery (see page 22). Battery inserted wrong way around. Insert battery correctly (see page 22). Remedy Stationary unit is in learn mode. The display switches itself off after 30 seconds or the teach the mobile unit as described in the installation instruction. Please note! If you are unable to remedy the fault or error, please contact an authorised JE workshop or call the service phone number given on the next page. 25

Service Hotline If you have any technical questions, a problem with your radio remote control or the heater, dial the following service phone number: Telephone hotline 00 49 (0)800 / 12 34 300 Fax hotline 00 49 (0)1805 / 26 26 24 Outside of Germany, please contact the respective national Eberspächer service agent. 26

www.eberspaecher.com J. Eberspächer GmbH & Co. KG Eberspächerstraße 24 D-73730 Esslingen Telefon 0711 939-00 Telefax 0711 939-0643 info@eberspaecher.com We reserve the right to make changes Printed in Germany J. Eberspächer GmbH & Co. KG