Module Connectors and Cable Specifications



Similar documents
Connector and Cable Specifications

Connectors and Cables

Cable Specifications and Information

Cable Specifications and Information

Inspection and Cleaning Procedures for Fiber Optic Connections

Connecting the Console Port to a PC

Cable Pinouts. SRP I/O Module

PREVENTIVE MAINTENANCE OF FIBER OPTIC CABLES AND OPTICS

RJ45 Shielded (standard) port pinout. CS9000, Jetstream , Lanstream 2000, RTA8/RJX, RRC16, MTA8/RJX & SXDC8/RJX

Cisco CWDM GBIC and CWDM SFP Installation Note

Connecting to the Switch

RC001-4/RC002-4 (REV.B) 4-slot rack mounted chassis User manual

Cabling Guide for Console and AUX Ports

Connector and Cable Specifications

SFP Transceiver Specifications

Cisco Small Form-Factor Pluggable Modules for Gigabit Ethernet Applications

Cisco - Ethernet 100BaseTX and 10BaseT Cables: Guidelines and Specifications

Cable Specifications

Termination Procedure. FCUPC One Piece Connector

RS-232 COMMUNICATIONS

Making a DB to RJ45 adapter.

Cable Specifications. T3 Trunk Cabling APPENDIX

Comtrol Cable User Guide

Why Expanded Beam types are essential in military and other harsh environment applications

Encore Controller to Router Connections

HP ProCurve High-Speed Transceivers Installation Guide

Cable Guide. Click on the subject to view the information. Digi Cables Building Cables General Cable Information

Serial Cables & Adapters

Frame Relay Cabling This section describes the cabling and connector pinouts for the Frame Relay cards.

FIBER OPTIC SYSTEM TEST PROCEDURES

Cisco SFP Optics for Gigabit Ethernet Applications

SINGLEMODE OR MULTIMODE FIBER OPTIC PATCHCORDS

Connecting Serial Interface Cards to a Network

CISCO 10GBASE X2 MODULES

Power, Cable, and Antenna Connection Procedures

Best Practices for Ensuring Fiber Optic System Performance. David Zambrano

Cable Connection Procedures for Cisco 1900 Series Routers

Mini-HDMI Series MINIATURE MULTIMODE FIBER OPTIC HDMI TRANSMISSION SYSTEM

How to Determine the Right Fiber Optic Network Backup Switch For Your Application

RS232C < - > RS485 CONVERTER S MANUAL. Model: LD15U. Phone: / 97 / 98 (M)

Cisco MFE and MGE SFP Transceivers Cisco Small Business Network Accessories

Replacing a Copper or Fiber Transceiver on a NetScaler Appliance

SpectraTec II. Polarized Multi-Laser Source BLUE SKY RESEARCH WAVELENGTHS. The SpectraTec II

RS-422/485 Multiport Serial PCI Card. RS-422/485 Multiport Serial PCI Card Installation Guide

RJ11 RS-232 Interface

Attaching the PA-A1-ATM Interface Cables

When we look at the connector pinout of the RS232 port, we see two pins which are certainly used

N560 series H/W Installation Guide

Perle 10/100/1000 Ethernet Media Converter Module

Cabling Specifications

10/100/1000 Base-T to Gigabit Fiber Media Converter

Owner s Manual

FlexPoint T1/E1 Copper to Fiber Line Driver

BLACK BOX Scalable matrix KVM switch supports up to 1024 ports with fiber or copper cable.

16-Port RS232 to USB2.0 High Speed Multi Serial Adapter (w/ Metal Case) Installation Guide

2-Port RS232/422/485 Combo Serial PCI Card

Route Processor. Route Processor Overview CHAPTER

Cable Guide For all PortServer TS, Digi Connect, and Digi One Products

SC, FC and ST * Hot Melt Fiber Optic Connectors

FOM-5A, 6A. Asynchronous Fiber Optic Modem

Polymer Coated Fiber Cable (PCF)

omega.com ΩOMEGA RS232 Multi-Drop FMA1600-MDB Multi-Drop Box

Installation Guide. x610 Series Layer 3 Stackable Gigabit Ethernet Switches

AT-GS2002/SP. Gigabit Ethernet to Fiber SFP Media Converter. AT-GS2002/SP Media Converter Installation Guide. PN Rev. A

Cable Guide Including all PortServer TS, Digi Connect, and Digi One Products

Full_IG.book Page 1 Monday, January 9, :11 PM. ProSafe 24 Port Gigabit Switch Installation Guide

2012 uptimedevices.com

4RU High Density Shelf Installation Instructions

AS X 48-Port 10G Top-of-Rack Switch. Installation Guide.

