/ Marley NC Class Cooling Tower /



Similar documents
/ Marley QuadraFlow Cooling Tower /

/ Marley Class 800 Mechanical Draft Cooling Tower /

Sigma Steel CROSSFLOW COOLING TOWER

Cooling and Heat Exchanger Solutions

A Guide to Trouble-Free Cooling Towers

VXT. Open Cooling Towers. Open Cooling Towers. Product Detail VXT - B 1. Engineering Data... B2. Structural Support... B6

800 class NATURAL DRAFT COUNTERFLOW COOLING TOWER

cooling tower inspection tips

Transformer oil cooler ALFA A02

NC 8400 steel. Lenntech. Lenntech bv. Tel Fax

Cooling Systems 2/18/2014. Cooling Water Systems. Jim Lukanich, CWT ChemCal, Inc. Grapevine, TX

A GUIDE TO SELECTING YOUR INDUSTRIAL OVEN

Johnson Air-Rotation Systems

Explosion-Proof Electric Unit Heaters

RPV - RP - RA air handling units

HVAC For Schools How to purchase an HVAC system that meets your school s unique requirements and stays within your budget

Light Duty Commercial Electric Water Heater

Cooking at the Speed of light!

Gas Unit Heaters Duct Furnaces Horizontal - 60 HZ Form No. LF (10/2011) LF24 Standard

Pump Specifications 250 Series Submersible Sump / Effluent Pump 2 Solids handling

MAC-120HE-01 Air-Cooled Chiller

REFRIGERATED COMPRESSED AIR DRYERS

Closed Circuit Cooling Towers

Recirculating Roof Fans Models ESRMD, ESRMDF and ERD

Lenntech. Tel Fax / Ceramic Unilite Cooling Tower /

SECTION HEATING, VENTILATION AND AIR CONDITIONING EQUIPMENT

National Competency Based Skill Training Refrigeration and Air-conditioning Mechanic Logbook

Element D Services Heating, Ventilating, and Air Conditioning

Our professional elevator support staff and emergency elevator repair technicians are available to serve you 24 hours a day, seven days a week.

Mechanical Rooftop Custom Capabilities

Centauri. Condensing Fire Tube Water Boiler 399 to 1000 MBH

By: Jaap Hoogland SPX Cooling Technologies GmbH. CW /Jaap Hoogland/ Seawater Cooling Tower Circuits 1

CEILING CASSETTE FAN COIL UNIT

Permanent Magnet Technology within Direct Drive Cooling Tower Motors Creates System Energy Savings

HEATING AND COOLING SYSTEMS THAT FIT COMFORTABLY WITHIN YOUR BUDGET.

Quadraflow cooling tower

CE6500 Energy Recovery Ventilator

HVAC Preventative Maintenance Basics. Presented by Mike Crawley

Commercial Gas Furnace Upflow

SECTION PACKAGED ROOFTOP AIR CONDITIONING UNITS NON-CUSTOM

COOLING TECHNOLOGY INSTITUTE

INDUSTRIAL DIRECT DRIVEN PISTON COMPRESSORS CL - CH - CK

SECTION MORTUARY REFRIGERATORS

! WARNING. McDonnell & Miller Installation & Maintenance Instructions MM-217(I) Series 150S and 157S (Snap Switch, All Models except 157S-RB-P)

Table V. Troubleshooting Checklist for Refrigeration Systems. Air or non-condensable gas in system. Inlet water warm.

Geareducer Solutions NEW, REBUILD AND REPAIR OPTIONS FOR EXTENDING THE LIFE OF YOUR COOLING TOWER

Federal Wage System Job Grading Standards for Air Conditioning Equipment Operating, Table of Contents

OHV / OHVL Type OH3 Vertical Inline Pumps ISO (API 610)

CoolTop. A unique water cooled air-conditioning unit for server room cooling from the top AC-TOPx-CW-240/60

Medical Air Systems: Scroll

HVAC Systems: Overview

Commercial Boiler Systems and Controls

INSTRUCTIONS FOR HOW TO PROPERLY SELECT A FAN OR BLOWER

ACCENT AIR COMMERCIAL HEAT PUMPS

Commercial Electric Water Heater

Overview. Introduction Cooling Tower Basics Principles of Operation Types of Cooling Towers Common Applications Design Considerations

What Does A Sump Pump Do?

