Intel RAID Controller Troubleshooting Guide



Similar documents
Intel Server Board Platform Confidence Test Installation and Operating Instructions

Intel RAID Software v6.x (and newer) Upgrade/Installation Procedures

Recovery BIOS Update Instructions for Intel Desktop Boards

Intel RAID Controller Firmware Update Flow Chart

Intel Server Raid Controller. RAID Configuration Utility (RCU)

Intel RAID Volume Recovery Procedures

Intel Desktop Board D925XECV2 Specification Update

Instructions for Recovery BIOS Update

Intel Desktop Board D101GGC Specification Update

Intel Matrix Storage Manager 8.x

Intel Desktop Board DG43NB

Intel Rapid Storage Technology

BIOS Update Release Notes

PCI-to-SATA RAID Adapter AEC-6890M. User s Manual Version:1.0

Serial ATA PCI Quick Installation Guide

BIOS Update Release Notes

BIOS Update Release Notes

SATA II-150 PCI Quick Installation Guide

The UltraATA 133 PCI is an ultra high-speed dual channel Ultra ATA/133 controller board for use in Pentium-class computer.

Intel Server Board S3420GPRX Intel Server System SR1630GPRX Intel Server System SR1630HGPRX

BIOS Update Release Notes

EUCIP IT Administrator - Module 1 PC Hardware Syllabus Version 3.0

A+ Guide to Managing and Maintaining Your PC, 7e. Chapter 1 Introducing Hardware

E2437. Motherboard. Troubleshooting Guide Q & First Edition September 2006 Copyright 2006 ASUSTeK COMPUTER INC. All Rights Reserved.

Intel N440BX Server System Event Log (SEL) Error Messages

6-Port SATA II 150 PCI Host Card w/raid

Intel ICH5R Serial ATA RAID. Quick User s Guide

Intel Entry Storage System SS4000-E

ATTO ExpressSAS Troubleshooting Guide for Windows

Monitor Characteristics

Intel Server Board S3420GPV

Intel Data Migration Software

SATA II-150 PCI RAID

Intel Server Board S3420GPLX Intel Server Board S3420GPLC Intel Server System SR1630GP Intel Server System SR1630HGP

Intel Matrix Storage Console

Guide to SATA Hard Disks Installation and RAID Configuration

Trusted Platform Module (TPM) Quick Reference Guide

Adaptec SAS RAID Configuration and the Windows OS Installation Instructions

RAID and Storage Options Available on Intel Server Boards and Systems based on Intel 5500/5520 and 3420 PCH Chipset

SATA150 TX2PLUS, TX4 QUICK START GUIDE. Version 1.2

Intel Server S3200SHL

Addonics. 4-Port External SATA II PCI/PCI-X RAID5 Controller Card (ADS3GX4R5-E) User s Guide Revision 1.1 T E C H N O L O G I E S

Monthly Specification Update

C440GX+ System Event Log (SEL) Messages

Intel Server Board S5000PALR Intel Server System SR1500ALR

BIOS Update Release Notes

System Event Log (SEL) Viewer User Guide

RAID and Storage Options Available on Intel Server Boards and Systems

System Utilities. BIOS Setup Utility. Chapter 2. PhoenixBIOS Setup Utility Main Advanced Security Boot Exit. Information

Promise FastTrak 100-Lite RAID Controller

Guide to SATA Hard Disks Installation and RAID Configuration

Guide to SATA Hard Disks Installation and RAID Configuration

Intel Desktop Board DQ45CB

Monthly Specification Update

Intel Desktop Board DP55WB

Intel Compute Stick STCK1A32WFC User Guide. Intel Compute Stick STCK1A32WFC

Intel RAID Controllers

SATA+Ultra ATA RAID CONTROLLER RC212. User Manual

Intel Desktop Board D945GNT

4+1 SATA II 300 IDE/PATA PCI-E. Combo Host Card w/ RAID & Port. Multiplier

User Guide Software Version 2.1.0

PCI SATA + PATA Raid Card

System Release Notes Express5800/320LB System Release Notes

Command Line Interface User Guide for Intel Server Management Software

Intel Server Board S5520HC

Intel Active Management Technology with System Defense Feature Quick Start Guide

IDE2410 ATA-100 IDE RAID Card. Version 1.0

RAID installation guide for Silicon Image SiI3114

BIOS Update Release Notes

ATA-133 IDE RAID Card. Version 1.1

EUCIP - IT Administrator. Module 1 - PC Hardware. Version 2.0

Intel Desktop Board DP35DP. MLP Report. Motherboard Logo Program (MLP) 6/17/2008

Installation Guide. Zip ATAPI Drive. Quick Start Information Installation Notes Technical Notes Troubleshooting Drive Specifications

