Best Available Technology for Sodium Hypochlorite Storage Tanks



Similar documents
Derakane epoxy vinyl ester resins: The Evolution of Corrosion Resistant FRP

USE OF FIBER REINFORCED POLYMER LININGS FOR CONTROLLING CORROSION IN MINERAL AND CHEMICAL PROCESSING INDUSTRIES

SOLVING SECONDARY CONTAINMENT PROBLEMS

ENGINEERING SPECIFICATION PULTRUDED DYNAFORM FIBERGLASS STRUCTURAL SHAPES. July 1, 2008 Revision 2

FRP Construction with DERAKANE* Epoxy Vinylester Resins ; Codes and Standards

ENGINEERING SPECIFICATION PULTRUDED DYNARAIL FIBERGLASS LADDER & LADDER CAGES

Piping Systems. From design to your turnkey partner

THERMOSET EPOXY POLYMER CONCRETE FOR THE FABRICATION OF CHEMICAL CONTAINMENT VESSELS.

Scotch-Weld TM. Acrylic Adhesives. DP8405NS Green. Product Data Sheet. Date: March 2014 Supersedes: August 2013

STAYFLEX CORROSION CONTROL AND THERMAL INSULATION SYSTEM

Epoxy Curing Agents and Modifiers

Mainline Pipe Rehabilitation Using Cured-in-Place Pipe (CIPP) & Folded Pipe Technology

FRP AQUATIC DUCTWORK COMPONENTS LEADERS IN FIBERGLASS REINFORCED PLASTIC DUCT PRODUCTS

Sodium Hypochlorite General Information Handbook

Property Test/Standard Description. semi gloss (35-70) Flash point ISO 3679 Method 1 34 C IED (2010/75/EU) (calculated)

ENVIRONMENTAL EFFECTS ON COATINGS

Technical Data Sheet February 2014

Guide Specification STAYFLEX CORROSION CONTROL AND THERMAL INSULATION SYSTEM

Radiation Curable Components and Their use in Hard, Scratch Resistant Coating Applications

San Antonio Water System Standard Specifications for Construction ITEM NO SLIP-LINING SANITARY SEWERS

Many of our fiberglass models have optional lay-ups to suit their alternate intended usage.

High Performance Coating Systems THIOKOL. P r i m a r y a n d S e c o n d a r y C o n t a i n m e n t

Good Boards = Results

FRP Inspection Guide. An Inspection Guide for Fiber Reinforced Plastic (FRP) Equipment

3M Thermal Bonding Film AF42

Scotch-Weld TM. Epoxy Adhesive 1838 B/A Green 1838 B/A Tan 1838-L B/A Translucent. Technical Data February, Product Description

ENGINEERING SPECIFICATION FIBERGRATE MOLDED GRATING. January 24,

Epoxy Curing Agents and Modifiers

SPECIFICATIONS FOR SEWER PIPE AND LINING INSERTION - TRENCHLESS; GENERAL GUIDELINES (As Provided by NASSCO)

More inside :: Tackle even the toughest water treatment piping challenges with

Green Thread Product Data

3 Destructible Vinyl Label Material 7613T / 7930T

DETERMINATION OF TIME-TEMPERATURE SHIFT FACTOR FOR LONG-TERM LIFE PREDICTION OF POLYMER COMPOSITES

Adhesive Bonding of Natural Stone

Industrial Pipeline Integrity Management & Remote Polyurea Pipe Lining Systems.

Waterproofing System for Wastewater Tanks in Petrochemical Industries and Refineries

Cable ladder installation at S.C.M. Chemicals Limited s titanium dioxide Plant in Western Australia

ACRYLICS. The properties of the resulting acrylics vary depending on the nature of the alkyl groups both on the alcohol and the acrylic acid.