ENGINE COOLING SYSTEM

Oil and Coolant Circulating Heating System. Model - OCSM

1.2 Refrigerant Equipment. General

Adsorption air dryers ADS 1 215

RESIDENTIAL HEATING OIL SERVICE CONTRACT ANNUAL COST $276.00

Commercial Gas Water Heaters

Lesson 36 Selection Of Air Conditioning Systems

ROOFTOP - HEAT PUMP UNIT. This document applies when installing into an air handler or as part of an air handling system.

SERIES ASM NEOPRENE/EPMD FLANGED SINGLE SPHERE CONNECTOR CONNECTORS. Pressures to 225 PSIG (15.51 barg) Temperatures to 230ºF (110ºC)

CoastGuard Two-Stage Air Conditioner with Puron Refrigerant

CTV-1500 Cooling Tower Vacuum Operating & Maintenance Manual

COOLING TOWERS. This section briefly describes the main features of cooling towers.

300 Series PA Pump and Cooler Assemblies

ECOCIAT. Domestic hot water heat recovery unit

SIOUX HYBRID WATER HEATER

University of Houston Master Construction Specifications Insert Project Name

21.1 Functions, Basic Configuration, and Interfaces

Cooling system components, removing and installing

Table of Contents. I. Roof Scuttles

Screw Compressors ESM Fixed Speed & VS Variable Speed

ENGINEERING BULLETIN No. EB 039 Product: Cooling Towers, Closed Circuit Coolers & Evaporative Condensers Date: June 2003

VertiCool Space Saver 2 to 15 tons Water-Cooled and Chilled Water

ARMSTRONG AIR HEAT PUMPS

AIR CONDITIONING EFFICIENCY F8 Energy eco-efficiency opportunities in Queensland Foundries

ADDENDUM NO. 1 TO THE BIDDING DOCUMENTS. HVAC SERVICE AND MAINTENANCE Saint Clair County MidAmerica Saint Louis Airport.

Attachment J-C18.1. HVAC Work Instructions

Test Code: 8297 / Version 1

Commissioning - Construction Documents (Page 1 of 6)

Documenting Results to Validate Energy Savings Projects: Case Study of Direct Drive Cooling Tower Installations: Before and After

Heavy Fuel Oil supply units. The world s best selling HFO supply unit. The right choice for any conditions

Originators of the Flexible Water Tube design

Pump Specifications 405 Series Commercial Drain Pump (High-Temp) 2 Solids handling

MULTIZONE APPLICATION OF SOLUTION UNITS

M7RL Series TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS. High Efficiency / Direct Vent Condensing Downflow Gas Furnace

AIR-COOLED CONDENSERS Technical Guide

Next Generation Data Center Infrastructure

7. COOLING TOWER. 7.1 Introduction

COMMERCIAL HVAC CHILLER EQUIPMENT. Air-Cooled Chillers

An Introduction to Cold Aisle Containment Systems in the Data Centre

Nominal Life Expectancy for Building Components

Product Data Bulletin

Two-Stage Air Conditioner with Puron Refrigerant

Transcription:

/ Marley NC Class Cooling Tower / Q u i e t B y D e s i g n

Four-cell NC Class cooling tower serving a municipal power plant. T h e R e s u l t o f S o u n d E n g i n e e r i n g The NC Class not only sets the benchmark for low sound levels it also sets the benchmark for some of the highest crossflow tonnage densities per box in the industry. For over 50 years NC cooling towers have delivered thermal performance, low maintenance, versatility of options and outstanding value. But, of even greater significance, the NC Class is now quieter. The redevelopment, redesign, the evolution of the NC cooling tower into the NC Class was the first project at SPX Cooling Technologies to fully utilize and employ our new ISO 9001 Certified Product Development Process.