Cable Guide For all PortServer TS, Digi Connect, and Digi One Products

Reliable, Consistent, Quality

Optical Power Meter. Specification & User Manual

Gigabit Switching Ethernet Media Converters - Product User Guide

XPort Universal Demo Board User Guide

isco Connecting Routers Back to Back Through the AUX P

Measuring of optical output and attenuation

FullAXS CONNECTOR SEALING & CABLE ASSEMBLY

Configuring the Switch with the CLI-Based Setup Program

Security & Surveillance Cabling Systems

SEL Fiber-Optic Products and Applications

24-Port Channelized E1/T1 Line Card Overview

Copper to Fiber Stand-Alone Media Converter. Quick Installation Guide

M7250P. PoE Powered. Gigabit Ethernet Media Converter 1000BASE-TX TO 1000BASE-SX/LX. Installation Guide

Plug & Play Gigabit Ethernet Media Conversion Module. Application Note

GEU Port Gigabit Switch

A Quick Start Guide to Fiber Inspection, Cleaning, and Test INSPECT BEFORE YOU CONNECT SM

Perle 10/100 Ethernet Media Converters

VG4 Fiber Optic Media Converter

Manual Serial PCI Cards

USER GUIDE. 2 Channel POTS Mux DIN Fiber Link System. Introduction SYSTEM INSTALLATION INFORMATION. The leader in rugged fiber optic technology.

Using a Fabric Extender with a Cisco Nexus 5000 Series Switch

Quick Installation Guide 24-port PoE switch with 2 copper Gigabit ports and 2 Gigabit SFP ports (af Version 15.4W)

BX7000 Multi-Access Gateway Getting Started Guide

Fiber Optic Cable Installation

Fiber Optic Ethernet Media Converter Kit

How To Make A Data Center More Efficient

DEX28-VR3P Quick Installation Guide

Transcription:

Module Connectors, page 1 Cables and Adapters, page 2 Cleaning the Fiber-Optic Connectors, page 6 Module Connectors RJ-45 Connector The RJ-45 connector is used to connect a Category 3, Category 5, Category 5e, or Category 6 foil twisted-pair or unshielded twisted-pair cable from the external network to the module interface connector. Figure 1: RJ-45 Interface Cable Connector Caution Category 5e, Category 6, and Category 6a cables can store large levels of static electricity because of the dielectric properties of the materials used in their construction. Always ground the cables (especially in new cable runs) to a suitable and safe earth ground before connecting them to the module. Caution To comply with GR-1089 intrabuilding and lightning immunity requirements, you must use a foil twisted-pair (FTP) cable that is properly grounded at both ends. OL-30827-02 1

LC Connector LC Connector The LC fiber optic connector is a small form-factor fiber-optic connector that provides high-density fiber connectivity. The LC connector can be used with either MMF cable or SMF cable. The LC connector uses a latching clip mechanism that is similar to the one used on the RJ-45 copper connector. Warning Invisible laser radiation may be emitted from disconnected fibers or connectors. Do not stare into beams or view directly with optical instruments. Statement 1051 Note Make sure that the optical connectors are clean before making the connections. Contaminated connectors can damage the fiber and cause data errors. Figure 2: LC Fiber-Optic Connector Cables and Adapters SFP Module Cables For cabling specifications, refer to the Cisco SFP and SFP+ Transceiver Module Installation Notes. Each port must match the wave-length specifications on the other end of the cable, and the cable must not exceed the stipulated cable length. Copper 1000BASE-T SFP module transceivers use standard four twisted-pair, Category 5 cable at lengths up to 328 feet (100 meters). 2 OL-30827-02

Cable Pinouts Cable Pinouts Figure 3: Four Twisted-Pair Straight-Through Cable Schematic Figure 4: Four Twisted-Pair Semi-Cross Cable Schematic Figure 5: Two Twisted-Pair Straight-Through Cable Schematic Figure 6: Two Twisted-Pair Crossover Cable Schematic OL-30827-02 3

