ACCESSIBILITY STANDARD



Similar documents
accessibility standard

Hotel Accessibility Pack

Hotel accessibility pack

Disabled Access Guide

Access Statement Atlantic Tower Liverpool ( )

1 STAR HOTELS. Caballero Errante Europa Ibis Budget Madrid Vallecas Ibis Madrid Valentín Beato Sancho

AlonA Hotel Access Statement

Hotel Accessibility Pack

Accessibility Design Advice

FACILITIES IN BUILDINGS OTHER THAN DWELLINGS Audience and Spectator Facilities

THE UNIVERSITY OF EDINBURGH. Alexander Graham Bell Building. King s Buildings

ACCESS AUDIT OF WESTPORT HOUSE

New College. School Of Divinity.

ARRIVING AT THE HOTEL

THE UNIVERSITY OF EDINBURGH, Alexander Graham Bell Building, King s Buildings,

THE UNIVERSITY OF EDINBURGH. Pleasance Sports Centre and Gym. The Pleasance.

Common ADA Errors and Omissions in New Construction and Alterations

THE UNIVERSITY OF EDINBURGH. ECA Evolution House.

Customer Access 1 Checklist for Banks, Financial and Legal Services

Accessible Toilets. A unisex facility should have its own entrance. It should not be entered from a single sex facility.

Access Statement for Wood View Guest House

Common ADA Errors and Omissions in New Construction and Alterations

Visual guidelines for student charges

Ministry of the Environment Decree on accessible building

BUILDING REGULATIONS PART M 2004 ACCESS TO AND USE OF BUILDINGS. Designers Checklist of Provisions/Areas for Consideration.

Access to libraries for persons with disabilities - CHECKLIST

Droveway ARCHITECTURAL SERVICES. Disability Access Audit. Sample Gospel Hall. 22 September For

Hotel Accessibility Pack

ADA HOTEL SITE INSPECTION CHECKLIST

CHECKLIST C ACCESSIBLE TOILETS CHECKLIST

Typical storey plan with two toilet clusters SANITARY PROVISION SANITARY PROVISION. Individual washroom. Standalone, unisex individual washroom

IRISH ACCOMMODATION SERVICE AWARDS

Issue ID Description No. of Credits Available. Mandatory Elements Storage of Non-recyclable Waste and Recyclable Household Waste

Introduction. Pre-Arrival. Arrival & Car Parking Facilities. Main Entrance, Reception & Ticketing Area

Universal Design Recommendations for Accessible University Settings. Mauricio A. Lizama, Ph.D., ATP

Area of Rescue Assistance Communication System ADA Code Applicable excerpts:

REQUIREMENT 3. Usable Doors

ACCESS STATEMENT FOR STADIUM TOUR AND MUSEUM, ARSENAL FOOTBALL CLUB

THE UNIVERSITY OF EDINBURGH OLD COLLEGE

The Scottish Parliament Information for visitors

Approved Document M: Part M Access to and use of buildings Volume 1 dwellings. Consultation draft. August 2014

Access to and use of buildings

HOUSING STANDARDS POLICY TRANSITION STATEMENT IMPLEMENTATION: OCTOBER May 2015

Planning Guide for Accessible Bathrooms AS including Amdt , ambulant and complimentary items. Sydney Melbourne Brisbane Auckland

Contents. Booking Transport Getting Around Building Plans Services & Facilities Food & Drink Daytime Visits Access List

Enter & View Report Dr Hendow Bransholme Health Centre Goodhart Road, Hull

Access Statement For Skegness Water Leisure Park

THE UNIVERSITY OF EDINBURGH. Paterson s Land.

The emergency provisions affect the following Building Code sections:

OFFERING THE SELF-BUILDER NEW CHOICE

Expanding Your Market

Accessibility plan. Mövenpick Hotel 's-hertogenbosch

The White House 15 Whirlow Park Road, Sheffield. Park Estates

COUGAR HOME SAFETY ASSESSMENT- VERSION 3.0

ADA Guide for Small Businesses

MINIMUM REQUIREMENTS: FORMAL ACCOMMODATION Hotels and Lodges. Category Entry Requirements

Bath Planning Guidelines With Access Standards

Florida Building Code 2004 SECTION 1009 STAIRWAYS AND HANDRAILS

14-17 May 2015, National Stadium, Warsaw, Poland

Park View Place. Compass. House. Royal Wharf Gardens Endeavour. House. Thameside. Sienna. House. House. Apartments Townhouses.

