Zenith Solar thermal 4.5m pump station Installation manual



Similar documents
Installation and Commissioning Manual Solar Stations FlowCon Max Evolution II

Art.S001-S002 SOLAR MODULE WITH DELIVERY AND RETURN CONNECTIONS

Ergo-Pro Single Line Solar Station Installation and Operating Instructions

HYBRID STOR COMBINATION STORAGE CYLINDERS TRIPLE COIL INSTALLATION MANUAL

Plumbing and Electrical Installation Guide

SOLARcomfort Solar Hot Water Systems Pump Group

SPARE PARTS EXPLODED VIEW GAS WALL BOILERS Model GENUS PREMIUM FS CUENOD. R EN - Edition 01-26/10/2009

Coolflo Safe Touch Shower Mixing Valve ST20015CP

Installation and User Instructions Unvented Electric Storage Water Heater Models: S10UNV, S15UNV.

VIESMANN. Datasheet Part numbers and prices: see pricelist VITOSOL 200-F. Flat-plate collector for the utilisation of solar energy

Installation Manual. Solar Pool Heating System. Read the complete manual before beginning the installation

Data Sheet VITOSOL 100. Flat collectors for the utilisation of solar energy. Vitosol 100. Part nos. and prices: see price list

Solar Hot Water Heaters

Cooling system components, removing and installing

AGA GAS MARK 2 BURNER (CONVERSION) FITTING INSTRUCTIONS

Solar Collector Series. Product List

Installation and maintenance instructions. Danfoss Vent

SPARE PARTS EXPLODED VIEW GAS WALL BOILERS Model. CELTIC RSc b CUENOD. R EN - Edition 02-21/04/2005

Safe Touch TMV3 Thermostatic Shower ST10010CP

Clearly Solar Installation and Servicing System Hydraulics including Solar Pump Station and Accessories

FLEXCON EXPANSION VESSELS. Flamco FLEXCON Flexcon. Expansion vessels FLEXCON FLEXCON M. Flamco FLEXCON V-B.

SHOWER WATER HEATER MODEL BS 35 / 45 / 60 BS 35 E / 45 E / 60 E OPERATION AND INSTALLATION INSTRUCTIONS

SunMaxx Solar Filling Station Operating Instructions

AMERICAN SOLAR WATER HEATING SYSTEM The Best Water Heating Solution Under The Sun

Max primary circuit temperature 90ºC Max primary circuit temp. 90ºC Max secondary circuit temperature 45ºC Max secondary circuit temp.

Mikrofill Ethos Condensing combination boiler

Select Radiators Installation Guide

Stainless Steel Single and Dual Circulation Kits

What you can expect from your Solar Hot Water System

ECOplus Solar Cylinder

TABLE 1. Rugged cast aluminum alloy casing,celcon waterways with nichrome parts White (unless stainless steel housing)

3. SEISCO PARTS & SERVICE REMOVAL AND REPAIR GUIDE

FILLING AND PURGING THE SYSTEM

RESOL DeltaSol A. Mounting Connection Operation Examples. Manual

A.Y. McDonald Mfg. Co. Troubleshooting Submersible and Jet Pumps

Installation and User Instructions Aquaheat Unvented Water Heaters Models: AH7/2.2, AH10/2.2, AH15/2.2

Modulex. Gas Fired Boiler Systems PIPING GUIDE GF-115-P. Modular, Condensing, Hot Water Boilers Models: 303, 454, 606, 757, 909, Instruction No.

Spare Parts List Activ A 25C Activ A 30C Activ A 35C Activ A 18S Activ A 25S Activ A 30S

Installation and Servicing Instructions. Alpha 240/280. Range of Wall Mounted, Fan Assisted, Room Sealed, Gas Fired Combination Boilers

Globo P. Ball valves Pump ball valve made of gunmetal

THE CLOSED SYSTEM. removed except for maintenance. The closed system is not connected to the potable domestic water source.