Getting Started. rp5800, rp5700 and rp3000 Models

Enclosure Management Cabling Guide for Intel C200 and C600 Series Chipset Based Server Systems with Hot-Swap Drive Enclosures

This guide explains how to install an Intel Solid-State Drive (Intel SSD) in a SATA-based desktop or notebook computer.

Guide to SATA Hard Disks Installation and RAID Configuration

ASF: Standards-based Systems Management. Providing remote access and manageability in OS-absent environments

IDE ATA/133 Controller

Express5800/320Lb System Release Notes

Intel Desktop Board DG31GL

Serial ATA 2 Ports PCI Host

SSD Firmware Update Utility Guide

M5281/M5283. Serial ATA and Parallel ATA Host Controller. RAID BIOS/Driver/Utility Manual

Installation Guide MAXTOR SATAII/300 INTERNAL HARD DRIVE

Intel RAID Basic Troubleshooting Guide

Trusted Platform Module (TPM) Quick Reference Guide

Foglight Experience Monitor and Foglight Experience Viewer

Cautions When Using BitLocker Drive Encryption on PRIMERGY

Compaq Presario Desktop Products. Upgrading and Servicing Guide

SATA PCI Express Adapter PEXSATA22I

5520UR 00UR 00UR 625UR 625URSAS 00UR URBRP 600URLX 625URLX

Intel ICH7R/ICH9R/ICH10R HostRAID Setup Guidelines

Intel Desktop Board DG45FC

Chapter 5 Cubix XP4 Blade Server

H ARDWARE C ONSIDERATIONS

Universal Serial Bus Implementers Forum EHCI and xhci High-speed Electrical Test Tool Setup Instruction

HP dx5150 RAID Installation and Setup Guide Version Document Part Number:

PCI/PXI ETHERNET ADAPTERS

SATA II PCIe RAID Quick Installation Guide

Transcription:

Intel RAID Controller Troubleshooting Guide A Guide for Technically Qualified Assemblers of Intel Identified Subassemblies/Products Intel order number C18781-001 September 2, 2002

Revision History Troubleshooting Guide Revision History Date Revision Number September 2002 1.0 Initial release. Modifications ii

Disclaimers Disclaimers Information in this document is provided in connection with Intel products. No license, express or implied, by estoppel or otherwise, to any intellectual property rights is granted by this document. Except as provided in Intel s Terms and Conditions of Sale for such products, Intel assumes no liability whatsoever, and Intel disclaims any express or implied warranty, relating to sale and/or use of Intel products including liability or warranties relating to fitness for a particular purpose, merchantability, or infringement of any patent, copyright or other intellectual property right. Intel products are not intended for use in medical, life saving, or life sustaining applications. Intel may make changes to specifications and product descriptions at any time, without notice. Intel, Pentium, Itanium, and Intel Xeon are trademarks or registered trademarks of Intel Corporation or its subsidiaries in the United States and other countries. *Other names and brands may be claimed as the property of others. Copyright Intel Corporation 2002. iii

Table of Contents Troubleshooting Guide Table of Contents Troubleshooting Overview... 5 Intel RAID Controller Troubleshooting Guide... 7 1. My server will not power on... 7 2. Upon booting, my server starts beeping... 8 3. My system appears to power on, however there is no video... 8 4. Some of my hard drives show up during POST and some do not... 9 5. My RAID controller has an issue not addressed above...10 Additional Questions and Answers...11 1. How do I update the firmware?...11 2. I am unable to complete the firmware update; I get a message that the firmware is intact or the system hangs during when entering StorCon...12 3. I do not see the zero channel RAID card / Modular RAID on Motherboard (MROMB) card during POST...13 4. How do I disable the integrated components?...13 iv