Section 6. Off-street Bicycle Space Regulations

CLEANING FREQUENCIES FOR THE FOLLOWING AREAS

Section 7: Elevators and Lifts. Main Entry Floor Outside the Elevator

Web version 28/05/08. Building regulations Part M 2004 Disability Discrimination Act 1995

R432. Health, Health Systems Improvement, Licensing. R Nursing Facility Construction. R Legal Authority. R Purpose.

PEOPLE FIRST. How to Plan Events Everyone Can Attend. Braille Accessible Print Assistive Listening Systems

GUARDIAN REFUGE & EMERGENCY VOICE COMMUNICATION SYSTEMS

ACCOMMODATION STUDIO KITCHEN BATHROOM

Choosing a dementia-friendly meeting space

RADAR

Ministry of the Environment Decree. on housing design

BUILDING REGULATIONS GUIDANCE NOTE NHBC BUILDING CONTROL

Page 1 of 6 COMPLIANCE CHECKLIST. > Long Term Care Facility - Nursing Unit

Getting to the V&A South Kensington and accessible parking

GUIDELINES GUEST HOUSE

SOUTH GLOUCESTERSHIRE COUNCIL SPECIFICATION REQUIREMENTS FOR WHEELCHAIR UNITS - DRAFT

Access Statement For St Georges Court Introduction

TECHNICAL GUIDANCE DOCUMENT

Environmental Descriptive Data Collection Standards. SightCompass LLC

THE PENTHOUSES AVENFIELD HOUSE PARK LANE MAYFAIR W1

Building an Accessible and Inclusive School Community

Wheelchair homes design guidelines. Guidelines to achieve the necessary standards for wheelchair users dwellings

ADA. Checklist for Readily Achievable Barrier Removal. The Americans with Disabilities Act. Checklist for Existing Facilities version 2.1.

Workplace Health, Safety & Welfare

NEW YORK. Downloaded

THE UNIVERSITY OF EDINBURGH. Number 5 Forrest Hill

The replacement or modification of existing windows shall comply with the following requirements:

Transcription:

SCANDIC S ACCESSIBILITY STANDARD Here you can read our 135 point accessibility standard. It has been drawn up by carefully following the route taken by guests from the car park on through the whole hotel. We have also talked to disability organisations and guests with physical disabilities and received lots of ideas from our own keen staff. Although we rent our hotels rather than owning them, there is a lot that we can do. 90 of the 135 points are compulsory for all hotels. All 135 of the points need to be applied as we renovate or build new hotels. The standard applies in all nine of the countries in which Scandic is represented. Of course we also have to comply with the legislation in the country concerned. This means that if the legislation in the country in question is stricter on any particular point, that takes precedence. In the cases where our standard is higher than the legislation, of course our standard applies. Our accessibility standard doesn t include everything that we actually do on the ground. Accessibility issues are incorporated as part of our day to day work, whatever the area. This means that for eample, safety issues involving accessibility are in our safety standard, signs in our signage standard, and so on. In other words accessibility issues are an important part of the whole of Scandic and everyone in our team undergoes training in them. We describe the accessibility for each individual hotel on their respective websites. We are the only hotel chain in the world to do this. /Magnus Berglund, Director of Accessibility Scandic Hotels Number Guest need/epectations PARKING & ENTRANCE 1 Disabled parking, at least 2 spaces with a minimum width of 3.6 metres each. 2 Accessible parking must be clearly marked with the wheelchair symbol. 3 Additional signage at parking bays For assistance, please call reception on XXXX. If there is parking (net to the entrance) 4 Clearly signposted and illuminated wheelchair-accessible route between parking and entrance. Wheelchair accessible. 5 Access ramps at changes of level with a maimum gradient of 1:12 at the main entrance to the hotel and to/from the parking area. 6 Contrast markings at start and end of ramps. 7 Main entrance door has a minimum width of 800 mm free clearance. 8 Low or no threshold at the entrance door for easy wheelchair access. 9 Night time door bell accessible from wheelchair, with a sign and illuminated. Height 1200 mm 10 Entrance door provided with automatic push plate, maimum height 1200 mm. If door is not fully automatic. 11 Contrast marking on electric push plate, see list of eplanations. 12 Clearly signed directions if the accessible entrance is not net to the hotel s main entrance/building. 13 The recommended distance to the accessible entrance is a maimum of 25 metres from the car park. 14 Contrast markings are required if there is an electric door opening system. RECEPTION 15 At least 2 cane holders attached to reception desk. 16 Seating and tables close to reception desk. 17 Hearing loop at reception marked with the correct sign. 2014-03-01 Copyright by Scandic