OWNER S MANUAL FORCE 10 MARINE COMPANY HAMILTON ROAD RICHMOND, BC CANADA V6V 1C9 TEL: (604) FAX: (604)

Constantemp Double Wall Low pressure steam-water Heater F-340LDW,F-640LDW, F-940LDW and F-1240LDW

THE BOILING WATER DISPENSER INSTALLATION & OPERATING INSTRUCTIONS

maximise the sun s energy with warmflow solar Warmflow Solar

INSTALLATION AND OPERATION INSTRUCTIONS - (LOW FLOW MODELS) (Before installation, compare electrical needed for the model of heater selected)

STATIONARY WATER HEATERS

Isotemp Basic, Slim/B & Slim Square

ELECTRIC CENTRAL HEATING FLOW BOILER

Installation and Operation Instructions Domestic hot water modules: FriwaMidi DN 20 FriwaMaxi DN 25

Heating, Ventilation, Air Conditioning and Refrigeration (HVACR)

Technical data. Danfoss DHP-A

SOLAR HEATING SYSTEMS.

1 DESCRIPTION OF THE APPLIANCE

Model: 400E-2M. Bermad Electrically Controlled Deluge Valve with Easy Lock Manual Reset. Installation Operation Maintenance. Application Engineering

COMMISSIONING OF HVAC SYSTEMS

building engineering services association specification for: Domestic Heating

Installation and Servicing Instructions. Eco. Wall Mounted, Fan Assisted, Room Sealed, Gas Fired, High Efficiency Condensing Combination Boiler

Shower Handbook (Also covers 650 chrome variant)

Hydraulic control unit series

Installation Manual Gravity Solar Water Heater Evacuated Tube Integrated (Direct) System, unpressurized

stainless steel pre-assembled manifolds

BUILT-IN DISHWASHER INSTALLATION INSTRUCTIONS

Spare Parts List M96A.24SM/B M96A.28SM/B

Solar Skies Stainless Tank Series Water Heater

BERMAD Fire Protection

Volkswagen Jetta, Golf, GTI 1999, Liter VR6 2V Engine Mechanical, Engine Code(s): AFP 17 Engine-Lubrication (Page GR-17)

Hydraulic Power Brake (HPB) Catalog

User manual. 086U6297 Rev. 9 EN

Cooling system components, removing and installing

ENGINE COOLING SYSTEM

Installation and maintenance instructions

AquaNova. Water heater. Installation & Servicing Instructions THESE INSTRUCTIONS TO BE RETAINED BY USER

Float and Thermostatic Traps Series H, C and X

Troubleshoot resources for homeowner

OHIO MEDICAL CORPORATION. Medical Gas Panel. Installation and Maintenance Manual

RVR Hybrid System Installer Instructions RVR Hybrid System Controller Installation Instructions

Elson Coral E. Open Vented Thermal Store providing mains pressure hot water heated by electricity. Installation, Servicing and User's Instructions

AIR AND DIRT SEPARATORS. Flamco FLEXVENT. Air and dirt separators FLAMCOVENT FLAMCOVENT CLEAN FLEXAIR FLAMCO CLEAN FLAMCO A-S.

INSTALLATION INSTRUCTIONS Fan Coil Replacement Coil Kit EBX & EBXX

Drain Back systems Made in Germany

Spare Parts List Activ A 12OV Activ A 15OV Activ A 20OV Activ A 25OV

Thermo Siphon Solar Systems

Artisan Thermostatic Bath Shower Mixer

RADIATOR VALVES / MANIFOLD ASSEMBLIES AND DIVERTERS

Domestic heat pumps. DHP-A Opti DHP-C Opti DHP-C Opti W/W DHP-H DHP-H Opti DHP-H Opti Pro/Opti Pro + DHP-L DHP-L Opti DHP-L Opti Pro/Opti Pro +

PRESSURE REDUCING CONTROL VALVE

BILL OF QUANTITY FOR THE HVAC WORKS OF The Institute of space technology, near Toll Plaza (G.T. Road,) Islamabad

Alpha CD13R,18R and 24R

VOYAGER 570G. 744A Sprayer Control

WHAT YOU DON T KNOW ABOUT ACCUMULATORS CAN KILL YOU!