Troubleshooting Overview In the unlikely event you encounter issues, this guide will help you troubleshoot and identify possible problem areas. If you are unable to resolve a problem using this guide, please follow these steps: 1. Visit http://support.intel.com/support/motherboards/server and choose the model of the RAID controller you are using. This site will contain the latest information of known issues and solutions. 2. If you are unable to resolve the issue, send an e-mail to Intel Customer Support using this form: http://support.intel.com/support/motherboards/server/server_form.htm 3. Contact Intel Customer Support using one of the numbers listed here: http://www.intel.com/support/9089.htm This guide will help you collect the data we will need to help you resolve your issues. Each issue includes suggestions that may help you, and a list of information we will need to know you if you need to call us. Please visit the Intel Support website for updated versions of this document at http://support.intel.com/support/motherboards/server Server boards, RAID controllers, and many other computer devices use programmable flash memory parts to store BIOS or firmware code. Please visit the support site for your server board and the RAID controller you are using and download and install the latest BIOS and firmware for the server board and RAID card. Intel server board and RAID card downloads can be found at: http://support.intel.com/support/motherboards/server. Your Intel RAID Controller may include several LEDs that can aid in troubleshooting your system. Please refer to your specific RAID controller s documentation for location and purpose of the LEDs. These LEDs may signal the following events: Indicate that the controller is online (i.e., installed correctly). Indicate that the controller is in Firmware Recovery Mode. Indicate activity on the SCSI Channel. Indicate Bus Master DMA transfers. These LEDs may be referred to later in this document. In addition, the controller may emit a series of beeps. Refer to your specific RAID controller s documentation for definition of the beep code. These beep codes may signal the following events: State of the controller upon boot-up. A change in the state of an array. A change in the controller s environment status (during normal operation). A hardware failure. A series of beep codes may be audible during POST or during RAID array event. Some RAID controllers emit a 1-3 beep code during POST, signifying normal operation. The server board or other add-in peripherals may also emit beep codes. Refer to the documentation for your RAID controller, server board, or add-in components for specific beep code information. 5

6

Intel RAID Controller Troubleshooting Guide 1. My server will not power on Though it is unlikely that a server will not boot, the following are some of the possible reasons for failure to boot: Some ATX power supplies have a power switch on the back of the power supply next to the fan. Is this switched on? Check for proper power cord connections. Some chassis allow the use of two power cords and the system will not power on when a single cord is used and is plugged into the wrong connector. Your RAID controller may require the addition of a memory module. Verify that the module is included on the tested memory list for the RAID controller. The tested memory list is available at http://support.intel.com/support/motherboards/server. Remove and reseat the memory module if memory on the card is installed in a memory socket. Remove all add-in cards, including the RAID controller. See if the server boots using only the on-board components. If successful, add the cards back in one at a time, rebooting between each addition. This will help you determine the card that is causing the problem. The Intel RAID Controller requires additional power to run. Although the amount required is minimal, it may cause the system to exceed the power available from the system power supply. Failure to provide the correct power supply or sufficient output from the power supply may result in a failure of the system to power on. Refer to the server board s Technical Product Specification to calculate the necessary power budget for all installed devices that draw power. These devices may include the memory, disk drives, and add in cards. Verify sufficient power exists to run the system. Examine the LEDs on card and compare them to the product documentation to determine if the LEDs give an indication of the failure. Compare any RAID card beep codes to the codes outlined in the product documentation to determine if the beep codes you hear give any indication of the failure. If you are unable to resolve this issue, contact your customer support representative. Gather the following information before making your phone call: The make and model server board and RAID controller are you using. The version of BIOS and firmware of the server board. The version of the firmware on the RAID controller. The PBA (Product Board Assembly) number on the board. The chassis and power supply the server is using. Note what is displayed on the monitor or any sounds emanating from the server system. 7

2. Upon booting, my server starts beeping Upon power on, beeps can come from the server board, from the RAID controller, or from other devices installed in the system. The message conveyed by the beep codes will vary depending on the make and model of the device. Try to determine which device is emitting the beep codes and refer to the documentation for that device. 3. My system appears to power on, however there is no video Check the following: Look for a blinking cursor in the top left corner of the screen. If the cursor is there, wait 5 minutes to determine if the system will continue the boot process. Your RAID controller may require the addition of a memory module. Verify that the module is included on the tested memory list for the RAID controller. The tested memory list is available at http://support.intel.com/support/motherboards/server. Remove and reseat the memory module if memory on the card is installed in a memory socket. Remove all add-in cards, including the RAID controller. See if the server boots using only the on-board components. If successful, add the cards back in one at a time, rebooting between each addition. This will help you determine the card that is causing the problem. Listen for any beep codes and refer to your product documentation. A 1-3 beep code from the RAID card indicates normal operation. Make sure the monitor is turned on and the video cable is plugged in completely. If you are using a switch box to share a monitor between multiple servers, make sure you have the switch set to the correct server. If you are unable to resolve this issue, contact your customer support representative. Gather the following information before making your phone call: The make and model server board and RAID controller are you using. The version of BIOS and firmware of the server board. The version of the firmware on the RAID controller. The PBA (Product Board Assembly) number on the board. The chassis and power supply the server is using. Note what is displayed on the monitor or any sounds emanating from the server system. 8