Sodium Hypochlorite. General Information Handbook. Updated April 8, Powell. Fabrication & Manufacturing Inc

Construction. 3-part thixotropic epoxy patching mortar. Product Description. Tests

Handling Corrosive or Abrasive Liquids

SECTION XXXXXX TECHNICAL SPECIFICATIONS FOR INSTALLATION OF PROTECTIVE COATINGS FOR MANHOLES, WETWELLS, AND OTHER SANITARY SEWER STRUCTURES

Fabcograte FRP Grating. Tolerances: ±1/16. Tolerances: ±1/16. THICKNESS BAR SPACING PANEL SIZE (FT.) WT (LBS) 1" 1.5" x 1.

REHABILITATION OF UNDERGROUND SEWER LATERAL PIPES WITH CURED-IN-PLACE-PIPE LINER SECTION 02542

Building Owners Guide to a Duro-Last System!

Blister Repair with Binding Resin for Spas, Marine and Gel Coat Structures

Rudder Repair and refinish

Guide on the Segregation, Packaging, Labelling and Storage of Laboratory Chemical Wastes for Schools

Chemical-Resistant Epoxies for Secondary Containment by Christine Stanley Ameron Inc., Protective Coatings Group

ASTM D 1599 Standard Test Method for Resistance to Short-Time Hydraulic Pressure of Plastic Pipe, Tubing, and Fittings

ACO Construction & Building Products

Crevice Corrosion on Stainless Steel Propeller Shafts

3M Ionic Liquid Antistat FC-4400

Oxidizer(s) Management and Use Guidelines

Chemical Handling : Bulk Liquid Chemical Unloading. Northern Michigan Wastewater Operators Seminar September 23, 2008

b. Alkalinity make your life easier and get the alkalinity between 80 and 120 PPM. c. ph from 7.2 and 7.8 so that the other chemicals work properly

CIPP for Large Diameter Pressure Pipes. Water Research Foundation Large Diameter Pipe Rehabilitation Seminar 20 January 2016 George Bontus, P.Eng.

family of products is really Reichhold s answer to the growing need to meet more stringent regulations and performance requirements.

Cutting Tool Materials

Right Angle Grinder USA MADE FLAP DISCS

The Cost-Effective Solution for Tough Applications

Anodes and Misc Equipment

WATER CHEMISTRY AND POOL WATER BALANCE

MaxCell Technical Manual Design Parameters

Label Material 7871 Thermal Transfer Polyester Label Material

Series 4000 Fiberglass Pipe and Fittings

Profiles for floors of same height Cerfix Projoint

Corrosivity of Water Supplies

3 Scotch-Weld TM. Epoxy Adhesive DP110 Translucent and Gray. Technical Data December, 2009

Quality Products for Secondary Containment. Application Areas: Superior Service

Rehabilitation Alternatives. MWEA Collection System Seminar October 1, 2009

Plastics and Polymer Business. Properties enhancement for Plastics

PERSONAL PROTECTIVE EQUIPMENT (PPE)

PARALOID KM-1 Acrylic Impact Modifier

DURABILITY OF MORTAR LININGS IN DUCTILE IRON PIPES Durability of mortar linings

SCOUT EPOXY-INFUSES NEW 42-FOOT SPORT FISHING BOAT

The Corrosion Chronicle

Scepter PVC Molded Junction Boxes

Sodium Hypochlorite. General Information for the Consumer. Revised 7/20/07. Odyssey Manufacturing Co.

REPORT OF A COATING FAILURE ON A 16-INCH OIL PIPELINE UNDER WET CO2 SERVICE

Rubber Lining. Your guide to productive rubber lining solutions

Naue GmbH&Co.KG. Quality Control and. Quality Assurance. Manual. For Geomembranes

CORROSION ENGINEERING RESIN-BASED POLYMER CONCRETES AND GROUTS

1.1.2 Polypropylene The polypropylene must be a white opaque film, 1 2 mil thick. Biaxial orientation is preferred.

Introduction of New Large Tow Carbon Fiber Products and PCM* Technology. * Prepreg Compression Molding

Steel Panel Frame. Exterior Steel Sheeting. Optional Rigid Insulation. Optional Steel Insulation Liner

EVALUATION ACCORDING TO ASTM F

Removable Insulation Blankets from A to Z

How to Avoid Conductive Anodic Filaments (CAF)