Replacement parts. WM97+ gas-fired water boiler Boiler Manual. OBTAIN PARTS ONLY THROUGH WEIL-McLAIN THE BOILER CONTAINS CERAMIC FIBER MATERIALS

SERVICE SERVICE COMPACT MANUAL. Mod X Mod X Mod X. Part 2

1. RANGE OF APPLICATION 3. SAFETY INSTRUCTIONS 4 4. DESIGN 4

Installation & Operation Manual Models: STU

Mounting and operating instructions. Fresh water station WHI freshaqua 44 #1 Fresh water station WHI freshaqua 55 # /

ecomax Instructions for use Wall hung room sealed fan assisted condensing boilers For the user

HIGH PRESSURE TECHNOLOGY HYDRAULICS PNEUMATICS TESTING EQUIPMENT

Owner & Installation Manual

Calibrating Differential Pressure Sensors

Transcription:

Zenith Solar thermal 4.5m pump station Installation manual Product code: 20026145 INSTALLATION MANUAL

WATER RETURN GROUP This instruction manual is an integral part of the installation and maintenance manual for the complete solar water heating system. Refer to that manual for GENERAL SAFETY INFORMATION AND PRECAUTIONS. DESCRIPTION The WATER RETURN GROUP N 4,5m cod. 20026145 allows you to connect a solar storage cylinder to a series of solar collectors. The water return group allows you to perform the operations of flow adjustment, flushing, filling and draining the circuit. The compact safety valve group contains a pressure gauge in addition to the safety valve itself. Versions with a solar regulator are also equipped with an electronic control unit for controlling the associated solar heating system. PACKAGING CONTENTS Description Qty. 1 - Return group 1 2 - Valve group fixing screws, washers and expansion plugs 2 3 - Solar regulator (if included) 1 4 - Solar controller bracket (accessory) 1 5 - Outlet pipe (accessory) 1 6 - Fixing nut assembly 1 7 - Probes (if included) 3 8 - Instruction leaflet 1 3 1 4 2 6 7 5 8 10

INSTALLATION Positioning the water return group b If If you are installing the valve group on the storage cylinder, fit the outlet and return pipes (5) (accessories) with the fixing nut assembly (6) mounted on the return pipe. 6 b Before fixing the valve group in place, identify its correct position with respect to the solar coil outlet and return unions, and mark the points (A) to drill for the expansion plugs. 5 ENGLISH b Drill the outside of the storage cylinder at the points marked (A) and insert the expansion plugs for the valve group in order to avoid damage. A A - Position the water return group on the storage cylinder and fix it in place with the screws (2). b If you are fixing the water return group on a wall, make sure that you use the right type of wall plugs. 2 - If the installation includes a solar controller, fit the bracket (4) between the valve group and the storage cylinder first, then mount the solar controller on the bracket. 2 4 11

- Connect the safety valve drain to a pipe (T) to avoid burns from expelled fluid and to permit the heat transfer fluid to be recovered. - Connect up the expansion vessel (E), which is designed for use in solar water heating systems. T - Connect the pump and the sensors to the solar regulator (if provided) as instructed in the manual supplied with the regulator. SAFETY DRAIN E 12

DESIGN Return temperature gauge RETURN TO COLLECTOR Valve R Safety valve (6 bar) SAFETY DRAIN TO EXPANSION VESSEL ENGLISH Cock B Pressure gauge Insulation Solar regulator (if included) Pump Flow regulator V Cock A Flow meter G (l/min) RETURN FROM STORAGE CYLINDER 13