4. Some of my hard drives show up during POST and some do not Drives not showing up in post can be caused by a variety of problems. Please check the following: Are you using the latest BIOS and firmware for the server board and the latest firmware for the RAID card? System memory limitations limit the number and size of option ROMs that can be used in the system. If you place too many adapters in the system, or the ROMs on the adapters you have installed take up too much space in memory, the option ROM on your RAID controller may not expand correctly and will not show the hard drives that are connected to it. Try turning off the expansion ROMs for any on-board device that is not being used. For example, if your server board includes a SCSI controller that is not being used, disable this SCSI controller in BIOS setup. For a list of tested peripherals with the Intel RAID controller, download the Tested Operating System and Adapter List from http://support.intel.com/support/motherboards/server. If you are using a Zero Channel Card that utilizes the on board IO controller, such as an on-board SCSI or Serial ATA controller, the Option ROM scan for the on-board device must be enabled. If it is not enabled, drives connected to that device will not show up during POST. Confirm that the drive power cables are firmly connected. If you are using a chassis with a backplane, make sure the power and SCSI cables are properly applied to the backplane and the hard drives are firmly seated in the backplane. Check your SCSI ID numbers. SCSI devices must each have a unique ID on the SCSI bus. This number is set with jumpers on the device. ID numbers should be set starting at 0 and they must be set lower than 8 if booting from the drive. If you are using a server chassis with a backplane, the device IDs are usually automatically set by the backplane, but may be manually configurable. Check for proper termination on the SCSI bus. Intel RAID cards are by default autoterminating. If your hard drives still do not show during post, please call your customer support representative. Note the following information and have it ready to assist the support engineer: Model number and firmware revision of the RAID controller you are using. Manufacturer and model number of other add-in adapters installed in your system. Manufacturer and model number of hard drives installed in the system. Identify the type of termination used for the card. The SCSI IDs of the devices on your SCSI bus. The number and type of SCSI channels. Manufacturer and model of the memory used in the system and on the RAID controller and whether it is on the tested memory list. 9

5. My RAID controller has an issue not addressed above Check the following: Update the firmware files to the latest version. The files required depend of the server board, but may include BIOS, BMC, FRUSDR, HSC. Clear the CMOS upon completing any updates. Update the RAID controller to the latest version of firmware. Update files can be downloaded from http://support.intel.com/support/motherboards/server. Download and apply the latest drivers used for your installation. These drivers may include video, network adapter, SCSI, ATA RAID, chipset, and operating system drivers. Confirm that the processor(s) was installed correctly. If a single processor is installed, it must be in CPU socket 1. When more than one processor is installed, they must be of the same speed and voltage (and within one stepping). Do not attempt to overclock the processors or other components on this system. Overclocking is generally not possible and may damage components and void the warranty of your server board or other components. Confirm that the memory is properly seated and that both the server board and RAID controller memory is listed on the tested memory list. Calculate the power budget to ensure sufficient power is supplied. Power budget information is usually included in the server board product guide or the technical product specification. Information about the RAID controller power-draw is available in the RAID controller hardware guide and is also available at http://support.intel.com/support/motherboards/server. Verify that all chassis, power supply, and processor fans are properly installed and functioning. If installed in a third-party chassis, verify that sufficient cooling is available. When using multiple PCI adapter cards in a PCI riser with more than one slot, populate the slots from the bottom up. On systems without a PCI riser, see if your results vary by moving the RAID controller to a different slot. 10