Guest need/epectations 18 Vibrating wake up/fire alarm available to borrow, sign at reception. Clear sign on reception desk. 19 Entrance carpet from entrance to reception in a different colour from flooring, or a guide line. 20 A guide line should be provided if the reception is not immediately inside the entrance. 21 Part of reception at a height adapted for guests in wheelchairs. LOBBY 22 Reachable electric socket for charging electric wheelchairs marked with a sign. Height 1200 mm. 23 Shop clear aisles at least 800 mm wide. Products can be reached from a wheelchair. 24 Clear walkway between reception and lift (for wheelchairs). 25 Wheelchair available to borrow. GUEST COMPUTER 26 Minimum requirement one wheelchair accessible workstation. LIFTS 27 Clear directions to the wheelchair accessible lift. If not all lifts are accessible. 28 Push plate to open doors (if doors are not automatic). 29 Lift button and button panel inside the lift must be able to be reached from a wheelchair. 30 Lift buttons and button panels must be marked in Braille. Tactile buttons in each lift and on each floor. 31 Voice announcements for each floor and whether the lift is going up or down. 32 The hotel must have at least one lift with a minimum door width of 800 mm. 33 Mirror inside the lift opposite lift doors so that it is possible to see when the doors open/close from a wheelchair. MAIN STAIRS (AND STAIRS BETWEEN FLOORS) 34 First and last steps clearly marked with a different colour. Floors + landings. 35 Hand rails on both sides of the staircase (if staircase is wider than 105 cm). 36 Hand rails at the top and bottom of the stairs must etend 300 mm on each side before the stairs start. 37 The hand rails must be in a contrasting colour to the background. 38 Stone or concrete stairs must be provided with a non-slip surface on the edges of the steps. CLOAKROOM 39 Some hangers/hooks must be able to be reached from a wheelchair, height 1200 mm. CORRIDORS (PATHS, WALKWAYS) 40 Corridors to be a minimum of 1300 mm wide. 41 Other indoor areas must have at least 800 mm free clearance. Between wall & pillar MEETING ROOMS 42 Door openings must be at least 800 mm. 43 Meeting rooms without carpet (hard flooring). 50 % of rooms. 44 Phones must be able to be reached from a wheelchair. 45 Coat hangers or hooks for outdoor clothing must be able to be reached from a wheelchair, height 1200 mm. 46 Hearing loops available to borrow for meetings. 47 Permanent hearing loop in all large meeting rooms (<50 people with theatre seating). 48 A sign stating that there is a hearing loop for meetings. 49 Whiteboard fitted at maimum lowest height of 1200 mm at the bottom edge.

Guest need/epectations AUDITORIUM 50 Stage wheelchair accessible. Maimum slope of ramp < 1:12 51 Podium alternative with wheelchair accessibility must be available. 52 Space for wheelchairs in the room, easily accessible. 53 No threshold or low threshold adapted for easy wheelchair access. BREAK OUT AREAS 54 Seating must be available outside meeting rooms. F&B, RESTAURANT AREAS 55 Height of buffets must be 850 900 mm. 56 Glass, china and cutlery must be able to be reached from a wheelchair. 57 Breakfast special bread for people who are gluten and lactose intolerant. GUEST TOILETS ACCESSIBLE TOILETS 58 Signs showing where accessible toilets are located. 59 Door width at least 800 mm free clearance. 900 mm recommended. 60 Rail on the inside of the door, under the handle. 61 Lock with handle, see list of eplanations. 62 No threshold or low threshold adapted for easy wheelchair access. In line with Scandic Safety 63 Alarm. & Security Manual. 64 Mirror above washbasin must be able to be seen from a wheelchair. 65 Full-length mirror on the wall. 66 Contrast marking behind WC, see list of eplanations. 67 Waste paper bin hung on the wall, can be opened from a wheelchair. WASHBASINS 68 Minimum height of washbasin 780 mm. 69 Empty surface immediately adjoining washbasin/wc. 70 Wheelchairs must be able to fit under the washbasin. 71 Single lever mier taps. 72 Accessible soap dispenser, can be reached from a wheelchair. 73 Hand towels can be reached from a wheelchair. 74 Coat hangers/hooks can be reached from a wheelchair, height 1200 mm, and 1600 mm. 75 Cane holder, 1, height 1200 mm. TOILETS 76 Foldable armrests (when buying new, see list of eplanations). 77 Toilet paper holder on arm rest and on wall. DIRECTION SIGNS 78 Clearly marked in contrasting colours. 79 At a height of 1400 1600 mm.