The Myth of Vapor Permeation and Thermal Insulation

FIBERGLASS REINFORCED PLASTIC (FRP) PIPING SYSTEMS DESIGNING PROCESS / FACILITIES PIPING SYSTEMS WITH FRP

Remediation of Mold Contaminated Ductwork

Introduction to Pressure Pipe Rehabilitation with CIPP

8 Chemicals from water treatment and distribution

A Guide to Trouble-Free Cooling Towers

How to use the Selection Guide

Fiberglass Rebar (GFRP Rebar)

THERMAL CONDUCTIVITY AND THERMAL EXPANSION COEFFICIENT OF GFRP COMPOSITE LAMINATES WITH FILLERS

Transcription:

Best Available Technology for Sodium Hypochlorite Storage Tanks Michael G. Stevens, Senior Staff Scientist, Ashland Inc. Paul Cohen, Diamond Fiberglass ABSTRACT Sodium hypochlorite disinfection has become the most common chemical treatment for waste water in North America. With the ever-heightening scrutiny around transportation of chlorine, manufacturers are choosing to transport concentrated bleach instead. Waste water treatment facilities and sodium hypochlorite manufacturers have a variety of construction materials from which to choose when designing storage tanks for this corrosive chemical liquid. Stainless steel is reasonable durable but far from the most economical choice. Fiber reinforced thermoset polymers (FRP) have become the industry standard for hypo storage tanks as it is quite economical and gives remarkably long service life. When the best resin and cure system are selected and the fabrication design is optimized, FRP tanks will often last for decades. This paper will demonstrate best available technology for FRP tanks in sodium hypochlorite service based upon laboratory testing and extensive field service in multiple locations. Key Words: Sodium hypochlorite, FRP Storage tanks Epoxy vinyl ester resins INTRODUCTION The municipal waste water treatment facilities have switched to sodium hypochlorite as the material of choice to treat the water. Elemental chlorine is no longer used because of environmental reasons. Sodium hypochlorite is an oxidizing material that is stabilized with sodium hydroxide. This makes it very corrosive toward many materials of construction. The stability of the sodium hypochlorite can also have an affect how corrosive the solution will be. The stability of sodium hypochlorite can be affected by several factors including concentration, ph, temperature and impurities such as metals present. The standard solution used in industry now ranges from 9 15% available chlorine. If the sodium hypochlorite is made using hard water, it will not be as stable because of metal contaminants such as iron, calcium and other metals which will make it more aggressive toward the material of construction of the storage tanks. Many materials of construction have been used to store sodium hypochlorite. These include linear high density polyethylene, cross linked polyethylene, fiber reinforced polymers (FRP) and titanium. The best material is titanium, but it is very expensive. Linear high density polyethylene and cross linked polyethylene will give a service of 7-11 years according to Odyssey Manufacturing Co. 1 The most common material of construction for bulk sodium hypochlorite storage is FRP using a premium epoxy vinyl ester resin. If the proper resin is used, FRP tanks can provide a long lifetime with minimum maintenance required. The type of resin used to construct the FRP tank will determine how long the tank can be used. Case histories show that these tanks can last longer than 20 years if made properly. A well-specified and properly constructed FRP tank can last 20-30 years or more with corrosion barrier inspections typically every two years with minor repairs as required. An improper design and