PREPARING FOR FIRST START-UP FLUSHING THE SYSTEM - Turn the knob of the valve (R) fully anti-clockwise. - Close the flow regulator (V) (so that the screw slot is horizontal). - Open the cocks (A) and (B) on the return group. - Pump water in through the cock (A) and wait for it to come out of the cock (B). Leave water flow through the system until it has been thoroughly flushed out. - Close the cocks (A) and (B) and re-open the flow regulator (V) (so that the screw slot is vertical). Return group R B b If copper piping has been used and joints have been hot brazed, flush out the system to remove any brazing residues. Seal test the system after you have flushed it out. A V Pump b Fill the solar collector with water/glycol mix immediately after flushing it out, because flushing water may remain trapped in the circuit (with a consequent risk of freezing). PREMIXING WATER + GLYCOL Glycol anti-freeze is supplied separately and must be premixed with water in a suitable container before being used to fill the system. For example, a mix of 40% glycol and 60% water provides anti-freeze protection down to a temperature of -21 C. Anti-freeze 50% 40% 30% Temperature -32 C -21 C -13 C Density 1,045 kg/dm 3 1,037 kg/dm 3 1,029 kg/dm 3 CLOSED position OPEN position Flow regulator V Graduated scale in l/min. b The propylene glycol supplied is specially formulated for solar collector applications and remains fully efficient throughout the -32 to +180 C temperature range. It is also non-toxic, biodegradable and biocompatible. b Do NOT part fill the circuit with pure glycol then add water later. b Do not use automatic or manual filling systems. b If the water supply is highly chlorinated, use distilled water to prepare the glycol/water mix. 14

STARTING FOR THE FIRST TIME FILLING THE CIRCUIT Step 1 Turn the knob of the valve (R) fully anti-clockwise. Close the flow regulator (V) (so that the screw slot is horizontal). Step 2 Open the manual bleed valve at the highest point in the system (if included) and keep it open throughout the filling operation. Step 3 Pump the heat transfer fluid around the circuit with an external filling pump until all air bubbles have been eliminated. Close the manual bleed valve at the highest point in the system (if included). Position of the knob of the return valve R 0 Flow stopped R 90 Upward flow only (non-return valve function) ENGLISH Step 4 Temporarily raise the pressure in the system to 4 bar. B Step 5 Start up the system for about 20 minutes. Step 6 Repeat the air bleed operation from step 3 on until all residual air is eliminated from the circuit. Pump Heat transfer fluid filling pump A V Step 7 Set the pressure in the system to 3 bar. Step 8 Close the cocks (A) and (B) and re-open the flow regulator (V). Flow regulator V Anti-freeze mix b Do not fill the system in bright, sunny conditions or if the collectors are hot. CLOSED position OPEN position Graduated scale in l/min. b Make quite sure that you have eliminated all air bubbles from the system. 15

ADJUSTING THE FLOW Correct flow adjustment is essential to proper functioning of the entire system. To achieve the best possible flow and reduce wastage, you need to find the right balance between the speed of the filling pump (C) and the adjustment made on the flow regulator (V). Proceed as follows: - Fully open the flow regulator (V) and adjust the pump (C) to minimum speed (I) - Read the flow rate from flow meter (G) and compare it with the flow rate specified for the system (see the table below for systems incorporating solar collectors). Return group N of collectors 2 3 4 Portata richiesta in l/min. 2 3 3 4 5 6 C - If the required flow rate is below that currently measured in the circuit, close the flow regulator (V) gradually (turning it clockwise) until the correct value is achieved. - If the required flow rate is above that currently measured in the circuit, increase the speed of the pump (C), then read off the new measured flow rate and repeat the previous step. V G Graduated scale in l/min. VALVE GROUP residual head 500 450 400 RESIDUAL HEAD (mbar) 350 300 250 200 150 100 50 0 0 200 400 I III II 600 800 1000 1200 FLOW RATE (l/h) 16

REPLACING THE PUMP Before starting work to replace the pump (C): - Switch the electricity supply to the storage cylinder s valve group and to any associated boiler OFF at the main switch and at the control panel. ON OFF - Close the flow regulator (V). Return group R - Turn the return valve knob 90 clockwise to close the return valve (R). ENGLISH - Unscrew the ring nuts H1 and H2 and remove the pump (C). H1 C Reverse the above steps to fit the new pump. H2 V CHECKS On completion of the installation, perform the checks listed in the table below. DESCRIPTION OK Water circuit No automatic or manual filling pumps Safety valve calibrated to 6 bar, and no shut-off valves between it and the collectors Drain line from safety valve follows suitable path Expansion vessel correctly located and pre-charged to 2.5 bar Water return group installed in return line Solar circuit delivery line connected to the top of the solar storage cylinder coil Non-return valve activated as gravity brake 17