Guest need/epectations SLEEPING ACCESSIBLE ROOMS 80 Phone can be reached from the bed. 81 TV remote control on bedside table. 82 Bed height adjustable for back and legs. 83 Etra electrical socket for electric beds on the wall below the headboard. 84 Recommended total height of bed 550 mm including mattress. 85 At least 800 mm free floor space on one side of the bed. 86 At least 900 mm free floor space on one side of the bed, see list of eplanations. Divided 50/50 right/left. 87 Lights must be able to be switched off from a wheelchair. MISCELLANEOUS ACCESSIBLE ROOMS 88 All accessible rooms must have a connecting door to an adjoining room. 89 Two peepholes in the door, one at ordinary height and one at 1200 mm. 90 Electric push plate for door (if required by the law in the country in question). 91 Contrast marking on electric push plate, see list of eplanations. 92 If there is an electric push plate, it must be marked in a contrasting colour, see list of eplanations. 93 Free clearance at doorway into room of at least 800 mm. 94 Wardrobe must be able to be opened from a wheelchair. 95 Hat/coat shelf, height 1200 mm. 96 Wardrobe shelf can be reached from a wheelchair. 97 All lighting switches must be able to be reached from a wheelchair. 98 Floor lamp must be able to be turned on/off from a wheelchair. 99 Desk accessible in a wheelchair. 100 Desk hung on the wall. 101 Electric socket by desk can be reached from a wheelchair. 102 Wardrobe with sliding doors or without doors. 103 Visual fire alarm. 104 Room thermostat placed so it can be reached from a wheelchair, height 1200 mm. BATHROOM ACCESSIBLE ROOMS 105 Free clearance at doorway into room of at least 800 mm. 106 Rail on the inside of the door, under the handle or sliding door. 107 No threshold or low threshold adapted for easy wheelchair access. En line with Scandic Safety 108 Alarm. & Security Manual 109 Minimum height of washbasin 780 mm. 110 Wheelchairs must be able to fit under the washbasin. 111 Single lever mier tap reachable from a wheelchair. 112 One accessible soap dispenser, can be reached from a wheelchair. 113 Towels can be reached from a wheelchair.

Guest need/epectations 114 Coat hangers/hooks can be reached from a wheelchair, height 1200 mm, and 1600 mm 115 Mirror above washbasin must be able to be seen from a wheelchair. 116 If there is a make-up mirror, it must be able to be reached from a wheelchair. 117 Hair dryer reachable from a wheelchair. SHOWER 118 Accessible with a wheelchair. 119 Thermostat tap. 120 One shower gel/shampoo holder, can be reached from a wheelchair. 121 Empty space (maimum height 1200 mm) for shampoo, etc. 122 Shower stool available. 123 Shower stool with back and arm rests compulsory with new purchasing. 124 Towels can be reached from a wheelchair. 125 Hooks must be provided at two heights. 126 Shower head must be at its lowest level when guests arrive. 127 Shower head must be fitted at a maimum lowest height of 1200 mm. 128 Shower curtain or glass shower wall. Depending on measurements. Fitted in newly built hotels, 129 Glass shower wall. renovations or replaced where measurements allow. 130 Railings/handles must be provided in the shower. TOILET AREA 131 Foldable arm rests. 132 Foldable and height adjustable and removable armrests on both sides, see list of eplanations. 133 Toilet paper holder on arm rest and on the wall. 134 Contrast marking behind WC. 135 Waste paper bin hung on the wall, can be opened from a wheelchair.