construction will result in corrosion barrier failure and structural damage in 3-5 years requiring complete replacement of the tank. The study conducted in this paper was to identify the best resin system and corrosion barrier construction to obtain the maximum service life for sodium hypochlorite storage tanks. The testing involved both laboratory testing as well as testing in the field. EXPERIMENTAL PROCEDURE Laboratory testing was carried out using ASTM C-581 2 Standard Practice for Determining Chemical Resistance of Thermoset Resins Used in Glass-Fiber Reinforced Structures Intended for Liquid Service. Glass reinforced panels were made in the laboratory with each resin that was tested. The test panels were made by wetting out the veil, then wetting out 3 layers of 450 g/m 2 chopped strand glass mat and finishing with another layer of veil. The resin was cured at room temperature overnight and then post cured for 8 hours at 94 C. The panels were then cut to the desired size and the edges coated with the same resin to seal all cut edges to prevent wicking. The sample coupons were placed in resin kettles at 50 C and at 65 C that contained 10-15% sodium hypochlorite solution. The sodium hypochlorite solution was changed out once a week to keep the available chlorine concentration above 9% at all times during the test. Samples were pulled out and evaluated at 1, 3, 6, and 12 months. The evaluation consisted of Barcol hardness retention, flexural strength retention, flexural modulus retention, and visual inspection of the coupons. Coupons were also placed in two sodium hypochlorite storage tanks that were located in Thornton, CO and Westminster, CO. These coupons were taken out of the tank and sent in for evaluation at 3, 6 and 12 months. The laboratory testing and the testing in the two storage tanks in Colorado was done on DERAKANE 1 411-350 epoxy vinyl ester resin (EVER1), HETRON 922 epoxy vinyl ester resin (EVER2), HETRON FR992 brominated epoxy vinyl ester resin (BREVER1), DERAKANE 510A-40 brominated epoxy vinyl ester resin (BREVER2), and DERAKANE Momentum 470-300 novolac epoxy vinyl ester resin (NEVER). The BREVER1 resin was tested with 2 layers of synthetic polyester veil and with 1 layer of synthetic polyester veil and with 1 layer of C-glass veil. The cure systems evaluated included a cobalt naphthenate (CoNap) /Methyl ethyl ketone peroxide (MEKP) cure system and a Benzoyl peroxide (BPO)/Dimethyl aniline (DMA) cure system. The other resins were only tested with 1 layer of C-glass veil and cured with BPO/DMA. All of the test coupons were post cured for 8 hours at 94 C. RESULTS Test results were obtained from laboratory testing in stabilized sodium hypochlorite at 50 C and are shown in Table 1. None of the test coupons showed significant reduction in flexural properties after 12 months. The visual inspections of the test coupons did show some differences in the surface attack on the coupons. The system that showed the most attack was the NEVER resin that was cured with BPO/DMA cure system. The surface of the resin had a flat finish indicating resin attack and only 40% of the edge coating remained. These two observations indicate resin attack is occurring and this resin would not be the best resin for long service life. The BREVER1 resin that was made with 2 layers of 1 Registered Trademark of Ashland Inc.

synthetic polyester veil and cured with CoNap/MEKP curing system 0.15 parts of CoNap used to cure the resin also showed significant surface attack. This still had some gloss in places but after looking at the surface with a microscope one could see surface attack down to the polyester veil bundles. This also showed open channels where the polyester fibers in the veil used to be. This indicates that the synthetic polyester fibers are being attacked by the sodium hypochlorite. The coupons made out of BREVER1 resin with 1 layer synthetic polyester veil but was cured using BPO/DMA showed an improvement in surface appearance over the coupon that was cured with CoNap/MEKP cure system. This is probably because the cobalt metal can promote the decomposition of sodium hypochlorite at the surface of the laminate resulting in hypochlorous acid generation. This is more aggressive to the resins and will cause a faster attack on the corrosion barrier of the laminate. Some indication of attack on the polyester veil was also observed. BREVER1 resin and BREVER2 resin with 1 layer of C-glass veil and cured with BPO/DMA cure system both still had a semi gloss finish on its surface. This showed no attack on the resin after 12 months. The EVER1 and EVER2 resins, which had 1 layer of C-glass veil and cured with BPO/DMA each, had a flatter finish on the surface after 12 months. They showed less attack than was seen with the cobalt cured resin system but slightly more than the BREVER1 and BREVER2 resin systems. In contrast the NEVER resin system in the test gave the lowest surface hardness and also had only about 40% of its edge coating remaining after 12 months. The surface also lost its gloss and has a flat finish - all signs of resin attack on the resin surface. These same coupons were placed in a sodium hypochlorite storage tank in Thornton, CO (Table 2) and in the City of Westminster, CO (Table 3) to see how the lab testing compared to real world testing. There was no difference in mechanical properties after 12 months. The visual examination of the coupons showed that only the NEVER resin coupon lost any surface gloss and showed signs of light resin attack. No differences could be seen in the other coupons that were evaluated in these tanks. This is probably because of the lower temperature that the coupons were exposed to. A longer test time would be needed to show difference in the other resin systems. Additional coupon testing was done with BREVER1 resin at 65 C with 10% sodium hypochlorite. The first coupon was cured with cured with BPO/DMA with 1 layer of C-glass veil and the second was cured with BPO/DMA with 1 layer of synthetic polyester veil. The results are shown in Table 4. The coupon that had the polyester veil did very poorly after 12 months with no surface hardness and only 28% of its flexural properties remaining. The coupon that had the C-glass veil did much better in maintaining 47% of its original surface hardness and 70% of its flexural properties. This higher temperature accelerates the decomposition of the sodium hypochlorite and makes it a much more severe test. In the testing at 50 C, the synthetic polyester veil appears to be attacked by sodium hypochlorite and not work as well in this service. The affect of cobalt has been shown in previous work by Don Kelley 3 that was presented at Corrosion 2004. Testing was done in 5.25% sodium hypochlorite for 10 months at 65 C. Three Coupons were made using EVER1 and cured using 0.1% CoNap/MEKP, 0.3% CoNap/MEKP and BPO/DMA. Figure 1 shows the graph of weight loss with time for these three systems. The weight loss was directly related to the amount of cobalt metal in the system. The BPO/DMA cured system which had no cobalt in it only lost 2% of its weight. The cobalt cured systems lost 18% for the 0.3% system and the 0.1% cobalt containing system lost about 7% of its weight. This should translate into longer life of a storage tank cured with BPO/DMA compared to one cured with CoNap/MEKP.