Console Port Adapter Pinouts Identifying a Crossover Cable To identify a crossover cable, compare the two modular ends of the cable. Hold the cable ends side-by-side, with the tab at the back. The wire connected to the pin on the outside of the left plug should be a different color from the wire connected to the pin on the inside of the right plug. Figure 7: Identifying a Crossover Cable Console Port Adapter Pinouts The RS-232 console port uses an 8-pin RJ-45 connector. Use an RJ-45-to-DB-9 adapter cable to connect the switch console port to a console PC. You need to provide a RJ-45-to-DB-25 female DTE adapter to connect the switch console port to a terminal. You can order the kit (part number ACS-DSBUASYN=) from Cisco. Table 1: Console Port ing with a DB-9 Adapter Switch Console Port (DTE) RTS DTR TxD RJ-45-to-DB-9 Terminal Adapter DB-9 Pin 8 6 2 5 5 CTS DSR RxD 4 OL-30827-02

Console Port Mode 2 ing and Pinouts Switch Console Port (DTE) RxD DSR CTS RJ-45-to-DB-9 Terminal Adapter DB-9 Pin 3 4 7 TxD DTR RTS Table 2: Console Port ing with a DB-25 Adapter Switch Console Port (DTE) RTS DTR TxD RxD DSR CTS RJ-45-to-DB-25 Terminal Adapter DB-25 Pin 5 6 3 7 7 2 20 4 CTS DSR RxD TxD DTR RTS Console Port Mode 2 ing and Pinouts This section provides the signaling and pinouts for the console port in mode 2. (The port mode switch in the out position.) Table 3: Port Mode 2 ing and Pinouts (Port Mode Switch Out) Console Port Pin (signal) 1 (RTS) 1 2 (DTR) 3 (RxD) Input/Output Output Output Input OL-30827-02 5

Cleaning the Fiber-Optic Connectors Console Port 4 () 5 () 6 (TxD) 7 (DSR) 8 (CTS) 2 Output Input Input 1 Pin 1 is connected internally to Pin 8. 2 Pin 1 is connected internally to Pin 8. Cleaning the Fiber-Optic Connectors Guidelines Fiber-optic connectors are used to connect two fibers together. When these connectors are used in a communications system, proper connection becomes a critical factor. Fiber-optic cable connectors can be damaged by improper cleaning and connection procedures. Dirty or damaged fiber-optic connectors can result in communication that is not repeatable or is inaccurate. Fiber-optic connectors differ from electrical or microwave connectors. In a fiber-optic system, light is transmitted through an extremely small fiber core. Because fiber cores are often 62.5 microns or less in diameter, and dust particles range from a tenth of a micron to several microns in diameter, dust and any contamination at the end of the fiber core can degrade the performance of the connector interface where the two cores meet. The connector must be precisely aligned, and the connector interface must be absolutely free of trapped foreign material. Connector loss or insertion loss is a critical performance characteristic of a fiber-optic connector. Return loss is also an important factor. Return loss specifies the amount of reflected light; the lower the reflection, the better the connection. The best physical contact connectors have return losses greater than -40 db, although -20 to -30 db is more common. The connection quality depends on two factors: the type of connector and the proper cleaning and connection techniques. Dirty fiber connectors are a common source of light loss. Keep the connectors clean at all times, and keep the dust covers installed when the connectors are not in use. Before installing any type of cable or connector, use a lint-free alcohol pad from a cleaning kit to clean the ferrule, the protective white tube around the fiber, and the end-face surface of the fiber. As a general rule, whenever there is a significant, unexplained loss of light, clean the connectors. The connectors used inside the system are cleaned by the manufacturer and connected to the adapters in a proper manner. The operation of the system should be error free if the customer provides clean connectors on the application side and follows these guidelines: Does not clean the inside of the connector adapters. 6 OL-30827-02

How to Clean the Fiber-Optic Connectors Does not use force or quick movements when connecting the fiber-optic connectors in the adapters. Covers the connectors and adapters to keep the inside of the adapters or the surface of the connectors from getting dirty when not using the connectors or while cleaning the chassis. How to Clean the Fiber-Optic Connectors Caution Use extreme care when removing or installing connectors so that you do not damage the connector housing or scratch the end-face surface of the fiber. Always install protective covers on unused or disconnected components to prevent contamination. Always clean fiber connectors before installing them. Warning Invisible laser radiation may be emitted from disconnected fibers or connectors. Do not stare into beams or view directly with optical instruments. Statement 1051 Procedure Step 1 Step 2 Step 3 Use a lint-free tissue soaked in 99 percent pure isopropyl alcohol to gently wipe the faceplate. Wait five seconds for the surfaces to dry, and repeat. Remove any residual dust from the faceplate with clean, dry, oil-free compressed air. Use a magnifying glass or inspection microscope to inspect the ferrule at an angle. Do not look directly into the aperture. Repeat the process if any contamination is detected. OL-30827-02 7

How to Clean the Fiber-Optic Connectors 8 OL-30827-02