Long Life Construction Available in series 300 stainless steel or rugged heavy mill galvanized steel. Marley ISO certifi ed plants assure quality factory-assembly. Plus, the NC Class stainless steel tower comes with SPX Cooling Technologies exclusive 5-year limited warranty. Low Operating Costs Marley's high-effi ciency fi ll and fans, gravity-fl ow water distribution, and effi cient mechanical drive systems work together to offer maximum cooling with minimum power use. All Season Performance Performs as specifi ed in the heat of summer responds well to energy-management techniques in the spring and fall operates virtually ice-free in the dead of winter and offers simple maintenance all year long. Real World Design Designed for severe wind, seismic, shipping, operating and live loads. CTI Certified Plus, we guarantee the thermal performance of each tower as installed. Factory Mutual Approved FM approval is available on the entire line of NC Class cooling towers. Currently 94 NC Class tower models are FM approved without any additional cost. P r o v e n D e s i g n G u a r a n t e e d P e r f o r m a n c e TOWER MODELS TONS L W H L NC8301 94-180 1956 4267 3099 NC8302 118-242 2413 4725 3099 NC8303 154-297 2413 4725 3632 W NC8304 217-372 2718 5182 3962 NC8305 281-520 3327 5715 3962 1067 ** NC8306 350-582 3632 6045 3962 NC8307 343-651 3632 6833 4064 H NC8309 481-750 4242 6833 4064** NC8310* 567-915 3327 6833 6045** NC8311* 503-1000 3632 6833 6045** NC8312* 626-1274 4242 6833 6045** *Two-story modular cells **Some models in this box size require a taller fan cylinder

NCclass I n a C l a s s b y I t s e l f

N C F e a t u r e H i g h l i g h t s Air Movement Package Removable fan guard welded heavy gauge rods. Hot dip galvanized after fabrication. Eased inlet fan cylinder ensures full area, low turbulent airflow through the cylinder. High efficiency fan wide-chord design for maximum efficiency at low fan tip speeds. Marley System 5 Geareducer drive requires no oil changes for five full years. Offers significant savings in maintenance costs. Marley SofTork coupling absorbs excessive shock loads at start-up. Marley PowerBelt drive (limited current availablity) all aluminum sheaves, easy belt replacement and 40,000-hour bearing life. TEFC Fan Motor 1.15 service factor, variable torque, and specially insulated for cooling tower duty. The NC Class air movement package including the structural support guaranteed against failure for a period of five full years. The motor is warranted separately by the motor manufacturer. Water Distribution System Multiple choices of piping connection options single inlet, dual inlet, top, side or bottom inlet, side outlet or bottom outlet designed to have the right connections for your application. Gravity flow distribution system allows easy, nonrestrictive maintenance. Basin covers are standard. Marley Spiral Target polypropylene nozzles delivers precise distribution of water over the fill area. Marley MX thermoformed PVC film fill suspended from structural steel tubing. Integral louvers keep circulating water confined to fill, even at low air rates. Drift Eliminators limit drift losses to no more than.005% of the design L/s flow rate. Structure Crossflow configuration provides easier and safer maintenance. Series 300 stainless steel or G600 galvanized steel construction. Factory assembled ensures final field installation will be hassle-free. Two large access doors provides nonconfining, quick visual inspection of cold water basin, internal structure, drift eliminators and mechanical equipment in the plenum area.

All NC Class cooling towers are designed for low sound levels using high blade-count, wide-chord fans for maximum efficiency at low tip speeds. For those extreme, low sound applications, consider the NC Class low sound L models. To achieve the very lowest possible sound levels while maintaining efficiency, L models are carefully selected with the best available combination of motor, drive ratio, fan blade-count and blade profile. M e c h a n i c a l l y C o r r e c t Q u i e t b y D e s i g n High Efficiency Axial Fan Adjustable-pitch fan blades permit maximum utilization of rated horsepower allows field adjustments to optimize tower performance. System 5 Geareducer The Geareducer option requires no oil changes for five full years the lowest maintenance requirements in the industry. Reduced waste stream and environmental impact. Independent testing has proven a Marley Geareducer is up to 4 dba quieter than the gearboxes used by most other cooling tower manufacturers. Fan Motor TEFC 1.15 service factor, horizontal-shaft motor designed to Marley specifications for cooling tower duty. Specially insulated for humid cooling tower service. Marley 2400 Geareducer SofTork Coupling Absorbs excessive shock loads at start-up forgives minor misalignment between the motor and Geareducer. Five-Year Mechanical Warranty Five-year total mechanical equipment warranty including mechanical equipment support, plus our exclusive 5-year maintenance-free System 5 Geareducer.