Additional Questions and Answers These questions are intended to give the reader a general overview of unique features of Intel RAID Controllers. For additional information, consult the product documentation. Other recommended documentation includes: Intel RAID Controller s Technical Product Specification Intel RAID Controller s Product Guide or Hardware Guide Intel RAID Controller s Software Guide All documentation is available on the Intel support website at http://support.intel.com/support/motherboards/server. The product guide or the hardware and software guides are also available on the Resource CD that ships with each Intel RAID Controller as part of the box kit. 1. How do I update the firmware? Firmware can be updated through StorCon. StorCon can be activated a number of ways, including through XROM during POST by pressing <Ctrl> <G> when prompted. Complete instructions for each update method are included in the hardware guide for the RAID controller. Refer to the resource CD that accompanied the product or to the support website listed above. A short list of steps to update the firmware using the XROM method is included here: Follow the procedure below to update the firmware via the XROM version of StorCon: a. Download the firmware image, SRC_RXFW, that contains the latest programs and drivers from the website. b. Format a 3.5 HD disk (1.44MB) and copy the SRC_RXFW file onto the disk. c. With the adapter installed in the system, boot the computer and press <Ctrl> <G> when prompted. This initiates the BIOS version of StorCon. d. Select the applicable RAID controller and press <Enter>. e. If the Express Setup menu is displayed, press <F4> to display the Advanced Setup menu. Select the menu option Configure Controller and press <Enter>. Insert the floppy containing the latest firmware file into the floppy disk drive. f. From the Configure Controller submenu, select Firmware Update and press <Enter>. g. StorCon automatically searches for the firmware file from the floppy drive, A:\. After finding the file, StorCon displays the name, description and version of the firmware. Press <Enter>. h. StorCon reads and checks the firmware file, then displays a warning. Press <Y> to confirm the firmware update. i. StorCon programs the flash eprom. Warning: Do not interrupt the update process. If interrupted the firmware image in the Flash may be damaged. If the firmware is interrupted, follow the firmware recovery process instructions in the next section. 11

j. After StorCon indicates that the update is complete, press any key. k. The focus returns to the Configure Controller submenu. Press <Esc> several times to close the menus and press <Y> to quit StorCon. l. StorCon detects the firmware update and requires a system reboot. Press any key to reboot. When the update process has completed, reboot the computer for the change to take effect. During the boot, the system displays the updated firmware version. You can also relaunch StorCon and select the applicable RAID controller to view its new firmware version at the bottom of the console (for example, FW:2.34.yy-Rzzz). You can also use the operating system version of StorCon to update the firmware. Refer to the Storage Console chapter of the Software Guide for details. 2. I am unable to complete the firmware update; I get a message that the firmware is intact or the system hangs during when entering StorCon As the BIOS on server boards and RAID controllers are updated, it is possible that some combinations of RAID controller BIOS and server board BIOS do not work together so that updating RAID controller firmware through the normal update process is not possible. A firmware recovery process is described here with an override that makes it possible to force the firmware update. To force a firmware update, complete the following steps: a. Move the recovery jumper on the RAID card to Recovery position. b. Download the firmware recovery utility and update code from the website, or make a firmware recovery diskette from the CD and boot to it. c. Choose option 2, recover firmware. d. The system creates a RAM drive and begins copying files to it. Press <Ctrl> <C> when you see the prompt, press CNTL C to interrupt the recovery process". You will be brought to a C: prompt. e. Type "FRU -O" to force overwriting the firmware. (Note: O is the letter O for Overwrite, not the number zero) f. Indicate agreement at the following two prompts. g. Green text will display at the top of the screen indicating that the recovery has started. This will be followed shortly by text that provides the version (flashing) that is being forced. The first few digits of this text are the firmware version number followed by digits that refer to the build number. h. When complete, replace the jumper into the normal position and reboot. 12

3. I do not see the zero channel RAID card / Modular RAID on Motherboard (MROMB) card during POST Zero channel RAID cards are designed to work with the on-board hard drive controller built into the server board you are using. The zero channel RAID card must be inserted into a RAIDIOSenabled slot that is usually on the same bus as the on-board hard drive controller. Ensure that you have inserted the zero channel RAID card into the RAIDIOS enabled slot. Refer to your server board documentation to determine which slot is RAIDIOS enabled. This slot is sometimes labeled Zero Channel, RAIDIOS, or MROMB. 4. How do I disable the integrated components? On-board controllers can usually be disabled through the server board BIOS setup. For information on how to enter the server board BIOS setup utility, refer to the documentation that came with your server board. 13