SUMMARY AND CONCLUSION The testing that was done at ambient temperature in a sodium hypochlorite storage tank showed very little difference between a brominated vinyl ester resin and the standard bisphenol A epoxy vinyl ester resins. It was seen that the novolac epoxy vinyl ester resin was showing some signs of resin attack. The laboratory testing conducted at 50 C did distinguished a little more between the resins. It was seen that brominated epoxy vinyl ester resins showed less resin tank attack compared to standard bisphenol A epoxy vinyl ester. This testing also showed that there is no advantage to using synthetic polyester veil over C-glass veil. Some of the testing reported here would argue that C-glass veil is much better that synthetic polyester veil especially at elevated temperatures. The factor that shows the most influence on the performance in sodium hypochlorite is the presence of cobalt in the corrosion liner. The cobalt does cause the resin to be attacked faster. It is recommended that cobalt curing systems not be used in the corrosion liner of sodium hypochlorite storage tanks. Longer tests will have to be run to further distinguish between the brominated and standard epoxy vinyl ester resins at ambient temperatures. From the visual examination, it does appear that the brominated epoxy vinyl ester resins perform better than the standard epoxy vinyl ester resins. Case histories would also indicate that storage tanks and sodium hypochlorite reactors made out of brominated epoxy vinyl ester resins like BREVER1 and BREVER2 in this study will last longer than tanks made out of standard bisphenol A epoxy vinyl ester resins. Lower styrene containing bisphenol A epoxy vinyl ester resins in previous testing has shown that they do not perform as well in this service. That is why they were not included in the study. RECOMMENDATIONS The recommendation for storage tanks and equipment that will be exposed to sodium hypochlorite solutions that have available chlorine higher that 9% would be to use a corrosion liner that is fabricated out of a brominated epoxy vinyl ester resin like BREVER1 and BREVER2 described in this paper. The resin in the corrosion barrier should be cured using BPO/DMA cure system. No cobalt should be present in the corrosion liner of the equipment. Cobalt/MEKP cure systems can be used in the structural portion of the equipment. The corrosion liner should contain a minimum of 1 layer of C-glass veil, 2 layers would be better, backed by 5 mm of chopped strand boron free glass. The corrosion barrier is required to be post cured to obtain the longest service life out of the equipment. The other factor that comes into play on how long a storage tank will last is the quality of the fabrication. A properly designed and fabricated FRP tank that is of high quality can be expected to last over 20 years. A poorly fabricated tank may last only 5-10 years. ACKNOWLEDGEMENTS