P o p u l a r O p t i o n s Single Inlet Connection choose from either side inlet or bottom inlet connections. All piping from the inlet connection to the distribution basins is part of the tower package*. Handrail and Ladder provides sturdy and stable access to the top of your tower. Ladder safety cages and ladder extensions are also available. Access Door Platform steel structure and bar-grating attached to and supported by the tower. Full length bar grating interior walkways are also available. Mechanical Access Platform provides internal ladder to elevated bar-grating platform with handrail, facilitates maintenance access. Exterior platform with ladder and handrail also available for outside motor option. Modular tower only. Motor Location Outside easily accessible and is not subjected to the constant humidity that exists inside the tower plenum. This option uses a Marley fullfloating stainless steel driveshaft. Distribution Basin Dam allows significant variations in flow rates while protecting the tower from the disadvantages of poor water distribution icing, fill scaling and erratic performance. Permits the operator to stage chillers and pumps, and still circulate water efficiently over all cooling tower cells with the benefit of dramatically reduced fan hp for a given heat load. * Standard pipe material is schedule 40 PVC. Steel piping is available as an option and/or where FM approval is required. Control Systems ranges in sophistication from standard fan starters and disconnects to Programmable Logic Controllers that work in conjunction with your building or process system. Variable Speed Drive provides the ultimate in temperature control, energy management, sound control and mechanical equipment longevity. Solid State Water Level Control Package monitor basin water level with solenoid-valve water makeup. Configurations include makeup along with high and low water level alarm and cutoff and electric basin heater cutoff. Stainless Steel Welded Collection Basin all collection basin parts exposed to the circulating water including structural members projecting into the basin, plus attaching hardware, and all basin options, including sumps are heavy-gauge series 300 stainless steel. Galvanized steel tower option. Stainless Steel Distribution Basins corrosion is usually most aggressive in the hot water distribution basins. Stainless steel provides long, trouble-free service life. Galvanized steel tower option. Extended Geareducer Oil Line includes a dipstick to check Geareducer oil level. Located at the fan deck level near the side of the tower. Air Inlet Screens keep leaves and debris out of the tower with factory-installed, U-edged, galvanized wire mesh screens over the air inlets. One of the larger multicell NC Class models with a variety of options including: motor outside, handrail, ladder, ladder safety cage.

Technical Reference Manual TECH NC provides engineering schematics, data, and information necessary for initial tower layout. See your Marley sales representative for a copy or download at spxcooling.com. Product Specifi cations SPEC SSNC and SPEC NC detail the tower in the form of specifi cation language, and provide technical as well as common-sense information on the importance of your specifi cations. SPEC SSNC applies to the stainless steel NC Class models and SPEC NC applies to the galvanized NC Class models. See your Marley sales representative for a copy of each or download at spxcooling.com. T h e M a r l e y D i f f e r e n c e Just about anyone can put together a device that cools water. Some might even claim to be leaders in the cooling tower business. But the fact is, one company has had more new ideas than all the rest combined. No other cooling tower manufacturer has advanced the industry more than the combined resources of SPX Cooling Technologies. If we can help in any way, feel free to call us. To fi nd your Marley representative, call +44 (0) 1905 720 200 or check the web at spxcooling.com. Cooling Technologies Balcke Hamon Dry Cooling Marley Gregory s Bank Worcester WR3 8AB, UK +44 (0) 1905 720 200 info.uk@ct.spx.com www.spxcooling.com In the interest of technological progress, all products are subject to design and/or material change without notice. 2007 SPX Cooling Technologies uk_nc-07