The author would like to acknowledge David Dildine of Ashland Inc. who made the corrosion coupons for the testing and Don Daniel for doing the evaluation of the corrosion coupons. REFERENCES 1. Sodium Hypochlorite General Information for the Consumer, Odyssey Manufacturing Co., March 21, 2004 2. ASTM C-581 Standard Practice for Determining Chemical Resistance of Thermoset Resins used in Glass-Fiber Reinforced Structures Intended for Liquid Service, Annual Book of ASTM Standards, July, 2003. 3. Don Kelley, Fiberglass Reinforced Plastic Equipment for Treating Waste Incineration Gases, Corrosion 2004 paper # 04617,(Houston, TX, NACE, 2004) TABLE 1 TEST RESULTS AFTER 12 MONTHS IN 10% SODIUM HYPOCHLORITE AT 50 C Resin Type BREVER1 BREVER1 BREVER1 BREVER2 Cure System CoNap/MEKP BPO/DMA BPO/DMA BPO/DMA Veil Type Polyester Polyester C-Glass C-Glass Flexural Strength 66 104 93 83 Flexural Modulus 79 101 93 87 73 100 98 96 Flat Flat Semi-Gloss Semi-Gloss appearance Resin Attack Moderate Slight None None Resin Type EVER1 EVER2 NEVER Cure System BPO/DMA BPO/DMA BPO/DMA Veil Type C-Glass C-Glass C-Glass Flexural Strength 98 93 88 Flexural Modulus 104 93 93 93 98 76

Slightly flat Slightly flat No gloss appearance Resin Attack Slight Slight Moderate, only 40% of edge coating remains TABLE 2 TEST RESULTS AFTER 12 MONTHS IN 10% SODIUM HYPOCHLORITE STORAGE TANKS IN THRONTON, CO Resin Type BREVER1 BREVER1 BREVER1 BREVER2 Cure System CoNap/MEKP BPO/DMA BPO/DMA BPO/DMA Veil Type Polyester Polyester C-Glass C-Glass Flexural Strength 90 97 113 98 Flexural Modulus 85 100 109 92 119 114 113 112 Resin Attack Slight None None None Resin Type EVER1 EVER2 NEVER Cure System BPO/DMA BPO/DMA BPO/DMA Veil Type C-Glass C-Glass C-Glass Flexural Strength 81 83 103 Flexural Modulus 93 92 100 108 108 106 Resin Attack Very slight Very slight Slight

TABLE 3 TEST RESULTS AFTER 12 MONTHS IN 10% SODIUM HYPOCHLORITE STORAGE TANKS IN CITY OF WESTMINSTER, CO Resin Type BREVER1 BREVER1 BREVER1 BREVER2 Cure System CoNap/MEKP BPO/DMA BPO/DMA BPO/DMA Veil Type Polyester Polyester C-Glass C-Glass Flexural Strength 84 88 131 88 Flexural Modulus 85 94 103 89 111 100 113 105 Resin Attack Slight None None None Resin Type EVER1 EVER2 NEVER Cure System BPO/DMA BPO/DMA BPO/DMA Veil Type C-Glass C-Glass C-Glass Flexural Strength 107 87 105 Flexural Modulus 98 89 99 110 100 106 Resin Attack Very slight Very slight Slight

5 Weight Change, % 0-5 -10 BPO/DMA 0.1% CoNap (6) -15-20 1 4 5 7 10 Time, 0.3% CoNap FIGURE 1 Weight change vs time of bisphenol A epoxy vinyl ester resin coupons exposed to 5.25% sodium hypochlorite at 65 C. TABLE 4 TEST RESULTS AFTER 12 MONTHS IN 10% SODIUM HYPOCHLORITE AT 65 C Resin Type BREVER1 BREVER1 Cure System BPO/DMA BPO/DMA Veil Type Polyester C-glass Flexural Strength Retention, 29 71 % Flexural Modulus Retention, 26 65 % Retention, 0 47 % Attack Moderate Slight